fastMRI

86 papers · 287 extracted observations · mri reconstruction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

22.829.335.842.3202120242026A-DPS (proposed): 30.2 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 35.8 (2021)Joint-ICNet: 37.3 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 39.4 (2021)Joint-ICNet: 40.7 (2021)Deep Equilibrium (Grad): 32.01 (2021)CRR-NN: 40.95 (2023)LLS (\lambda=10 (-6)): 31.54 (2024)aSeqDIP: 34.08 (2024)Deform-Mamba (Our): 32.11 (2024)SAFI: 36.06 (2024)SAFI: 36.43 (2024)Interleaved (self-supervised loss added during training): 31.55 (2025)DEAL: 36.21 (2025)DEAL: 36.59 (2025)MFoE: 35.4 (2025)Distilled (on-policy privileged information distillation): 24.11 (2026)Distilled (on-policy privileged information distillation): 26.0 (2026)Distilled (on-policy privileged information distillation): 27.86 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 144 of 144 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Distilled (on-policy privileged information distillation) proposedPSNR27.86split: test · contrast=T1 · acceleration=R=32 · undersampling=Gaussian-VDNext-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction
Source quote
L344: Distilled │ 27.86 │ 22.29 │ 24.08 │ 0.81 │ 0.70 │ 0.67 │ 0.148 │ 0.161 │ 0.162
2026Distilled (on-policy privileged information distillation) proposedPSNR24.11split: test · contrast=T1 · acceleration=R=32 · undersampling=ES Cartesian-YNext-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction
Source quote
L354: Distilled │ 24.11 │ 18.42 │ 20.96 │ 0.74 │ 0.55 │ 0.57 │ 0.169 │ 0.230 │ 0.216
2026Distilled (on-policy privileged information distillation) proposedPSNR26.00split: test · contrast=T1 · acceleration=R=32 · undersampling=RadialNext-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction
Source quote
L359: Distilled │ 26.00 │ 20.51 │ 22.68 │ 0.78 │ 0.64 │ 0.63 │ 0.160 │ 0.196 │ 0.186
2026OCDI-Net proposedPSNR41.88SMS=MB3R1 · subset=T2 · reconstruction=single-stage SMS unaliasing · image-representation=RSS magnitudeBack to Physics: Operator-Guided Generative Paths for SMS MRI Reconstruction
Source quote
L619: OCDI-Net │ 41.88 │ 0.966 │ \boldsymbol{2.5× 10 (-3)}
2026OCDI-Net proposedSSIM0.966SMS=MB3R1 · subset=T2 · reconstruction=single-stage SMS unaliasing · image-representation=RSS magnitudeBack to Physics: Operator-Guided Generative Paths for SMS MRI Reconstruction
Source quote
L619: OCDI-Net │ 41.88 │ 0.966 │ \boldsymbol{2.5× 10 (-3)}
2026SGPnP-PGM (Decouple) proposedPSNR32.54acceleration=4x · noise-levels=decoupledStochastic Generative Plug-and-Play Priors
Source quote
L753: \multicolumn{1}{c}{\hlgreen{32.91}} │ \multicolumn{1}{c}{31.44} │ \multicolumn{1}{c}{\hlgreen{33.32}} │ \multicolumn{1}{c}{30.20} │ \multicolumn{1}{c}{\hlgreen{32.54}} \\[+.95ex]
2026EvoML proposedSSIM0.9498split: test · supervisedValidation-Gated ML Pipeline Synthesis with Expert-Grounded Self-Evolving Skills
Source quote
L975: The margin is largest on the harder tasks, reaching 0.9498
2026GEO proposedSSFD6.67anatomy=brain · acceleration=×8Anatomical Token Uncertainty for Transformer-Guided Active MRI Acquisition
Source quote
L104: GEO (Ours) │ Transformer │ 27.26 │ 0.6783 │ 0.0407 │ 2.96 │ 0.13 │ 6.67
2026GEO proposedSSFD8.82anatomy=knee · acceleration=×16Anatomical Token Uncertainty for Transformer-Guided Active MRI Acquisition
Source quote
L96: GEO (Ours) │ Transformer │ 28.61 │ 0.5983 │ 0.0653 │ 4.11 │ 0.18 │ 8.82
2026PAS-Mamba proposedPSNR32.46Radial mask, ×2 acceleration.PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI Reconstruction
Source quote
L241: Ours │ 32.46 │ 0.8838 │ 28.84 │ 0.8301
2026PAS-Mamba proposedSSIM0.8838Radial mask, ×2 acceleration.PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI Reconstruction
Source quote
L241: Ours │ 32.46 │ 0.8838 │ 28.84 │ 0.8301
2026PAS-Mamba proposedPSNR26.47Cartesian mask, ×4 acceleration.PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI Reconstruction
Source quote
L249: Ours │ 28.35 │ 0.7058 │ 26.47 │ 0.7081
2026PAS-Mamba proposedSSIM0.7081Cartesian mask, ×4 acceleration.PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI Reconstruction
Source quote
L249: Ours │ 28.35 │ 0.7058 │ 26.47 │ 0.7081
2025SDUM proposedPSNR42.6 dBcoils=multi-coil · anatomy=brain · acceleration=4× · unrolling-steps=6SDUM: A Scalable Deep Unrolled Model for Universal MRI Reconstruction
Source quote
L403: SDUM (Ours) │ 0.979 │ \multicolumn{1}{c|}{42.6} │ 0.973 │ 40.8
2025PR-INR proposedPSNR33.3 dBmotion-displacement=3%From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction
Source quote
L617: Table~\ref{tab:ablation_final} shows that the full configuration of our PR-INR framework consistently achieves the best performance across all undersampling settings on both the FastMRI and HCP 1200 datasets. At 3% and 5% displacement during acquisition, the complete model achieves strong gains over the baseline. For instance, PSNR/SSIM improves from 30.0/0.853 to 33.3/0.919 on FastMRI, and from 24.3/0.820 to 27.0/0.904 on HCP 1200 at 3%, with similar trends at 5%. Under 4x and 8x undersampling, PR-INR remains robust, consistently outperforming variants. At 8x, it improves PSNR from 23.9 to 26.4 and SSIM from 0.645 to 0.721 on FastMRI, and shows comparable improvements on HCP. The IDR module plays a key role in enhancing perceptual and structural quality (e.g., LPIPS drops and SSIM improves), while the VCR module further enforces volumetric smoothness, reflected in higher NCC values. These results validate the complementary contributions of each module and the generalizability of PR-INR across different datasets and acceleration regimes.
2025PR-INR proposedSSIM0.919motion-displacement=3%From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction
Source quote
L617: Table~\ref{tab:ablation_final} shows that the full configuration of our PR-INR framework consistently achieves the best performance across all undersampling settings on both the FastMRI and HCP 1200 datasets. At 3% and 5% displacement during acquisition, the complete model achieves strong gains over the baseline. For instance, PSNR/SSIM improves from 30.0/0.853 to 33.3/0.919 on FastMRI, and from 24.3/0.820 to 27.0/0.904 on HCP 1200 at 3%, with similar trends at 5%. Under 4x and 8x undersampling, PR-INR remains robust, consistently outperforming variants. At 8x, it improves PSNR from 23.9 to 26.4 and SSIM from 0.645 to 0.721 on FastMRI, and shows comparable improvements on HCP. The IDR module plays a key role in enhancing perceptual and structural quality (e.g., LPIPS drops and SSIM improves), while the VCR module further enforces volumetric smoothness, reflected in higher NCC values. These results validate the complementary contributions of each module and the generalizability of PR-INR across different datasets and acceleration regimes.
2025PR-INR proposedPSNR28.9 dBacceleration=4×From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction
Source quote
L563: {Table~\ref{tab:motion} shows that our PR-INR outperforms state-of-the-art MRI reconstruction methods under both 4× and 8× acceleration on the fastMRI and HCP1200 datasets.} The model maintains superior image quality and structural consistency despite reduced sampling, indicating its capacity to restore high-frequency details and suppress undersampling artifacts. It achieves the highest PSNR (28.9/26.4 dB on fastMRI, 26.4/24.0 dB on HCP1200) and SSIM (0.887/0.721 on fastMRI, 0.895/0.849 on HCP1200), indicating superior reconstruction quality and perceptual fidelity. Fig.~\ref{fig4} (c) and (d) further demonstrate the advantages of PR-INR in visual quality. Compared to baseline models, our method reconstructs sharper anatomical boundaries and suppresses noise and artifacts. The zoomed-in regions especially highlight its ability to retain fine-grained features and maintain consistency with ground truth images.
2025PR-INR proposedPSNR26.4 dBacceleration=8×From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction
Source quote
L563: {Table~\ref{tab:motion} shows that our PR-INR outperforms state-of-the-art MRI reconstruction methods under both 4× and 8× acceleration on the fastMRI and HCP1200 datasets.} The model maintains superior image quality and structural consistency despite reduced sampling, indicating its capacity to restore high-frequency details and suppress undersampling artifacts. It achieves the highest PSNR (28.9/26.4 dB on fastMRI, 26.4/24.0 dB on HCP1200) and SSIM (0.887/0.721 on fastMRI, 0.895/0.849 on HCP1200), indicating superior reconstruction quality and perceptual fidelity. Fig.~\ref{fig4} (c) and (d) further demonstrate the advantages of PR-INR in visual quality. Compared to baseline models, our method reconstructs sharper anatomical boundaries and suppresses noise and artifacts. The zoomed-in regions especially highlight its ability to retain fine-grained features and maintain consistency with ground truth images.
2025Interleaved (self-supervised loss added during training) proposedPSNR31.55split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brainBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L283: Interleaved │ 31.55 │ .7910
2025Interleaved (self-supervised loss added during training) proposedSSIM.7910split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brainBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L283: Interleaved │ 31.55 │ .7910
2025DEAL proposedPSNR36.59split: test · coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32
2025DEAL proposedPSNR36.21split: test · coils=multi-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=8-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32
2025RFJS proposedPSNR (↑)25.85ACS=2% · coils=multi-coil · anatomy=knee · contrast=PDFS with PD · acceleration_factor=16Inference-Time Search Using Side Information for Diffusion-Based Image Reconstruction
Source quote
L1040: RFJS │ 25.85 │ 0.801 │ 0.375 │ 0.457
2025SelfDB proposedNRMSE0.108split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L137: SelfDB │ 0.108 │ 0.882 │ 0.036
2025SelfDB proposedSSIM0.882split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L137: SelfDB │ 0.108 │ 0.882 │ 0.036
2025SelfDB proposedLPIPS0.036split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L137: SelfDB │ 0.108 │ 0.882 │ 0.036
2025C-MSM proposed non-standard slicePSNR32.7split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L179: C\text{-}MSM │ \hlblue{32.7} │ 0.853 │ \hlgreen{0.144} [2pt] \cdashline{1-5} [2pt]
2025C-MSM proposed non-standard slicePSNR28.8split: test · acs-lines=20 · acceleration=×8 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L187: C\text{-}MSM │ \hlgreen{28.8} │ \hlblue{0.760} │ 0.265
2025C-MSM proposed non-standard sliceLPIPS0.144split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L179: C\text{-}MSM │ \hlblue{32.7} │ 0.853 │ \hlgreen{0.144} [2pt] \cdashline{1-5} [2pt]
2025GTF²M (ours; unsupervised prior-learning method) proposedNFEs20coil=single-coil · sampling=random-uniform · acceleration=4x and 8xUnsupervised Accelerated MRI Reconstruction via Ground-Truth-Free Flow Matching
Source quote
L366: Ours │ \magenta{0.801±0.073} │ \magenta{0.688±0.095} │ \magenta{31.64±2.95} │ \magenta{27.95±2.64} │ 20
2025HiFi-MambaV2 (P1) proposedSSIM0.855Equispaced sampling; acceleration factor ×4HiFi-MambaV2: Hierarchical Shared-Routed MoE for High-Fidelity MRI Reconstruction
Source quote
L295: On fastMRI, V2(P1) attains 34.86\,dB/0.855 SSIM at 4× and 31.89\,dB/0.764 SSIM at 8×, outperforming LMO by +0.37\,dB/+0.011 and +0.79\,dB/+0.020, respectively.
2025HiFi-MambaV2 (P1) proposedSSIM0.764Equispaced sampling; acceleration factor ×8HiFi-MambaV2: Hierarchical Shared-Routed MoE for High-Fidelity MRI Reconstruction
Source quote
L295: On fastMRI, V2(P1) attains 34.86\,dB/0.855 SSIM at 4× and 31.89\,dB/0.764 SSIM at 8×, outperforming LMO by +0.37\,dB/+0.011 and +0.79\,dB/+0.020, respectively.
2025MFoE proposedPSNR35.40split: test · noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4Multivariate Fields of Experts
Source quote
L327: MFoE │ 35.40 │ 34.21 │ 30.26 │ 31.20
2025Ours (uCMS + IrR) proposedPSNR27.97scale-factor=4× · reconstruction=2D slice-basedDecoupling Multi-Contrast Super-Resolution: Pairing Unpaired Synthesis with Implicit Representations
Source quote
L248: 27.97
2025HiFi-Mamba (P1) proposed non-standard slicePSNR34.85 dBsubset=PDFS single-coil knee · patch-size=1 · undersampling=equispaced 1D Cartesian · acceleration-factor=4HiFi-Mamba: Dual-Stream 𝒲 -Laplacian Enhanced Mamba for High-Fidelity MRI Reconstruction
Source quote
L285: The finer-grained variant HiFi-Mamba (P1), with a patch size of 1, further improves reconstruction performance, establishing a new state-of-the-art. Specifically, it achieves 34.85 / 31.81 dB PSNR and 0.855 / 0.762 SSIM on fastMRI (\text{AF}=4 / 8), with corresponding NMSE of 0.010 / 0.020. On CC359, it achieves 36.93 dB PSNR and 0.942 SSIM at \text{AF}=4, and maintains robust performance at \text{AF}=8, reaching 28.49 dB PSNR, 0.810 SSIM, and 0.026 NMSE, consistently surpassing prior state-of-the-art methods across all metrics.
2025HiFi-Mamba (P1) proposed non-standard slicePSNR31.81 dBsubset=PDFS single-coil knee · patch-size=1 · undersampling=equispaced 1D Cartesian · acceleration-factor=8HiFi-Mamba: Dual-Stream 𝒲 -Laplacian Enhanced Mamba for High-Fidelity MRI Reconstruction
Source quote
L285: The finer-grained variant HiFi-Mamba (P1), with a patch size of 1, further improves reconstruction performance, establishing a new state-of-the-art. Specifically, it achieves 34.85 / 31.81 dB PSNR and 0.855 / 0.762 SSIM on fastMRI (\text{AF}=4 / 8), with corresponding NMSE of 0.010 / 0.020. On CC359, it achieves 36.93 dB PSNR and 0.942 SSIM at \text{AF}=4, and maintains robust performance at \text{AF}=8, reaching 28.49 dB PSNR, 0.810 SSIM, and 0.026 NMSE, consistently surpassing prior state-of-the-art methods across all metrics.
2025HiFi-Mamba (P2) proposedPSNR31.38 dBGPU=NVIDIA A100 · FLOPs=67.87G · patch-size=2 · resolution=320×320 · acceleration-factor=8HiFi-Mamba: Dual-Stream 𝒲 -Laplacian Enhanced Mamba for High-Fidelity MRI Reconstruction
Source quote
L302: HiFi-Mamba (P2) achieves 31.38\,dB PSNR and 0.758 SSIM with only 67.87G FLOPs—substantially lower than all competing models, while matching or surpassing heavier attention-based architectures such as ReconFormer and FpsFormer.
2025Proposed BED procedure proposedPSNR16.0957subset=brain · iteration=1 · k-space-sampled=3.3659%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L210: 1 │ 16.0957 │ 0.7890 │ 3.3659
2025Proposed BED procedure proposedSSIM0.7890subset=brain · iteration=1 · k-space-sampled=3.3659%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L210: 1 │ 16.0957 │ 0.7890 │ 3.3659
2025Proposed BED procedure proposedPSNR20.6784subset=brain · iteration=9 · k-space-sampled=15.6789%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L214: 9 │ 20.6784 │ 0.9104 │ 15.6789
2025Proposed BED procedure proposedSSIM0.9104subset=brain · iteration=9 · k-space-sampled=15.6789%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L214: 9 │ 20.6784 │ 0.9104 │ 15.6789
2024Nila (Nila-DC) proposedPSNR37.08split: val · noise=none · acceleration=6×Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRI
Source quote
L124: Nila (ours) │ \textcolor{red}{37.08} │ \textcolor{red}{95.74} │ \textcolor{red}{34.82} │ \textcolor{red}{94.21} │ \textcolor{red}{36.10} │ \textcolor{red}{94.34} │ \textcolor{red}{33.54} │ \textcolor{red}{91.55} │ \textcolor{red}{30.23} │ \textcolor{red}{91.59} │ \textcolor{red}{29.86} │ \textcolor{red}{90.06}
2024Nila (Nila-DC) proposedPSNR31.86split: val · noise=Gaussian σ=0.1 · acceleration=6×Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRI
Source quote
L145: Nila (ours) │ \textcolor{red}{34.98} │ \textcolor{red}{93.96} │ \textcolor{red}{33.56} │ \textcolor{red}{92.49} │ \textcolor{red}{31.86} │ \textcolor{red}{90.38} │ \textcolor{red}{34.11} │ \textcolor{red}{91.53} │ \textcolor{red}{32.80} │ \textcolor{red}{89.59} │ \textcolor{red}{31.25} │ \textcolor{red}{87.15}
2024IR-FRestormerF proposedSSIM0.9427split: test · coil=multi-coil · anatomy=brain · ensemble=flip · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L265: 0.9427
2024aSeqDIP proposedPSNR34.08split: test · undersampling=4× · averaged-scans=20Image Reconstruction Via Autoencoding Sequential Deep Image Prior
Source quote
L533: 34.08
2024Policy Classifier proposedAUC0.789sample_rate=7% · center_fraction=0.01The MRI Scanner as a Diagnostic: Image-less Active Sampling
Source quote
L183: 0.717 │ 0.789 │ 0.785 │ 0.784 │ 0.775 │ 0.794 │ 0.752 │ 0.755 │ 0.739 │ 0.742 │ 0.741 │ 0.743
2024Policy Classifier proposedAUC0.794sample_rate=25% · center_fraction=0.01The MRI Scanner as a Diagnostic: Image-less Active Sampling
Source quote
L183: 0.717 │ 0.789 │ 0.785 │ 0.784 │ 0.775 │ 0.794 │ 0.752 │ 0.755 │ 0.739 │ 0.742 │ 0.741 │ 0.743
2024DiffMSR proposedDiffusion iteration steps4 stepsThe FastMRI comparison uses the experimental settings referenced in the caption; the pa…Rethinking Diffusion Model for Multi-Contrast MRI Super-Resolution
Source quote
L10: \caption{Comparison with DM-based MRI reconstruction methods on FastMRI dataset. Note that the experimental settings used by these methods are the same as those in Sec. \ref{exper}. As can be seen, our method has the best reconstruction metric and it only requires 4 iteration steps. Note that DiffuseRecon \cite{peng2022towards}, MC-DDPM \cite{xie2022measurement}, Score-MRI \cite{chung2022score}, and AdaDiff \cite{gungor2023adaptive} are employed for single-contrast SR (SCSR) reconstruction. DisC-Diff \cite{mao2023disc} is specifically designed for multi-contrast SR (MCSR) reconstruction.}
2024ADS proposedSSIM91.26split: test · resolution=128×128 · acceleration=4× · sampling-fraction=25%Active Diffusion Subsampling
Source quote
L251: While ADS appears to outperform fixed-mask baselines on MNIST, CelebA, and fastMRI, it is interesting to note that the relative improvement offered by ADS is less pronounced in the case of fastMRI. For line-based image subsampling on MNIST with 25% samples, ADS achieves a 50% reduction in reconstruction error versus a fixed-mask approach (MAE = 0.019 vs 0.037), whereas with line-based \kappa-space subsampling for fastMRI with 25% samples, ADS achieves only a 12% relative improvement (SSIM = 91.26 vs 90.13). We find that the size of this performance gap between fixed and active mask design strategies can be explained by examining the distribution of masks designed by ADS on each task (See Appendix \ref{appendix:mask-distributions}). Indeed, the masks designed for fastMRI are very similar, whereas those designed for MNIST typically differ depending on the sample. When mask designs are similar, then fixed masks will perform similarly to actively designed masks. This is in part a feature of the data distribution -- for example, most information in \kappa-space is contained in the center, at lower frequencies. Tasks in which one might expect significantly better performance from ADS are therefore those in which optimal masks will be highly sample-dependent.
2024SPGD Jittering proposed non-standard slicePSNR27.56evaluation=adversarial attack · acceleration=4×SGD Jittering: A Training Strategy for Robust and Accurate Model-Based Architectures
Source quote
L421: PSNR / SSIM │ fastMRI │ Adv. Attack │ Tumor Cell MSE training │ 27.93 / 0.582 │ 22.82 / 0.179 │ 29.39 / 0.771 AT │ 27.20 / 0.533 │ 26.78 / 0.518 │ 27.13 / 0.560 Input Jittering │ 24.88 / 0.299 │ 24.44 / 0.297 │ 25.85 / 0.478 SPGD Jittering │ 28.15 / 0.597 │ 27.56 / 0.577 │ 29.762 / 0.777
2024Deform-Mamba (Our) proposedPSNR32.11split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965
2024Deform-Mamba (Our) proposedSSIM0.7194split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965
2024FasterFC-U-Net proposedPSNR31.87subset=knee, single-coil · sampling=random Cartesian · acceleration=4Image Reconstruction for Accelerated MR Scan With Faster Fourier Convolutional Neural Networks
Source quote
L1185: 31.87
2024FasterFC-E2E-VarNet proposedPSNR39.05subset=knee, multi-coil · cascades=4 · sampling=random Cartesian · acceleration=4Image Reconstruction for Accelerated MR Scan With Faster Fourier Convolutional Neural Networks
Source quote
L1227: 0.0059 39.05 0.9165
2024Self-Guided DIP (Generalized) proposedAverage reconstruction PSNR31.77 dBsplit: test · anatomy=knee · variant=Generalized · acceleration=4x · average-images=15Analysis of Deep Image Prior and Exploiting Self-Guidance for Image Reconstruction
Source quote
L627: 31.77
2024DAPS proposedPSNR31.48subset=knee · resolution=320x320 · acceleration=4x · diffusion-model=EDMImproving Diffusion Inverse Problem Solving with Decoupled Noise Annealing
Source quote
L199: DAPS │ 31.48 │ 0.762 │ 1.57 │ 29.01 │ 0.681 │ 1.28
2024DAPS proposedPSNR29.01subset=knee · resolution=320x320 · acceleration=8x · diffusion-model=EDMImproving Diffusion Inverse Problem Solving with Decoupled Noise Annealing
Source quote
L199: DAPS │ 31.48 │ 0.762 │ 1.57 │ 29.01 │ 0.681 │ 1.28
2024HQS (Cheb preconditioner) proposedPSNR34.521acceleration-factor=4Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI Reconstruction
Source quote
L185: HQS │ 34.521 │ 33.251 │ 0.917 │ 0.902
2024HQS (Cheb preconditioner) proposedPSNR33.251acceleration-factor=16Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI Reconstruction
Source quote
L185: HQS │ 34.521 │ 33.251 │ 0.917 │ 0.902
2024HQS (Cheb preconditioner) proposedSSIM0.902acceleration-factor=16Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI Reconstruction
Source quote
L185: HQS │ 34.521 │ 33.251 │ 0.917 │ 0.902
2024SAFI proposedPSNR36.43split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=4-fold · coil-setting=single-coil · patch-resolution=320×320Iteratively Refined Image Reconstruction with Learned Attentive Regularizers
Source quote
L790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860
2024SAFI proposedPSNR36.06split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=8-fold · coil-setting=multi-coil · patch-resolution=320×320Iteratively Refined Image Reconstruction with Learned Attentive Regularizers
Source quote
L790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860
2024TC-KANRecon proposedPSNR30.50acceleration-factor=4TC-KANRecon: High-Quality and Accelerated MRI Reconstruction via Adaptive KAN Mechanisms and Intelligent Feature Scaling
Source quote
L209: TC-KANRecon (Ours) │ 30.50 │ 29.16 │ 27.93 │ 26.83 │ 0.817 │ 0.691 │ 0.624 │ 0.593 │ 0.0211 │ 0.0273 │ 0.0309 │ 0.0371
2024TC-KANRecon proposedSSIM0.817acceleration-factor=4TC-KANRecon: High-Quality and Accelerated MRI Reconstruction via Adaptive KAN Mechanisms and Intelligent Feature Scaling
Source quote
L209: TC-KANRecon (Ours) │ 30.50 │ 29.16 │ 27.93 │ 26.83 │ 0.817 │ 0.691 │ 0.624 │ 0.593 │ 0.0211 │ 0.0273 │ 0.0309 │ 0.0371
2024TC-KANRecon proposedNMSE0.0211acceleration-factor=4TC-KANRecon: High-Quality and Accelerated MRI Reconstruction via Adaptive KAN Mechanisms and Intelligent Feature Scaling
Source quote
L209: TC-KANRecon (Ours) │ 30.50 │ 29.16 │ 27.93 │ 26.83 │ 0.817 │ 0.691 │ 0.624 │ 0.593 │ 0.0211 │ 0.0273 │ 0.0309 │ 0.0371
2023RED-diff proposedPSNR37.1 dBsplit: val · coil=multi-coil · subset=6 validation volumes · undersampling=1D equispaced, R=4A Variational Perspective on Solving Inverse Problems with Diffusion Models
Source quote
L482: RED-diff │ 37.1 │ 33.2 │ 32.7 │ 0.114
2023RGFL proposed non-standard sliceStd. Dev.9.73E-7split: val · speedup=4×On the Quantification of Image Reconstruction Uncertainty without Training Data
Source quote
L210: Std. Dev. \downarrow │ 8.87E-5 │ 1.21E-5 │ 8.82E-6 │ 6.90E-6 │ {\bf 9.73E-7}
2023RGFL proposed non-standard sliceAbs. Error1.78E-6speedup=4×On the Quantification of Image Reconstruction Uncertainty without Training Data
Source quote
L211: Abs. Error \downarrow │ 8.72E-5 │ 3.31E-5 │ 6.91E-6 │ 1.83E-6 │ {\bf 1.78E-6}
2023McASSR (Ours; rectangle window 4×16/16×4) proposedPSNR32.52 dBsplit: test · scale=4x in-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PDRethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L483: 32.52
2023McASSR (Ours; rectangle window 4×16/16×4) proposedPSNR28.76 dBsplit: test · scale=8x out-of-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PDRethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L487: 28.76
2023U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard sliceSSIM0.902split: test · subset=PDFS knee · test-acceleration=4-fold · training-acceleration=2-, 4-, 8-, and 16-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912
2023U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard sliceSSIM0.912split: test · subset=PDFS knee · test-acceleration=3-fold · training-acceleration=2-, 4-, 8-, and 16-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912
2023CDiffMR-LogSR proposedInference Time ↓3.030anatomy=knee · hardware=NVIDIA RTX 3090 · acceleration-factor=8×CDiffMR: Can We Replace the Gaussian Noise with K-Space Undersampling for Fast MRI?
Source quote
L207: CDiffMR-LogSR │ 0.744 (0.107) │ 27.26 (2.52) │ 0.236 (0.041) │ 3.030
2023JSMoCo (R=2) proposed non-standard sliceNRMSE0.0093motion=rotation ±2°, translation ±3 pixels · sequence=T2-weighted brain · acceleration=R=2JSMoCo: Joint Coil Sensitivity and Motion Correction in Parallel MRI with a Self-Calibrating Score-Based Diffusion Model
Source quote
L384: Ours ( R = 2) │ 0.0093 │ 0.0093 │ 0.0091 │ 0.0099
2023JSMoCo (R=4.8) proposed non-standard sliceNRMSE0.0101motion=rotation ±2°, translation ±3 pixels · sequence=T2-weighted brain · acceleration=R=4.8JSMoCo: Joint Coil Sensitivity and Motion Correction in Parallel MRI with a Self-Calibrating Score-Based Diffusion Model
Source quote
L386: Ours (R = 4.8) │ 0.0101 │ 0.0111 │ 0.0110 │ 0.0107
2023APMC-PnP proposedPSNR32.70 dBsplit: test · acceleration=8×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1750: APMC-PnP (ours) │ 32.70 │ 36.03
2023APMC-PnP proposedPSNR36.03 dBsplit: test · acceleration=4×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1750: APMC-PnP (ours) │ 32.70 │ 36.03
2023Fed-PMG proposed#Info.cost46.88 Msetting=with clustering · measurement=one communication round · field-strength=1.5TFederated Pseudo Modality Generation for Incomplete Multi-Modal MRI Reconstruction
Source quote
L385: Fed-PMG │ 7.40 │ 46.88 │ \Omega(\varphi + K \beta)
2023Proposed joint non-linear inversion algorithm with diffusion prior proposedPSNR34.34split: val · subset=8% ACL; 15 central slices · contrast=PD · sampling=4-fold Cartesian; swapped phase-encoding direction · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L304: Cartesian\tnote{*} │ 4 │ 30.37 │ 28.65 │ 32.43 │ 30.88 │ 23.89 │ 29.68 │ 34.34 │ 32.88
2023Proposed joint non-linear inversion algorithm with diffusion prior proposedPSNR31.55split: val · subset=15 central slices · contrast=PDFS · sampling=4-fold Gaussian · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L305: Gaussian │ 4 │ 30.24 │ 27.68 │ 30.91 │ 30.90 │ 22.36 │ 27.35 │ 31.01 │ 31.55
2023Proposed joint non-linear inversion algorithm with diffusion prior proposedPSNR31.78split: val · subset=15 central slices · contrast=PDFS · sampling=radial; 45 spokes; 11-fold acceleration · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L306: Radial │ 11 │ 27.93 │ 26.70 │ 30.66 │ 30.70 │ 19.97 │ 25.55 │ 32.18 │ 31.78
2023Fed-CRFD proposedPSNR35.35 dBMain comparison; PSNR averaged over three independent trials. The passage mentions β=10…Cross-Modal Vertical Federated Learning for MRI Reconstruction
Source quote
L289: We report the MRI reconstruction performances on two datasets in Table \ref{tab1} under different settings (i.e., \beta = 10% and \beta = 2%). For FL-MRCM and FedMRI, we adopt the settings of the original papers. To alleviate the influence caused by random initialization, the average PSNR, SSIM scores and standard derivation of three independent trials are calculated for the comparing methods and our Fed-CRFD. Additionally, to measure the statistical significance of performance improvements, we conduct the paired t-test for Fed-CRFD and each baseline, and report the p-value as well. As seen, the FL methods significantly outperform Solo, which demonstrates the effectiveness of FL in leveraging multiple clients to obtain a robust global model. Compared to FedAvg, the FL-MRCM achieves almost the same PSNR and even lower SSIM scores. Such an experimental result shows that FL-MRCN cannot tackle the domain shift problem from different modalities. Due to learning the specific information of clients, FedMRI can mitigate the modal difference to some extent compared with FedAvg. Besides, the previous horizontal FL frameworks, i.e., FL-MRCM and FedMRI, have not considered the valuable information of vertical samples. In contrast, thanks to the novel design of our method, our method can effectively address the problem, which significantly improves the PSNR scores from 33.30 dB to 35.35 dB on the fastMRI dataset and from 29.86 dB to 30.95 dB on our private dataset, respectively. Furthermore, our Fed-CRFD is verified to achieve the significant improvement compared to FL-MRCM and FedMRI, i.e., the corresponding p-value < 0.05, and the comparable performance to the centralized model on our private dataset, which show the superiority of our method.
2022SwinMR (PI) proposedFréchet inception distance (FID)35.23mask=Gaussian 1D 10%Swin transformer for fast MRI
Source quote
L415: G1D10% │ 35.23 │ 169.83 │ 325.99
2022TITLE (Transformer Involved Trajectory LEarning) proposedphase selection time9 mscoil=single-coil · anatomy=kneeActive Phase-Encode Selection for Slice-Specific Fast MR Scanning Using a Transformer-Based Deep Reinforcement Learning Framework
Source quote
L830: 9
2022TITLE proposedaveraged SSIM0.6745coil=single-coil · anatomy=knee · reconstruction=learning-free IFTActive Phase-Encode Selection for Slice-Specific Fast MR Scanning Using a Transformer-Based Deep Reinforcement Learning Framework
Source quote
L898: The top part of Table 2 gives the performances of different methods where the images are reconstructed from the selected phases (corresponding incomplete K-space matrices) by learning-free IFT. The averaged SSIM of Random, Zhang, Pineda, and proposed TITLE methods is 0.6203, 0.6315, 0.6411, and 0.6745, respectively. Figure 5 (a) shows several examples of reconstructed images. The proposed method achieves the largest SSIM. SSIM is the most important criterion because of its consistence with eyes of human being. The averaged PSNR of Random, Zhang, Pineda, and TITLE methods is 27.10, 27.55,
2022TITLE proposedSSIM0.8163coil=single-coil · anatomy=knee · reconstruction=UNetActive Phase-Encode Selection for Slice-Specific Fast MR Scanning Using a Transformer-Based Deep Reinforcement Learning Framework
Source quote
L905: NMSE when the UNets converge are given in the bottom part of Table 2. Specifically, the SSIM of the Radom, Zhang, Pineda, and the proposed methods are 0.7962, 0.8020, 0.8113, and 0.8163, respectively. The proposed method achieves the largest SSIM.
2022CRR-NN proposedPSNR40.95split: test · coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-foldA Neural-Network-Based Convex Regularizer for Inverse Problems
Source quote
L794: CRR-NN │ {\bf 40.95} │ 38.91 │ {\bf 0.961} │ 0.934 │ 33.99 │ 33.75 │ 0.880 │ 0.831
2022LLS (\lambda=10 (-6)) proposedPSNR31.54split: test · mask=acceleration=4, center_fraction=0.08 · coils=single-coil · lambda=1e-6 · noise_sigma=0.01 · test_images=99Improving Lipschitz-Constrained Neural Networks by Learning Activation Functions
Source quote
L625: LLS │ 31.54 │ 0.7924 │ 28.04 │ 0.7108
2022LLS (\lambda=10 (-6)) proposedPSNR38.68mask=Cartesian, acceleration=4, center_fraction=0.08 · coils=15 · lambda=1e-6 · subset=PD · noise_sigma=0.002Improving Lipschitz-Constrained Neural Networks by Learning Activation Functions
Source quote
L639: LLS │ 38.68 │ 37.96 │ 0.943 │ 0.924 │ 32.75 │ 33.61 │ 0.859 │ 0.835
2022K-Space Transformer proposedPSNR27.80sampling=uniform-1d · acceleration=5xK-Space Transformer for Undersampled MRI Reconstruction
Source quote
L271: Ours │ \multicolumn{1}{c|}{31.50} │ \multicolumn{1}{c|}{0.9528} │ \multicolumn{1}{c|}{36.32} │ 0.9848 │ \multicolumn{1}{c|}{27.80} │ \multicolumn{1}{c|}{0.7078} │ \multicolumn{1}{c|}{31.04} │ 0.8189
2022rcGAN (cGAN (Ours)) proposedgeneration time (4 samples)217 mssamples=4 · contrast=T2 brain · resolution=384×384 · acceleration=R=4A Regularized Conditional GAN for Posterior Sampling in Image Recovery Problems
Source quote
L1183: 3.8e-6 │ 217 ms
2022ReconFormer proposedPSNR0.3 dBacceleration-factor=8×ReconFormer: Accelerated MRI Reconstruction Using Recurrent Transformer
Source quote
L124: by 0.9 dB and 0.3 dB in 8× acceleration, respectively. While the fastMRI dataset is more challenging due to the acquisition quality, all reported improvements achieved by ReconFormer are statistically significant. We provide the detailed statistical significance test in the supplementary material.
2022Variable-acceleration VarNet (authors’ “Our VarNet”) proposedNMSE (×10³)1.55split: val · coil=multi-coil · anatomy=brain · acceleration=variableA Path Towards Clinical Adaptation of Accelerated MRI
Source quote
L290: Our VarNet │ 96.7± 0.02 │ 1.55 │ 43.3± 0.03
2022FedGIMP proposedPSNR28.4 dBsplit: test · coil=single-coil · train-test-operator-shift=3x VD to 6x UDFederated Learning of Generative Image Priors for MRI Reconstruction
Source quote
L420: \multirow{1}{*}{FedGIMP} │ 35.3 │ 96.2 │ 28.4 │ 82.7 │ 46.9 │ 99.3
2022FedGIMP proposedPSNR38.4 dBsplit: test · coil=multi-coil · test-acceleration=6xFederated Learning of Generative Image Priors for MRI Reconstruction
Source quote
L542: \multirow{2}{*}{FedGIMP} │ 6x │ 38.4 │ 94.5
2021DONet proposed non-standard slicePSNR32.780 dBsplit: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniformDONet: Dual-Octave Network for Fast MR Image Reconstruction
Source quote
L274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data.
2021DONet proposed non-standard sliceSSIM0.856split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniformDONet: Dual-Octave Network for Fast MR Image Reconstruction
Source quote
L274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data.
2021MINet proposedPSNR31.769 dBscale=2× · evaluation=average score · contrast-setting=HR T1WI auxiliary to restore LR T2WIMulti-Contrast MRI Super-Resolution via a Multi-Stage Integration Network
Source quote
L109: MINet │ {\color{red}31.769} │ {\color{red}0.709} │ {\color{red}29.819} │ {\color{red}0.601} │ {\color{red}40.549} │ {\color{red}0.983} │ {\color{red}35.032} │ {\color{red}0.948} │ {\color{red}37.997} │ {\color{red}0.980} │ {\color{red}34.219} │ {\color{red}0.956}
2021MINet proposedSSIM0.709scale=2× · evaluation=average score · contrast-setting=HR T1WI auxiliary to restore LR T2WIMulti-Contrast MRI Super-Resolution via a Multi-Stage Integration Network
Source quote
L109: MINet │ {\color{red}31.769} │ {\color{red}0.709} │ {\color{red}29.819} │ {\color{red}0.601} │ {\color{red}40.549} │ {\color{red}0.983} │ {\color{red}35.032} │ {\color{red}0.948} │ {\color{red}37.997} │ {\color{red}0.980} │ {\color{red}34.219} │ {\color{red}0.956}
2021Deep Equilibrium (Grad) proposedMean PSNR32.01split: test · roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8×Deep Equilibrium Architectures for Inverse Problems in Imaging
Source quote
L334: PSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38
2021Joint-ICNet proposedPSNR40.7split: test · reduction-factor=4Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L360: 40.7
2021Joint-ICNet proposedPSNR37.3split: test · reduction-factor=8Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L375: 37.3
2021Joint-ICNet proposedNRMSE0.0087split: test · reduction-factor=8Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L374: 0.0087
2021PDNet w DC proposedPSNR32.66split: val · coil=single-coil · coverage=both contrasts · trajectory=radial · acceleration=4Density Compensated Unrolled Networks for Non-Cartesian MRI Reconstruction
Source quote
L174: PDNet w DC │ 32.66 / 0.7327 │ 33.08 / 0.7534 │ 156k
2021PDNet w DC proposedSSIM0.7327split: val · coil=single-coil · coverage=both contrasts · trajectory=radial · acceleration=4Density Compensated Unrolled Networks for Non-Cartesian MRI Reconstruction
Source quote
L174: PDNet w DC │ 32.66 / 0.7327 │ 33.08 / 0.7534 │ 156k
2021TDV (stochastic) proposedPSNR ↑33.5acceleration=R=4 · coil-setting=single-coil · stochastic-draws=N=32Bayesian Uncertainty Estimation of Learned Variational MRI Reconstruction
Source quote
L379: TDV (stochastic) │ 33.5 │ 0.0269 │ 0.762 │ 30.4 │ 0.0412 │ 0.662 │ 9.95
2021TDV (stochastic) proposedPSNR ↑38.9coils=Q=15 · acceleration=R=4 · coil-setting=multi-coil · stochastic-draws=N=32 · coil-sensitivities=not usedBayesian Uncertainty Estimation of Learned Variational MRI Reconstruction
Source quote
L386: TDV (stochastic) │ 38.9 │ 0.0058 │ 0.919 │ 35.2 │ 0.0123 │ 0.867 │ 9.97
2021TDV (stochastic) proposedPSNR ↑35.2coils=Q=15 · acceleration=R=8 · coil-setting=multi-coil · stochastic-draws=N=32 · coil-sensitivities=not usedBayesian Uncertainty Estimation of Learned Variational MRI Reconstruction
Source quote
L386: TDV (stochastic) │ 38.9 │ 0.0058 │ 0.919 │ 35.2 │ 0.0123 │ 0.867 │ 9.97
2021MRAugment with E2E-VarNet proposedreconstruction SSIM0.9049subset=2% of training data · scanner-transfer=3T to 3TData augmentation for deep learning based accelerated MRI reconstruction with limited data
Source quote
L293: 3T \rightarrow 3T │ 0.8646 │ 0.9049
2021MRAugment with E2E-VarNet proposedreconstruction SSIM0.8913subset=2% of training data · scanner-transfer=1.5T to 3TData augmentation for deep learning based accelerated MRI reconstruction with limited data
Source quote
L295: 1.5T \rightarrow 3T │ 0.8174 │ 0.8913
2021A-DPS (proposed) proposedNMSE0.0342split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L293: 0.0342
2021A-DPS (proposed) proposedPSNR30.2split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L294: 30.2
2021A-DPS (proposed) proposedSSIM0.654split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L295: 0.654 different in that case. Whereas in the previous experiment
2020DeepPhaseCut proposedPSNR19.820 dBsplit: test · coil=single-coil · image-type=complex-valued knee images; magnitude metrics · resolution=64×64 · oversampling-ratio=4DeepPhaseCut: Deep Relaxation in Phase for Unsupervised Fourier Phase Retrieval
Source quote
L628: DeepPhaseCut │ 19.820 │ 0.399 │ 0.042
2020Proposed Co-VeGAN proposedPSNR34.593 dBsplit: test · noise=noise-free · undersampling=30% · representation=complex-valued · sampling-pattern=1D-GCo-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image Reconstruction
Source quote
L296: \rule{0pt}{9pt} Proposed │ 1.7M │ 34.593 / 0.7893 │ 34.416 / 0.7870 │ 33.804 / 0.7673
2020Proposed Co-VeGAN proposedmSSIM0.7893split: test · noise=noise-free · undersampling=30% · representation=complex-valued · sampling-pattern=1D-GCo-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image Reconstruction
Source quote
L296: \rule{0pt}{9pt} Proposed │ 1.7M │ 34.593 / 0.7893 │ 34.416 / 0.7870 │ 33.804 / 0.7673
2020ReconODE-LT-Euler proposedPSNR31.86split: val · subset=single-coil knee · undersampling=4xMRI Image Reconstruction via Learning Optimization Using Neural ODEs
Source quote
L141: ReconODE-LT-Euler │ 0.03M │ 31.86 │ 29.11 │ 0.7194 │ 0.6363
2020ReconODE-LT-Euler proposedSSIM0.7194split: val · subset=single-coil knee · undersampling=4xMRI Image Reconstruction via Learning Optimization Using Neural ODEs
Source quote
L141: ReconODE-LT-Euler │ 0.03M │ 31.86 │ 29.11 │ 0.7194 │ 0.6363
2020Proposed pixel-wise RL MRI reconstruction (Ours, with data consistency) proposed non-standard sliceNMSE0.14split: val · coil=single-coil · subset=first 1,000 validation images · masking=random 40%MRI Reconstruction with Interpretable Pixel-Wise Operations Using Reinforcement Learning
Source quote
L338: 0.14
2020Proposed pixel-wise RL MRI reconstruction (Ours, with data consistency) proposed non-standard slicePSNR30.3split: val · coil=single-coil · subset=first 1,000 validation images · masking=random 40%MRI Reconstruction with Interpretable Pixel-Wise Operations Using Reinforcement Learning
Source quote
L339: 30.3
2020Proposed pixel-wise RL MRI reconstruction (Ours, with data consistency) proposed non-standard sliceSSIM0.88split: val · coil=single-coil · subset=first 1,000 validation images · masking=random 40%MRI Reconstruction with Interpretable Pixel-Wise Operations Using Reinforcement Learning
Source quote
L340: 0.88 the images are of various sizes, we crop the 320x320 center region and then do the down-sampling. In addition, images are normalized and rescaled into range [0, 255].
2020IFR-Net proposedHFEN0.6119split: test · subset=50 knee images · channel=single · data-type=complex-valued · sampling-rate=25% · sampling-pattern=2D-randomIFR-Net: Iterative Feature Refinement Network for Compressed Sensing MRI
Source quote
L1102: 0.6119
2020Orientation adversary (Adversary) proposedAverage rank for visible banding (higher is better)2.83split: val · acceleration=4× · field-strength=1.5T · central-k-space-lines=16MRI Banding Removal via Adversarial Training
Source quote
L412: Adversary │ 1.09×10 (-11) │ 2.18×10 (-11) │ 2.83\tabularnewline
2020Orientation adversary (Adversary) proposed non-standard sliceAverage rank for retention of fine anatomical detail versus ground truth (higher is better)2.18split: val · acceleration=4× · field-strength=1.5T · central-k-space-lines=16MRI Banding Removal via Adversarial Training
Source quote
L432: Adversary │ 2.61 │ 8.82×10 (-4) │ 2.18\tabularnewline
2020Orientation adversary (Adversary) proposedReports of any banding present (yes/no)0.725 proportionsplit: val · acceleration=4× · field-strength=1.5T · central-k-space-lines=16MRI Banding Removal via Adversarial Training
Source quote
L454: 0.725 (0.62-0.82) │ 0.967 (0.92-1) │ 0.975 (0.90-0.99)\tabularnewline
2020PDS-ATM2 proposedrSNR21.00 dBsplit: test · coils=4 · subset=10 images · resolution=128×128 · acceleration=4 · measured-snr=15 dBAutotuning Plug-and-Play Algorithms for MRI
Source quote
L343: PDS-ATM2 │ 21.00 │ 0.805 │ 21.44 │ 0.817 │ 21.93 │ 0.833 │ 22.33 │ 0.850
2020PDS-ATM2 proposedrSNR22.33 dBsplit: test · coils=4 · subset=10 images · resolution=128×128 · acceleration=4 · measured-snr=23 dBAutotuning Plug-and-Play Algorithms for MRI
Source quote
L343: PDS-ATM2 │ 21.00 │ 0.805 │ 21.44 │ 0.817 │ 21.93 │ 0.833 │ 22.33 │ 0.850
2020PDS-ATM2 proposediterations to convergence<30 iterationssplit: test · coils=4 · resolution=128×128 · acceleration=4Autotuning Plug-and-Play Algorithms for MRI
Source quote
L316: There we see that PDS-ATM2 converges as fast as genie-tuned PDS (i.e., <30 iterations) and significantly faster than PDS-ATO.
2020E2E-VN proposedSSIM0.930split: test · anatomy=knee · acceleration=4×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L197: E2E-VN │ 0.930 │ 0.005 │ 40 │ 0.890 │ 0.009 │ 37
2020E2E-VN proposedSSIM0.890split: test · anatomy=knee · acceleration=8×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L197: E2E-VN │ 0.930 │ 0.005 │ 40 │ 0.890 │ 0.009 │ 37
2020E2E-VN proposedSSIM0.959split: test · anatomy=brain · acceleration=4×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L202: Brain │ E2E-VN │ 0.959 │ 0.004 │ 41 │ 0.943 │ 0.008 │ 38
2020E2E-VN proposedSSIM0.943split: test · anatomy=brain · acceleration=8×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L202: Brain │ E2E-VN │ 0.959 │ 0.004 │ 41 │ 0.943 │ 0.008 │ 38
2020OT-cycleGAN (Proposed) proposedPSNR28.7426 dBsplit: test · coil=single-coil · subset=ESC · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4xUnpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGAN
Source quote
L485: \ │ Proposed │ 28.7426 │ 0.6758 \multirow{8}*{Multi-Coil} │ \multirow{4}*{× 4} │ Input │ 28.0524 │ 0.7616
2020OT-cycleGAN (Proposed) proposedPSNR32.1812 dBsplit: test · coil=multi-coil (15-coil) · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4xUnpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGAN
Source quote
L488: \ │ Proposed │ 32.1812 │ 0.8300
2019Proposed self-supervised learning (SSL; U-net inverse operator) proposedPSNR22.86 dBsplit: val · acceleration=×8Self-supervised learning of inverse problem solvers in medical imaging
Source quote
L130: PSNR │ 13.74 │ N/A │ 22.86 │ 26.72
2019Proposed self-supervised learning (SSL; U-net inverse operator) proposedSSIM0.47split: val · acceleration=×8Self-supervised learning of inverse problem solvers in medical imaging
Source quote
L131: SSIM │ 0.40 │ N/A │ 0.47 │ 0.604
2019Offset 0 sampling proposedSSIM0.924split: val · sampling=Offset 0 · coil-setup=multi-coil · acceleration=4x · low-frequency-lines=16Offset Masking Improves Deep Learning based Accelerated MRI Reconstructions
Source quote
L261: knee MRI reconstruction, showing an improvement in SSIM from 0.924
2019Offset 1 sampling proposedSSIM0.926split: val · sampling=Offset 1 · coil-setup=multi-coil · acceleration=4x · low-frequency-lines=16Offset Masking Improves Deep Learning based Accelerated MRI Reconstructions
Source quote
L262: to 0.926.}
2019unpaired WGAN proposedSSIM0.822split: test · unpaired · training=7 input subjects, 6 disjoint label subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersamplingWasserstein GANs for MR Imaging: From Paired to Unpaired Training
Source quote
L217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831
2019WGAN+ℓ₁ proposedSSIM0.824split: test · paired · training=6 subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersamplingWasserstein GANs for MR Imaging: From Paired to Unpaired Training
Source quote
L217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831
2019PC-RNN (multi-coil) proposedPSNR39.0split: val · coil=multi-coil · acceleration=4xPyramid Convolutional RNN for MRI Reconstruction
Source quote
L134: Multi-coil │ PC-RNN │ 39.0 │ 36.5 │ 0.914 │ 0.884
2019PC-RNN (multi-coil) proposedPSNR36.5split: val · coil=multi-coil · acceleration=8xPyramid Convolutional RNN for MRI Reconstruction
Source quote
L134: Multi-coil │ PC-RNN │ 39.0 │ 36.5 │ 0.914 │ 0.884
2019PC-RNN (single-coil) proposedPSNR31.3split: val · coil=single-coil · acceleration=8xPyramid Convolutional RNN for MRI Reconstruction
Source quote
L131: Single-coil │ PC-RNN │ 32.8 │ 31.3 │ 0.743 │ 0.682
2018DeepALOHA proposedPSNR35.5181 dBcoil=single-coil · acceleration=R=3k-Space Deep Learning for Accelerated MRI
Source quote
L572: \ PSNR [dB] │ 31.0201 │ 33.3799 │ 35.5181