fastMRI

86 papers · 287 extracted observations · mri reconstruction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

22.829.335.842.3202120242026A-DPS (proposed): 30.2 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 35.8 (2021)Joint-ICNet: 37.3 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 39.4 (2021)Joint-ICNet: 40.7 (2021)Deep Equilibrium (Grad): 32.01 (2021)CRR-NN: 40.95 (2023)LLS (\lambda=10 (-6)): 31.54 (2024)aSeqDIP: 34.08 (2024)Deform-Mamba (Our): 32.11 (2024)SAFI: 36.06 (2024)SAFI: 36.43 (2024)Interleaved (self-supervised loss added during training): 31.55 (2025)DEAL: 36.21 (2025)DEAL: 36.59 (2025)MFoE: 35.4 (2025)Distilled (on-policy privileged information distillation): 24.11 (2026)Distilled (on-policy privileged information distillation): 26.0 (2026)Distilled (on-policy privileged information distillation): 27.86 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 150 of 287 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Distilled (on-policy privileged information distillation) proposedPSNR27.86split: test · contrast=T1 · acceleration=R=32 · undersampling=Gaussian-VDNext-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction
Source quote
L344: Distilled │ 27.86 │ 22.29 │ 24.08 │ 0.81 │ 0.70 │ 0.67 │ 0.148 │ 0.161 │ 0.162
2026Distilled (on-policy privileged information distillation) proposedPSNR24.11split: test · contrast=T1 · acceleration=R=32 · undersampling=ES Cartesian-YNext-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction
Source quote
L354: Distilled │ 24.11 │ 18.42 │ 20.96 │ 0.74 │ 0.55 │ 0.57 │ 0.169 │ 0.230 │ 0.216
2026Distilled (on-policy privileged information distillation) proposedPSNR26.00split: test · contrast=T1 · acceleration=R=32 · undersampling=RadialNext-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction
Source quote
L359: Distilled │ 26.00 │ 20.51 │ 22.68 │ 0.78 │ 0.64 │ 0.63 │ 0.160 │ 0.196 │ 0.186
2026OCDI-Net proposedPSNR41.88SMS=MB3R1 · subset=T2 · reconstruction=single-stage SMS unaliasing · image-representation=RSS magnitudeBack to Physics: Operator-Guided Generative Paths for SMS MRI Reconstruction
Source quote
L619: OCDI-Net │ 41.88 │ 0.966 │ \boldsymbol{2.5× 10 (-3)}
2026OCDI-Net proposedSSIM0.966SMS=MB3R1 · subset=T2 · reconstruction=single-stage SMS unaliasing · image-representation=RSS magnitudeBack to Physics: Operator-Guided Generative Paths for SMS MRI Reconstruction
Source quote
L619: OCDI-Net │ 41.88 │ 0.966 │ \boldsymbol{2.5× 10 (-3)}
2026SGPnP-PGM (Decouple) proposedPSNR32.54acceleration=4x · noise-levels=decoupledStochastic Generative Plug-and-Play Priors
Source quote
L753: \multicolumn{1}{c}{\hlgreen{32.91}} │ \multicolumn{1}{c}{31.44} │ \multicolumn{1}{c}{\hlgreen{33.32}} │ \multicolumn{1}{c}{30.20} │ \multicolumn{1}{c}{\hlgreen{32.54}} \\[+.95ex]
2026EvoML proposedSSIM0.9498split: test · supervisedValidation-Gated ML Pipeline Synthesis with Expert-Grounded Self-Evolving Skills
Source quote
L975: The margin is largest on the harder tasks, reaching 0.9498
2026GEO proposedSSFD6.67anatomy=brain · acceleration=×8Anatomical Token Uncertainty for Transformer-Guided Active MRI Acquisition
Source quote
L104: GEO (Ours) │ Transformer │ 27.26 │ 0.6783 │ 0.0407 │ 2.96 │ 0.13 │ 6.67
2026GEO proposedSSFD8.82anatomy=knee · acceleration=×16Anatomical Token Uncertainty for Transformer-Guided Active MRI Acquisition
Source quote
L96: GEO (Ours) │ Transformer │ 28.61 │ 0.5983 │ 0.0653 │ 4.11 │ 0.18 │ 8.82
2026PAS-Mamba proposedPSNR32.46Radial mask, ×2 acceleration.PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI Reconstruction
Source quote
L241: Ours │ 32.46 │ 0.8838 │ 28.84 │ 0.8301
2026PAS-Mamba proposedSSIM0.8838Radial mask, ×2 acceleration.PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI Reconstruction
Source quote
L241: Ours │ 32.46 │ 0.8838 │ 28.84 │ 0.8301
2026PAS-Mamba proposedPSNR26.47Cartesian mask, ×4 acceleration.PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI Reconstruction
Source quote
L249: Ours │ 28.35 │ 0.7058 │ 26.47 │ 0.7081
2026PAS-Mamba proposedSSIM0.7081Cartesian mask, ×4 acceleration.PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI Reconstruction
Source quote
L249: Ours │ 28.35 │ 0.7058 │ 26.47 │ 0.7081
2026No cross-attention ablationPSNR37.92SMS=MB3R1 · subset=T2 · variant=no cross-attention · reconstruction=single-stage SMS unaliasing · image-representation=RSS magnitudeBack to Physics: Operator-Guided Generative Paths for SMS MRI Reconstruction
Source quote
L618: No cross-attention │ 37.92 │ 0.949 │ 6.6× 10 (-3)
2026No cross-attention ablationSSIM0.949SMS=MB3R1 · subset=T2 · variant=no cross-attention · reconstruction=single-stage SMS unaliasing · image-representation=RSS magnitudeBack to Physics: Operator-Guided Generative Paths for SMS MRI Reconstruction
Source quote
L618: No cross-attention │ 37.92 │ 0.949 │ 6.6× 10 (-3)
2026SGPnP-PGM (Match) ablationPSNR30.20acceleration=4x · noise-levels=matchedStochastic Generative Plug-and-Play Priors
Source quote
L753: \multicolumn{1}{c}{\hlgreen{32.91}} │ \multicolumn{1}{c}{31.44} │ \multicolumn{1}{c}{\hlgreen{33.32}} │ \multicolumn{1}{c}{30.20} │ \multicolumn{1}{c}{\hlgreen{32.54}} \\[+.95ex]
2026PUERT baselineSSFD7.15anatomy=brain · acceleration=×8Anatomical Token Uncertainty for Transformer-Guided Active MRI Acquisition
Source quote
L101: PUERT~\cite{puert} │ ISTA-Unfold~\cite{ista} │ 30.73 │ 0.8219 │ 0.0185 │ 4.33 │ 0.29 │ 7.15
2026PUERT baselineSSFD14.75anatomy=knee · acceleration=×16Anatomical Token Uncertainty for Transformer-Guided Active MRI Acquisition
Source quote
L119: Quantitative Performance. Table \ref{tab:consolidated_results} shows that baselines such as PUERT consistently achieve higher PSNR and SSIM than our methods. For example, on fastMRI Knee at ×8, PUERT reaches 33.63 dB PSNR (vs.\ \sim30.2 dB for LES/GEO), and AdaSense also maintains higher PSNR (31.19 dB). A similar trend is seen across Knee/Brain at both ×8 and ×16 accelerations, while our policies consistently achieve the best perceptual and feature-based metrics (LPIPS, DISTS, SSFD). On fastMRI Knee at ×16, LES and GEO achieve an SSFD of 8.82, outperforming PUERT (14.75; 40.2% reduction), LOUPE (13.91; 36.6% reduction), and AdaSense (14.29; 38.3% reduction). At Knee ×8, LES/GEO achieve LPIPS scores of \sim3.70, improving over PUERT (5.25; \sim29.5% lower) and AdaSense (4.68; \sim20.9% lower)~\cite{puert,adasense}. In the Brain dataset, GEO reaches the best SSFD of 6.67 at ×8, improving over PUERT (7.15; 6.7% lower) and Ada-Sel (8.95; 25.5% reduction).
2026PUERT baselineLPIPS5.25anatomy=knee · acceleration=×8Anatomical Token Uncertainty for Transformer-Guided Active MRI Acquisition
Source quote
L119: Quantitative Performance. Table \ref{tab:consolidated_results} shows that baselines such as PUERT consistently achieve higher PSNR and SSIM than our methods. For example, on fastMRI Knee at ×8, PUERT reaches 33.63 dB PSNR (vs.\ \sim30.2 dB for LES/GEO), and AdaSense also maintains higher PSNR (31.19 dB). A similar trend is seen across Knee/Brain at both ×8 and ×16 accelerations, while our policies consistently achieve the best perceptual and feature-based metrics (LPIPS, DISTS, SSFD). On fastMRI Knee at ×16, LES and GEO achieve an SSFD of 8.82, outperforming PUERT (14.75; 40.2% reduction), LOUPE (13.91; 36.6% reduction), and AdaSense (14.29; 38.3% reduction). At Knee ×8, LES/GEO achieve LPIPS scores of \sim3.70, improving over PUERT (5.25; \sim29.5% lower) and AdaSense (4.68; \sim20.9% lower)~\cite{puert,adasense}. In the Brain dataset, GEO reaches the best SSFD of 6.67 at ×8, improving over PUERT (7.15; 6.7% lower) and Ada-Sel (8.95; 25.5% reduction).
2026LOUPE baselineAUROC0.9064anatomy=knee · diagnosis=meniscal tears, ACL sprains, and abnormality · acceleration=32xInformation-Theoretic Optimization for Task-Adapted Compressed Sensing Magnetic Resonance Imaging
Source quote
L738: LOUPE │ 26.20 │ 0.9129 │ 24.85 │ 0.9064
2025SDUM proposedPSNR42.6 dBcoils=multi-coil · anatomy=brain · acceleration=4× · unrolling-steps=6SDUM: A Scalable Deep Unrolled Model for Universal MRI Reconstruction
Source quote
L403: SDUM (Ours) │ 0.979 │ \multicolumn{1}{c|}{42.6} │ 0.973 │ 40.8
2025PR-INR proposedPSNR33.3 dBmotion-displacement=3%From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction
Source quote
L617: Table~\ref{tab:ablation_final} shows that the full configuration of our PR-INR framework consistently achieves the best performance across all undersampling settings on both the FastMRI and HCP 1200 datasets. At 3% and 5% displacement during acquisition, the complete model achieves strong gains over the baseline. For instance, PSNR/SSIM improves from 30.0/0.853 to 33.3/0.919 on FastMRI, and from 24.3/0.820 to 27.0/0.904 on HCP 1200 at 3%, with similar trends at 5%. Under 4x and 8x undersampling, PR-INR remains robust, consistently outperforming variants. At 8x, it improves PSNR from 23.9 to 26.4 and SSIM from 0.645 to 0.721 on FastMRI, and shows comparable improvements on HCP. The IDR module plays a key role in enhancing perceptual and structural quality (e.g., LPIPS drops and SSIM improves), while the VCR module further enforces volumetric smoothness, reflected in higher NCC values. These results validate the complementary contributions of each module and the generalizability of PR-INR across different datasets and acceleration regimes.
2025PR-INR proposedSSIM0.919motion-displacement=3%From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction
Source quote
L617: Table~\ref{tab:ablation_final} shows that the full configuration of our PR-INR framework consistently achieves the best performance across all undersampling settings on both the FastMRI and HCP 1200 datasets. At 3% and 5% displacement during acquisition, the complete model achieves strong gains over the baseline. For instance, PSNR/SSIM improves from 30.0/0.853 to 33.3/0.919 on FastMRI, and from 24.3/0.820 to 27.0/0.904 on HCP 1200 at 3%, with similar trends at 5%. Under 4x and 8x undersampling, PR-INR remains robust, consistently outperforming variants. At 8x, it improves PSNR from 23.9 to 26.4 and SSIM from 0.645 to 0.721 on FastMRI, and shows comparable improvements on HCP. The IDR module plays a key role in enhancing perceptual and structural quality (e.g., LPIPS drops and SSIM improves), while the VCR module further enforces volumetric smoothness, reflected in higher NCC values. These results validate the complementary contributions of each module and the generalizability of PR-INR across different datasets and acceleration regimes.
2025PR-INR proposedPSNR28.9 dBacceleration=4×From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction
Source quote
L563: {Table~\ref{tab:motion} shows that our PR-INR outperforms state-of-the-art MRI reconstruction methods under both 4× and 8× acceleration on the fastMRI and HCP1200 datasets.} The model maintains superior image quality and structural consistency despite reduced sampling, indicating its capacity to restore high-frequency details and suppress undersampling artifacts. It achieves the highest PSNR (28.9/26.4 dB on fastMRI, 26.4/24.0 dB on HCP1200) and SSIM (0.887/0.721 on fastMRI, 0.895/0.849 on HCP1200), indicating superior reconstruction quality and perceptual fidelity. Fig.~\ref{fig4} (c) and (d) further demonstrate the advantages of PR-INR in visual quality. Compared to baseline models, our method reconstructs sharper anatomical boundaries and suppresses noise and artifacts. The zoomed-in regions especially highlight its ability to retain fine-grained features and maintain consistency with ground truth images.
2025PR-INR proposedPSNR26.4 dBacceleration=8×From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction
Source quote
L563: {Table~\ref{tab:motion} shows that our PR-INR outperforms state-of-the-art MRI reconstruction methods under both 4× and 8× acceleration on the fastMRI and HCP1200 datasets.} The model maintains superior image quality and structural consistency despite reduced sampling, indicating its capacity to restore high-frequency details and suppress undersampling artifacts. It achieves the highest PSNR (28.9/26.4 dB on fastMRI, 26.4/24.0 dB on HCP1200) and SSIM (0.887/0.721 on fastMRI, 0.895/0.849 on HCP1200), indicating superior reconstruction quality and perceptual fidelity. Fig.~\ref{fig4} (c) and (d) further demonstrate the advantages of PR-INR in visual quality. Compared to baseline models, our method reconstructs sharper anatomical boundaries and suppresses noise and artifacts. The zoomed-in regions especially highlight its ability to retain fine-grained features and maintain consistency with ground truth images.
2025Interleaved (self-supervised loss added during training) proposedPSNR31.55split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brainBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L283: Interleaved │ 31.55 │ .7910
2025Interleaved (self-supervised loss added during training) proposedSSIM.7910split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brainBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L283: Interleaved │ 31.55 │ .7910
2025DEAL proposedPSNR36.59split: test · coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32
2025DEAL proposedPSNR36.21split: test · coils=multi-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=8-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32
2025RFJS proposedPSNR (↑)25.85ACS=2% · coils=multi-coil · anatomy=knee · contrast=PDFS with PD · acceleration_factor=16Inference-Time Search Using Side Information for Diffusion-Based Image Reconstruction
Source quote
L1040: RFJS │ 25.85 │ 0.801 │ 0.375 │ 0.457
2025SelfDB proposedNRMSE0.108split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L137: SelfDB │ 0.108 │ 0.882 │ 0.036
2025SelfDB proposedSSIM0.882split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L137: SelfDB │ 0.108 │ 0.882 │ 0.036
2025SelfDB proposedLPIPS0.036split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L137: SelfDB │ 0.108 │ 0.882 │ 0.036
2025C-MSM proposed non-standard slicePSNR32.7split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L179: C\text{-}MSM │ \hlblue{32.7} │ 0.853 │ \hlgreen{0.144} [2pt] \cdashline{1-5} [2pt]
2025C-MSM proposed non-standard slicePSNR28.8split: test · acs-lines=20 · acceleration=×8 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L187: C\text{-}MSM │ \hlgreen{28.8} │ \hlblue{0.760} │ 0.265
2025C-MSM proposed non-standard sliceLPIPS0.144split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L179: C\text{-}MSM │ \hlblue{32.7} │ 0.853 │ \hlgreen{0.144} [2pt] \cdashline{1-5} [2pt]
2025GTF²M (ours; unsupervised prior-learning method) proposedNFEs20coil=single-coil · sampling=random-uniform · acceleration=4x and 8xUnsupervised Accelerated MRI Reconstruction via Ground-Truth-Free Flow Matching
Source quote
L366: Ours │ \magenta{0.801±0.073} │ \magenta{0.688±0.095} │ \magenta{31.64±2.95} │ \magenta{27.95±2.64} │ 20
2025HiFi-MambaV2 (P1) proposedSSIM0.855Equispaced sampling; acceleration factor ×4HiFi-MambaV2: Hierarchical Shared-Routed MoE for High-Fidelity MRI Reconstruction
Source quote
L295: On fastMRI, V2(P1) attains 34.86\,dB/0.855 SSIM at 4× and 31.89\,dB/0.764 SSIM at 8×, outperforming LMO by +0.37\,dB/+0.011 and +0.79\,dB/+0.020, respectively.
2025HiFi-MambaV2 (P1) proposedSSIM0.764Equispaced sampling; acceleration factor ×8HiFi-MambaV2: Hierarchical Shared-Routed MoE for High-Fidelity MRI Reconstruction
Source quote
L295: On fastMRI, V2(P1) attains 34.86\,dB/0.855 SSIM at 4× and 31.89\,dB/0.764 SSIM at 8×, outperforming LMO by +0.37\,dB/+0.011 and +0.79\,dB/+0.020, respectively.
2025MFoE proposedPSNR35.40split: test · noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4Multivariate Fields of Experts
Source quote
L327: MFoE │ 35.40 │ 34.21 │ 30.26 │ 31.20
2025Ours (uCMS + IrR) proposedPSNR27.97scale-factor=4× · reconstruction=2D slice-basedDecoupling Multi-Contrast Super-Resolution: Pairing Unpaired Synthesis with Implicit Representations
Source quote
L248: 27.97
2025HiFi-Mamba (P1) proposed non-standard slicePSNR34.85 dBsubset=PDFS single-coil knee · patch-size=1 · undersampling=equispaced 1D Cartesian · acceleration-factor=4HiFi-Mamba: Dual-Stream 𝒲 -Laplacian Enhanced Mamba for High-Fidelity MRI Reconstruction
Source quote
L285: The finer-grained variant HiFi-Mamba (P1), with a patch size of 1, further improves reconstruction performance, establishing a new state-of-the-art. Specifically, it achieves 34.85 / 31.81 dB PSNR and 0.855 / 0.762 SSIM on fastMRI (\text{AF}=4 / 8), with corresponding NMSE of 0.010 / 0.020. On CC359, it achieves 36.93 dB PSNR and 0.942 SSIM at \text{AF}=4, and maintains robust performance at \text{AF}=8, reaching 28.49 dB PSNR, 0.810 SSIM, and 0.026 NMSE, consistently surpassing prior state-of-the-art methods across all metrics.
2025HiFi-Mamba (P1) proposed non-standard slicePSNR31.81 dBsubset=PDFS single-coil knee · patch-size=1 · undersampling=equispaced 1D Cartesian · acceleration-factor=8HiFi-Mamba: Dual-Stream 𝒲 -Laplacian Enhanced Mamba for High-Fidelity MRI Reconstruction
Source quote
L285: The finer-grained variant HiFi-Mamba (P1), with a patch size of 1, further improves reconstruction performance, establishing a new state-of-the-art. Specifically, it achieves 34.85 / 31.81 dB PSNR and 0.855 / 0.762 SSIM on fastMRI (\text{AF}=4 / 8), with corresponding NMSE of 0.010 / 0.020. On CC359, it achieves 36.93 dB PSNR and 0.942 SSIM at \text{AF}=4, and maintains robust performance at \text{AF}=8, reaching 28.49 dB PSNR, 0.810 SSIM, and 0.026 NMSE, consistently surpassing prior state-of-the-art methods across all metrics.
2025HiFi-Mamba (P2) proposedPSNR31.38 dBGPU=NVIDIA A100 · FLOPs=67.87G · patch-size=2 · resolution=320×320 · acceleration-factor=8HiFi-Mamba: Dual-Stream 𝒲 -Laplacian Enhanced Mamba for High-Fidelity MRI Reconstruction
Source quote
L302: HiFi-Mamba (P2) achieves 31.38\,dB PSNR and 0.758 SSIM with only 67.87G FLOPs—substantially lower than all competing models, while matching or surpassing heavier attention-based architectures such as ReconFormer and FpsFormer.
2025Proposed BED procedure proposedPSNR16.0957subset=brain · iteration=1 · k-space-sampled=3.3659%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L210: 1 │ 16.0957 │ 0.7890 │ 3.3659
2025Proposed BED procedure proposedSSIM0.7890subset=brain · iteration=1 · k-space-sampled=3.3659%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L210: 1 │ 16.0957 │ 0.7890 │ 3.3659
2025Proposed BED procedure proposedPSNR20.6784subset=brain · iteration=9 · k-space-sampled=15.6789%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L214: 9 │ 20.6784 │ 0.9104 │ 15.6789
2025Proposed BED procedure proposedSSIM0.9104subset=brain · iteration=9 · k-space-sampled=15.6789%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L214: 9 │ 20.6784 │ 0.9104 │ 15.6789
2025Supervised learning baseline non-standard slicePSNR32.68split: test · anatomy=knee · training=supervised with oracle ground truth · acceleration=6xBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L414: (Supervised) │ (32.68) │ (.8141)
2025Supervised learning baseline non-standard sliceSSIM.8141split: test · anatomy=knee · training=supervised with oracle ground truth · acceleration=6xBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L414: (Supervised) │ (32.68) │ (.8141)
2025SAFI baselinePSNR36.43split: test · coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L354: SAFI │ 36.43 │ 34.92 │ 36.06 │ 35.36
2025SAFI baselinePSNR36.06split: test · coils=multi-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=8-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L354: SAFI │ 36.43 │ 34.92 │ 36.06 │ 35.36
2025ContextMRI baselinePSNR (↑)25.39ACS=2% · coils=multi-coil · anatomy=knee · contrast=PDFS with PD · acceleration_factor=16Inference-Time Search Using Side Information for Diffusion-Based Image Reconstruction
Source quote
L1043: ContextMRI │ 25.39 │ 0.795 │ 0.383 │ 0.451
2025C-Ambient-DDM baselineNRMSE0.113split: test · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L136: C-Ambient-DDM │ 0.113 │ 0.833 │ 0.056
2025C-Ambient-DDM baselineSSIM0.833split: test · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L136: C-Ambient-DDM │ 0.113 │ 0.833 │ 0.056
2025C-Ambient-DDM baselineLPIPS0.056split: test · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L136: C-Ambient-DDM │ 0.113 │ 0.833 │ 0.056
2025DDNM baselinePSNR32.9split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L178: DDNM │ \hlgreen{32.9} │ \hlgreen{0.864} │ \hlblue{0.159}
2025DDNM baselinePSNR28.6split: test · acs-lines=20 · acceleration=×8 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L186: DDNM │ \hlblue{28.6} │ \hlgreen{0.764} │ \hlblue{0.249}
2025DDNM baselineLPIPS0.159split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L178: DDNM │ \hlgreen{32.9} │ \hlgreen{0.864} │ \hlblue{0.159}
2025FlowPS baselineNFEs100coil=single-coil · sampling=random-uniform · acceleration=4x and 8xUnsupervised Accelerated MRI Reconstruction via Ground-Truth-Free Flow Matching
Source quote
L358: FlowPS \cite{journal/tmlr/pokle2024} │ 0.763±0.077* │ 0.631±0.101* │ 30.66±2.73* │ 26.30±2.55* │ 100
2025E2E-VarNet baselinePrecision0.610split: test · subset=severe-pathology · detector=YOLOv11InverseBench: Benchmarking Plug-and-Play Diffusion Priors for Inverse Problems in Physical Sciences
Source quote
L439: E2E-VarNet │ 0.610 │ 0.514 │ 0.500 │ 1 │ 32.25 (1.901) │ 0.805 (0.056) │ -- │ 1
2025E2E-VarNet baselinemAP500.500split: test · subset=severe-pathology · detector=YOLOv11InverseBench: Benchmarking Plug-and-Play Diffusion Priors for Inverse Problems in Physical Sciences
Source quote
L439: E2E-VarNet │ 0.610 │ 0.514 │ 0.500 │ 1 │ 32.25 (1.901) │ 0.805 (0.056) │ -- │ 1
2025PnP-DM baselineRecall0.579split: test · subset=severe-pathology · detector=YOLOv11InverseBench: Benchmarking Plug-and-Play Diffusion Priors for Inverse Problems in Physical Sciences
Source quote
L447: PnP-DM │ 0.527 │ 0.579 │ 0.500 │ 1 │ 29.85 (2.934) │ 0.730 (0.056) │ 24.324 (10.413) │ 5
2025PnP-DM baselinemAP500.500split: test · subset=severe-pathology · detector=YOLOv11InverseBench: Benchmarking Plug-and-Play Diffusion Priors for Inverse Problems in Physical Sciences
Source quote
L447: PnP-DM │ 0.527 │ 0.579 │ 0.500 │ 1 │ 29.85 (2.934) │ 0.730 (0.056) │ 24.324 (10.413) │ 5
2025Prox-DRUNet baselinePSNR35.32split: test · noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4Multivariate Fields of Experts
Source quote
L328: Prox-DRUNet │ 35.32 │ 34.53 │ 30.97 │ 31.66
2025ADS baselinemean SSIM91.26split: test · subset=knee · k-space-subsampling=25%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L227: ADS \citep{nolan2024} │ 91.26
2024Nila (Nila-DC) proposedPSNR37.08split: val · noise=none · acceleration=6×Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRI
Source quote
L124: Nila (ours) │ \textcolor{red}{37.08} │ \textcolor{red}{95.74} │ \textcolor{red}{34.82} │ \textcolor{red}{94.21} │ \textcolor{red}{36.10} │ \textcolor{red}{94.34} │ \textcolor{red}{33.54} │ \textcolor{red}{91.55} │ \textcolor{red}{30.23} │ \textcolor{red}{91.59} │ \textcolor{red}{29.86} │ \textcolor{red}{90.06}
2024Nila (Nila-DC) proposedPSNR31.86split: val · noise=Gaussian σ=0.1 · acceleration=6×Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRI
Source quote
L145: Nila (ours) │ \textcolor{red}{34.98} │ \textcolor{red}{93.96} │ \textcolor{red}{33.56} │ \textcolor{red}{92.49} │ \textcolor{red}{31.86} │ \textcolor{red}{90.38} │ \textcolor{red}{34.11} │ \textcolor{red}{91.53} │ \textcolor{red}{32.80} │ \textcolor{red}{89.59} │ \textcolor{red}{31.25} │ \textcolor{red}{87.15}
2024IR-FRestormerF proposedSSIM0.9427split: test · coil=multi-coil · anatomy=brain · ensemble=flip · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L265: 0.9427
2024aSeqDIP proposedPSNR34.08split: test · undersampling=4× · averaged-scans=20Image Reconstruction Via Autoencoding Sequential Deep Image Prior
Source quote
L533: 34.08
2024Policy Classifier proposedAUC0.789sample_rate=7% · center_fraction=0.01The MRI Scanner as a Diagnostic: Image-less Active Sampling
Source quote
L183: 0.717 │ 0.789 │ 0.785 │ 0.784 │ 0.775 │ 0.794 │ 0.752 │ 0.755 │ 0.739 │ 0.742 │ 0.741 │ 0.743
2024Policy Classifier proposedAUC0.794sample_rate=25% · center_fraction=0.01The MRI Scanner as a Diagnostic: Image-less Active Sampling
Source quote
L183: 0.717 │ 0.789 │ 0.785 │ 0.784 │ 0.775 │ 0.794 │ 0.752 │ 0.755 │ 0.739 │ 0.742 │ 0.741 │ 0.743
2024DiffMSR proposedDiffusion iteration steps4 stepsThe FastMRI comparison uses the experimental settings referenced in the caption; the pa…Rethinking Diffusion Model for Multi-Contrast MRI Super-Resolution
Source quote
L10: \caption{Comparison with DM-based MRI reconstruction methods on FastMRI dataset. Note that the experimental settings used by these methods are the same as those in Sec. \ref{exper}. As can be seen, our method has the best reconstruction metric and it only requires 4 iteration steps. Note that DiffuseRecon \cite{peng2022towards}, MC-DDPM \cite{xie2022measurement}, Score-MRI \cite{chung2022score}, and AdaDiff \cite{gungor2023adaptive} are employed for single-contrast SR (SCSR) reconstruction. DisC-Diff \cite{mao2023disc} is specifically designed for multi-contrast SR (MCSR) reconstruction.}
2024ADS proposedSSIM91.26split: test · resolution=128×128 · acceleration=4× · sampling-fraction=25%Active Diffusion Subsampling
Source quote
L251: While ADS appears to outperform fixed-mask baselines on MNIST, CelebA, and fastMRI, it is interesting to note that the relative improvement offered by ADS is less pronounced in the case of fastMRI. For line-based image subsampling on MNIST with 25% samples, ADS achieves a 50% reduction in reconstruction error versus a fixed-mask approach (MAE = 0.019 vs 0.037), whereas with line-based \kappa-space subsampling for fastMRI with 25% samples, ADS achieves only a 12% relative improvement (SSIM = 91.26 vs 90.13). We find that the size of this performance gap between fixed and active mask design strategies can be explained by examining the distribution of masks designed by ADS on each task (See Appendix \ref{appendix:mask-distributions}). Indeed, the masks designed for fastMRI are very similar, whereas those designed for MNIST typically differ depending on the sample. When mask designs are similar, then fixed masks will perform similarly to actively designed masks. This is in part a feature of the data distribution -- for example, most information in \kappa-space is contained in the center, at lower frequencies. Tasks in which one might expect significantly better performance from ADS are therefore those in which optimal masks will be highly sample-dependent.
2024SPGD Jittering proposed non-standard slicePSNR27.56evaluation=adversarial attack · acceleration=4×SGD Jittering: A Training Strategy for Robust and Accurate Model-Based Architectures
Source quote
L421: PSNR / SSIM │ fastMRI │ Adv. Attack │ Tumor Cell MSE training │ 27.93 / 0.582 │ 22.82 / 0.179 │ 29.39 / 0.771 AT │ 27.20 / 0.533 │ 26.78 / 0.518 │ 27.13 / 0.560 Input Jittering │ 24.88 / 0.299 │ 24.44 / 0.297 │ 25.85 / 0.478 SPGD Jittering │ 28.15 / 0.597 │ 27.56 / 0.577 │ 29.762 / 0.777
2024Deform-Mamba (Our) proposedPSNR32.11split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965
2024Deform-Mamba (Our) proposedSSIM0.7194split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965
2024FasterFC-U-Net proposedPSNR31.87subset=knee, single-coil · sampling=random Cartesian · acceleration=4Image Reconstruction for Accelerated MR Scan With Faster Fourier Convolutional Neural Networks
Source quote
L1185: 31.87
2024FasterFC-E2E-VarNet proposedPSNR39.05subset=knee, multi-coil · cascades=4 · sampling=random Cartesian · acceleration=4Image Reconstruction for Accelerated MR Scan With Faster Fourier Convolutional Neural Networks
Source quote
L1227: 0.0059 39.05 0.9165
2024Self-Guided DIP (Generalized) proposedAverage reconstruction PSNR31.77 dBsplit: test · anatomy=knee · variant=Generalized · acceleration=4x · average-images=15Analysis of Deep Image Prior and Exploiting Self-Guidance for Image Reconstruction
Source quote
L627: 31.77
2024DAPS proposedPSNR31.48subset=knee · resolution=320x320 · acceleration=4x · diffusion-model=EDMImproving Diffusion Inverse Problem Solving with Decoupled Noise Annealing
Source quote
L199: DAPS │ 31.48 │ 0.762 │ 1.57 │ 29.01 │ 0.681 │ 1.28
2024DAPS proposedPSNR29.01subset=knee · resolution=320x320 · acceleration=8x · diffusion-model=EDMImproving Diffusion Inverse Problem Solving with Decoupled Noise Annealing
Source quote
L199: DAPS │ 31.48 │ 0.762 │ 1.57 │ 29.01 │ 0.681 │ 1.28
2024HQS (Cheb preconditioner) proposedPSNR34.521acceleration-factor=4Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI Reconstruction
Source quote
L185: HQS │ 34.521 │ 33.251 │ 0.917 │ 0.902
2024HQS (Cheb preconditioner) proposedPSNR33.251acceleration-factor=16Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI Reconstruction
Source quote
L185: HQS │ 34.521 │ 33.251 │ 0.917 │ 0.902
2024HQS (Cheb preconditioner) proposedSSIM0.902acceleration-factor=16Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI Reconstruction
Source quote
L185: HQS │ 34.521 │ 33.251 │ 0.917 │ 0.902
2024SAFI proposedPSNR36.43split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=4-fold · coil-setting=single-coil · patch-resolution=320×320Iteratively Refined Image Reconstruction with Learned Attentive Regularizers
Source quote
L790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860
2024SAFI proposedPSNR36.06split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=8-fold · coil-setting=multi-coil · patch-resolution=320×320Iteratively Refined Image Reconstruction with Learned Attentive Regularizers
Source quote
L790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860
2024TC-KANRecon proposedPSNR30.50acceleration-factor=4TC-KANRecon: High-Quality and Accelerated MRI Reconstruction via Adaptive KAN Mechanisms and Intelligent Feature Scaling
Source quote
L209: TC-KANRecon (Ours) │ 30.50 │ 29.16 │ 27.93 │ 26.83 │ 0.817 │ 0.691 │ 0.624 │ 0.593 │ 0.0211 │ 0.0273 │ 0.0309 │ 0.0371
2024TC-KANRecon proposedSSIM0.817acceleration-factor=4TC-KANRecon: High-Quality and Accelerated MRI Reconstruction via Adaptive KAN Mechanisms and Intelligent Feature Scaling
Source quote
L209: TC-KANRecon (Ours) │ 30.50 │ 29.16 │ 27.93 │ 26.83 │ 0.817 │ 0.691 │ 0.624 │ 0.593 │ 0.0211 │ 0.0273 │ 0.0309 │ 0.0371
2024TC-KANRecon proposedNMSE0.0211acceleration-factor=4TC-KANRecon: High-Quality and Accelerated MRI Reconstruction via Adaptive KAN Mechanisms and Intelligent Feature Scaling
Source quote
L209: TC-KANRecon (Ours) │ 30.50 │ 29.16 │ 27.93 │ 26.83 │ 0.817 │ 0.691 │ 0.624 │ 0.593 │ 0.0211 │ 0.0273 │ 0.0309 │ 0.0371
2024CSGM baselinePSNR35.04split: val · noise=none · acceleration=6×Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRI
Source quote
L121: CSGM │ \textcolor{blue}{35.04} │ \textcolor{blue}{93.53} │ \textcolor{blue}{32.11} │ \textcolor{blue}{90.78} │ \textcolor{blue}{34.67} │ \textcolor{blue}{92.65} │ \textcolor{blue}{31.57} │ \textcolor{blue}{88.94} │ 26.73 │ 84.53 │ 25.63 │ 82.78
2024Spreco baselinePSNR25.89split: val · noise=Gaussian σ=0.1 · acceleration=6×Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRI
Source quote
L143: Spreco │ \textcolor{blue}{31.31} │ \textcolor{blue}{89.03} │ \textcolor{blue}{29.62} │ \textcolor{blue}{84.93} │ \textcolor{blue}{25.89} │ \textcolor{blue}{74.23} │ 31.32 │ \textcolor{blue}{88.03} │ \textcolor{blue}{29.58} │ \textcolor{blue}{83.88} │ \textcolor{blue}{26.41} │ 74.10
2024DIRCN [28] baselineSSIM0.9455split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L262: 0.9455
2024E2E-VarNet [34] baselineSSIM0.9426split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L268: 0.9426
2024XPDNet [31] baselineSSIM0.9408split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L271: 0.9408
2024HQS-Net [41] baselineSSIM0.9400split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L274: 0.9400
2024U-Net [46] baselineSSIM0.9282split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L277: 0.9282
2024E2E VarNet (trained on 8000 data points from fastMRI) baselinePSNR34.89split: test · training-data=8000 data points · undersampling=4×Image Reconstruction Via Autoencoding Sequential Deep Image Prior
Source quote
L528: 34.89
2024Undersampled baselineAUC0.761sample_rate=7% · center_fraction=0.01 · sampling_strategy=random k-space linesThe MRI Scanner as a Diagnostic: Image-less Active Sampling
Source quote
L178: Undersampled │ 0.666 │ 0.689 │ 0.710 │ 0.736 │ 0.745 │ 0.756 │ 0.729 │ 0.761 │ 0.789 │ 0.764 │ 0.776 │ 0.783 │ 0.752 │ 0.751 │ 0.747 │ 0.745 │ 0.743 │ 0.749
2024Oracle baseline non-standard sliceAUC0.819data_fidelity=high-fidelityThe MRI Scanner as a Diagnostic: Image-less Active Sampling
Source quote
L177: Oracle │ 0.819 │ 0.819 │ 0.819 │ 0.819 │ 0.819 │ 0.819 │ 0.819 │ 0.819 │ 0.819 │ 0.819 │ 0.819 │ 0.819 │ 0.819 │ 0.819 │ 0.819 │ 0.819 │ 0.819
2024Fixed-mask DPS baselineSSIM90.13split: test · resolution=128×128 · acceleration=4× · sampling-fraction=25%Active Diffusion Subsampling
Source quote
L251: While ADS appears to outperform fixed-mask baselines on MNIST, CelebA, and fastMRI, it is interesting to note that the relative improvement offered by ADS is less pronounced in the case of fastMRI. For line-based image subsampling on MNIST with 25% samples, ADS achieves a 50% reduction in reconstruction error versus a fixed-mask approach (MAE = 0.019 vs 0.037), whereas with line-based \kappa-space subsampling for fastMRI with 25% samples, ADS achieves only a 12% relative improvement (SSIM = 91.26 vs 90.13). We find that the size of this performance gap between fixed and active mask design strategies can be explained by examining the distribution of masks designed by ADS on each task (See Appendix \ref{appendix:mask-distributions}). Indeed, the masks designed for fastMRI are very similar, whereas those designed for MNIST typically differ depending on the sample. When mask designs are similar, then fixed masks will perform similarly to actively designed masks. This is in part a feature of the data distribution -- for example, most information in \kappa-space is contained in the center, at lower frequencies. Tasks in which one might expect significantly better performance from ADS are therefore those in which optimal masks will be highly sample-dependent.
2024AdaDiff baselinePSNR37.2coil=single · acceleration=R=8xDiffusion Models in Low-Level Vision: A Survey
Source quote
L622: AdaDiff\cite{AdaDiff-gungor2023adaptive} │ 40.2 │ 0.96 │ 37.2 │ 0.94 │ 10.2157 │ 39.72
2024MSE training baseline non-standard slicePSNR22.82evaluation=adversarial attack · acceleration=4×SGD Jittering: A Training Strategy for Robust and Accurate Model-Based Architectures
Source quote
L421: PSNR / SSIM │ fastMRI │ Adv. Attack │ Tumor Cell MSE training │ 27.93 / 0.582 │ 22.82 / 0.179 │ 29.39 / 0.771 AT │ 27.20 / 0.533 │ 26.78 / 0.518 │ 27.13 / 0.560 Input Jittering │ 24.88 / 0.299 │ 24.44 / 0.297 │ 25.85 / 0.478 SPGD Jittering │ 28.15 / 0.597 │ 27.56 / 0.577 │ 29.762 / 0.777
2024T (2)Net baselinePSNR30.56split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L178: T (2)Net │ 30.56 │ 0.6244 │ 29.73 │ 0.8773
2024T (2)Net baselineSSIM0.6244split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L178: T (2)Net │ 30.56 │ 0.6244 │ 29.73 │ 0.8773
2024FFC-U-Net baselinePSNR31.85subset=knee, single-coil · sampling=random Cartesian · acceleration=4Image Reconstruction for Accelerated MR Scan With Faster Fourier Convolutional Neural Networks
Source quote
L1175: 31.85
2024E2E-VarNet baselinePSNR38.75subset=knee, multi-coil · cascades=4 · sampling=random Cartesian · acceleration=4Image Reconstruction for Accelerated MR Scan With Faster Fourier Convolutional Neural Networks
Source quote
L1220: 0.0062 38.75 0.9149
2024Vanilla DIP (Generalized) baselineAverage reconstruction PSNR28.2 dBsplit: test · anatomy=knee · variant=Generalized · acceleration=4x · average-images=15Analysis of Deep Image Prior and Exploiting Self-Guidance for Image Reconstruction
Source quote
L626: 4x │ 28.2
2024DiffPIR baselinePSNR28.31subset=knee · resolution=320x320 · acceleration=4x · diffusion-model=EDMImproving Diffusion Inverse Problem Solving with Decoupled Noise Annealing
Source quote
L201: DiffPIR │ 28.31 │ 0.632 │ 10.55 │ 26.78 │ 0.588 │ 7.79
2024DiffPIR baselinePSNR26.78subset=knee · resolution=320x320 · acceleration=8x · diffusion-model=EDMImproving Diffusion Inverse Problem Solving with Decoupled Noise Annealing
Source quote
L201: DiffPIR │ 28.31 │ 0.632 │ 10.55 │ 26.78 │ 0.588 │ 7.79
2024Conditional DPS baselinePSNR39.67noise=noise-free · anatomy=brain · acceleration=4×ADOBI: Adaptive Diffusion Bridge For Blind Inverse Problems with Application to MRI Reconstruction
Source quote
L387: Acce. │ Method │ PSNR │ SSIM │ LPIPS 4× │ Conditional DPS │ 39.67 │ 0.984 │ 0.039
2024NCPDNET baselinePSNR37.765acceleration-factor=4 · training-acceleration-factor=4Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI Reconstruction
Source quote
L201: NCPDNET │ 37.765 │ 29.912 │ 0.977 │ 0.916
2024NCPDNET baselinePSNR29.912acceleration-factor=16 · training-acceleration-factor=4Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI Reconstruction
Source quote
L201: NCPDNET │ 37.765 │ 29.912 │ 0.977 │ 0.916
2024NCPDNET baselineSSIM0.916acceleration-factor=16 · training-acceleration-factor=4Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI Reconstruction
Source quote
L201: NCPDNET │ 37.765 │ 29.912 │ 0.977 │ 0.916
2024SARR baselinePSNR35.98split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=8-fold · coil-setting=multi-coil · patch-resolution=320×320Iteratively Refined Image Reconstruction with Learned Attentive Regularizers
Source quote
L787: SARR \cite{NeuPouGou2023} │ 36.25 │ 34.77 │ 0.904 │ 0.839 │ 35.98 │ 35.26 │ 0.901 │ 0.858
2023RED-diff proposedPSNR37.1 dBsplit: val · coil=multi-coil · subset=6 validation volumes · undersampling=1D equispaced, R=4A Variational Perspective on Solving Inverse Problems with Diffusion Models
Source quote
L482: RED-diff │ 37.1 │ 33.2 │ 32.7 │ 0.114
2023RGFL proposed non-standard sliceStd. Dev.9.73E-7split: val · speedup=4×On the Quantification of Image Reconstruction Uncertainty without Training Data
Source quote
L210: Std. Dev. \downarrow │ 8.87E-5 │ 1.21E-5 │ 8.82E-6 │ 6.90E-6 │ {\bf 9.73E-7}
2023RGFL proposed non-standard sliceAbs. Error1.78E-6speedup=4×On the Quantification of Image Reconstruction Uncertainty without Training Data
Source quote
L211: Abs. Error \downarrow │ 8.72E-5 │ 3.31E-5 │ 6.91E-6 │ 1.83E-6 │ {\bf 1.78E-6}
2023McASSR (Ours; rectangle window 4×16/16×4) proposedPSNR32.52 dBsplit: test · scale=4x in-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PDRethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L483: 32.52
2023McASSR (Ours; rectangle window 4×16/16×4) proposedPSNR28.76 dBsplit: test · scale=8x out-of-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PDRethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L487: 28.76
2023U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard sliceSSIM0.902split: test · subset=PDFS knee · test-acceleration=4-fold · training-acceleration=2-, 4-, 8-, and 16-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912
2023U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard sliceSSIM0.912split: test · subset=PDFS knee · test-acceleration=3-fold · training-acceleration=2-, 4-, 8-, and 16-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912
2023CDiffMR-LogSR proposedInference Time ↓3.030anatomy=knee · hardware=NVIDIA RTX 3090 · acceleration-factor=8×CDiffMR: Can We Replace the Gaussian Noise with K-Space Undersampling for Fast MRI?
Source quote
L207: CDiffMR-LogSR │ 0.744 (0.107) │ 27.26 (2.52) │ 0.236 (0.041) │ 3.030
2023JSMoCo (R=2) proposed non-standard sliceNRMSE0.0093motion=rotation ±2°, translation ±3 pixels · sequence=T2-weighted brain · acceleration=R=2JSMoCo: Joint Coil Sensitivity and Motion Correction in Parallel MRI with a Self-Calibrating Score-Based Diffusion Model
Source quote
L384: Ours ( R = 2) │ 0.0093 │ 0.0093 │ 0.0091 │ 0.0099
2023JSMoCo (R=4.8) proposed non-standard sliceNRMSE0.0101motion=rotation ±2°, translation ±3 pixels · sequence=T2-weighted brain · acceleration=R=4.8JSMoCo: Joint Coil Sensitivity and Motion Correction in Parallel MRI with a Self-Calibrating Score-Based Diffusion Model
Source quote
L386: Ours (R = 4.8) │ 0.0101 │ 0.0111 │ 0.0110 │ 0.0107
2023APMC-PnP proposedPSNR32.70 dBsplit: test · acceleration=8×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1750: APMC-PnP (ours) │ 32.70 │ 36.03
2023APMC-PnP proposedPSNR36.03 dBsplit: test · acceleration=4×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1750: APMC-PnP (ours) │ 32.70 │ 36.03
2023Fed-PMG proposed#Info.cost46.88 Msetting=with clustering · measurement=one communication round · field-strength=1.5TFederated Pseudo Modality Generation for Incomplete Multi-Modal MRI Reconstruction
Source quote
L385: Fed-PMG │ 7.40 │ 46.88 │ \Omega(\varphi + K \beta)
2023Proposed joint non-linear inversion algorithm with diffusion prior proposedPSNR34.34split: val · subset=8% ACL; 15 central slices · contrast=PD · sampling=4-fold Cartesian; swapped phase-encoding direction · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L304: Cartesian\tnote{*} │ 4 │ 30.37 │ 28.65 │ 32.43 │ 30.88 │ 23.89 │ 29.68 │ 34.34 │ 32.88
2023Proposed joint non-linear inversion algorithm with diffusion prior proposedPSNR31.55split: val · subset=15 central slices · contrast=PDFS · sampling=4-fold Gaussian · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L305: Gaussian │ 4 │ 30.24 │ 27.68 │ 30.91 │ 30.90 │ 22.36 │ 27.35 │ 31.01 │ 31.55
2023Proposed joint non-linear inversion algorithm with diffusion prior proposedPSNR31.78split: val · subset=15 central slices · contrast=PDFS · sampling=radial; 45 spokes; 11-fold acceleration · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L306: Radial │ 11 │ 27.93 │ 26.70 │ 30.66 │ 30.70 │ 19.97 │ 25.55 │ 32.18 │ 31.78
2023Fed-CRFD proposedPSNR35.35 dBMain comparison; PSNR averaged over three independent trials. The passage mentions β=10…Cross-Modal Vertical Federated Learning for MRI Reconstruction
Source quote
L289: We report the MRI reconstruction performances on two datasets in Table \ref{tab1} under different settings (i.e., \beta = 10% and \beta = 2%). For FL-MRCM and FedMRI, we adopt the settings of the original papers. To alleviate the influence caused by random initialization, the average PSNR, SSIM scores and standard derivation of three independent trials are calculated for the comparing methods and our Fed-CRFD. Additionally, to measure the statistical significance of performance improvements, we conduct the paired t-test for Fed-CRFD and each baseline, and report the p-value as well. As seen, the FL methods significantly outperform Solo, which demonstrates the effectiveness of FL in leveraging multiple clients to obtain a robust global model. Compared to FedAvg, the FL-MRCM achieves almost the same PSNR and even lower SSIM scores. Such an experimental result shows that FL-MRCN cannot tackle the domain shift problem from different modalities. Due to learning the specific information of clients, FedMRI can mitigate the modal difference to some extent compared with FedAvg. Besides, the previous horizontal FL frameworks, i.e., FL-MRCM and FedMRI, have not considered the valuable information of vertical samples. In contrast, thanks to the novel design of our method, our method can effectively address the problem, which significantly improves the PSNR scores from 33.30 dB to 35.35 dB on the fastMRI dataset and from 29.86 dB to 30.95 dB on our private dataset, respectively. Furthermore, our Fed-CRFD is verified to achieve the significant improvement compared to FL-MRCM and FedMRI, i.e., the corresponding p-value < 0.05, and the comparable performance to the centralized model on our private dataset, which show the superiority of our method.
2023Fed-PMG† (clustering removed) ablation#Info.cost2227.34 Msetting=clustering removed · measurement=one communication round · field-strength=1.5TFederated Pseudo Modality Generation for Incomplete Multi-Modal MRI Reconstruction
Source quote
L384: Fed-PMG^\dagger │ 7.40 │ 2227.34 │ \Omega(\varphi + n \beta)
2023CSGM baselinePSNR36.3 dBsplit: val · coil=multi-coil · subset=6 validation volumes · undersampling=1D equispaced, R=4A Variational Perspective on Solving Inverse Problems with Diffusion Models
Source quote
L481: CSGM │ 36.3 │ 31.4 │ 31.8 │ 0.344
2023DPI baseline non-standard sliceStd. Dev.1.21E-5split: val · speedup=4×On the Quantification of Image Reconstruction Uncertainty without Training Data
Source quote
L210: Std. Dev. \downarrow │ 8.87E-5 │ 1.21E-5 │ 8.82E-6 │ 6.90E-6 │ {\bf 9.73E-7}
2023DPI baseline non-standard sliceAbs. Error3.31E-5speedup=4×On the Quantification of Image Reconstruction Uncertainty without Training Data
Source quote
L211: Abs. Error \downarrow │ 8.72E-5 │ 3.31E-5 │ 6.91E-6 │ 1.83E-6 │ {\bf 1.78E-6}
2023McMRSR [14] baselinePSNR31.96 dBscale=4x in-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PDRethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L428: 31.96
2023LTE* [13] (SwinIR backbone; reference and target concatenated) baselinePSNR27.85 dBscale=8x out-of-scale · anatomy=knee · backbone=SwinIR · target-modality=FS-PD · reference-modality=PDRethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L476: 27.85
2023U-net trained on 4-fold acceleration data baseline non-standard sliceSSIM0.903split: test · subset=PDFS knee · test-acceleration=4-fold · training-acceleration=4-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L321: 4-fold │ --- │ 0.903 │ --- │ --- │ 0.899
2023U-net trained on 2-fold acceleration data baseline non-standard sliceSSIM0.906split: test · subset=PDFS knee · test-acceleration=3-fold · training-acceleration=2-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L320: 2-fold │ 0.945 │ --- │ --- │ --- │ 0.906
2023DiffuseRecon baselineInference Time ↓183.770anatomy=knee · hardware=NVIDIA RTX 3090 · acceleration-factor=8×CDiffMR: Can We Replace the Gaussian Noise with K-Space Undersampling for Fast MRI?
Source quote
L205: DiffuseRecon~\cite{Peng_2022_Towards} │ 0.738 (0.108) (\star) │ 27.40 (2.40) │ 0.286 (0.038) (\star) (\dagger) │ 183.770
2023Motion-corrupted CSM estimated with ESPIRiT baseline non-standard sliceNRMSE0.0228method=ESPIRiT · motion=rotation ±2°, translation ±3 pixels · sequence=T2-weighted brainJSMoCo: Joint Coil Sensitivity and Motion Correction in Parallel MRI with a Self-Calibrating Score-Based Diffusion Model
Source quote
L388: Corrputed │ 0.0228 │ 0.0274 │ 0.0233 │ 0.0270
2023VarNet-8× baselinePSNR32.82 dBsplit: test · fine-tuned · model=VarNet · acceleration=8×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1746: VarNet-8× │ 32.82 │ 35.01
2023VarNet-4× baselinePSNR36.00 dBsplit: test · fine-tuned · model=VarNet · acceleration=4×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1745: VarNet-4× │ 28.51 │ 36.00
2023DDPM (Xie et al.) baselinePSNR36.69contrast=proton-density · acceleration-factor=4A survey of emerging applications of diffusion probabilistic models in MRI
Source quote
L619: \cite{xie2022measurement} │ DDPM │ 36.69 │ 0.905
2023CNN (Ronneberger et al.) baselinePSNR34.04contrast=proton-density · acceleration-factor=4A survey of emerging applications of diffusion probabilistic models in MRI
Source quote
L618: \cite{ronneberger2015u} │ CNN │ 34.04\tnote{a} │ 0.834\tnote{a}
2023DDPM (Xie et al.) baselineSSIM0.905contrast=proton-density · acceleration-factor=4A survey of emerging applications of diffusion probabilistic models in MRI
Source quote
L619: \cite{xie2022measurement} │ DDPM │ 36.69 │ 0.905
2023CNN (Ronneberger et al.) baselineSSIM0.834contrast=proton-density · acceleration-factor=4A survey of emerging applications of diffusion probabilistic models in MRI
Source quote
L618: \cite{ronneberger2015u} │ CNN │ 34.04\tnote{a} │ 0.834\tnote{a}
2023TV baseline (Charbonnier-smoothed TV regularizer) baselinePSNR32.43split: val · subset=8% ACL; 15 central slices · contrast=PD · sampling=4-fold Cartesian; swapped phase-encoding direction · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L304: Cartesian\tnote{*} │ 4 │ 30.37 │ 28.65 │ 32.43 │ 30.88 │ 23.89 │ 29.68 │ 34.34 │ 32.88
2023TV baseline (Charbonnier-smoothed TV regularizer) baselinePSNR30.90split: val · subset=15 central slices · contrast=PDFS · sampling=4-fold Gaussian · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L305: Gaussian │ 4 │ 30.24 │ 27.68 │ 30.91 │ 30.90 │ 22.36 │ 27.35 │ 31.01 │ 31.55