IEEE 14-bus
14 papers · 30 extracted observations · power network topology control · Markdown · CSV · JSON API
Also indexed as: ieee-14-bus
Metricmean episode length (6)error rate (3)mean time s (2)average adp attack detection probability (2)computation time (2)ac power flow convergence rate conv (2)
Showing 3 of 3 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2017 | Regular LSE baseline | Mean-Square Estimation Error | 0.1434 | scenario=S3 | PSSE Redux: Convex Relaxation, Decentralized, Robust, and Dynamic ApproachesSource quoteL578: (S3) │ 0.0367 │ 0.1434 │ 0.0407 │ 0.0390 |
| 2017 | LNRT estimator (threshold 3.0) baseline | Mean-Square Estimation Error | 0.0407 | scenario=S3 · threshold=3.0 | PSSE Redux: Convex Relaxation, Decentralized, Robust, and Dynamic ApproachesSource quoteL578: (S3) │ 0.0367 │ 0.1434 │ 0.0407 │ 0.0390 |
| 2017 | Huber's estimator (λ=1.34) baseline | Mean-Square Estimation Error | 0.0390 | lambda=1.34 · scenario=S3 | PSSE Redux: Convex Relaxation, Decentralized, Robust, and Dynamic ApproachesSource quoteL578: (S3) │ 0.0367 │ 0.1434 │ 0.0407 │ 0.0390 |