IEEE 39-bus system
21 papers · 52 extracted observations · transient stability assessment · Markdown · CSV · JSON API
Also indexed as: ieee-39-bus-system
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | PGNN (Parallel Graph Neural Network) SOTA frontier (+1 variant) | 100% | 2025-06-01 | Effectiveness experiment with 5 (50%) synchronous generators replaced by photovoltaic… | Efficient Extreme Operating Condition Search for Online Relay Setting Calculation in Renewable Power Systems Based on Parallel Graph Neural NetworkSource quote39 │ 94.1% │ 96.5% │ 99.5% │ 99.6% │ 100% |
| 2 | TrAdaBoost (augmented dataset) SOTA frontier (+1 variant) | 95.44% | 2021-02-01 | dataset=augmented · evaluation=N-1 pre-fault · contingency=line 21-22 · N-1 pre-fault TSA; compromise strategy minimizes FP while staying within 0.2 percenta… | Versatile and Robust Transient Stability Assessment via Instance Transfer LearningSource quoteTrAdaBoost │ Augmented │ 1.55% │ 92.74% │ 96.13% │ 97.35% │ 95.44% |
Regime0-shot (4)
Showing 8 of 8 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | PGNN (Parallel Graph Neural Network) proposed | OC-Acc | 94.1% | split: test | Efficient Extreme Operating Condition Search for Online Relay Setting Calculation in Renewable Power Systems Based on Parallel Graph Neural NetworkSource quoteL340: 39 │ 94.1% │ 96.5% │ 99.5% │ 99.6% │ 100% |
| 2025 | PGNN (Parallel Graph Neural Network) proposed | PS-Acc | 100% | split: test | Efficient Extreme Operating Condition Search for Online Relay Setting Calculation in Renewable Power Systems Based on Parallel Graph Neural NetworkSource quoteL340: 39 │ 94.1% │ 96.5% │ 99.5% │ 99.6% │ 100% |
| 2025 | proposed analytical sensitivity formula (Eq. sensitivity) proposed | sensitivity D_beta | 12.5493 | split: test · beta=0.95 for generators; generated with InverseBeta (beta_0,k=0.95) for lines · perturbation=u_ij=√2/2 for lines (2,3) and (23,24); zero for remaining lines | Inverse Chance Constrained Optimal Power FlowSource quoteL224: The analytical sensitivity computed by \eqref{sensitivity} is 12.5493, |
| 2022 | RT-IFGSM (SAC-based UVLS model) proposed | AER | -27157.80 | split: test · model=SAC-based UVLS · access=white-box · attack=RT-IFGSM | Exploring the Vulnerability of Deep Reinforcement Learning-based Emergency Control for Low Carbon Power SystemsSource quoteL334: -27157.80 |
| 2022 | RT-IFGSM (SAC-based UVLS model) proposed | BRR | 0.394 | split: test · model=SAC-based UVLS · access=white-box · attack=RT-IFGSM | Exploring the Vulnerability of Deep Reinforcement Learning-based Emergency Control for Low Carbon Power SystemsSource quoteL335: 0.394 |
| 2022 | RT-IFGSM with DB-RDP defense (SAC-based UVLS model) proposed | AER | -8709.32 | split: test · model=SAC-based UVLS · access=white-box · attack=RT-IFGSM · defense=DB-RDP | Exploring the Vulnerability of Deep Reinforcement Learning-based Emergency Control for Low Carbon Power SystemsSource quoteL338: -8709.32 |
| 2022 | RT-IFGSM with DB-RDP defense (SAC-based UVLS model) proposed | BRR | 0.159 | split: test · model=SAC-based UVLS · access=white-box · attack=RT-IFGSM · defense=DB-RDP | Exploring the Vulnerability of Deep Reinforcement Learning-based Emergency Control for Low Carbon Power SystemsSource quoteL339: 0.159 |
| 2021 | SI-DNN proposed | Average Test MSE | 3.3 | split: test · mse-scale=×10^-3 · training-size=10 | Learning to Solve the AC-OPF using Sensitivity-Informed Deep Neural NetworksSource quoteL350: 10 │ 8.6 │ 738 │ 3.3 │ 746 |