IEEE 39-bus system
21 papers · 52 extracted observations · transient stability assessment · Markdown · CSV · JSON API
Also indexed as: ieee-39-bus-system
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | PGNN (Parallel Graph Neural Network) SOTA frontier (+1 variant) | 100% | 2025-06-01 | Effectiveness experiment with 5 (50%) synchronous generators replaced by photovoltaic… | Efficient Extreme Operating Condition Search for Online Relay Setting Calculation in Renewable Power Systems Based on Parallel Graph Neural NetworkSource quote39 │ 94.1% │ 96.5% │ 99.5% │ 99.6% │ 100% |
| 2 | TrAdaBoost (augmented dataset) SOTA frontier (+1 variant) | 95.44% | 2021-02-01 | dataset=augmented · evaluation=N-1 pre-fault · contingency=line 21-22 · N-1 pre-fault TSA; compromise strategy minimizes FP while staying within 0.2 percenta… | Versatile and Robust Transient Stability Assessment via Instance Transfer LearningSource quoteTrAdaBoost │ Augmented │ 1.55% │ 92.74% │ 96.13% │ 97.35% │ 95.44% |
Regime0-shot (4)
Showing 35 of 35 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | LASS-ODE-Power (listed as LASS-ODE in the table) proposed | Over-frequency MSE (× 10^-2) | 0.12 | 0-shot · bus=31 · disturbance=0.1 p.u. load decrease | Predicting Power-System Dynamic Trajectories with Foundation ModelsSource quoteL423: Bus 31 │ Zero-shot │ 0.12 │ 166.40 │ 53.00 │ 26.29 │ 3.37 │ 29.88 │ 43.64 │ 5.00 |
| 2026 | LASS-ODE-Power (listed as LASS-ODE in the table) proposed | Under-frequency MSE (× 10^-2) | 3.37 | 0-shot · bus=31 · disturbance=0.1 p.u. load increase | Predicting Power-System Dynamic Trajectories with Foundation ModelsSource quoteL423: Bus 31 │ Zero-shot │ 0.12 │ 166.40 │ 53.00 │ 26.29 │ 3.37 │ 29.88 │ 43.64 │ 5.00 |
| 2025 | Proposed Method (W/ LDM) proposed | Error | 2.47% | variant=with LDM · sampling_points=6000 | Deep Generative Model-Aided Power System Dynamic State Estimation and Reconstruction with Unknown Control Inputs or Data DistributionsSource quoteL357: Proposed Method │ \multirow{2}{*}{23.93} │ \multirow{2}{*}{2.47%} │ \multirow{2}{*}{2.67%} │ \multirow{2}{*}{31.78} │ \multirow{2}{*}{2.19%} │ \multirow{2}{*}{1.33%} |
| 2025 | Proposed Method (W/ LDM) proposed | Time | 23.93 s | variant=with LDM · sampling_points=6000 | Deep Generative Model-Aided Power System Dynamic State Estimation and Reconstruction with Unknown Control Inputs or Data DistributionsSource quoteL357: Proposed Method │ \multirow{2}{*}{23.93} │ \multirow{2}{*}{2.47%} │ \multirow{2}{*}{2.67%} │ \multirow{2}{*}{31.78} │ \multirow{2}{*}{2.19%} │ \multirow{2}{*}{1.33%} |
| 2025 | Proposed Method (W/ LDM) proposed | Ratio | 2.67% | variant=with LDM · sampling_points=6000 | Deep Generative Model-Aided Power System Dynamic State Estimation and Reconstruction with Unknown Control Inputs or Data DistributionsSource quoteL357: Proposed Method │ \multirow{2}{*}{23.93} │ \multirow{2}{*}{2.47%} │ \multirow{2}{*}{2.67%} │ \multirow{2}{*}{31.78} │ \multirow{2}{*}{2.19%} │ \multirow{2}{*}{1.33%} |
| 2025 | PGNN (Parallel Graph Neural Network) proposed | OC-Acc | 94.1% | split: test | Efficient Extreme Operating Condition Search for Online Relay Setting Calculation in Renewable Power Systems Based on Parallel Graph Neural NetworkSource quoteL340: 39 │ 94.1% │ 96.5% │ 99.5% │ 99.6% │ 100% |
| 2025 | PGNN (Parallel Graph Neural Network) proposed | PS-Acc | 100% | split: test | Efficient Extreme Operating Condition Search for Online Relay Setting Calculation in Renewable Power Systems Based on Parallel Graph Neural NetworkSource quoteL340: 39 │ 94.1% │ 96.5% │ 99.5% │ 99.6% │ 100% |
| 2025 | proposed analytical sensitivity formula (Eq. sensitivity) proposed | sensitivity D_beta | 12.5493 | split: test · beta=0.95 for generators; generated with InverseBeta (beta_0,k=0.95) for lines · perturbation=u_ij=√2/2 for lines (2,3) and (23,24); zero for remaining lines | Inverse Chance Constrained Optimal Power FlowSource quoteL224: The analytical sensitivity computed by \eqref{sensitivity} is 12.5493, |
| 2024 | Cyber defense game proposed | Defender cyber-defense effort at Nash equilibrium (u_d^NE) | 0.58 | game-parameters=γ(u_d)=√u_d+0.1; ζ(u_a)=2.5 log(u_a+1)+0.1; C_d=C_a=0.2u² | Integrated Cyber-Physical Resiliency for Power Grids under IoT-Enabled Dynamic Botnet AttacksSource quoteL716: To find the NE of the cyber defense game, the defender and attacker respond to each other's action optimally and repeatedly, as shown in Fig.~\ref{fig:cyber_game_nash}. The defender and attacker's optimal response functions are depicted in Fig.~\ref{fig:cyber_game_nash.1}. The intersection of two functions shows that the game admits a NE (u_d (NE), u_a (NE)) = (0.58, 0.76), which specifies the defense and attack strategies at the cyber layer. |
| 2024 | Cyber defense game proposed | Attacker cyberattack effort at Nash equilibrium (u_a^NE) | 0.76 | game-parameters=γ(u_d)=√u_d+0.1; ζ(u_a)=2.5 log(u_a+1)+0.1; C_d=C_a=0.2u² | Integrated Cyber-Physical Resiliency for Power Grids under IoT-Enabled Dynamic Botnet AttacksSource quoteL716: To find the NE of the cyber defense game, the defender and attacker respond to each other's action optimally and repeatedly, as shown in Fig.~\ref{fig:cyber_game_nash}. The defender and attacker's optimal response functions are depicted in Fig.~\ref{fig:cyber_game_nash.1}. The intersection of two functions shows that the game admits a NE (u_d (NE), u_a (NE)) = (0.58, 0.76), which specifies the defense and attack strategies at the cyber layer. |
| 2023 | Proposed multi-step constraint screening with ground-truth generator states proposed non-standard slice | screening rate | 95.3% | scenario=sample-aware · generator-states=ground-truth | Fast Constraint Screening for Multi-Interval Unit CommitmentSource quoteL19: To address such challenges, we develop one of the first multi-interval UC constraint screening models to narrow down the search space of line flow constraints reliably, leading to screening strategy with more efficient performance. Our key insights lie on integrating the temporal constraints, i.e., the ramping constraints to the standard screening model, and such approach can be applied for either given load region or individual load sample. The potential of utilizing the ML predictions of generator states to improve the screening efficiency is also explored. Specifically, we formulate a tractable linear programming problem for multi-interval UC, and prove that more inactive constraints can be eliminated without changing the feasible region of original UC problem. Moreover, our method can be flexibly integrated to screen constraints for either one specific load vector, or to achieve solver warm-start (offline constraint screening beforehand to get the reduced problem which can be later used for real-time operation problem) for a given load region. We term these two cases as sample-aware~\cite{zhai2010fast} and sample-agnostic~\cite{roald2019implied} constraint screening respectively. Specially, for the sample-aware case, we further propose to make use of ML prediction on commitment schedule to better limit the search space of the constraint screening problem. In the sample-aware case on IEEE 39-bus system, our proposed method with ground truth generator states can achieve 95.3% screening rate, achieving a boost compared to the standard constraint screening~\cite{zhai2010fast} (82%). With partial predictions, the feasible rate of our method reach 84% while the solution gap is only 0.32%. In the sample-agnostic case on 118-bus, our procedure can also find the most compact form of UC problem after the more efficient screening process. |
| 2023 | Proposed multi-step constraint screening with partial KNN predictions proposed | feasible rate | 84% | split: val · K=5 · scenario=sample-aware · prediction-interval=4 · generator-state-predictions=partial KNN · validation-samples-per-case=50 | Fast Constraint Screening for Multi-Interval Unit CommitmentSource quoteL19: To address such challenges, we develop one of the first multi-interval UC constraint screening models to narrow down the search space of line flow constraints reliably, leading to screening strategy with more efficient performance. Our key insights lie on integrating the temporal constraints, i.e., the ramping constraints to the standard screening model, and such approach can be applied for either given load region or individual load sample. The potential of utilizing the ML predictions of generator states to improve the screening efficiency is also explored. Specifically, we formulate a tractable linear programming problem for multi-interval UC, and prove that more inactive constraints can be eliminated without changing the feasible region of original UC problem. Moreover, our method can be flexibly integrated to screen constraints for either one specific load vector, or to achieve solver warm-start (offline constraint screening beforehand to get the reduced problem which can be later used for real-time operation problem) for a given load region. We term these two cases as sample-aware~\cite{zhai2010fast} and sample-agnostic~\cite{roald2019implied} constraint screening respectively. Specially, for the sample-aware case, we further propose to make use of ML prediction on commitment schedule to better limit the search space of the constraint screening problem. In the sample-aware case on IEEE 39-bus system, our proposed method with ground truth generator states can achieve 95.3% screening rate, achieving a boost compared to the standard constraint screening~\cite{zhai2010fast} (82%). With partial predictions, the feasible rate of our method reach 84% while the solution gap is only 0.32%. In the sample-agnostic case on 118-bus, our procedure can also find the most compact form of UC problem after the more efficient screening process. |
| 2023 | Proposed multi-step constraint screening with partial predictions proposed | objective-value gap between reduced and original UC problems | 0.32% | scenario=sample-aware · comparison=reduced vs original UC objective · generator-state-predictions=partial | Fast Constraint Screening for Multi-Interval Unit CommitmentSource quoteL347: Sample-aware screening tasks: We consider three scenarios: i) without generator statuses predictions, ii) with partial predictions, and iii) with ground truth are considered to verify the effectiveness of the proposed method. When there is no generator statuses predictions, our multi-step method reduces 81.16% of line limits as shown in Table.\ref{table2}. With partial predictions, the number of remaining constraints of multi-step is only 69% of single-step method, and the CPU time solving the original problem is 1.103 times faster than single-step method according to Table \ref{table4}. It can be seen that multi-step method can always eliminate more inactive constraints, and thus taking less time to solve the reduced UC problem. Besides, the infeasible rate of the original problem is only 16%, and the gap of objective value between the reduced and the original UC problem is only 0.32%. Note that the bias between the solution of binary variables obtained by the screening model and the UC problem does not cause the infeasible case due to the line limits misidentification, which verifies Corollary 3. According to Fig. \ref{fig4}, the case with the ground truth can eliminate the most inactive constraints, while with the partial predictions the remaining constraints can still be sufficiently reduced compared to the case without prediction. |
| 2022 | Proposed terminal-voltage calculation method proposed | Maximum error percentage across all nodes | 0.21% | fault=nearby three-phase short circuit at node 30 · wind-farm=PMSG-WTG · fault-duration=3.0–3.1 s | A Dynamic Equivalent Method for PMSG-WTG Based Wind Farms Considering wind Speeds and Fault SeveritiesSource quoteL428: When \alpha ^{f (-')}-pcc=0.2250, the terminal voltages of PMSG-WTGs at the moment before fault clearance can be calculated using the method proposed in Section V.A. The calculation results are compared with the simulation results of detailed model, as shown in figure. \ref{fig_17}. The maximum error percentage of all nodes is 0.21%, which proves the validity of the method proposed in Section V.A. |
| 2022 | RT-IFGSM (SAC-based UVLS model) proposed | AER | -27157.80 | split: test · model=SAC-based UVLS · access=white-box · attack=RT-IFGSM | Exploring the Vulnerability of Deep Reinforcement Learning-based Emergency Control for Low Carbon Power SystemsSource quoteL334: -27157.80 |
| 2022 | RT-IFGSM (SAC-based UVLS model) proposed | BRR | 0.394 | split: test · model=SAC-based UVLS · access=white-box · attack=RT-IFGSM | Exploring the Vulnerability of Deep Reinforcement Learning-based Emergency Control for Low Carbon Power SystemsSource quoteL335: 0.394 |
| 2022 | RT-IFGSM with DB-RDP defense (SAC-based UVLS model) proposed | AER | -8709.32 | split: test · model=SAC-based UVLS · access=white-box · attack=RT-IFGSM · defense=DB-RDP | Exploring the Vulnerability of Deep Reinforcement Learning-based Emergency Control for Low Carbon Power SystemsSource quoteL338: -8709.32 |
| 2022 | RT-IFGSM with DB-RDP defense (SAC-based UVLS model) proposed | BRR | 0.159 | split: test · model=SAC-based UVLS · access=white-box · attack=RT-IFGSM · defense=DB-RDP | Exploring the Vulnerability of Deep Reinforcement Learning-based Emergency Control for Low Carbon Power SystemsSource quoteL339: 0.159 |
| 2021 | TrAdaBoost (augmented dataset) proposed | FP (unsafe misclassification) | 1.55% | dataset=augmented · evaluation=N-1 pre-fault · contingency=line 21-22 | Versatile and Robust Transient Stability Assessment via Instance Transfer LearningSource quoteL110: TrAdaBoost │ Augmented │ 1.55% │ 92.74% │ 96.13% │ 97.35% │ 95.44% |
| 2021 | TrAdaBoost (Training dataset) proposed | FP (unsafe misclassification) | 2.30% | dataset=training · evaluation=N-1 pre-fault · contingency=line 21-22 | Versatile and Robust Transient Stability Assessment via Instance Transfer LearningSource quoteL112: TrAdaBoost │ Training │ 2.30% │ 94.13% │ 94.25% │ 96.16% │ 95.35% |
| 2021 | TrAdaBoost (augmented dataset) proposed | Acc. | 95.44% | dataset=augmented · evaluation=N-1 pre-fault · contingency=line 21-22 | Versatile and Robust Transient Stability Assessment via Instance Transfer LearningSource quoteL110: TrAdaBoost │ Augmented │ 1.55% │ 92.74% │ 96.13% │ 97.35% │ 95.44% |
| 2021 | TrAdaBoost (Training dataset) proposed | Acc. | 95.35% | dataset=training · evaluation=N-1 pre-fault · contingency=line 21-22 | Versatile and Robust Transient Stability Assessment via Instance Transfer LearningSource quoteL112: TrAdaBoost │ Training │ 2.30% │ 94.13% │ 94.25% │ 96.16% │ 95.35% |
| 2021 | TrAdaBoost (augmented dataset) proposed | Pre. (precision) | 96.13% | dataset=augmented · evaluation=N-1 pre-fault · contingency=line 21-22 | Versatile and Robust Transient Stability Assessment via Instance Transfer LearningSource quoteL110: TrAdaBoost │ Augmented │ 1.55% │ 92.74% │ 96.13% │ 97.35% │ 95.44% |
| 2021 | TrAdaBoost (augmented dataset) proposed | Spe. (specificity) | 97.35% | dataset=augmented · evaluation=N-1 pre-fault · contingency=line 21-22 | Versatile and Robust Transient Stability Assessment via Instance Transfer LearningSource quoteL110: TrAdaBoost │ Augmented │ 1.55% │ 92.74% │ 96.13% │ 97.35% │ 95.44% |
| 2021 | SI-DNN proposed | Average Test MSE | 3.3 | split: test · mse-scale=×10^-3 · training-size=10 | Learning to Solve the AC-OPF using Sensitivity-Informed Deep Neural NetworksSource quoteL350: 10 │ 8.6 │ 738 │ 3.3 │ 746 |
| 2021 | BCU + expansion (N=6) proposed | CCT | 0.540 | model=lossless · fault-bus=3 · fault-type=three-phase short-circuit · expansion-iterations=6 | Approaching the Transient Stability Boundary of a Power System: Theory and ApplicationsSource quoteL457: 3 │ 23.42 │ 0.669 │ 16.15 │ 0.519 │ -22.40 │ 2.156 │ 0.528 │ -21.15 │ 0.047 │ 0.532 │ -20.53 │ 0.114 │ 0.540 │ -19.28 │ 0.269 |
| 2021 | SINDy proposed | Execution time | 86 ms | hardware=MacBook Pro, 2.3 GHz Dual-Core Intel Core i5, 8GB RAM | A Comparison of Data-Driven Techniques for Power Grid Parameter Estimation.Source quoteL186: SINDy (IEEE 39-bus) │ 86~ms |
| 2020 | Model-free end-to-end learning framework proposed | loss in dispatch cost | 8.24% | Compared with the conventional approach benchmark on the IEEE 39-bus system. | Effective End-to-End Learning Framework for Economic DispatchSource quoteL488: Figure \ref{IEEE39} illustrates the performance improvement of the model-free framework, compared with the conventional approach as a benchmark. While our framework generates 72.85% more load prediction error, it does reduce the loss in dispatch cost by 8.24%. |
| 2020 | Proposed minimum-weight feedback-edge-set D-FACTS placement proposed | D-FACTS deployment-set size (|L_D|) | 8 links | Deployment set intended to enable detection of CCPAs against any transmission line. | Moving-Target Defense Against Cyber-Physical Attacks in Power Grids via Game TheorySource quoteL449: IEEE 39-bus system │ 36 │ 8 |
| 2020 | Proposed negotiation algorithm with incentive function proposed | Expected rewards during negotiation | 503,800 $ | agent=7 · iteration=1 · RUL-scenario-paths=50 · simulation-horizon=365 days | Multi-agent maintenance scheduling based on the coordination between central operator and decentralized producers in an electricity marketSource quoteL515: 7 │ 503,800 │ 704,100 │ 704,100 |
| 2020 | Proposed negotiation algorithm with incentive function proposed | Expected rewards during negotiation | 662,900 $ | agent=10 · iteration=1 · RUL-scenario-paths=50 · simulation-horizon=365 days | Multi-agent maintenance scheduling based on the coordination between central operator and decentralized producers in an electricity marketSource quoteL517: 10 │ 662,900 │ 1,054,000 │ 1,455,800 |
| 2020 | Proposed negotiation algorithm with incentive function proposed | Expected rewards during negotiation | 1,054,000 $ | agent=10 · iteration=2 · RUL-scenario-paths=50 · simulation-horizon=365 days | Multi-agent maintenance scheduling based on the coordination between central operator and decentralized producers in an electricity marketSource quoteL517: 10 │ 662,900 │ 1,054,000 │ 1,455,800 |
| 2020 | Proposed negotiation algorithm with incentive function proposed | Expected rewards during negotiation | 1,455,800 $ | agent=10 · iteration=3 · RUL-scenario-paths=50 · simulation-horizon=365 days | Multi-agent maintenance scheduling based on the coordination between central operator and decentralized producers in an electricity marketSource quoteL517: 10 │ 662,900 │ 1,054,000 │ 1,455,800 |
| 2019 | Proposed graph-theoretic D-FACTS deployment set proposed | Size of D-FACTS deployment set (|\mathcal{L}_D|) | 8 links | Minimum-sized deployment set for detecting CCPAs against any transmission line. | Moving-Target Defense for Detecting Coordinated Cyber-Physical Attacks in Power GridsSource quoteL275: IEEE 39-bus system │ 36 │ 8 |
| 2013 | Sparsity-promoting WAC controller K*_1 (γ=1) proposed | Tolerable time-delay margin for the remote feedback signal | 3.964 s | gamma=1 | Sparsity-Promoting Optimal Wide-Area Control of Power NetworksSource quoteL368: For the wide-area controller~\subscr{u}{wac}(t) = -K-1 (*)x(t), if the local control \subscr{u}{wac}^{\textup{(loc)}}(t) is absorbed in the plant, then we obtain a 58.303 (\circ) phase margin with respect to the remote control input \subscr{u}{wac}^{\textup{(rem)}}(t). The corresponding tolerable time-delay margin is 3.964\,\textup{s}. {From a simulation of the linearized power grid model \eqref{eq: power network model}, we observe that a delay of 750\textup{ms} of the remote feedback signal \subscr{u}{wac}^{\textup{(rem)}}(t) does not significantly affect the closed-loop performance; see Fig.~\ref{Fig: time-series NE 2}(c) and Fig.~\ref{Fig: time-series NE 2}(f). In the delayed case, only a slight distortion of the trajectories of generator 1 (which is implementing the remote WAC signal \subscr{u}{wac}^{\textup{(rem)}}(t)) is noticed.} |