in-vivo dataset

3 papers · 8 extracted observations · quantitative mri mapping · Markdown · CSV · JSON API

Also indexed as: in-vivo-dataset

Showing 8 of 8 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026MRI2Qmap proposedT1+T2 MAPE7.50%Quantitative Mri Mapping · 0-shot · regions=white and gray matter · acceleration-factor=R=2MRI2Qmap: multi-parametric quantitative mapping with MRI-driven denoising priors
Source quote
L580: MRI2Qmap │ 7.50 │ 3.25 │ 4.25 │ 41.58 │ 35.44 │ 35.13
2026MRI2Qmap proposedT1+T2 MAPE9.88%Quantitative Mri Mapping · 0-shot · regions=white and gray matter · acceleration-factor=R=4MRI2Qmap: multi-parametric quantitative mapping with MRI-driven denoising priors
Source quote
L583: MRI2Qmap │ 9.88 │ 4.18 │ 5.70 │ 38.39 │ 32.27 │ 32.87
2026MRI2Qmap proposedT1+T2 MAPE11.35%Quantitative Mri Mapping · 0-shot · regions=white and gray matter · acceleration-factor=R=6MRI2Qmap: multi-parametric quantitative mapping with MRI-driven denoising priors
Source quote
L586: MRI2Qmap │ 11.35 │ 4.74 │ 6.61 │ 36.67 │ 30.70 │ 31.51
2026MRFPnP (MRF-PnP) baselineT1+T2 MAPE7.56%Quantitative Mri Mapping · method-domain=supervised MRF · acceleration-factor=R=2MRI2Qmap: multi-parametric quantitative mapping with MRI-driven denoising priors
Source quote
L579: MRFPnP │ 7.56 │ 3.15 │ 4.41 │ 41.66 │ 35.74 │ 36.23
2026MRFPnP (MRF-PnP) baselineT1+T2 MAPE10.07%Quantitative Mri Mapping · method-domain=supervised MRF · acceleration-factor=R=4MRI2Qmap: multi-parametric quantitative mapping with MRI-driven denoising priors
Source quote
L582: MRFPnP │ 10.07 │ 4.20 │ 5.87 │ 38.62 │ 32.85 │ 34.02
2026MRFPnP (MRF-PnP) baselineT1+T2 MAPE11.83%Quantitative Mri Mapping · method-domain=supervised MRF · acceleration-factor=R=6MRI2Qmap: multi-parametric quantitative mapping with MRI-driven denoising priors
Source quote
L585: MRFPnP │ 11.83 │ 5.10 │ 6.73 │ 36.58 │ 30.82 │ 32.52
2021BSupK_s (strongly supervised baseline) baseline non-standard sliceIoU0.482Pose Regression · split: test · training=strongly-supervised · tolerance=t=0 · instrument=left · cross-validation=four leave-one-day-out foldsA Kinematic Bottleneck Approach for Pose Regression of Flexible Surgical Instruments Directly From Images
Source quote
L144: BSupK_s │ 0.280 │ 0.482 │ 0.327 │ 0.461
2020Andersén et al. deep learning baselineRoot-mean-square distance (RMSD)0.55 mmInstrument Detection · data-split=S: 713/389 treatments · resolution=128×128×128 · application=brachytherapy/biopsyMedical Instrument Detection in Ultrasound-Guided Interventions: A Review
Source quote
L336: Anders{\'e}n et al. \cite{andersen2020deep} │ 2020 │ 128×128×128 │ S: 713/389 treatments │ RMSD/t │ 0.55 mm/<2 sec.