fastMRI

86 papers · 287 extracted observations · mri reconstruction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

22.829.335.842.3202120242026A-DPS (proposed): 30.2 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 35.8 (2021)Joint-ICNet: 37.3 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 39.4 (2021)Joint-ICNet: 40.7 (2021)Deep Equilibrium (Grad): 32.01 (2021)CRR-NN: 40.95 (2023)LLS (\lambda=10 (-6)): 31.54 (2024)aSeqDIP: 34.08 (2024)Deform-Mamba (Our): 32.11 (2024)SAFI: 36.06 (2024)SAFI: 36.43 (2024)Interleaved (self-supervised loss added during training): 31.55 (2025)DEAL: 36.21 (2025)DEAL: 36.59 (2025)MFoE: 35.4 (2025)Distilled (on-policy privileged information distillation): 24.11 (2026)Distilled (on-policy privileged information distillation): 26.0 (2026)Distilled (on-policy privileged information distillation): 27.86 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 125 of 125 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Distilled (on-policy privileged information distillation) proposedPSNR27.86split: test · contrast=T1 · acceleration=R=32 · undersampling=Gaussian-VDNext-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction
Source quote
L344: Distilled │ 27.86 │ 22.29 │ 24.08 │ 0.81 │ 0.70 │ 0.67 │ 0.148 │ 0.161 │ 0.162
2026Distilled (on-policy privileged information distillation) proposedPSNR24.11split: test · contrast=T1 · acceleration=R=32 · undersampling=ES Cartesian-YNext-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction
Source quote
L354: Distilled │ 24.11 │ 18.42 │ 20.96 │ 0.74 │ 0.55 │ 0.57 │ 0.169 │ 0.230 │ 0.216
2026Distilled (on-policy privileged information distillation) proposedPSNR26.00split: test · contrast=T1 · acceleration=R=32 · undersampling=RadialNext-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction
Source quote
L359: Distilled │ 26.00 │ 20.51 │ 22.68 │ 0.78 │ 0.64 │ 0.63 │ 0.160 │ 0.196 │ 0.186
2026EvoML proposedSSIM0.9498split: test · supervisedValidation-Gated ML Pipeline Synthesis with Expert-Grounded Self-Evolving Skills
Source quote
L975: The margin is largest on the harder tasks, reaching 0.9498
2025Interleaved (self-supervised loss added during training) proposedPSNR31.55split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brainBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L283: Interleaved │ 31.55 │ .7910
2025Interleaved (self-supervised loss added during training) proposedSSIM.7910split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brainBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L283: Interleaved │ 31.55 │ .7910
2025DEAL proposedPSNR36.59split: test · coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32
2025DEAL proposedPSNR36.21split: test · coils=multi-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=8-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32
2025SelfDB proposedNRMSE0.108split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L137: SelfDB │ 0.108 │ 0.882 │ 0.036
2025SelfDB proposedSSIM0.882split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L137: SelfDB │ 0.108 │ 0.882 │ 0.036
2025SelfDB proposedLPIPS0.036split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L137: SelfDB │ 0.108 │ 0.882 │ 0.036
2025C-MSM proposed non-standard slicePSNR32.7split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L179: C\text{-}MSM │ \hlblue{32.7} │ 0.853 │ \hlgreen{0.144} [2pt] \cdashline{1-5} [2pt]
2025C-MSM proposed non-standard slicePSNR28.8split: test · acs-lines=20 · acceleration=×8 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L187: C\text{-}MSM │ \hlgreen{28.8} │ \hlblue{0.760} │ 0.265
2025C-MSM proposed non-standard sliceLPIPS0.144split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L179: C\text{-}MSM │ \hlblue{32.7} │ 0.853 │ \hlgreen{0.144} [2pt] \cdashline{1-5} [2pt]
2025MFoE proposedPSNR35.40split: test · noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4Multivariate Fields of Experts
Source quote
L327: MFoE │ 35.40 │ 34.21 │ 30.26 │ 31.20
2025Supervised learning baseline non-standard slicePSNR32.68split: test · anatomy=knee · training=supervised with oracle ground truth · acceleration=6xBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L414: (Supervised) │ (32.68) │ (.8141)
2025Supervised learning baseline non-standard sliceSSIM.8141split: test · anatomy=knee · training=supervised with oracle ground truth · acceleration=6xBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L414: (Supervised) │ (32.68) │ (.8141)
2025SAFI baselinePSNR36.43split: test · coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L354: SAFI │ 36.43 │ 34.92 │ 36.06 │ 35.36
2025SAFI baselinePSNR36.06split: test · coils=multi-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=8-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L354: SAFI │ 36.43 │ 34.92 │ 36.06 │ 35.36
2025C-Ambient-DDM baselineNRMSE0.113split: test · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L136: C-Ambient-DDM │ 0.113 │ 0.833 │ 0.056
2025C-Ambient-DDM baselineSSIM0.833split: test · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L136: C-Ambient-DDM │ 0.113 │ 0.833 │ 0.056
2025C-Ambient-DDM baselineLPIPS0.056split: test · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L136: C-Ambient-DDM │ 0.113 │ 0.833 │ 0.056
2025DDNM baselinePSNR32.9split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L178: DDNM │ \hlgreen{32.9} │ \hlgreen{0.864} │ \hlblue{0.159}
2025DDNM baselinePSNR28.6split: test · acs-lines=20 · acceleration=×8 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L186: DDNM │ \hlblue{28.6} │ \hlgreen{0.764} │ \hlblue{0.249}
2025DDNM baselineLPIPS0.159split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L178: DDNM │ \hlgreen{32.9} │ \hlgreen{0.864} │ \hlblue{0.159}
2025E2E-VarNet baselinePrecision0.610split: test · subset=severe-pathology · detector=YOLOv11InverseBench: Benchmarking Plug-and-Play Diffusion Priors for Inverse Problems in Physical Sciences
Source quote
L439: E2E-VarNet │ 0.610 │ 0.514 │ 0.500 │ 1 │ 32.25 (1.901) │ 0.805 (0.056) │ -- │ 1
2025E2E-VarNet baselinemAP500.500split: test · subset=severe-pathology · detector=YOLOv11InverseBench: Benchmarking Plug-and-Play Diffusion Priors for Inverse Problems in Physical Sciences
Source quote
L439: E2E-VarNet │ 0.610 │ 0.514 │ 0.500 │ 1 │ 32.25 (1.901) │ 0.805 (0.056) │ -- │ 1
2025PnP-DM baselineRecall0.579split: test · subset=severe-pathology · detector=YOLOv11InverseBench: Benchmarking Plug-and-Play Diffusion Priors for Inverse Problems in Physical Sciences
Source quote
L447: PnP-DM │ 0.527 │ 0.579 │ 0.500 │ 1 │ 29.85 (2.934) │ 0.730 (0.056) │ 24.324 (10.413) │ 5
2025PnP-DM baselinemAP500.500split: test · subset=severe-pathology · detector=YOLOv11InverseBench: Benchmarking Plug-and-Play Diffusion Priors for Inverse Problems in Physical Sciences
Source quote
L447: PnP-DM │ 0.527 │ 0.579 │ 0.500 │ 1 │ 29.85 (2.934) │ 0.730 (0.056) │ 24.324 (10.413) │ 5
2025Prox-DRUNet baselinePSNR35.32split: test · noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4Multivariate Fields of Experts
Source quote
L328: Prox-DRUNet │ 35.32 │ 34.53 │ 30.97 │ 31.66
2025ADS baselinemean SSIM91.26split: test · subset=knee · k-space-subsampling=25%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L227: ADS \citep{nolan2024} │ 91.26
2024IR-FRestormerF proposedSSIM0.9427split: test · coil=multi-coil · anatomy=brain · ensemble=flip · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L265: 0.9427
2024aSeqDIP proposedPSNR34.08split: test · undersampling=4× · averaged-scans=20Image Reconstruction Via Autoencoding Sequential Deep Image Prior
Source quote
L533: 34.08
2024ADS proposedSSIM91.26split: test · resolution=128×128 · acceleration=4× · sampling-fraction=25%Active Diffusion Subsampling
Source quote
L251: While ADS appears to outperform fixed-mask baselines on MNIST, CelebA, and fastMRI, it is interesting to note that the relative improvement offered by ADS is less pronounced in the case of fastMRI. For line-based image subsampling on MNIST with 25% samples, ADS achieves a 50% reduction in reconstruction error versus a fixed-mask approach (MAE = 0.019 vs 0.037), whereas with line-based \kappa-space subsampling for fastMRI with 25% samples, ADS achieves only a 12% relative improvement (SSIM = 91.26 vs 90.13). We find that the size of this performance gap between fixed and active mask design strategies can be explained by examining the distribution of masks designed by ADS on each task (See Appendix \ref{appendix:mask-distributions}). Indeed, the masks designed for fastMRI are very similar, whereas those designed for MNIST typically differ depending on the sample. When mask designs are similar, then fixed masks will perform similarly to actively designed masks. This is in part a feature of the data distribution -- for example, most information in \kappa-space is contained in the center, at lower frequencies. Tasks in which one might expect significantly better performance from ADS are therefore those in which optimal masks will be highly sample-dependent.
2024Deform-Mamba (Our) proposedPSNR32.11split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965
2024Deform-Mamba (Our) proposedSSIM0.7194split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965
2024Self-Guided DIP (Generalized) proposedAverage reconstruction PSNR31.77 dBsplit: test · anatomy=knee · variant=Generalized · acceleration=4x · average-images=15Analysis of Deep Image Prior and Exploiting Self-Guidance for Image Reconstruction
Source quote
L627: 31.77
2024SAFI proposedPSNR36.43split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=4-fold · coil-setting=single-coil · patch-resolution=320×320Iteratively Refined Image Reconstruction with Learned Attentive Regularizers
Source quote
L790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860
2024SAFI proposedPSNR36.06split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=8-fold · coil-setting=multi-coil · patch-resolution=320×320Iteratively Refined Image Reconstruction with Learned Attentive Regularizers
Source quote
L790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860
2024DIRCN [28] baselineSSIM0.9455split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L262: 0.9455
2024E2E-VarNet [34] baselineSSIM0.9426split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L268: 0.9426
2024XPDNet [31] baselineSSIM0.9408split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L271: 0.9408
2024HQS-Net [41] baselineSSIM0.9400split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L274: 0.9400
2024U-Net [46] baselineSSIM0.9282split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L277: 0.9282
2024E2E VarNet (trained on 8000 data points from fastMRI) baselinePSNR34.89split: test · training-data=8000 data points · undersampling=4×Image Reconstruction Via Autoencoding Sequential Deep Image Prior
Source quote
L528: 34.89
2024Fixed-mask DPS baselineSSIM90.13split: test · resolution=128×128 · acceleration=4× · sampling-fraction=25%Active Diffusion Subsampling
Source quote
L251: While ADS appears to outperform fixed-mask baselines on MNIST, CelebA, and fastMRI, it is interesting to note that the relative improvement offered by ADS is less pronounced in the case of fastMRI. For line-based image subsampling on MNIST with 25% samples, ADS achieves a 50% reduction in reconstruction error versus a fixed-mask approach (MAE = 0.019 vs 0.037), whereas with line-based \kappa-space subsampling for fastMRI with 25% samples, ADS achieves only a 12% relative improvement (SSIM = 91.26 vs 90.13). We find that the size of this performance gap between fixed and active mask design strategies can be explained by examining the distribution of masks designed by ADS on each task (See Appendix \ref{appendix:mask-distributions}). Indeed, the masks designed for fastMRI are very similar, whereas those designed for MNIST typically differ depending on the sample. When mask designs are similar, then fixed masks will perform similarly to actively designed masks. This is in part a feature of the data distribution -- for example, most information in \kappa-space is contained in the center, at lower frequencies. Tasks in which one might expect significantly better performance from ADS are therefore those in which optimal masks will be highly sample-dependent.
2024T (2)Net baselinePSNR30.56split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L178: T (2)Net │ 30.56 │ 0.6244 │ 29.73 │ 0.8773
2024T (2)Net baselineSSIM0.6244split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L178: T (2)Net │ 30.56 │ 0.6244 │ 29.73 │ 0.8773
2024Vanilla DIP (Generalized) baselineAverage reconstruction PSNR28.2 dBsplit: test · anatomy=knee · variant=Generalized · acceleration=4x · average-images=15Analysis of Deep Image Prior and Exploiting Self-Guidance for Image Reconstruction
Source quote
L626: 4x │ 28.2
2024SARR baselinePSNR35.98split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=8-fold · coil-setting=multi-coil · patch-resolution=320×320Iteratively Refined Image Reconstruction with Learned Attentive Regularizers
Source quote
L787: SARR \cite{NeuPouGou2023} │ 36.25 │ 34.77 │ 0.904 │ 0.839 │ 35.98 │ 35.26 │ 0.901 │ 0.858
2023McASSR (Ours; rectangle window 4×16/16×4) proposedPSNR32.52 dBsplit: test · scale=4x in-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PDRethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L483: 32.52
2023McASSR (Ours; rectangle window 4×16/16×4) proposedPSNR28.76 dBsplit: test · scale=8x out-of-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PDRethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L487: 28.76
2023U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard sliceSSIM0.902split: test · subset=PDFS knee · test-acceleration=4-fold · training-acceleration=2-, 4-, 8-, and 16-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912
2023U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard sliceSSIM0.912split: test · subset=PDFS knee · test-acceleration=3-fold · training-acceleration=2-, 4-, 8-, and 16-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912
2023APMC-PnP proposedPSNR32.70 dBsplit: test · acceleration=8×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1750: APMC-PnP (ours) │ 32.70 │ 36.03
2023APMC-PnP proposedPSNR36.03 dBsplit: test · acceleration=4×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1750: APMC-PnP (ours) │ 32.70 │ 36.03
2023U-net trained on 4-fold acceleration data baseline non-standard sliceSSIM0.903split: test · subset=PDFS knee · test-acceleration=4-fold · training-acceleration=4-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L321: 4-fold │ --- │ 0.903 │ --- │ --- │ 0.899
2023U-net trained on 2-fold acceleration data baseline non-standard sliceSSIM0.906split: test · subset=PDFS knee · test-acceleration=3-fold · training-acceleration=2-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L320: 2-fold │ 0.945 │ --- │ --- │ --- │ 0.906
2023VarNet-8× baselinePSNR32.82 dBsplit: test · fine-tuned · model=VarNet · acceleration=8×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1746: VarNet-8× │ 32.82 │ 35.01
2023VarNet-4× baselinePSNR36.00 dBsplit: test · fine-tuned · model=VarNet · acceleration=4×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1745: VarNet-4× │ 28.51 │ 36.00
2022CRR-NN proposedPSNR40.95split: test · coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-foldA Neural-Network-Based Convex Regularizer for Inverse Problems
Source quote
L794: CRR-NN │ {\bf 40.95} │ 38.91 │ {\bf 0.961} │ 0.934 │ 33.99 │ 33.75 │ 0.880 │ 0.831
2022LLS (\lambda=10 (-6)) proposedPSNR31.54split: test · mask=acceleration=4, center_fraction=0.08 · coils=single-coil · lambda=1e-6 · noise_sigma=0.01 · test_images=99Improving Lipschitz-Constrained Neural Networks by Learning Activation Functions
Source quote
L625: LLS │ 31.54 │ 0.7924 │ 28.04 │ 0.7108
2022FedGIMP proposedPSNR28.4 dBsplit: test · coil=single-coil · train-test-operator-shift=3x VD to 6x UDFederated Learning of Generative Image Priors for MRI Reconstruction
Source quote
L420: \multirow{1}{*}{FedGIMP} │ 35.3 │ 96.2 │ 28.4 │ 82.7 │ 46.9 │ 99.3
2022FedGIMP proposedPSNR38.4 dBsplit: test · coil=multi-coil · test-acceleration=6xFederated Learning of Generative Image Priors for MRI Reconstruction
Source quote
L542: \multirow{2}{*}{FedGIMP} │ 6x │ 38.4 │ 94.5
2022PnP-\betaCNN baselinePSNR38.77split: test · coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-foldA Neural-Network-Based Convex Regularizer for Inverse Problems
Source quote
L793: PnP-\betaCNN │ 38.77 │ 37.89 │ 0.943 │ 0.924 │ 31.37 │ 31.82 │ 0.832 │ 0.797
2022AV activation baselinePSNR30.61split: test · mask=acceleration=4, center_fraction=0.08 · coils=single-coil · noise_sigma=0.01 · test_images=99Improving Lipschitz-Constrained Neural Networks by Learning Activation Functions
Source quote
L622: AV │ 30.61 │ 0.7721 │ 27.35 │ 0.6921
2022Centralized training baselinePSNR30.47split: test · subset=F · setting=centralized · contrast=T2-weightedFederated Learning With Privacy-Preserving Ensemble Attention Distillation
Source quote
L438: F │ 0.9335 │ 34.58 │ 0.9002 │ 30.47
2022FedGAN baselinePSNR26.1 dBsplit: test · coil=single-coil · train-test-operator-shift=3x VD to 6x UDFederated Learning of Generative Image Priors for MRI Reconstruction
Source quote
L418: \multirow{1}{*}{FedGAN} │ 32.2 │ 92.4 │ 26.1 │ 79.4 │ 40.2 │ 96.5
2022FedGAN baselinePSNR34.8 dBsplit: test · coil=multi-coil · train-test-acceleration=3x to 6xFederated Learning of Generative Image Priors for MRI Reconstruction
Source quote
L537: \multirow{2}{*}{FedGAN} │ 3x\rightarrow6x │ 34.8 │ 91.9
2022NT (normal training) baselineNMSE0.6824split: testOn the Robustness of deep learning-based MRI Reconstruction to image transformations
Source quote
L221: 0.0013 │ 0.9442 │ 0.4952 │ 0.4392 │ 0.6824 │ 0.7577
2021DONet proposed non-standard slicePSNR32.780 dBsplit: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniformDONet: Dual-Octave Network for Fast MR Image Reconstruction
Source quote
L274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data.
2021DONet proposed non-standard sliceSSIM0.856split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniformDONet: Dual-Octave Network for Fast MR Image Reconstruction
Source quote
L274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data.
2021Deep Equilibrium (Grad) proposedMean PSNR32.01split: test · roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8×Deep Equilibrium Architectures for Inverse Problems in Imaging
Source quote
L334: PSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38
2021Joint-ICNet proposedPSNR40.7split: test · reduction-factor=4Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L360: 40.7
2021Joint-ICNet proposedPSNR37.3split: test · reduction-factor=8Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L375: 37.3
2021Joint-ICNet proposedNRMSE0.0087split: test · reduction-factor=8Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L374: 0.0087
2021A-DPS (proposed) proposedNMSE0.0342split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L293: 0.0342
2021A-DPS (proposed) proposedPSNR30.2split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L294: 30.2
2021A-DPS (proposed) proposedSSIM0.654split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L295: 0.654 different in that case. Whereas in the previous experiment
2021Replace DC with ESPIRiT (Joint-ICNet variant) ablationPSNR39.4split: test · reduction-factor=4Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L364: 39.4
2021Replace DC with ESPIRiT (Joint-ICNet variant) ablationPSNR35.8split: test · reduction-factor=8Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L379: 35.8
2021Replace DC with ESPIRiT (Joint-ICNet variant) ablationNRMSE0.0120split: test · reduction-factor=8Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L378: 0.0120
2021ComplexMRI baseline non-standard slicePSNR29.992 dBsplit: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniformDONet: Dual-Octave Network for Fast MR Image Reconstruction
Source quote
L274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data.
2021ComplexMRI baseline non-standard sliceSSIM0.829split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniformDONet: Dual-Octave Network for Fast MR Image Reconstruction
Source quote
L274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data.
2021Deep Unrolled (Grad) baselineMean PSNR31.13split: test · roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8×Deep Equilibrium Architectures for Inverse Problems in Imaging
Source quote
L334: PSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38
2021DPS baselineNMSE0.0360split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L289: 0.0360
2021DPS baselinePSNR30.1split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L290: 30.1
2021DPS baselineSSIM0.650split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L291: 0.650
2020DeepPhaseCut proposedPSNR19.820 dBsplit: test · coil=single-coil · image-type=complex-valued knee images; magnitude metrics · resolution=64×64 · oversampling-ratio=4DeepPhaseCut: Deep Relaxation in Phase for Unsupervised Fourier Phase Retrieval
Source quote
L628: DeepPhaseCut │ 19.820 │ 0.399 │ 0.042
2020Proposed Co-VeGAN proposedPSNR34.593 dBsplit: test · noise=noise-free · undersampling=30% · representation=complex-valued · sampling-pattern=1D-GCo-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image Reconstruction
Source quote
L296: \rule{0pt}{9pt} Proposed │ 1.7M │ 34.593 / 0.7893 │ 34.416 / 0.7870 │ 33.804 / 0.7673
2020Proposed Co-VeGAN proposedmSSIM0.7893split: test · noise=noise-free · undersampling=30% · representation=complex-valued · sampling-pattern=1D-GCo-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image Reconstruction
Source quote
L296: \rule{0pt}{9pt} Proposed │ 1.7M │ 34.593 / 0.7893 │ 34.416 / 0.7870 │ 33.804 / 0.7673
2020IFR-Net proposedHFEN0.6119split: test · subset=50 knee images · channel=single · data-type=complex-valued · sampling-rate=25% · sampling-pattern=2D-randomIFR-Net: Iterative Feature Refinement Network for Compressed Sensing MRI
Source quote
L1102: 0.6119
2020PDS-ATM2 proposedrSNR21.00 dBsplit: test · coils=4 · subset=10 images · resolution=128×128 · acceleration=4 · measured-snr=15 dBAutotuning Plug-and-Play Algorithms for MRI
Source quote
L343: PDS-ATM2 │ 21.00 │ 0.805 │ 21.44 │ 0.817 │ 21.93 │ 0.833 │ 22.33 │ 0.850
2020PDS-ATM2 proposedrSNR22.33 dBsplit: test · coils=4 · subset=10 images · resolution=128×128 · acceleration=4 · measured-snr=23 dBAutotuning Plug-and-Play Algorithms for MRI
Source quote
L343: PDS-ATM2 │ 21.00 │ 0.805 │ 21.44 │ 0.817 │ 21.93 │ 0.833 │ 22.33 │ 0.850
2020PDS-ATM2 proposediterations to convergence<30 iterationssplit: test · coils=4 · resolution=128×128 · acceleration=4Autotuning Plug-and-Play Algorithms for MRI
Source quote
L316: There we see that PDS-ATM2 converges as fast as genie-tuned PDS (i.e., <30 iterations) and significantly faster than PDS-ATO.
2020E2E-VN proposedSSIM0.930split: test · anatomy=knee · acceleration=4×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L197: E2E-VN │ 0.930 │ 0.005 │ 40 │ 0.890 │ 0.009 │ 37
2020E2E-VN proposedSSIM0.890split: test · anatomy=knee · acceleration=8×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L197: E2E-VN │ 0.930 │ 0.005 │ 40 │ 0.890 │ 0.009 │ 37
2020E2E-VN proposedSSIM0.959split: test · anatomy=brain · acceleration=4×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L202: Brain │ E2E-VN │ 0.959 │ 0.004 │ 41 │ 0.943 │ 0.008 │ 38
2020E2E-VN proposedSSIM0.943split: test · anatomy=brain · acceleration=8×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L202: Brain │ E2E-VN │ 0.959 │ 0.004 │ 41 │ 0.943 │ 0.008 │ 38
2020OT-cycleGAN (Proposed) proposedPSNR28.7426 dBsplit: test · coil=single-coil · subset=ESC · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4xUnpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGAN
Source quote
L485: \ │ Proposed │ 28.7426 │ 0.6758 \multirow{8}*{Multi-Coil} │ \multirow{4}*{× 4} │ Input │ 28.0524 │ 0.7616
2020OT-cycleGAN (Proposed) proposedPSNR32.1812 dBsplit: test · coil=multi-coil (15-coil) · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4xUnpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGAN
Source quote
L488: \ │ Proposed │ 32.1812 │ 0.8300
2020PhaseCut baselinePSNR18.217 dBsplit: test · coil=single-coil · image-type=complex-valued knee images; magnitude metrics · resolution=64×64 · oversampling-ratio=4DeepPhaseCut: Deep Relaxation in Phase for Unsupervised Fourier Phase Retrieval
Source quote
L627: PhaseCut │ 18.217 │ 0.395 │ 1390.480
2020DAGAN-based baseline baselinePSNR29.911 dBsplit: test · noise=noise-free · undersampling=30% · representation=two real-valued channels · sampling-pattern=1D-GCo-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image Reconstruction
Source quote
L295: \rule{0pt}{9pt} Baseline │ 133M │ 29.911 / 0.5885 │ 29.820 / 0.5885 │ 29.576 / 0.5743
2020DAGAN-based baseline baselinemSSIM0.5885split: test · noise=noise-free · undersampling=30% · representation=two real-valued channels · sampling-pattern=1D-GCo-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image Reconstruction
Source quote
L295: \rule{0pt}{9pt} Baseline │ 133M │ 29.911 / 0.5885 │ 29.820 / 0.5885 │ 29.576 / 0.5743
2020D5-C5 baselineHFEN0.7533split: test · subset=50 knee images · channel=single · data-type=complex-valued · sampling-rate=25% · sampling-pattern=2D-randomIFR-Net: Iterative Feature Refinement Network for Compressed Sensing MRI
Source quote
L1101: 0.7533
2020Genie tuned PDS baselinerSNR21.02 dBsplit: test · coils=4 · subset=10 images · resolution=128×128 · acceleration=4 · measured-snr=15 dBAutotuning Plug-and-Play Algorithms for MRI
Source quote
L341: Genie tuned PDS │ 21.02 │ 0.804 │ 21.42 │ 0.820 │ 21.96 │ 0.839 │ 22.42 │ 0.854
2020Genie tuned PDS baselinerSNR22.42 dBsplit: test · coils=4 · subset=10 images · resolution=128×128 · acceleration=4 · measured-snr=23 dBAutotuning Plug-and-Play Algorithms for MRI
Source quote
L341: Genie tuned PDS │ 21.02 │ 0.804 │ 21.42 │ 0.820 │ 21.96 │ 0.839 │ 22.42 │ 0.854
2020SubtleMR baselineSSIM0.888split: test · anatomy=knee · acceleration=8×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L198: SubtleMR │ 0.929 │ 0.005 │ 40 │ 0.888 │ 0.009 │ 37
2020U-Net baselineSSIM0.915split: test · anatomy=brain · acceleration=8×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L203: U-Net │ 0.945 │ 0.011 │ 38 │ 0.915 │ 0.023 │ 35
2020CycleGAN baselinePSNR20.8228 dBsplit: test · coil=single-coil · subset=ESC · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4xUnpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGAN
Source quote
L483: \ │ CycleGAN │ 20.8228 │ 0.4881
2020Supervised baselinePSNR32.5213 dBsplit: test · coil=multi-coil (15-coil) · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4xUnpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGAN
Source quote
L487: \ │ Supervised │ 32.5213 │ 0.8315
2019unpaired WGAN proposedSSIM0.822split: test · unpaired · training=7 input subjects, 6 disjoint label subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersamplingWasserstein GANs for MR Imaging: From Paired to Unpaired Training
Source quote
L217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831
2019WGAN+ℓ₁ proposedSSIM0.824split: test · paired · training=6 subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersamplingWasserstein GANs for MR Imaging: From Paired to Unpaired Training
Source quote
L217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831
2019ℓ₁-net baselineSSIM0.828split: test · paired · training=6 subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersamplingWasserstein GANs for MR Imaging: From Paired to Unpaired Training
Source quote
L217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831
2019U-Net reconstruction with LOUPE Unconstrained mask baselinePSNR38.85split: test · subgroup=PD · acceleration=8-foldDeep-Learning-Based Optimization of the Under-Sampling Pattern in MRI
Source quote
L470: LOUPE Unconstrained │ 0.00014 │ 0.00066 │ 0.0085 │ 0.0199 │ 0.3044 │ 0.4303 │ 38.85 │ 31.83 │ 0.97 │ 0.87
2019U-Net reconstruction with Variable Density mask baselinePSNR35.82split: test · subgroup=PD · acceleration=8-foldDeep-Learning-Based Optimization of the Under-Sampling Pattern in MRI
Source quote
L468: Variable Density │ 0.00027 │ 0.00074 │ 0.0118 │ 0.0211 │ 0.4746 │ 0.5759 │ 35.82 │ 31.32 │ 0.96 │ 0.87
2019U-Net reconstruction with LOUPE Unconstrained mask baselinePSNR31.83split: test · subgroup=PDFS · acceleration=8-foldDeep-Learning-Based Optimization of the Under-Sampling Pattern in MRI
Source quote
L470: LOUPE Unconstrained │ 0.00014 │ 0.00066 │ 0.0085 │ 0.0199 │ 0.3044 │ 0.4303 │ 38.85 │ 31.83 │ 0.97 │ 0.87
2019U-Net reconstruction with Variable Density mask baselinePSNR31.32split: test · subgroup=PDFS · acceleration=8-foldDeep-Learning-Based Optimization of the Under-Sampling Pattern in MRI
Source quote
L468: Variable Density │ 0.00027 │ 0.00074 │ 0.0118 │ 0.0211 │ 0.4746 │ 0.5759 │ 35.82 │ 31.32 │ 0.96 │ 0.87
2019U-Net reconstruction with LOUPE Unconstrained mask baselinePSNR40.71split: test · subgroup=PD · acceleration=4-foldDeep-Learning-Based Optimization of the Under-Sampling Pattern in MRI
Source quote
L441: LOUPE Unconstrained │ 0.00009 │ 0.00048 │ 0.0071 │ 0.0173 │ 0.1681 │ 0.246 │ 40.71 │ 33.16 │ 0.98 │ 0.91
2018Classical Model (Total Variation) baselineNMSE0.0648split: test · coil=single-coil · anatomy=kneefastMRI: An Open Dataset and Benchmarks for Accelerated MRI
Source quote
L473: Aggregate │ 0.0648 │ 28.77 │ 0.531
2018U-Net baselineNMSE0.0406split: test · coil=single-coil · anatomy=kneefastMRI: An Open Dataset and Benchmarks for Accelerated MRI
Source quote
L476: Aggregate │ 0.0406 │ 30.7 │ 0.699
2018Classical Model (Total Variation) baselineNMSE0.0633split: test · coil=multi-coil · anatomy=kneefastMRI: An Open Dataset and Benchmarks for Accelerated MRI
Source quote
L557: Aggregate │ 0.0633 │ 29.54 │ 0.610
2018U-Net baselineNMSE0.0139split: test · coil=multi-coil · anatomy=kneefastMRI: An Open Dataset and Benchmarks for Accelerated MRI
Source quote
L560: Aggregate │ 0.0139 │ 34.7 │ 0.881
2018Classical Model (Total Variation) baselineNMSE0.0882split: test · coil=multi-coil · anatomy=brainfastMRI: An Open Dataset and Benchmarks for Accelerated MRI
Source quote
L564: Aggregate │ 0.0882 │ 29.42 │ 0.4787
2018U-Net baselineNMSE0.017split: test · coil=multi-coil · anatomy=brainfastMRI: An Open Dataset and Benchmarks for Accelerated MRI
Source quote
L567: Aggregate │ 0.017 │ 36.325 │ 0.9296