IEEE 39-bus system

21 papers · 52 extracted observations · transient stability assessment · Markdown · CSV · JSON API

Also indexed as: ieee-39-bus-system

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

93.695.897.9100.0202120232025TrAdaBoost (Training dataset): 95.35 (2021)TrAdaBoost (augmented dataset): 95.44 (2021)PGNN (Parallel Graph Neural Network): 94.1 (2025)PGNN (Parallel Graph Neural Network): 100.0 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 5 of 5 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2021BCU + expansion (N=6) proposedCCT0.540model=lossless · fault-bus=3 · fault-type=three-phase short-circuit · expansion-iterations=6Approaching the Transient Stability Boundary of a Power System: Theory and Applications
Source quote
L457: 3 │ 23.42 │ 0.669 │ 16.15 │ 0.519 │ -22.40 │ 2.156 │ 0.528 │ -21.15 │ 0.047 │ 0.532 │ -20.53 │ 0.114 │ 0.540 │ -19.28 │ 0.269
2021Step-by-Step (SBS) trajectory simulation baselineCCT0.669model=lossless · fault-bus=3 · fault-type=three-phase short-circuitApproaching the Transient Stability Boundary of a Power System: Theory and Applications
Source quote
L457: 3 │ 23.42 │ 0.669 │ 16.15 │ 0.519 │ -22.40 │ 2.156 │ 0.528 │ -21.15 │ 0.047 │ 0.532 │ -20.53 │ 0.114 │ 0.540 │ -19.28 │ 0.269
2021BCU baselineCCT0.519model=lossless · fault-bus=3 · fault-type=three-phase short-circuitApproaching the Transient Stability Boundary of a Power System: Theory and Applications
Source quote
L457: 3 │ 23.42 │ 0.669 │ 16.15 │ 0.519 │ -22.40 │ 2.156 │ 0.528 │ -21.15 │ 0.047 │ 0.532 │ -20.53 │ 0.114 │ 0.540 │ -19.28 │ 0.269
2021Step-by-Step (SBS) trajectory simulation baselineCCT0.281model=lossy · fault-bus=3 · fault-type=three-phase short-circuitApproaching the Transient Stability Boundary of a Power System: Theory and Applications
Source quote
L517: 3 │ 13.18 │ 0.281 │ 9.60 │ 0.239 │ -14.89 │ 1.653 │ 0.248 │ -11.93 │ 0.013 │ 0.252 │ -10.45 │ 0.030 │ 0.264 │ -6.00 │ 0.063
2021BCU baselineCCT0.239model=lossy · fault-bus=3 · fault-type=three-phase short-circuitApproaching the Transient Stability Boundary of a Power System: Theory and Applications
Source quote
L517: 3 │ 13.18 │ 0.281 │ 9.60 │ 0.239 │ -14.89 │ 1.653 │ 0.248 │ -11.93 │ 0.013 │ 0.252 │ -10.45 │ 0.030 │ 0.264 │ -6.00 │ 0.063