fastMRI

86 papers · 287 extracted observations · mri reconstruction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

22.829.335.842.3202120242026A-DPS (proposed): 30.2 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 35.8 (2021)Joint-ICNet: 37.3 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 39.4 (2021)Joint-ICNet: 40.7 (2021)Deep Equilibrium (Grad): 32.01 (2021)CRR-NN: 40.95 (2023)LLS (\lambda=10 (-6)): 31.54 (2024)aSeqDIP: 34.08 (2024)Deform-Mamba (Our): 32.11 (2024)SAFI: 36.06 (2024)SAFI: 36.43 (2024)Interleaved (self-supervised loss added during training): 31.55 (2025)DEAL: 36.21 (2025)DEAL: 36.59 (2025)MFoE: 35.4 (2025)Distilled (on-policy privileged information distillation): 24.11 (2026)Distilled (on-policy privileged information distillation): 26.0 (2026)Distilled (on-policy privileged information distillation): 27.86 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 48 of 48 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024Nila (Nila-DC) proposedPSNR37.08split: val · noise=none · acceleration=6×Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRI
Source quote
L124: Nila (ours) │ \textcolor{red}{37.08} │ \textcolor{red}{95.74} │ \textcolor{red}{34.82} │ \textcolor{red}{94.21} │ \textcolor{red}{36.10} │ \textcolor{red}{94.34} │ \textcolor{red}{33.54} │ \textcolor{red}{91.55} │ \textcolor{red}{30.23} │ \textcolor{red}{91.59} │ \textcolor{red}{29.86} │ \textcolor{red}{90.06}
2024Nila (Nila-DC) proposedPSNR31.86split: val · noise=Gaussian σ=0.1 · acceleration=6×Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRI
Source quote
L145: Nila (ours) │ \textcolor{red}{34.98} │ \textcolor{red}{93.96} │ \textcolor{red}{33.56} │ \textcolor{red}{92.49} │ \textcolor{red}{31.86} │ \textcolor{red}{90.38} │ \textcolor{red}{34.11} │ \textcolor{red}{91.53} │ \textcolor{red}{32.80} │ \textcolor{red}{89.59} │ \textcolor{red}{31.25} │ \textcolor{red}{87.15}
2024CSGM baselinePSNR35.04split: val · noise=none · acceleration=6×Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRI
Source quote
L121: CSGM │ \textcolor{blue}{35.04} │ \textcolor{blue}{93.53} │ \textcolor{blue}{32.11} │ \textcolor{blue}{90.78} │ \textcolor{blue}{34.67} │ \textcolor{blue}{92.65} │ \textcolor{blue}{31.57} │ \textcolor{blue}{88.94} │ 26.73 │ 84.53 │ 25.63 │ 82.78
2024Spreco baselinePSNR25.89split: val · noise=Gaussian σ=0.1 · acceleration=6×Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRI
Source quote
L143: Spreco │ \textcolor{blue}{31.31} │ \textcolor{blue}{89.03} │ \textcolor{blue}{29.62} │ \textcolor{blue}{84.93} │ \textcolor{blue}{25.89} │ \textcolor{blue}{74.23} │ 31.32 │ \textcolor{blue}{88.03} │ \textcolor{blue}{29.58} │ \textcolor{blue}{83.88} │ \textcolor{blue}{26.41} │ 74.10
2023RED-diff proposedPSNR37.1 dBsplit: val · coil=multi-coil · subset=6 validation volumes · undersampling=1D equispaced, R=4A Variational Perspective on Solving Inverse Problems with Diffusion Models
Source quote
L482: RED-diff │ 37.1 │ 33.2 │ 32.7 │ 0.114
2023RGFL proposed non-standard sliceStd. Dev.9.73E-7split: val · speedup=4×On the Quantification of Image Reconstruction Uncertainty without Training Data
Source quote
L210: Std. Dev. \downarrow │ 8.87E-5 │ 1.21E-5 │ 8.82E-6 │ 6.90E-6 │ {\bf 9.73E-7}
2023Proposed joint non-linear inversion algorithm with diffusion prior proposedPSNR34.34split: val · subset=8% ACL; 15 central slices · contrast=PD · sampling=4-fold Cartesian; swapped phase-encoding direction · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L304: Cartesian\tnote{*} │ 4 │ 30.37 │ 28.65 │ 32.43 │ 30.88 │ 23.89 │ 29.68 │ 34.34 │ 32.88
2023Proposed joint non-linear inversion algorithm with diffusion prior proposedPSNR31.55split: val · subset=15 central slices · contrast=PDFS · sampling=4-fold Gaussian · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L305: Gaussian │ 4 │ 30.24 │ 27.68 │ 30.91 │ 30.90 │ 22.36 │ 27.35 │ 31.01 │ 31.55
2023Proposed joint non-linear inversion algorithm with diffusion prior proposedPSNR31.78split: val · subset=15 central slices · contrast=PDFS · sampling=radial; 45 spokes; 11-fold acceleration · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L306: Radial │ 11 │ 27.93 │ 26.70 │ 30.66 │ 30.70 │ 19.97 │ 25.55 │ 32.18 │ 31.78
2023CSGM baselinePSNR36.3 dBsplit: val · coil=multi-coil · subset=6 validation volumes · undersampling=1D equispaced, R=4A Variational Perspective on Solving Inverse Problems with Diffusion Models
Source quote
L481: CSGM │ 36.3 │ 31.4 │ 31.8 │ 0.344
2023DPI baseline non-standard sliceStd. Dev.1.21E-5split: val · speedup=4×On the Quantification of Image Reconstruction Uncertainty without Training Data
Source quote
L210: Std. Dev. \downarrow │ 8.87E-5 │ 1.21E-5 │ 8.82E-6 │ 6.90E-6 │ {\bf 9.73E-7}
2023TV baseline (Charbonnier-smoothed TV regularizer) baselinePSNR32.43split: val · subset=8% ACL; 15 central slices · contrast=PD · sampling=4-fold Cartesian; swapped phase-encoding direction · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L304: Cartesian\tnote{*} │ 4 │ 30.37 │ 28.65 │ 32.43 │ 30.88 │ 23.89 │ 29.68 │ 34.34 │ 32.88
2023TV baseline (Charbonnier-smoothed TV regularizer) baselinePSNR30.90split: val · subset=15 central slices · contrast=PDFS · sampling=4-fold Gaussian · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L305: Gaussian │ 4 │ 30.24 │ 27.68 │ 30.91 │ 30.90 │ 22.36 │ 27.35 │ 31.01 │ 31.55
2023TV baseline (Charbonnier-smoothed TV regularizer) baselinePSNR30.70split: val · subset=15 central slices · contrast=PDFS · sampling=radial; 45 spokes; 11-fold acceleration · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L306: Radial │ 11 │ 27.93 │ 26.70 │ 30.66 │ 30.70 │ 19.97 │ 25.55 │ 32.18 │ 31.78
2022Variable-acceleration VarNet (authors’ “Our VarNet”) proposedNMSE (×10³)1.55split: val · coil=multi-coil · anatomy=brain · acceleration=variableA Path Towards Clinical Adaptation of Accelerated MRI
Source quote
L290: Our VarNet │ 96.7± 0.02 │ 1.55 │ 43.3± 0.03
2021PDNet w DC proposedPSNR32.66split: val · coil=single-coil · coverage=both contrasts · trajectory=radial · acceleration=4Density Compensated Unrolled Networks for Non-Cartesian MRI Reconstruction
Source quote
L174: PDNet w DC │ 32.66 / 0.7327 │ 33.08 / 0.7534 │ 156k
2021PDNet w DC proposedSSIM0.7327split: val · coil=single-coil · coverage=both contrasts · trajectory=radial · acceleration=4Density Compensated Unrolled Networks for Non-Cartesian MRI Reconstruction
Source quote
L174: PDNet w DC │ 32.66 / 0.7327 │ 33.08 / 0.7534 │ 156k
2021U-net on Adjoint + DC baselinePSNR32.26split: val · coil=single-coil · model=U-net · coverage=both contrasts · trajectory=radial · acceleration=4Density Compensated Unrolled Networks for Non-Cartesian MRI Reconstruction
Source quote
L173: U-net on Adjoint + DC │ 32.26 / 0.7224 │ 32.82 / 0.7460 │ 481k
2020ReconODE-LT-Euler proposedPSNR31.86split: val · subset=single-coil knee · undersampling=4xMRI Image Reconstruction via Learning Optimization Using Neural ODEs
Source quote
L141: ReconODE-LT-Euler │ 0.03M │ 31.86 │ 29.11 │ 0.7194 │ 0.6363
2020ReconODE-LT-Euler proposedSSIM0.7194split: val · subset=single-coil knee · undersampling=4xMRI Image Reconstruction via Learning Optimization Using Neural ODEs
Source quote
L141: ReconODE-LT-Euler │ 0.03M │ 31.86 │ 29.11 │ 0.7194 │ 0.6363
2020Proposed pixel-wise RL MRI reconstruction (Ours, with data consistency) proposed non-standard sliceNMSE0.14split: val · coil=single-coil · subset=first 1,000 validation images · masking=random 40%MRI Reconstruction with Interpretable Pixel-Wise Operations Using Reinforcement Learning
Source quote
L338: 0.14
2020Proposed pixel-wise RL MRI reconstruction (Ours, with data consistency) proposed non-standard slicePSNR30.3split: val · coil=single-coil · subset=first 1,000 validation images · masking=random 40%MRI Reconstruction with Interpretable Pixel-Wise Operations Using Reinforcement Learning
Source quote
L339: 30.3
2020Proposed pixel-wise RL MRI reconstruction (Ours, with data consistency) proposed non-standard sliceSSIM0.88split: val · coil=single-coil · subset=first 1,000 validation images · masking=random 40%MRI Reconstruction with Interpretable Pixel-Wise Operations Using Reinforcement Learning
Source quote
L340: 0.88 the images are of various sizes, we crop the 320x320 center region and then do the down-sampling. In addition, images are normalized and rescaled into range [0, 255].
2020Orientation adversary (Adversary) proposedAverage rank for visible banding (higher is better)2.83split: val · acceleration=4× · field-strength=1.5T · central-k-space-lines=16MRI Banding Removal via Adversarial Training
Source quote
L412: Adversary │ 1.09×10 (-11) │ 2.18×10 (-11) │ 2.83\tabularnewline
2020Orientation adversary (Adversary) proposed non-standard sliceAverage rank for retention of fine anatomical detail versus ground truth (higher is better)2.18split: val · acceleration=4× · field-strength=1.5T · central-k-space-lines=16MRI Banding Removal via Adversarial Training
Source quote
L432: Adversary │ 2.61 │ 8.82×10 (-4) │ 2.18\tabularnewline
2020Orientation adversary (Adversary) proposedReports of any banding present (yes/no)0.725 proportionsplit: val · acceleration=4× · field-strength=1.5T · central-k-space-lines=16MRI Banding Removal via Adversarial Training
Source quote
L454: 0.725 (0.62-0.82) │ 0.967 (0.92-1) │ 0.975 (0.90-0.99)\tabularnewline
2020Standard (non-adversarial) ablation non-standard sliceAverage rank for visible banding (higher is better)1.43split: val · acceleration=4× · field-strength=1.5T · central-k-space-lines=16MRI Banding Removal via Adversarial Training
Source quote
L416: Standard │ 1.43\tabularnewline
2020Standard (non-adversarial) ablation non-standard sliceAverage rank for retention of fine anatomical detail versus ground truth (higher is better)2.32split: val · acceleration=4× · field-strength=1.5T · central-k-space-lines=16MRI Banding Removal via Adversarial Training
Source quote
L436: Standard │ 2.32\tabularnewline
2020Standard (non-adversarial) ablation non-standard sliceReports of any banding present (yes/no)0.967 proportionsplit: val · acceleration=4× · field-strength=1.5T · central-k-space-lines=16MRI Banding Removal via Adversarial Training
Source quote
L454: 0.725 (0.62-0.82) │ 0.967 (0.92-1) │ 0.975 (0.90-0.99)\tabularnewline
2020UNet baselinePSNR31.84split: val · subset=single-coil knee · undersampling=4xMRI Image Reconstruction via Learning Optimization Using Neural ODEs
Source quote
L132: UNet │ 3.35M │ 31.84 │ 29.87 │ 0.7177 │ 0.6514
2020UNet baselineSSIM0.7177split: val · subset=single-coil knee · undersampling=4xMRI Image Reconstruction via Learning Optimization Using Neural ODEs
Source quote
L132: UNet │ 3.35M │ 31.84 │ 29.87 │ 0.7177 │ 0.6514
2019Proposed self-supervised learning (SSL; U-net inverse operator) proposedPSNR22.86 dBsplit: val · acceleration=×8Self-supervised learning of inverse problem solvers in medical imaging
Source quote
L130: PSNR │ 13.74 │ N/A │ 22.86 │ 26.72
2019Proposed self-supervised learning (SSL; U-net inverse operator) proposedSSIM0.47split: val · acceleration=×8Self-supervised learning of inverse problem solvers in medical imaging
Source quote
L131: SSIM │ 0.40 │ N/A │ 0.47 │ 0.604
2019Offset 0 sampling proposedSSIM0.924split: val · sampling=Offset 0 · coil-setup=multi-coil · acceleration=4x · low-frequency-lines=16Offset Masking Improves Deep Learning based Accelerated MRI Reconstructions
Source quote
L261: knee MRI reconstruction, showing an improvement in SSIM from 0.924
2019Offset 1 sampling proposedSSIM0.926split: val · sampling=Offset 1 · coil-setup=multi-coil · acceleration=4x · low-frequency-lines=16Offset Masking Improves Deep Learning based Accelerated MRI Reconstructions
Source quote
L262: to 0.926.}
2019PC-RNN (multi-coil) proposedPSNR39.0split: val · coil=multi-coil · acceleration=4xPyramid Convolutional RNN for MRI Reconstruction
Source quote
L134: Multi-coil │ PC-RNN │ 39.0 │ 36.5 │ 0.914 │ 0.884
2019PC-RNN (multi-coil) proposedPSNR36.5split: val · coil=multi-coil · acceleration=8xPyramid Convolutional RNN for MRI Reconstruction
Source quote
L134: Multi-coil │ PC-RNN │ 39.0 │ 36.5 │ 0.914 │ 0.884
2019PC-RNN (single-coil) proposedPSNR31.3split: val · coil=single-coil · acceleration=8xPyramid Convolutional RNN for MRI Reconstruction
Source quote
L131: Single-coil │ PC-RNN │ 32.8 │ 31.3 │ 0.743 │ 0.682
2019Supervised restoration model baselinePSNR26.72 dBsplit: val · acceleration=×8Self-supervised learning of inverse problem solvers in medical imaging
Source quote
L130: PSNR │ 13.74 │ N/A │ 22.86 │ 26.72
2019Supervised restoration model baselineSSIM0.604split: val · acceleration=×8Self-supervised learning of inverse problem solvers in medical imaging
Source quote
L131: SSIM │ 0.40 │ N/A │ 0.47 │ 0.604
2019deep decoder k=128 baselineMRI reconstruction performance34.51 dBsplit: val · subset=100 images · architecture=i · coil-setting=single-coil · method-variant=deep decoder k=128Regularizing linear inverse problems with convolutional neural networks
Source quote
L417: deep decoder k=128 │ 34.51 dB
2019deep decoder k=256 baselineMRI reconstruction performance34.74 dBsplit: val · subset=100 images · architecture=i · coil-setting=single-coil · method-variant=deep decoder k=256; slightly overparameterizedRegularizing linear inverse problems with convolutional neural networks
Source quote
L418: deep decoder k=256 │ 34.74 dB
2019deep decoder k=512 baselineMRI reconstruction performance34.60 dBsplit: val · subset=100 images · architecture=i · coil-setting=single-coil · method-variant=deep decoder k=512Regularizing linear inverse problems with convolutional neural networks
Source quote
L419: deep decoder k=512 │ 34.60 dB
2019\ell_1-minimization baselineMRI reconstruction performance33.20 dBsplit: val · method=l1-minimization · subset=100 images · coil-setting=single-coilRegularizing linear inverse problems with convolutional neural networks
Source quote
L420: \ell_1-minimization │ 33.20 dB
2019total variation baselineMRI reconstruction performance33.37 dBsplit: val · method=total variation · subset=100 images · coil-setting=single-coilRegularizing linear inverse problems with convolutional neural networks
Source quote
L421: total variation │ 33.37 dB
2019U-Net (multi-coil) baselinePSNR36.7split: val · coil=multi-coil · acceleration=4xPyramid Convolutional RNN for MRI Reconstruction
Source quote
L133: Multi-coil │ U-Net │ 36.7 │ 33.7 │ 0.894 │ 0.852
2019U-Net (multi-coil) baselinePSNR33.7split: val · coil=multi-coil · acceleration=8xPyramid Convolutional RNN for MRI Reconstruction
Source quote
L133: Multi-coil │ U-Net │ 36.7 │ 33.7 │ 0.894 │ 0.852
2019U-Net (single-coil) baselinePSNR29.9split: val · coil=single-coil · acceleration=8xPyramid Convolutional RNN for MRI Reconstruction
Source quote
L130: Single-coil │ U-Net │ 31.9 │ 29.9 │ 0.723 │ 0.654