fastMRI
86 papers · 287 extracted observations · mri reconstruction · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CRR-NN SOTA frontier | 40.95 | 2023-01-01 | coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-fold · FastMRI knee PD test images; 2-fold Cartesian undersampling, measurement noise standa… | A Neural-Network-Based Convex Regularizer for Inverse ProblemsSource quoteCRR-NN │ {\bf 40.95} │ 38.91 │ {\bf 0.961} │ 0.934 │ 33.99 │ 33.75 │ 0.880 │ 0.831 |
| 2 | Joint-ICNet SOTA frontier (+3 variants) | 40.7 | 2021-01-01 | reduction-factor=4 · Table 2 model ablation; reduction factor R=4. Paper setup uses multi-coil k-space ret… | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quote40.7 |
| 3 | DEAL (+1 variant) | 36.59 | 2025-01-01 | coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-fold · 4-fold single-coil setup; centered 320×320 patches from 50 test images; additive whit… | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteDEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32 |
| 4 | SAFI (+1 variant) | 36.43 | 2024-07-01 | subset=50 test images · sequence=PD · resolution=320x320 · acceleration=4-fold · coil-setting=single-coil · patch-resolution=320×320 · PD knee images without fat suppression; denoising-trained model, with λ tuned on 10 v… | Iteratively Refined Image Reconstruction with Learned Attentive RegularizersSource quoteSAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860 |
| 5 | MFoE | 35.4 | 2025-08-01 | noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4 · PD data; acceleration factor 4 and center fraction 0.08; Gaussian measurement noise w… | Multivariate Fields of ExpertsSource quoteMFoE │ 35.40 │ 34.21 │ 30.26 │ 31.20 |
| 6 | aSeqDIP | 34.08 | 2024-01-01 | undersampling=4× · averaged-scans=20 · Average over 20 MRI scans from the fastMRI testing set at 4× undersampling; no labele… | Image Reconstruction Via Autoencoding Sequential Deep Image PriorSource quote34.08 |
| 7 | Deform-Mamba (Our) | 32.11 | 2024-07-01 | scale=4× · 4× upsampling; held-out test split (45 subjects); low-resolution inputs synthesized i… | Deform-Mamba Network for MRI Super-ResolutionSource quoteOur │ 32.11 │ 0.7194 │ 30.60 │ 0.8965 |
| 8 | Deep Equilibrium (Grad) | 32.01 | 2021-02-01 | roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8× · Test-set mean; 8× accelerated virtual single-coil Cartesian MRI with complex AWGN sta… | Deep Equilibrium Architectures for Inverse Problems in ImagingSource quotePSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38 |
| 9 | Interleaved (self-supervised loss added during training) | 31.55 | 2025-01-01 | method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brain · 6x-accelerated MRI; trained on the FastMRI brain dataset and tested on knees. | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteInterleaved │ 31.55 │ .7910 |
| 10 | LLS (\lambda=10 (-6)) | 31.54 | 2024-01-01 | mask=acceleration=4, center_fraction=0.08 · coils=single-coil · lambda=1e-6 · noise_sigma=0.01 · test_images=99 · PnP-FBS reconstruction; measurement noise \sigma-\mathbf n=0.01; mask (M_{\text{acc}}… | Improving Lipschitz-Constrained Neural Networks by Learning Activation FunctionsSource quoteLLS │ 31.54 │ 0.7924 │ 28.04 │ 0.7108 |
| 11 | A-DPS (proposed) | 30.2 | 2021-01-01 | resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 · Table 2: acceleration factor 8; scenario-30L (30 k-space lines closest to DC, with 16… | Active Deep Probabilistic SubsamplingSource quote30.2 |
| 12 | Distilled (on-policy privileged information distillation) (+2 variants) | 27.86 | 2026-05-01 | contrast=T1 · acceleration=R=32 · undersampling=Gaussian-VD · R=32; Gaussian-VD undersampling; T1 contrast. | Next-Acceleration-Scale Prediction for Autoregressive MRI ReconstructionSource quoteDistilled │ 27.86 │ 22.29 │ 24.08 │ 0.81 │ 0.70 │ 0.67 │ 0.148 │ 0.161 │ 0.162 |
Showing 125 of 125 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Distilled (on-policy privileged information distillation) proposed | PSNR | 27.86 | split: test · contrast=T1 · acceleration=R=32 · undersampling=Gaussian-VD | Next-Acceleration-Scale Prediction for Autoregressive MRI ReconstructionSource quoteL344: Distilled │ 27.86 │ 22.29 │ 24.08 │ 0.81 │ 0.70 │ 0.67 │ 0.148 │ 0.161 │ 0.162 |
| 2026 | Distilled (on-policy privileged information distillation) proposed | PSNR | 24.11 | split: test · contrast=T1 · acceleration=R=32 · undersampling=ES Cartesian-Y | Next-Acceleration-Scale Prediction for Autoregressive MRI ReconstructionSource quoteL354: Distilled │ 24.11 │ 18.42 │ 20.96 │ 0.74 │ 0.55 │ 0.57 │ 0.169 │ 0.230 │ 0.216 |
| 2026 | Distilled (on-policy privileged information distillation) proposed | PSNR | 26.00 | split: test · contrast=T1 · acceleration=R=32 · undersampling=Radial | Next-Acceleration-Scale Prediction for Autoregressive MRI ReconstructionSource quoteL359: Distilled │ 26.00 │ 20.51 │ 22.68 │ 0.78 │ 0.64 │ 0.63 │ 0.160 │ 0.196 │ 0.186 |
| 2026 | EvoML proposed | SSIM | 0.9498 | split: test · supervised | Validation-Gated ML Pipeline Synthesis with Expert-Grounded Self-Evolving SkillsSource quoteL975: The margin is largest on the harder tasks, reaching 0.9498 |
| 2025 | Interleaved (self-supervised loss added during training) proposed | PSNR | 31.55 | split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brain | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteL283: Interleaved │ 31.55 │ .7910 |
| 2025 | Interleaved (self-supervised loss added during training) proposed | SSIM | .7910 | split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brain | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteL283: Interleaved │ 31.55 │ .7910 |
| 2025 | DEAL proposed | PSNR | 36.59 | split: test · coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-fold | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteL355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32 |
| 2025 | DEAL proposed | PSNR | 36.21 | split: test · coils=multi-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=8-fold | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteL355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32 |
| 2025 | SelfDB proposed | NRMSE | 0.108 | split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25% | A Self-Supervised Diffusion Bridge for MRI ReconstructionSource quoteL137: SelfDB │ 0.108 │ 0.882 │ 0.036 |
| 2025 | SelfDB proposed | SSIM | 0.882 | split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25% | A Self-Supervised Diffusion Bridge for MRI ReconstructionSource quoteL137: SelfDB │ 0.108 │ 0.882 │ 0.036 |
| 2025 | SelfDB proposed | LPIPS | 0.036 | split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25% | A Self-Supervised Diffusion Bridge for MRI ReconstructionSource quoteL137: SelfDB │ 0.108 │ 0.882 │ 0.036 |
| 2025 | C-MSM proposed non-standard slice | PSNR | 32.7 | split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01 | Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity EstimationSource quoteL179: C\text{-}MSM │ \hlblue{32.7} │ 0.853 │ \hlgreen{0.144} [2pt] \cdashline{1-5} [2pt] |
| 2025 | C-MSM proposed non-standard slice | PSNR | 28.8 | split: test · acs-lines=20 · acceleration=×8 · measurement-noise=σ=0.01 | Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity EstimationSource quoteL187: C\text{-}MSM │ \hlgreen{28.8} │ \hlblue{0.760} │ 0.265 |
| 2025 | C-MSM proposed non-standard slice | LPIPS | 0.144 | split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01 | Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity EstimationSource quoteL179: C\text{-}MSM │ \hlblue{32.7} │ 0.853 │ \hlgreen{0.144} [2pt] \cdashline{1-5} [2pt] |
| 2025 | MFoE proposed | PSNR | 35.40 | split: test · noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4 | Multivariate Fields of ExpertsSource quoteL327: MFoE │ 35.40 │ 34.21 │ 30.26 │ 31.20 |
| 2025 | Supervised learning baseline non-standard slice | PSNR | 32.68 | split: test · anatomy=knee · training=supervised with oracle ground truth · acceleration=6x | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteL414: (Supervised) │ (32.68) │ (.8141) |
| 2025 | Supervised learning baseline non-standard slice | SSIM | .8141 | split: test · anatomy=knee · training=supervised with oracle ground truth · acceleration=6x | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteL414: (Supervised) │ (32.68) │ (.8141) |
| 2025 | SAFI baseline | PSNR | 36.43 | split: test · coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-fold | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteL354: SAFI │ 36.43 │ 34.92 │ 36.06 │ 35.36 |
| 2025 | SAFI baseline | PSNR | 36.06 | split: test · coils=multi-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=8-fold | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteL354: SAFI │ 36.43 │ 34.92 │ 36.06 │ 35.36 |
| 2025 | C-Ambient-DDM baseline | NRMSE | 0.113 | split: test · test-subsampling=12.5% · train-subsampling=25% | A Self-Supervised Diffusion Bridge for MRI ReconstructionSource quoteL136: C-Ambient-DDM │ 0.113 │ 0.833 │ 0.056 |
| 2025 | C-Ambient-DDM baseline | SSIM | 0.833 | split: test · test-subsampling=12.5% · train-subsampling=25% | A Self-Supervised Diffusion Bridge for MRI ReconstructionSource quoteL136: C-Ambient-DDM │ 0.113 │ 0.833 │ 0.056 |
| 2025 | C-Ambient-DDM baseline | LPIPS | 0.056 | split: test · test-subsampling=12.5% · train-subsampling=25% | A Self-Supervised Diffusion Bridge for MRI ReconstructionSource quoteL136: C-Ambient-DDM │ 0.113 │ 0.833 │ 0.056 |
| 2025 | DDNM baseline | PSNR | 32.9 | split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01 | Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity EstimationSource quoteL178: DDNM │ \hlgreen{32.9} │ \hlgreen{0.864} │ \hlblue{0.159} |
| 2025 | DDNM baseline | PSNR | 28.6 | split: test · acs-lines=20 · acceleration=×8 · measurement-noise=σ=0.01 | Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity EstimationSource quoteL186: DDNM │ \hlblue{28.6} │ \hlgreen{0.764} │ \hlblue{0.249} |
| 2025 | DDNM baseline | LPIPS | 0.159 | split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01 | Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity EstimationSource quoteL178: DDNM │ \hlgreen{32.9} │ \hlgreen{0.864} │ \hlblue{0.159} |
| 2025 | E2E-VarNet baseline | Precision | 0.610 | split: test · subset=severe-pathology · detector=YOLOv11 | InverseBench: Benchmarking Plug-and-Play Diffusion Priors for Inverse Problems in Physical SciencesSource quoteL439: E2E-VarNet │ 0.610 │ 0.514 │ 0.500 │ 1 │ 32.25 (1.901) │ 0.805 (0.056) │ -- │ 1 |
| 2025 | E2E-VarNet baseline | mAP50 | 0.500 | split: test · subset=severe-pathology · detector=YOLOv11 | InverseBench: Benchmarking Plug-and-Play Diffusion Priors for Inverse Problems in Physical SciencesSource quoteL439: E2E-VarNet │ 0.610 │ 0.514 │ 0.500 │ 1 │ 32.25 (1.901) │ 0.805 (0.056) │ -- │ 1 |
| 2025 | PnP-DM baseline | Recall | 0.579 | split: test · subset=severe-pathology · detector=YOLOv11 | InverseBench: Benchmarking Plug-and-Play Diffusion Priors for Inverse Problems in Physical SciencesSource quoteL447: PnP-DM │ 0.527 │ 0.579 │ 0.500 │ 1 │ 29.85 (2.934) │ 0.730 (0.056) │ 24.324 (10.413) │ 5 |
| 2025 | PnP-DM baseline | mAP50 | 0.500 | split: test · subset=severe-pathology · detector=YOLOv11 | InverseBench: Benchmarking Plug-and-Play Diffusion Priors for Inverse Problems in Physical SciencesSource quoteL447: PnP-DM │ 0.527 │ 0.579 │ 0.500 │ 1 │ 29.85 (2.934) │ 0.730 (0.056) │ 24.324 (10.413) │ 5 |
| 2025 | Prox-DRUNet baseline | PSNR | 35.32 | split: test · noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4 | Multivariate Fields of ExpertsSource quoteL328: Prox-DRUNet │ 35.32 │ 34.53 │ 30.97 │ 31.66 |
| 2025 | ADS baseline | mean SSIM | 91.26 | split: test · subset=knee · k-space-subsampling=25% | Active MRI Acquisition with Diffusion Guided Bayesian Experimental DesignSource quoteL227: ADS \citep{nolan2024} │ 91.26 |
| 2024 | IR-FRestormerF proposed | SSIM | 0.9427 | split: test · coil=multi-coil · anatomy=brain · ensemble=flip · acceleration=8× | IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI ReconstructionSource quoteL265: 0.9427 |
| 2024 | aSeqDIP proposed | PSNR | 34.08 | split: test · undersampling=4× · averaged-scans=20 | Image Reconstruction Via Autoencoding Sequential Deep Image PriorSource quoteL533: 34.08 |
| 2024 | ADS proposed | SSIM | 91.26 | split: test · resolution=128×128 · acceleration=4× · sampling-fraction=25% | Active Diffusion SubsamplingSource quoteL251: While ADS appears to outperform fixed-mask baselines on MNIST, CelebA, and fastMRI, it is interesting to note that the relative improvement offered by ADS is less pronounced in the case of fastMRI. For line-based image subsampling on MNIST with 25% samples, ADS achieves a 50% reduction in reconstruction error versus a fixed-mask approach (MAE = 0.019 vs 0.037), whereas with line-based \kappa-space subsampling for fastMRI with 25% samples, ADS achieves only a 12% relative improvement (SSIM = 91.26 vs 90.13). We find that the size of this performance gap between fixed and active mask design strategies can be explained by examining the distribution of masks designed by ADS on each task (See Appendix \ref{appendix:mask-distributions}). Indeed, the masks designed for fastMRI are very similar, whereas those designed for MNIST typically differ depending on the sample. When mask designs are similar, then fixed masks will perform similarly to actively designed masks. This is in part a feature of the data distribution -- for example, most information in \kappa-space is contained in the center, at lower frequencies. Tasks in which one might expect significantly better performance from ADS are therefore those in which optimal masks will be highly sample-dependent. |
| 2024 | Deform-Mamba (Our) proposed | PSNR | 32.11 | split: test · scale=4× | Deform-Mamba Network for MRI Super-ResolutionSource quoteL180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965 |
| 2024 | Deform-Mamba (Our) proposed | SSIM | 0.7194 | split: test · scale=4× | Deform-Mamba Network for MRI Super-ResolutionSource quoteL180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965 |
| 2024 | Self-Guided DIP (Generalized) proposed | Average reconstruction PSNR | 31.77 dB | split: test · anatomy=knee · variant=Generalized · acceleration=4x · average-images=15 | Analysis of Deep Image Prior and Exploiting Self-Guidance for Image ReconstructionSource quoteL627: 31.77 |
| 2024 | SAFI proposed | PSNR | 36.43 | split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=4-fold · coil-setting=single-coil · patch-resolution=320×320 | Iteratively Refined Image Reconstruction with Learned Attentive RegularizersSource quoteL790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860 |
| 2024 | SAFI proposed | PSNR | 36.06 | split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=8-fold · coil-setting=multi-coil · patch-resolution=320×320 | Iteratively Refined Image Reconstruction with Learned Attentive RegularizersSource quoteL790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860 |
| 2024 | DIRCN [28] baseline | SSIM | 0.9455 | split: test · coil=multi-coil · anatomy=brain · acceleration=8× | IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI ReconstructionSource quoteL262: 0.9455 |
| 2024 | E2E-VarNet [34] baseline | SSIM | 0.9426 | split: test · coil=multi-coil · anatomy=brain · acceleration=8× | IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI ReconstructionSource quoteL268: 0.9426 |
| 2024 | XPDNet [31] baseline | SSIM | 0.9408 | split: test · coil=multi-coil · anatomy=brain · acceleration=8× | IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI ReconstructionSource quoteL271: 0.9408 |
| 2024 | HQS-Net [41] baseline | SSIM | 0.9400 | split: test · coil=multi-coil · anatomy=brain · acceleration=8× | IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI ReconstructionSource quoteL274: 0.9400 |
| 2024 | U-Net [46] baseline | SSIM | 0.9282 | split: test · coil=multi-coil · anatomy=brain · acceleration=8× | IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI ReconstructionSource quoteL277: 0.9282 |
| 2024 | E2E VarNet (trained on 8000 data points from fastMRI) baseline | PSNR | 34.89 | split: test · training-data=8000 data points · undersampling=4× | Image Reconstruction Via Autoencoding Sequential Deep Image PriorSource quoteL528: 34.89 |
| 2024 | Fixed-mask DPS baseline | SSIM | 90.13 | split: test · resolution=128×128 · acceleration=4× · sampling-fraction=25% | Active Diffusion SubsamplingSource quoteL251: While ADS appears to outperform fixed-mask baselines on MNIST, CelebA, and fastMRI, it is interesting to note that the relative improvement offered by ADS is less pronounced in the case of fastMRI. For line-based image subsampling on MNIST with 25% samples, ADS achieves a 50% reduction in reconstruction error versus a fixed-mask approach (MAE = 0.019 vs 0.037), whereas with line-based \kappa-space subsampling for fastMRI with 25% samples, ADS achieves only a 12% relative improvement (SSIM = 91.26 vs 90.13). We find that the size of this performance gap between fixed and active mask design strategies can be explained by examining the distribution of masks designed by ADS on each task (See Appendix \ref{appendix:mask-distributions}). Indeed, the masks designed for fastMRI are very similar, whereas those designed for MNIST typically differ depending on the sample. When mask designs are similar, then fixed masks will perform similarly to actively designed masks. This is in part a feature of the data distribution -- for example, most information in \kappa-space is contained in the center, at lower frequencies. Tasks in which one might expect significantly better performance from ADS are therefore those in which optimal masks will be highly sample-dependent. |
| 2024 | T (2)Net baseline | PSNR | 30.56 | split: test · scale=4× | Deform-Mamba Network for MRI Super-ResolutionSource quoteL178: T (2)Net │ 30.56 │ 0.6244 │ 29.73 │ 0.8773 |
| 2024 | T (2)Net baseline | SSIM | 0.6244 | split: test · scale=4× | Deform-Mamba Network for MRI Super-ResolutionSource quoteL178: T (2)Net │ 30.56 │ 0.6244 │ 29.73 │ 0.8773 |
| 2024 | Vanilla DIP (Generalized) baseline | Average reconstruction PSNR | 28.2 dB | split: test · anatomy=knee · variant=Generalized · acceleration=4x · average-images=15 | Analysis of Deep Image Prior and Exploiting Self-Guidance for Image ReconstructionSource quoteL626: 4x │ 28.2 |
| 2024 | SARR baseline | PSNR | 35.98 | split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=8-fold · coil-setting=multi-coil · patch-resolution=320×320 | Iteratively Refined Image Reconstruction with Learned Attentive RegularizersSource quoteL787: SARR \cite{NeuPouGou2023} │ 36.25 │ 34.77 │ 0.904 │ 0.839 │ 35.98 │ 35.26 │ 0.901 │ 0.858 |
| 2023 | McASSR (Ours; rectangle window 4×16/16×4) proposed | PSNR | 32.52 dB | split: test · scale=4x in-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PD | Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale UpsamplingSource quoteL483: 32.52 |
| 2023 | McASSR (Ours; rectangle window 4×16/16×4) proposed | PSNR | 28.76 dB | split: test · scale=8x out-of-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PD | Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale UpsamplingSource quoteL487: 28.76 |
| 2023 | U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard slice | SSIM | 0.902 | split: test · subset=PDFS knee · test-acceleration=4-fold · training-acceleration=2-, 4-, 8-, and 16-fold | Robustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training DataSource quoteL324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912 |
| 2023 | U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard slice | SSIM | 0.912 | split: test · subset=PDFS knee · test-acceleration=3-fold · training-acceleration=2-, 4-, 8-, and 16-fold | Robustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training DataSource quoteL324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912 |
| 2023 | APMC-PnP proposed | PSNR | 32.70 dB | split: test · acceleration=8× | Provable Probabilistic Imaging using Score-based Generative PriorsSource quoteL1750: APMC-PnP (ours) │ 32.70 │ 36.03 |
| 2023 | APMC-PnP proposed | PSNR | 36.03 dB | split: test · acceleration=4× | Provable Probabilistic Imaging using Score-based Generative PriorsSource quoteL1750: APMC-PnP (ours) │ 32.70 │ 36.03 |
| 2023 | U-net trained on 4-fold acceleration data baseline non-standard slice | SSIM | 0.903 | split: test · subset=PDFS knee · test-acceleration=4-fold · training-acceleration=4-fold | Robustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training DataSource quoteL321: 4-fold │ --- │ 0.903 │ --- │ --- │ 0.899 |
| 2023 | U-net trained on 2-fold acceleration data baseline non-standard slice | SSIM | 0.906 | split: test · subset=PDFS knee · test-acceleration=3-fold · training-acceleration=2-fold | Robustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training DataSource quoteL320: 2-fold │ 0.945 │ --- │ --- │ --- │ 0.906 |
| 2023 | VarNet-8× baseline | PSNR | 32.82 dB | split: test · fine-tuned · model=VarNet · acceleration=8× | Provable Probabilistic Imaging using Score-based Generative PriorsSource quoteL1746: VarNet-8× │ 32.82 │ 35.01 |
| 2023 | VarNet-4× baseline | PSNR | 36.00 dB | split: test · fine-tuned · model=VarNet · acceleration=4× | Provable Probabilistic Imaging using Score-based Generative PriorsSource quoteL1745: VarNet-4× │ 28.51 │ 36.00 |
| 2022 | CRR-NN proposed | PSNR | 40.95 | split: test · coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-fold | A Neural-Network-Based Convex Regularizer for Inverse ProblemsSource quoteL794: CRR-NN │ {\bf 40.95} │ 38.91 │ {\bf 0.961} │ 0.934 │ 33.99 │ 33.75 │ 0.880 │ 0.831 |
| 2022 | LLS (\lambda=10 (-6)) proposed | PSNR | 31.54 | split: test · mask=acceleration=4, center_fraction=0.08 · coils=single-coil · lambda=1e-6 · noise_sigma=0.01 · test_images=99 | Improving Lipschitz-Constrained Neural Networks by Learning Activation FunctionsSource quoteL625: LLS │ 31.54 │ 0.7924 │ 28.04 │ 0.7108 |
| 2022 | FedGIMP proposed | PSNR | 28.4 dB | split: test · coil=single-coil · train-test-operator-shift=3x VD to 6x UD | Federated Learning of Generative Image Priors for MRI ReconstructionSource quoteL420: \multirow{1}{*}{FedGIMP} │ 35.3 │ 96.2 │ 28.4 │ 82.7 │ 46.9 │ 99.3 |
| 2022 | FedGIMP proposed | PSNR | 38.4 dB | split: test · coil=multi-coil · test-acceleration=6x | Federated Learning of Generative Image Priors for MRI ReconstructionSource quoteL542: \multirow{2}{*}{FedGIMP} │ 6x │ 38.4 │ 94.5 |
| 2022 | PnP-\betaCNN baseline | PSNR | 38.77 | split: test · coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-fold | A Neural-Network-Based Convex Regularizer for Inverse ProblemsSource quoteL793: PnP-\betaCNN │ 38.77 │ 37.89 │ 0.943 │ 0.924 │ 31.37 │ 31.82 │ 0.832 │ 0.797 |
| 2022 | AV activation baseline | PSNR | 30.61 | split: test · mask=acceleration=4, center_fraction=0.08 · coils=single-coil · noise_sigma=0.01 · test_images=99 | Improving Lipschitz-Constrained Neural Networks by Learning Activation FunctionsSource quoteL622: AV │ 30.61 │ 0.7721 │ 27.35 │ 0.6921 |
| 2022 | Centralized training baseline | PSNR | 30.47 | split: test · subset=F · setting=centralized · contrast=T2-weighted | Federated Learning With Privacy-Preserving Ensemble Attention DistillationSource quoteL438: F │ 0.9335 │ 34.58 │ 0.9002 │ 30.47 |
| 2022 | FedGAN baseline | PSNR | 26.1 dB | split: test · coil=single-coil · train-test-operator-shift=3x VD to 6x UD | Federated Learning of Generative Image Priors for MRI ReconstructionSource quoteL418: \multirow{1}{*}{FedGAN} │ 32.2 │ 92.4 │ 26.1 │ 79.4 │ 40.2 │ 96.5 |
| 2022 | FedGAN baseline | PSNR | 34.8 dB | split: test · coil=multi-coil · train-test-acceleration=3x to 6x | Federated Learning of Generative Image Priors for MRI ReconstructionSource quoteL537: \multirow{2}{*}{FedGAN} │ 3x\rightarrow6x │ 34.8 │ 91.9 |
| 2022 | NT (normal training) baseline | NMSE | 0.6824 | split: test | On the Robustness of deep learning-based MRI Reconstruction to image transformationsSource quoteL221: 0.0013 │ 0.9442 │ 0.4952 │ 0.4392 │ 0.6824 │ 0.7577 |
| 2021 | DONet proposed non-standard slice | PSNR | 32.780 dB | split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniform | DONet: Dual-Octave Network for Fast MR Image ReconstructionSource quoteL274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data. |
| 2021 | DONet proposed non-standard slice | SSIM | 0.856 | split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniform | DONet: Dual-Octave Network for Fast MR Image ReconstructionSource quoteL274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data. |
| 2021 | Deep Equilibrium (Grad) proposed | Mean PSNR | 32.01 | split: test · roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8× | Deep Equilibrium Architectures for Inverse Problems in ImagingSource quoteL334: PSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38 |
| 2021 | Joint-ICNet proposed | PSNR | 40.7 | split: test · reduction-factor=4 | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quoteL360: 40.7 |
| 2021 | Joint-ICNet proposed | PSNR | 37.3 | split: test · reduction-factor=8 | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quoteL375: 37.3 |
| 2021 | Joint-ICNet proposed | NRMSE | 0.0087 | split: test · reduction-factor=8 | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quoteL374: 0.0087 |
| 2021 | A-DPS (proposed) proposed | NMSE | 0.0342 | split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 | Active Deep Probabilistic SubsamplingSource quoteL293: 0.0342 |
| 2021 | A-DPS (proposed) proposed | PSNR | 30.2 | split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 | Active Deep Probabilistic SubsamplingSource quoteL294: 30.2 |
| 2021 | A-DPS (proposed) proposed | SSIM | 0.654 | split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 | Active Deep Probabilistic SubsamplingSource quoteL295: 0.654 different in that case. Whereas in the previous experiment |
| 2021 | Replace DC with ESPIRiT (Joint-ICNet variant) ablation | PSNR | 39.4 | split: test · reduction-factor=4 | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quoteL364: 39.4 |
| 2021 | Replace DC with ESPIRiT (Joint-ICNet variant) ablation | PSNR | 35.8 | split: test · reduction-factor=8 | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quoteL379: 35.8 |
| 2021 | Replace DC with ESPIRiT (Joint-ICNet variant) ablation | NRMSE | 0.0120 | split: test · reduction-factor=8 | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quoteL378: 0.0120 |
| 2021 | ComplexMRI baseline non-standard slice | PSNR | 29.992 dB | split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniform | DONet: Dual-Octave Network for Fast MR Image ReconstructionSource quoteL274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data. |
| 2021 | ComplexMRI baseline non-standard slice | SSIM | 0.829 | split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniform | DONet: Dual-Octave Network for Fast MR Image ReconstructionSource quoteL274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data. |
| 2021 | Deep Unrolled (Grad) baseline | Mean PSNR | 31.13 | split: test · roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8× | Deep Equilibrium Architectures for Inverse Problems in ImagingSource quoteL334: PSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38 |
| 2021 | DPS baseline | NMSE | 0.0360 | split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 | Active Deep Probabilistic SubsamplingSource quoteL289: 0.0360 |
| 2021 | DPS baseline | PSNR | 30.1 | split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 | Active Deep Probabilistic SubsamplingSource quoteL290: 30.1 |
| 2021 | DPS baseline | SSIM | 0.650 | split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 | Active Deep Probabilistic SubsamplingSource quoteL291: 0.650 |
| 2020 | DeepPhaseCut proposed | PSNR | 19.820 dB | split: test · coil=single-coil · image-type=complex-valued knee images; magnitude metrics · resolution=64×64 · oversampling-ratio=4 | DeepPhaseCut: Deep Relaxation in Phase for Unsupervised Fourier Phase RetrievalSource quoteL628: DeepPhaseCut │ 19.820 │ 0.399 │ 0.042 |
| 2020 | Proposed Co-VeGAN proposed | PSNR | 34.593 dB | split: test · noise=noise-free · undersampling=30% · representation=complex-valued · sampling-pattern=1D-G | Co-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image ReconstructionSource quoteL296: \rule{0pt}{9pt} Proposed │ 1.7M │ 34.593 / 0.7893 │ 34.416 / 0.7870 │ 33.804 / 0.7673 |
| 2020 | Proposed Co-VeGAN proposed | mSSIM | 0.7893 | split: test · noise=noise-free · undersampling=30% · representation=complex-valued · sampling-pattern=1D-G | Co-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image ReconstructionSource quoteL296: \rule{0pt}{9pt} Proposed │ 1.7M │ 34.593 / 0.7893 │ 34.416 / 0.7870 │ 33.804 / 0.7673 |
| 2020 | IFR-Net proposed | HFEN | 0.6119 | split: test · subset=50 knee images · channel=single · data-type=complex-valued · sampling-rate=25% · sampling-pattern=2D-random | IFR-Net: Iterative Feature Refinement Network for Compressed Sensing MRISource quoteL1102: 0.6119 |
| 2020 | PDS-ATM2 proposed | rSNR | 21.00 dB | split: test · coils=4 · subset=10 images · resolution=128×128 · acceleration=4 · measured-snr=15 dB | Autotuning Plug-and-Play Algorithms for MRISource quoteL343: PDS-ATM2 │ 21.00 │ 0.805 │ 21.44 │ 0.817 │ 21.93 │ 0.833 │ 22.33 │ 0.850 |
| 2020 | PDS-ATM2 proposed | rSNR | 22.33 dB | split: test · coils=4 · subset=10 images · resolution=128×128 · acceleration=4 · measured-snr=23 dB | Autotuning Plug-and-Play Algorithms for MRISource quoteL343: PDS-ATM2 │ 21.00 │ 0.805 │ 21.44 │ 0.817 │ 21.93 │ 0.833 │ 22.33 │ 0.850 |
| 2020 | PDS-ATM2 proposed | iterations to convergence | <30 iterations | split: test · coils=4 · resolution=128×128 · acceleration=4 | Autotuning Plug-and-Play Algorithms for MRISource quoteL316: There we see that PDS-ATM2 converges as fast as genie-tuned PDS (i.e., <30 iterations) and significantly faster than PDS-ATO. |
| 2020 | E2E-VN proposed | SSIM | 0.930 | split: test · anatomy=knee · acceleration=4× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL197: E2E-VN │ 0.930 │ 0.005 │ 40 │ 0.890 │ 0.009 │ 37 |
| 2020 | E2E-VN proposed | SSIM | 0.890 | split: test · anatomy=knee · acceleration=8× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL197: E2E-VN │ 0.930 │ 0.005 │ 40 │ 0.890 │ 0.009 │ 37 |
| 2020 | E2E-VN proposed | SSIM | 0.959 | split: test · anatomy=brain · acceleration=4× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL202: Brain │ E2E-VN │ 0.959 │ 0.004 │ 41 │ 0.943 │ 0.008 │ 38 |
| 2020 | E2E-VN proposed | SSIM | 0.943 | split: test · anatomy=brain · acceleration=8× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL202: Brain │ E2E-VN │ 0.959 │ 0.004 │ 41 │ 0.943 │ 0.008 │ 38 |
| 2020 | OT-cycleGAN (Proposed) proposed | PSNR | 28.7426 dB | split: test · coil=single-coil · subset=ESC · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4x | Unpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGANSource quoteL485: \ │ Proposed │ 28.7426 │ 0.6758 \multirow{8}*{Multi-Coil} │ \multirow{4}*{× 4} │ Input │ 28.0524 │ 0.7616 |
| 2020 | OT-cycleGAN (Proposed) proposed | PSNR | 32.1812 dB | split: test · coil=multi-coil (15-coil) · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4x | Unpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGANSource quoteL488: \ │ Proposed │ 32.1812 │ 0.8300 |
| 2020 | PhaseCut baseline | PSNR | 18.217 dB | split: test · coil=single-coil · image-type=complex-valued knee images; magnitude metrics · resolution=64×64 · oversampling-ratio=4 | DeepPhaseCut: Deep Relaxation in Phase for Unsupervised Fourier Phase RetrievalSource quoteL627: PhaseCut │ 18.217 │ 0.395 │ 1390.480 |
| 2020 | DAGAN-based baseline baseline | PSNR | 29.911 dB | split: test · noise=noise-free · undersampling=30% · representation=two real-valued channels · sampling-pattern=1D-G | Co-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image ReconstructionSource quoteL295: \rule{0pt}{9pt} Baseline │ 133M │ 29.911 / 0.5885 │ 29.820 / 0.5885 │ 29.576 / 0.5743 |
| 2020 | DAGAN-based baseline baseline | mSSIM | 0.5885 | split: test · noise=noise-free · undersampling=30% · representation=two real-valued channels · sampling-pattern=1D-G | Co-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image ReconstructionSource quoteL295: \rule{0pt}{9pt} Baseline │ 133M │ 29.911 / 0.5885 │ 29.820 / 0.5885 │ 29.576 / 0.5743 |
| 2020 | D5-C5 baseline | HFEN | 0.7533 | split: test · subset=50 knee images · channel=single · data-type=complex-valued · sampling-rate=25% · sampling-pattern=2D-random | IFR-Net: Iterative Feature Refinement Network for Compressed Sensing MRISource quoteL1101: 0.7533 |
| 2020 | Genie tuned PDS baseline | rSNR | 21.02 dB | split: test · coils=4 · subset=10 images · resolution=128×128 · acceleration=4 · measured-snr=15 dB | Autotuning Plug-and-Play Algorithms for MRISource quoteL341: Genie tuned PDS │ 21.02 │ 0.804 │ 21.42 │ 0.820 │ 21.96 │ 0.839 │ 22.42 │ 0.854 |
| 2020 | Genie tuned PDS baseline | rSNR | 22.42 dB | split: test · coils=4 · subset=10 images · resolution=128×128 · acceleration=4 · measured-snr=23 dB | Autotuning Plug-and-Play Algorithms for MRISource quoteL341: Genie tuned PDS │ 21.02 │ 0.804 │ 21.42 │ 0.820 │ 21.96 │ 0.839 │ 22.42 │ 0.854 |
| 2020 | SubtleMR baseline | SSIM | 0.888 | split: test · anatomy=knee · acceleration=8× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL198: SubtleMR │ 0.929 │ 0.005 │ 40 │ 0.888 │ 0.009 │ 37 |
| 2020 | U-Net baseline | SSIM | 0.915 | split: test · anatomy=brain · acceleration=8× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL203: U-Net │ 0.945 │ 0.011 │ 38 │ 0.915 │ 0.023 │ 35 |
| 2020 | CycleGAN baseline | PSNR | 20.8228 dB | split: test · coil=single-coil · subset=ESC · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4x | Unpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGANSource quoteL483: \ │ CycleGAN │ 20.8228 │ 0.4881 |
| 2020 | Supervised baseline | PSNR | 32.5213 dB | split: test · coil=multi-coil (15-coil) · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4x | Unpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGANSource quoteL487: \ │ Supervised │ 32.5213 │ 0.8315 |
| 2019 | unpaired WGAN proposed | SSIM | 0.822 | split: test · unpaired · training=7 input subjects, 6 disjoint label subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersampling | Wasserstein GANs for MR Imaging: From Paired to Unpaired TrainingSource quoteL217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831 |
| 2019 | WGAN+ℓ₁ proposed | SSIM | 0.824 | split: test · paired · training=6 subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersampling | Wasserstein GANs for MR Imaging: From Paired to Unpaired TrainingSource quoteL217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831 |
| 2019 | ℓ₁-net baseline | SSIM | 0.828 | split: test · paired · training=6 subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersampling | Wasserstein GANs for MR Imaging: From Paired to Unpaired TrainingSource quoteL217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831 |
| 2019 | U-Net reconstruction with LOUPE Unconstrained mask baseline | PSNR | 38.85 | split: test · subgroup=PD · acceleration=8-fold | Deep-Learning-Based Optimization of the Under-Sampling Pattern in MRISource quoteL470: LOUPE Unconstrained │ 0.00014 │ 0.00066 │ 0.0085 │ 0.0199 │ 0.3044 │ 0.4303 │ 38.85 │ 31.83 │ 0.97 │ 0.87 |
| 2019 | U-Net reconstruction with Variable Density mask baseline | PSNR | 35.82 | split: test · subgroup=PD · acceleration=8-fold | Deep-Learning-Based Optimization of the Under-Sampling Pattern in MRISource quoteL468: Variable Density │ 0.00027 │ 0.00074 │ 0.0118 │ 0.0211 │ 0.4746 │ 0.5759 │ 35.82 │ 31.32 │ 0.96 │ 0.87 |
| 2019 | U-Net reconstruction with LOUPE Unconstrained mask baseline | PSNR | 31.83 | split: test · subgroup=PDFS · acceleration=8-fold | Deep-Learning-Based Optimization of the Under-Sampling Pattern in MRISource quoteL470: LOUPE Unconstrained │ 0.00014 │ 0.00066 │ 0.0085 │ 0.0199 │ 0.3044 │ 0.4303 │ 38.85 │ 31.83 │ 0.97 │ 0.87 |
| 2019 | U-Net reconstruction with Variable Density mask baseline | PSNR | 31.32 | split: test · subgroup=PDFS · acceleration=8-fold | Deep-Learning-Based Optimization of the Under-Sampling Pattern in MRISource quoteL468: Variable Density │ 0.00027 │ 0.00074 │ 0.0118 │ 0.0211 │ 0.4746 │ 0.5759 │ 35.82 │ 31.32 │ 0.96 │ 0.87 |
| 2019 | U-Net reconstruction with LOUPE Unconstrained mask baseline | PSNR | 40.71 | split: test · subgroup=PD · acceleration=4-fold | Deep-Learning-Based Optimization of the Under-Sampling Pattern in MRISource quoteL441: LOUPE Unconstrained │ 0.00009 │ 0.00048 │ 0.0071 │ 0.0173 │ 0.1681 │ 0.246 │ 40.71 │ 33.16 │ 0.98 │ 0.91 |
| 2018 | Classical Model (Total Variation) baseline | NMSE | 0.0648 | split: test · coil=single-coil · anatomy=knee | fastMRI: An Open Dataset and Benchmarks for Accelerated MRISource quoteL473: Aggregate │ 0.0648 │ 28.77 │ 0.531 |
| 2018 | U-Net baseline | NMSE | 0.0406 | split: test · coil=single-coil · anatomy=knee | fastMRI: An Open Dataset and Benchmarks for Accelerated MRISource quoteL476: Aggregate │ 0.0406 │ 30.7 │ 0.699 |
| 2018 | Classical Model (Total Variation) baseline | NMSE | 0.0633 | split: test · coil=multi-coil · anatomy=knee | fastMRI: An Open Dataset and Benchmarks for Accelerated MRISource quoteL557: Aggregate │ 0.0633 │ 29.54 │ 0.610 |
| 2018 | U-Net baseline | NMSE | 0.0139 | split: test · coil=multi-coil · anatomy=knee | fastMRI: An Open Dataset and Benchmarks for Accelerated MRISource quoteL560: Aggregate │ 0.0139 │ 34.7 │ 0.881 |
| 2018 | Classical Model (Total Variation) baseline | NMSE | 0.0882 | split: test · coil=multi-coil · anatomy=brain | fastMRI: An Open Dataset and Benchmarks for Accelerated MRISource quoteL564: Aggregate │ 0.0882 │ 29.42 │ 0.4787 |
| 2018 | U-Net baseline | NMSE | 0.017 | split: test · coil=multi-coil · anatomy=brain | fastMRI: An Open Dataset and Benchmarks for Accelerated MRISource quoteL567: Aggregate │ 0.017 │ 36.325 │ 0.9296 |