fastMRI
86 papers · 287 extracted observations · mri reconstruction · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CRR-NN SOTA frontier | 40.95 | 2023-01-01 | coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-fold · FastMRI knee PD test images; 2-fold Cartesian undersampling, measurement noise standa… | A Neural-Network-Based Convex Regularizer for Inverse ProblemsSource quoteCRR-NN │ {\bf 40.95} │ 38.91 │ {\bf 0.961} │ 0.934 │ 33.99 │ 33.75 │ 0.880 │ 0.831 |
| 2 | Joint-ICNet SOTA frontier (+3 variants) | 40.7 | 2021-01-01 | reduction-factor=4 · Table 2 model ablation; reduction factor R=4. Paper setup uses multi-coil k-space ret… | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quote40.7 |
| 3 | DEAL (+1 variant) | 36.59 | 2025-01-01 | coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-fold · 4-fold single-coil setup; centered 320×320 patches from 50 test images; additive whit… | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteDEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32 |
| 4 | SAFI (+1 variant) | 36.43 | 2024-07-01 | subset=50 test images · sequence=PD · resolution=320x320 · acceleration=4-fold · coil-setting=single-coil · patch-resolution=320×320 · PD knee images without fat suppression; denoising-trained model, with λ tuned on 10 v… | Iteratively Refined Image Reconstruction with Learned Attentive RegularizersSource quoteSAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860 |
| 5 | MFoE | 35.4 | 2025-08-01 | noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4 · PD data; acceleration factor 4 and center fraction 0.08; Gaussian measurement noise w… | Multivariate Fields of ExpertsSource quoteMFoE │ 35.40 │ 34.21 │ 30.26 │ 31.20 |
| 6 | aSeqDIP | 34.08 | 2024-01-01 | undersampling=4× · averaged-scans=20 · Average over 20 MRI scans from the fastMRI testing set at 4× undersampling; no labele… | Image Reconstruction Via Autoencoding Sequential Deep Image PriorSource quote34.08 |
| 7 | Deform-Mamba (Our) | 32.11 | 2024-07-01 | scale=4× · 4× upsampling; held-out test split (45 subjects); low-resolution inputs synthesized i… | Deform-Mamba Network for MRI Super-ResolutionSource quoteOur │ 32.11 │ 0.7194 │ 30.60 │ 0.8965 |
| 8 | Deep Equilibrium (Grad) | 32.01 | 2021-02-01 | roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8× · Test-set mean; 8× accelerated virtual single-coil Cartesian MRI with complex AWGN sta… | Deep Equilibrium Architectures for Inverse Problems in ImagingSource quotePSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38 |
| 9 | Interleaved (self-supervised loss added during training) | 31.55 | 2025-01-01 | method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brain · 6x-accelerated MRI; trained on the FastMRI brain dataset and tested on knees. | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteInterleaved │ 31.55 │ .7910 |
| 10 | LLS (\lambda=10 (-6)) | 31.54 | 2024-01-01 | mask=acceleration=4, center_fraction=0.08 · coils=single-coil · lambda=1e-6 · noise_sigma=0.01 · test_images=99 · PnP-FBS reconstruction; measurement noise \sigma-\mathbf n=0.01; mask (M_{\text{acc}}… | Improving Lipschitz-Constrained Neural Networks by Learning Activation FunctionsSource quoteLLS │ 31.54 │ 0.7924 │ 28.04 │ 0.7108 |
| 11 | A-DPS (proposed) | 30.2 | 2021-01-01 | resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 · Table 2: acceleration factor 8; scenario-30L (30 k-space lines closest to DC, with 16… | Active Deep Probabilistic SubsamplingSource quote30.2 |
| 12 | Distilled (on-policy privileged information distillation) (+2 variants) | 27.86 | 2026-05-01 | contrast=T1 · acceleration=R=32 · undersampling=Gaussian-VD · R=32; Gaussian-VD undersampling; T1 contrast. | Next-Acceleration-Scale Prediction for Autoregressive MRI ReconstructionSource quoteDistilled │ 27.86 │ 22.29 │ 24.08 │ 0.81 │ 0.70 │ 0.67 │ 0.148 │ 0.161 │ 0.162 |
Showing 144 of 144 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Distilled (on-policy privileged information distillation) proposed | PSNR | 27.86 | split: test · contrast=T1 · acceleration=R=32 · undersampling=Gaussian-VD | Next-Acceleration-Scale Prediction for Autoregressive MRI ReconstructionSource quoteL344: Distilled │ 27.86 │ 22.29 │ 24.08 │ 0.81 │ 0.70 │ 0.67 │ 0.148 │ 0.161 │ 0.162 |
| 2026 | Distilled (on-policy privileged information distillation) proposed | PSNR | 24.11 | split: test · contrast=T1 · acceleration=R=32 · undersampling=ES Cartesian-Y | Next-Acceleration-Scale Prediction for Autoregressive MRI ReconstructionSource quoteL354: Distilled │ 24.11 │ 18.42 │ 20.96 │ 0.74 │ 0.55 │ 0.57 │ 0.169 │ 0.230 │ 0.216 |
| 2026 | Distilled (on-policy privileged information distillation) proposed | PSNR | 26.00 | split: test · contrast=T1 · acceleration=R=32 · undersampling=Radial | Next-Acceleration-Scale Prediction for Autoregressive MRI ReconstructionSource quoteL359: Distilled │ 26.00 │ 20.51 │ 22.68 │ 0.78 │ 0.64 │ 0.63 │ 0.160 │ 0.196 │ 0.186 |
| 2026 | OCDI-Net proposed | PSNR | 41.88 | SMS=MB3R1 · subset=T2 · reconstruction=single-stage SMS unaliasing · image-representation=RSS magnitude | Back to Physics: Operator-Guided Generative Paths for SMS MRI ReconstructionSource quoteL619: OCDI-Net │ 41.88 │ 0.966 │ \boldsymbol{2.5× 10 (-3)} |
| 2026 | OCDI-Net proposed | SSIM | 0.966 | SMS=MB3R1 · subset=T2 · reconstruction=single-stage SMS unaliasing · image-representation=RSS magnitude | Back to Physics: Operator-Guided Generative Paths for SMS MRI ReconstructionSource quoteL619: OCDI-Net │ 41.88 │ 0.966 │ \boldsymbol{2.5× 10 (-3)} |
| 2026 | SGPnP-PGM (Decouple) proposed | PSNR | 32.54 | acceleration=4x · noise-levels=decoupled | Stochastic Generative Plug-and-Play PriorsSource quoteL753: \multicolumn{1}{c}{\hlgreen{32.91}} │ \multicolumn{1}{c}{31.44} │ \multicolumn{1}{c}{\hlgreen{33.32}} │ \multicolumn{1}{c}{30.20} │ \multicolumn{1}{c}{\hlgreen{32.54}} \\[+.95ex] |
| 2026 | EvoML proposed | SSIM | 0.9498 | split: test · supervised | Validation-Gated ML Pipeline Synthesis with Expert-Grounded Self-Evolving SkillsSource quoteL975: The margin is largest on the harder tasks, reaching 0.9498 |
| 2026 | GEO proposed | SSFD | 6.67 | anatomy=brain · acceleration=×8 | Anatomical Token Uncertainty for Transformer-Guided Active MRI AcquisitionSource quoteL104: GEO (Ours) │ Transformer │ 27.26 │ 0.6783 │ 0.0407 │ 2.96 │ 0.13 │ 6.67 |
| 2026 | GEO proposed | SSFD | 8.82 | anatomy=knee · acceleration=×16 | Anatomical Token Uncertainty for Transformer-Guided Active MRI AcquisitionSource quoteL96: GEO (Ours) │ Transformer │ 28.61 │ 0.5983 │ 0.0653 │ 4.11 │ 0.18 │ 8.82 |
| 2026 | PAS-Mamba proposed | PSNR | 32.46 | Radial mask, ×2 acceleration. | PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI ReconstructionSource quoteL241: Ours │ 32.46 │ 0.8838 │ 28.84 │ 0.8301 |
| 2026 | PAS-Mamba proposed | SSIM | 0.8838 | Radial mask, ×2 acceleration. | PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI ReconstructionSource quoteL241: Ours │ 32.46 │ 0.8838 │ 28.84 │ 0.8301 |
| 2026 | PAS-Mamba proposed | PSNR | 26.47 | Cartesian mask, ×4 acceleration. | PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI ReconstructionSource quoteL249: Ours │ 28.35 │ 0.7058 │ 26.47 │ 0.7081 |
| 2026 | PAS-Mamba proposed | SSIM | 0.7081 | Cartesian mask, ×4 acceleration. | PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI ReconstructionSource quoteL249: Ours │ 28.35 │ 0.7058 │ 26.47 │ 0.7081 |
| 2025 | SDUM proposed | PSNR | 42.6 dB | coils=multi-coil · anatomy=brain · acceleration=4× · unrolling-steps=6 | SDUM: A Scalable Deep Unrolled Model for Universal MRI ReconstructionSource quoteL403: SDUM (Ours) │ 0.979 │ \multicolumn{1}{c|}{42.6} │ 0.973 │ 40.8 |
| 2025 | PR-INR proposed | PSNR | 33.3 dB | motion-displacement=3% | From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI ReconstructionSource quoteL617: Table~\ref{tab:ablation_final} shows that the full configuration of our PR-INR framework consistently achieves the best performance across all undersampling settings on both the FastMRI and HCP 1200 datasets. At 3% and 5% displacement during acquisition, the complete model achieves strong gains over the baseline. For instance, PSNR/SSIM improves from 30.0/0.853 to 33.3/0.919 on FastMRI, and from 24.3/0.820 to 27.0/0.904 on HCP 1200 at 3%, with similar trends at 5%. Under 4x and 8x undersampling, PR-INR remains robust, consistently outperforming variants. At 8x, it improves PSNR from 23.9 to 26.4 and SSIM from 0.645 to 0.721 on FastMRI, and shows comparable improvements on HCP. The IDR module plays a key role in enhancing perceptual and structural quality (e.g., LPIPS drops and SSIM improves), while the VCR module further enforces volumetric smoothness, reflected in higher NCC values. These results validate the complementary contributions of each module and the generalizability of PR-INR across different datasets and acceleration regimes. |
| 2025 | PR-INR proposed | SSIM | 0.919 | motion-displacement=3% | From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI ReconstructionSource quoteL617: Table~\ref{tab:ablation_final} shows that the full configuration of our PR-INR framework consistently achieves the best performance across all undersampling settings on both the FastMRI and HCP 1200 datasets. At 3% and 5% displacement during acquisition, the complete model achieves strong gains over the baseline. For instance, PSNR/SSIM improves from 30.0/0.853 to 33.3/0.919 on FastMRI, and from 24.3/0.820 to 27.0/0.904 on HCP 1200 at 3%, with similar trends at 5%. Under 4x and 8x undersampling, PR-INR remains robust, consistently outperforming variants. At 8x, it improves PSNR from 23.9 to 26.4 and SSIM from 0.645 to 0.721 on FastMRI, and shows comparable improvements on HCP. The IDR module plays a key role in enhancing perceptual and structural quality (e.g., LPIPS drops and SSIM improves), while the VCR module further enforces volumetric smoothness, reflected in higher NCC values. These results validate the complementary contributions of each module and the generalizability of PR-INR across different datasets and acceleration regimes. |
| 2025 | PR-INR proposed | PSNR | 28.9 dB | acceleration=4× | From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI ReconstructionSource quoteL563: {Table~\ref{tab:motion} shows that our PR-INR outperforms state-of-the-art MRI reconstruction methods under both 4× and 8× acceleration on the fastMRI and HCP1200 datasets.} The model maintains superior image quality and structural consistency despite reduced sampling, indicating its capacity to restore high-frequency details and suppress undersampling artifacts. It achieves the highest PSNR (28.9/26.4 dB on fastMRI, 26.4/24.0 dB on HCP1200) and SSIM (0.887/0.721 on fastMRI, 0.895/0.849 on HCP1200), indicating superior reconstruction quality and perceptual fidelity. Fig.~\ref{fig4} (c) and (d) further demonstrate the advantages of PR-INR in visual quality. Compared to baseline models, our method reconstructs sharper anatomical boundaries and suppresses noise and artifacts. The zoomed-in regions especially highlight its ability to retain fine-grained features and maintain consistency with ground truth images. |
| 2025 | PR-INR proposed | PSNR | 26.4 dB | acceleration=8× | From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI ReconstructionSource quoteL563: {Table~\ref{tab:motion} shows that our PR-INR outperforms state-of-the-art MRI reconstruction methods under both 4× and 8× acceleration on the fastMRI and HCP1200 datasets.} The model maintains superior image quality and structural consistency despite reduced sampling, indicating its capacity to restore high-frequency details and suppress undersampling artifacts. It achieves the highest PSNR (28.9/26.4 dB on fastMRI, 26.4/24.0 dB on HCP1200) and SSIM (0.887/0.721 on fastMRI, 0.895/0.849 on HCP1200), indicating superior reconstruction quality and perceptual fidelity. Fig.~\ref{fig4} (c) and (d) further demonstrate the advantages of PR-INR in visual quality. Compared to baseline models, our method reconstructs sharper anatomical boundaries and suppresses noise and artifacts. The zoomed-in regions especially highlight its ability to retain fine-grained features and maintain consistency with ground truth images. |
| 2025 | Interleaved (self-supervised loss added during training) proposed | PSNR | 31.55 | split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brain | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteL283: Interleaved │ 31.55 │ .7910 |
| 2025 | Interleaved (self-supervised loss added during training) proposed | SSIM | .7910 | split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brain | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteL283: Interleaved │ 31.55 │ .7910 |
| 2025 | DEAL proposed | PSNR | 36.59 | split: test · coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-fold | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteL355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32 |
| 2025 | DEAL proposed | PSNR | 36.21 | split: test · coils=multi-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=8-fold | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteL355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32 |
| 2025 | RFJS proposed | PSNR (↑) | 25.85 | ACS=2% · coils=multi-coil · anatomy=knee · contrast=PDFS with PD · acceleration_factor=16 | Inference-Time Search Using Side Information for Diffusion-Based Image ReconstructionSource quoteL1040: RFJS │ 25.85 │ 0.801 │ 0.375 │ 0.457 |
| 2025 | SelfDB proposed | NRMSE | 0.108 | split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25% | A Self-Supervised Diffusion Bridge for MRI ReconstructionSource quoteL137: SelfDB │ 0.108 │ 0.882 │ 0.036 |
| 2025 | SelfDB proposed | SSIM | 0.882 | split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25% | A Self-Supervised Diffusion Bridge for MRI ReconstructionSource quoteL137: SelfDB │ 0.108 │ 0.882 │ 0.036 |
| 2025 | SelfDB proposed | LPIPS | 0.036 | split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25% | A Self-Supervised Diffusion Bridge for MRI ReconstructionSource quoteL137: SelfDB │ 0.108 │ 0.882 │ 0.036 |
| 2025 | C-MSM proposed non-standard slice | PSNR | 32.7 | split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01 | Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity EstimationSource quoteL179: C\text{-}MSM │ \hlblue{32.7} │ 0.853 │ \hlgreen{0.144} [2pt] \cdashline{1-5} [2pt] |
| 2025 | C-MSM proposed non-standard slice | PSNR | 28.8 | split: test · acs-lines=20 · acceleration=×8 · measurement-noise=σ=0.01 | Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity EstimationSource quoteL187: C\text{-}MSM │ \hlgreen{28.8} │ \hlblue{0.760} │ 0.265 |
| 2025 | C-MSM proposed non-standard slice | LPIPS | 0.144 | split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01 | Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity EstimationSource quoteL179: C\text{-}MSM │ \hlblue{32.7} │ 0.853 │ \hlgreen{0.144} [2pt] \cdashline{1-5} [2pt] |
| 2025 | GTF²M (ours; unsupervised prior-learning method) proposed | NFEs | 20 | coil=single-coil · sampling=random-uniform · acceleration=4x and 8x | Unsupervised Accelerated MRI Reconstruction via Ground-Truth-Free Flow MatchingSource quoteL366: Ours │ \magenta{0.801±0.073} │ \magenta{0.688±0.095} │ \magenta{31.64±2.95} │ \magenta{27.95±2.64} │ 20 |
| 2025 | HiFi-MambaV2 (P1) proposed | SSIM | 0.855 | Equispaced sampling; acceleration factor ×4 | HiFi-MambaV2: Hierarchical Shared-Routed MoE for High-Fidelity MRI ReconstructionSource quoteL295: On fastMRI, V2(P1) attains 34.86\,dB/0.855 SSIM at 4× and 31.89\,dB/0.764 SSIM at 8×, outperforming LMO by +0.37\,dB/+0.011 and +0.79\,dB/+0.020, respectively. |
| 2025 | HiFi-MambaV2 (P1) proposed | SSIM | 0.764 | Equispaced sampling; acceleration factor ×8 | HiFi-MambaV2: Hierarchical Shared-Routed MoE for High-Fidelity MRI ReconstructionSource quoteL295: On fastMRI, V2(P1) attains 34.86\,dB/0.855 SSIM at 4× and 31.89\,dB/0.764 SSIM at 8×, outperforming LMO by +0.37\,dB/+0.011 and +0.79\,dB/+0.020, respectively. |
| 2025 | MFoE proposed | PSNR | 35.40 | split: test · noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4 | Multivariate Fields of ExpertsSource quoteL327: MFoE │ 35.40 │ 34.21 │ 30.26 │ 31.20 |
| 2025 | Ours (uCMS + IrR) proposed | PSNR | 27.97 | scale-factor=4× · reconstruction=2D slice-based | Decoupling Multi-Contrast Super-Resolution: Pairing Unpaired Synthesis with Implicit RepresentationsSource quoteL248: 27.97 |
| 2025 | HiFi-Mamba (P1) proposed non-standard slice | PSNR | 34.85 dB | subset=PDFS single-coil knee · patch-size=1 · undersampling=equispaced 1D Cartesian · acceleration-factor=4 | HiFi-Mamba: Dual-Stream 𝒲 -Laplacian Enhanced Mamba for High-Fidelity MRI ReconstructionSource quoteL285: The finer-grained variant HiFi-Mamba (P1), with a patch size of 1, further improves reconstruction performance, establishing a new state-of-the-art. Specifically, it achieves 34.85 / 31.81 dB PSNR and 0.855 / 0.762 SSIM on fastMRI (\text{AF}=4 / 8), with corresponding NMSE of 0.010 / 0.020. On CC359, it achieves 36.93 dB PSNR and 0.942 SSIM at \text{AF}=4, and maintains robust performance at \text{AF}=8, reaching 28.49 dB PSNR, 0.810 SSIM, and 0.026 NMSE, consistently surpassing prior state-of-the-art methods across all metrics. |
| 2025 | HiFi-Mamba (P1) proposed non-standard slice | PSNR | 31.81 dB | subset=PDFS single-coil knee · patch-size=1 · undersampling=equispaced 1D Cartesian · acceleration-factor=8 | HiFi-Mamba: Dual-Stream 𝒲 -Laplacian Enhanced Mamba for High-Fidelity MRI ReconstructionSource quoteL285: The finer-grained variant HiFi-Mamba (P1), with a patch size of 1, further improves reconstruction performance, establishing a new state-of-the-art. Specifically, it achieves 34.85 / 31.81 dB PSNR and 0.855 / 0.762 SSIM on fastMRI (\text{AF}=4 / 8), with corresponding NMSE of 0.010 / 0.020. On CC359, it achieves 36.93 dB PSNR and 0.942 SSIM at \text{AF}=4, and maintains robust performance at \text{AF}=8, reaching 28.49 dB PSNR, 0.810 SSIM, and 0.026 NMSE, consistently surpassing prior state-of-the-art methods across all metrics. |
| 2025 | HiFi-Mamba (P2) proposed | PSNR | 31.38 dB | GPU=NVIDIA A100 · FLOPs=67.87G · patch-size=2 · resolution=320×320 · acceleration-factor=8 | HiFi-Mamba: Dual-Stream 𝒲 -Laplacian Enhanced Mamba for High-Fidelity MRI ReconstructionSource quoteL302: HiFi-Mamba (P2) achieves 31.38\,dB PSNR and 0.758 SSIM with only 67.87G FLOPs—substantially lower than all competing models, while matching or surpassing heavier attention-based architectures such as ReconFormer and FpsFormer. |
| 2025 | Proposed BED procedure proposed | PSNR | 16.0957 | subset=brain · iteration=1 · k-space-sampled=3.3659% | Active MRI Acquisition with Diffusion Guided Bayesian Experimental DesignSource quoteL210: 1 │ 16.0957 │ 0.7890 │ 3.3659 |
| 2025 | Proposed BED procedure proposed | SSIM | 0.7890 | subset=brain · iteration=1 · k-space-sampled=3.3659% | Active MRI Acquisition with Diffusion Guided Bayesian Experimental DesignSource quoteL210: 1 │ 16.0957 │ 0.7890 │ 3.3659 |
| 2025 | Proposed BED procedure proposed | PSNR | 20.6784 | subset=brain · iteration=9 · k-space-sampled=15.6789% | Active MRI Acquisition with Diffusion Guided Bayesian Experimental DesignSource quoteL214: 9 │ 20.6784 │ 0.9104 │ 15.6789 |
| 2025 | Proposed BED procedure proposed | SSIM | 0.9104 | subset=brain · iteration=9 · k-space-sampled=15.6789% | Active MRI Acquisition with Diffusion Guided Bayesian Experimental DesignSource quoteL214: 9 │ 20.6784 │ 0.9104 │ 15.6789 |
| 2024 | Nila (Nila-DC) proposed | PSNR | 37.08 | split: val · noise=none · acceleration=6× | Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRISource quoteL124: Nila (ours) │ \textcolor{red}{37.08} │ \textcolor{red}{95.74} │ \textcolor{red}{34.82} │ \textcolor{red}{94.21} │ \textcolor{red}{36.10} │ \textcolor{red}{94.34} │ \textcolor{red}{33.54} │ \textcolor{red}{91.55} │ \textcolor{red}{30.23} │ \textcolor{red}{91.59} │ \textcolor{red}{29.86} │ \textcolor{red}{90.06} |
| 2024 | Nila (Nila-DC) proposed | PSNR | 31.86 | split: val · noise=Gaussian σ=0.1 · acceleration=6× | Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRISource quoteL145: Nila (ours) │ \textcolor{red}{34.98} │ \textcolor{red}{93.96} │ \textcolor{red}{33.56} │ \textcolor{red}{92.49} │ \textcolor{red}{31.86} │ \textcolor{red}{90.38} │ \textcolor{red}{34.11} │ \textcolor{red}{91.53} │ \textcolor{red}{32.80} │ \textcolor{red}{89.59} │ \textcolor{red}{31.25} │ \textcolor{red}{87.15} |
| 2024 | IR-FRestormerF proposed | SSIM | 0.9427 | split: test · coil=multi-coil · anatomy=brain · ensemble=flip · acceleration=8× | IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI ReconstructionSource quoteL265: 0.9427 |
| 2024 | aSeqDIP proposed | PSNR | 34.08 | split: test · undersampling=4× · averaged-scans=20 | Image Reconstruction Via Autoencoding Sequential Deep Image PriorSource quoteL533: 34.08 |
| 2024 | Policy Classifier proposed | AUC | 0.789 | sample_rate=7% · center_fraction=0.01 | The MRI Scanner as a Diagnostic: Image-less Active SamplingSource quoteL183: 0.717 │ 0.789 │ 0.785 │ 0.784 │ 0.775 │ 0.794 │ 0.752 │ 0.755 │ 0.739 │ 0.742 │ 0.741 │ 0.743 |
| 2024 | Policy Classifier proposed | AUC | 0.794 | sample_rate=25% · center_fraction=0.01 | The MRI Scanner as a Diagnostic: Image-less Active SamplingSource quoteL183: 0.717 │ 0.789 │ 0.785 │ 0.784 │ 0.775 │ 0.794 │ 0.752 │ 0.755 │ 0.739 │ 0.742 │ 0.741 │ 0.743 |
| 2024 | DiffMSR proposed | Diffusion iteration steps | 4 steps | The FastMRI comparison uses the experimental settings referenced in the caption; the pa… | Rethinking Diffusion Model for Multi-Contrast MRI Super-ResolutionSource quoteL10: \caption{Comparison with DM-based MRI reconstruction methods on FastMRI dataset. Note that the experimental settings used by these methods are the same as those in Sec. \ref{exper}. As can be seen, our method has the best reconstruction metric and it only requires 4 iteration steps. Note that DiffuseRecon \cite{peng2022towards}, MC-DDPM \cite{xie2022measurement}, Score-MRI \cite{chung2022score}, and AdaDiff \cite{gungor2023adaptive} are employed for single-contrast SR (SCSR) reconstruction. DisC-Diff \cite{mao2023disc} is specifically designed for multi-contrast SR (MCSR) reconstruction.} |
| 2024 | ADS proposed | SSIM | 91.26 | split: test · resolution=128×128 · acceleration=4× · sampling-fraction=25% | Active Diffusion SubsamplingSource quoteL251: While ADS appears to outperform fixed-mask baselines on MNIST, CelebA, and fastMRI, it is interesting to note that the relative improvement offered by ADS is less pronounced in the case of fastMRI. For line-based image subsampling on MNIST with 25% samples, ADS achieves a 50% reduction in reconstruction error versus a fixed-mask approach (MAE = 0.019 vs 0.037), whereas with line-based \kappa-space subsampling for fastMRI with 25% samples, ADS achieves only a 12% relative improvement (SSIM = 91.26 vs 90.13). We find that the size of this performance gap between fixed and active mask design strategies can be explained by examining the distribution of masks designed by ADS on each task (See Appendix \ref{appendix:mask-distributions}). Indeed, the masks designed for fastMRI are very similar, whereas those designed for MNIST typically differ depending on the sample. When mask designs are similar, then fixed masks will perform similarly to actively designed masks. This is in part a feature of the data distribution -- for example, most information in \kappa-space is contained in the center, at lower frequencies. Tasks in which one might expect significantly better performance from ADS are therefore those in which optimal masks will be highly sample-dependent. |
| 2024 | SPGD Jittering proposed non-standard slice | PSNR | 27.56 | evaluation=adversarial attack · acceleration=4× | SGD Jittering: A Training Strategy for Robust and Accurate Model-Based ArchitecturesSource quoteL421: PSNR / SSIM │ fastMRI │ Adv. Attack │ Tumor Cell MSE training │ 27.93 / 0.582 │ 22.82 / 0.179 │ 29.39 / 0.771 AT │ 27.20 / 0.533 │ 26.78 / 0.518 │ 27.13 / 0.560 Input Jittering │ 24.88 / 0.299 │ 24.44 / 0.297 │ 25.85 / 0.478 SPGD Jittering │ 28.15 / 0.597 │ 27.56 / 0.577 │ 29.762 / 0.777 |
| 2024 | Deform-Mamba (Our) proposed | PSNR | 32.11 | split: test · scale=4× | Deform-Mamba Network for MRI Super-ResolutionSource quoteL180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965 |
| 2024 | Deform-Mamba (Our) proposed | SSIM | 0.7194 | split: test · scale=4× | Deform-Mamba Network for MRI Super-ResolutionSource quoteL180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965 |
| 2024 | FasterFC-U-Net proposed | PSNR | 31.87 | subset=knee, single-coil · sampling=random Cartesian · acceleration=4 | Image Reconstruction for Accelerated MR Scan With Faster Fourier Convolutional Neural NetworksSource quoteL1185: 31.87 |
| 2024 | FasterFC-E2E-VarNet proposed | PSNR | 39.05 | subset=knee, multi-coil · cascades=4 · sampling=random Cartesian · acceleration=4 | Image Reconstruction for Accelerated MR Scan With Faster Fourier Convolutional Neural NetworksSource quoteL1227: 0.0059 39.05 0.9165 |
| 2024 | Self-Guided DIP (Generalized) proposed | Average reconstruction PSNR | 31.77 dB | split: test · anatomy=knee · variant=Generalized · acceleration=4x · average-images=15 | Analysis of Deep Image Prior and Exploiting Self-Guidance for Image ReconstructionSource quoteL627: 31.77 |
| 2024 | DAPS proposed | PSNR | 31.48 | subset=knee · resolution=320x320 · acceleration=4x · diffusion-model=EDM | Improving Diffusion Inverse Problem Solving with Decoupled Noise AnnealingSource quoteL199: DAPS │ 31.48 │ 0.762 │ 1.57 │ 29.01 │ 0.681 │ 1.28 |
| 2024 | DAPS proposed | PSNR | 29.01 | subset=knee · resolution=320x320 · acceleration=8x · diffusion-model=EDM | Improving Diffusion Inverse Problem Solving with Decoupled Noise AnnealingSource quoteL199: DAPS │ 31.48 │ 0.762 │ 1.57 │ 29.01 │ 0.681 │ 1.28 |
| 2024 | HQS (Cheb preconditioner) proposed | PSNR | 34.521 | acceleration-factor=4 | Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI ReconstructionSource quoteL185: HQS │ 34.521 │ 33.251 │ 0.917 │ 0.902 |
| 2024 | HQS (Cheb preconditioner) proposed | PSNR | 33.251 | acceleration-factor=16 | Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI ReconstructionSource quoteL185: HQS │ 34.521 │ 33.251 │ 0.917 │ 0.902 |
| 2024 | HQS (Cheb preconditioner) proposed | SSIM | 0.902 | acceleration-factor=16 | Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI ReconstructionSource quoteL185: HQS │ 34.521 │ 33.251 │ 0.917 │ 0.902 |
| 2024 | SAFI proposed | PSNR | 36.43 | split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=4-fold · coil-setting=single-coil · patch-resolution=320×320 | Iteratively Refined Image Reconstruction with Learned Attentive RegularizersSource quoteL790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860 |
| 2024 | SAFI proposed | PSNR | 36.06 | split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=8-fold · coil-setting=multi-coil · patch-resolution=320×320 | Iteratively Refined Image Reconstruction with Learned Attentive RegularizersSource quoteL790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860 |
| 2024 | TC-KANRecon proposed | PSNR | 30.50 | acceleration-factor=4 | TC-KANRecon: High-Quality and Accelerated MRI Reconstruction via Adaptive KAN Mechanisms and Intelligent Feature ScalingSource quoteL209: TC-KANRecon (Ours) │ 30.50 │ 29.16 │ 27.93 │ 26.83 │ 0.817 │ 0.691 │ 0.624 │ 0.593 │ 0.0211 │ 0.0273 │ 0.0309 │ 0.0371 |
| 2024 | TC-KANRecon proposed | SSIM | 0.817 | acceleration-factor=4 | TC-KANRecon: High-Quality and Accelerated MRI Reconstruction via Adaptive KAN Mechanisms and Intelligent Feature ScalingSource quoteL209: TC-KANRecon (Ours) │ 30.50 │ 29.16 │ 27.93 │ 26.83 │ 0.817 │ 0.691 │ 0.624 │ 0.593 │ 0.0211 │ 0.0273 │ 0.0309 │ 0.0371 |
| 2024 | TC-KANRecon proposed | NMSE | 0.0211 | acceleration-factor=4 | TC-KANRecon: High-Quality and Accelerated MRI Reconstruction via Adaptive KAN Mechanisms and Intelligent Feature ScalingSource quoteL209: TC-KANRecon (Ours) │ 30.50 │ 29.16 │ 27.93 │ 26.83 │ 0.817 │ 0.691 │ 0.624 │ 0.593 │ 0.0211 │ 0.0273 │ 0.0309 │ 0.0371 |
| 2023 | RED-diff proposed | PSNR | 37.1 dB | split: val · coil=multi-coil · subset=6 validation volumes · undersampling=1D equispaced, R=4 | A Variational Perspective on Solving Inverse Problems with Diffusion ModelsSource quoteL482: RED-diff │ 37.1 │ 33.2 │ 32.7 │ 0.114 |
| 2023 | RGFL proposed non-standard slice | Std. Dev. | 9.73E-7 | split: val · speedup=4× | On the Quantification of Image Reconstruction Uncertainty without Training DataSource quoteL210: Std. Dev. \downarrow │ 8.87E-5 │ 1.21E-5 │ 8.82E-6 │ 6.90E-6 │ {\bf 9.73E-7} |
| 2023 | RGFL proposed non-standard slice | Abs. Error | 1.78E-6 | speedup=4× | On the Quantification of Image Reconstruction Uncertainty without Training DataSource quoteL211: Abs. Error \downarrow │ 8.72E-5 │ 3.31E-5 │ 6.91E-6 │ 1.83E-6 │ {\bf 1.78E-6} |
| 2023 | McASSR (Ours; rectangle window 4×16/16×4) proposed | PSNR | 32.52 dB | split: test · scale=4x in-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PD | Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale UpsamplingSource quoteL483: 32.52 |
| 2023 | McASSR (Ours; rectangle window 4×16/16×4) proposed | PSNR | 28.76 dB | split: test · scale=8x out-of-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PD | Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale UpsamplingSource quoteL487: 28.76 |
| 2023 | U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard slice | SSIM | 0.902 | split: test · subset=PDFS knee · test-acceleration=4-fold · training-acceleration=2-, 4-, 8-, and 16-fold | Robustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training DataSource quoteL324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912 |
| 2023 | U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard slice | SSIM | 0.912 | split: test · subset=PDFS knee · test-acceleration=3-fold · training-acceleration=2-, 4-, 8-, and 16-fold | Robustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training DataSource quoteL324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912 |
| 2023 | CDiffMR-LogSR proposed | Inference Time ↓ | 3.030 | anatomy=knee · hardware=NVIDIA RTX 3090 · acceleration-factor=8× | CDiffMR: Can We Replace the Gaussian Noise with K-Space Undersampling for Fast MRI?Source quoteL207: CDiffMR-LogSR │ 0.744 (0.107) │ 27.26 (2.52) │ 0.236 (0.041) │ 3.030 |
| 2023 | JSMoCo (R=2) proposed non-standard slice | NRMSE | 0.0093 | motion=rotation ±2°, translation ±3 pixels · sequence=T2-weighted brain · acceleration=R=2 | JSMoCo: Joint Coil Sensitivity and Motion Correction in Parallel MRI with a Self-Calibrating Score-Based Diffusion ModelSource quoteL384: Ours ( R = 2) │ 0.0093 │ 0.0093 │ 0.0091 │ 0.0099 |
| 2023 | JSMoCo (R=4.8) proposed non-standard slice | NRMSE | 0.0101 | motion=rotation ±2°, translation ±3 pixels · sequence=T2-weighted brain · acceleration=R=4.8 | JSMoCo: Joint Coil Sensitivity and Motion Correction in Parallel MRI with a Self-Calibrating Score-Based Diffusion ModelSource quoteL386: Ours (R = 4.8) │ 0.0101 │ 0.0111 │ 0.0110 │ 0.0107 |
| 2023 | APMC-PnP proposed | PSNR | 32.70 dB | split: test · acceleration=8× | Provable Probabilistic Imaging using Score-based Generative PriorsSource quoteL1750: APMC-PnP (ours) │ 32.70 │ 36.03 |
| 2023 | APMC-PnP proposed | PSNR | 36.03 dB | split: test · acceleration=4× | Provable Probabilistic Imaging using Score-based Generative PriorsSource quoteL1750: APMC-PnP (ours) │ 32.70 │ 36.03 |
| 2023 | Fed-PMG proposed | #Info.cost | 46.88 M | setting=with clustering · measurement=one communication round · field-strength=1.5T | Federated Pseudo Modality Generation for Incomplete Multi-Modal MRI ReconstructionSource quoteL385: Fed-PMG │ 7.40 │ 46.88 │ \Omega(\varphi + K \beta) |
| 2023 | Proposed joint non-linear inversion algorithm with diffusion prior proposed | PSNR | 34.34 | split: val · subset=8% ACL; 15 central slices · contrast=PD · sampling=4-fold Cartesian; swapped phase-encoding direction · resolution=320×320 reference center region | Joint Non-Linear MRI Inversion with Diffusion PriorsSource quoteL304: Cartesian\tnote{*} │ 4 │ 30.37 │ 28.65 │ 32.43 │ 30.88 │ 23.89 │ 29.68 │ 34.34 │ 32.88 |
| 2023 | Proposed joint non-linear inversion algorithm with diffusion prior proposed | PSNR | 31.55 | split: val · subset=15 central slices · contrast=PDFS · sampling=4-fold Gaussian · resolution=320×320 reference center region | Joint Non-Linear MRI Inversion with Diffusion PriorsSource quoteL305: Gaussian │ 4 │ 30.24 │ 27.68 │ 30.91 │ 30.90 │ 22.36 │ 27.35 │ 31.01 │ 31.55 |
| 2023 | Proposed joint non-linear inversion algorithm with diffusion prior proposed | PSNR | 31.78 | split: val · subset=15 central slices · contrast=PDFS · sampling=radial; 45 spokes; 11-fold acceleration · resolution=320×320 reference center region | Joint Non-Linear MRI Inversion with Diffusion PriorsSource quoteL306: Radial │ 11 │ 27.93 │ 26.70 │ 30.66 │ 30.70 │ 19.97 │ 25.55 │ 32.18 │ 31.78 |
| 2023 | Fed-CRFD proposed | PSNR | 35.35 dB | Main comparison; PSNR averaged over three independent trials. The passage mentions β=10… | Cross-Modal Vertical Federated Learning for MRI ReconstructionSource quoteL289: We report the MRI reconstruction performances on two datasets in Table \ref{tab1} under different settings (i.e., \beta = 10% and \beta = 2%). For FL-MRCM and FedMRI, we adopt the settings of the original papers. To alleviate the influence caused by random initialization, the average PSNR, SSIM scores and standard derivation of three independent trials are calculated for the comparing methods and our Fed-CRFD. Additionally, to measure the statistical significance of performance improvements, we conduct the paired t-test for Fed-CRFD and each baseline, and report the p-value as well. As seen, the FL methods significantly outperform Solo, which demonstrates the effectiveness of FL in leveraging multiple clients to obtain a robust global model. Compared to FedAvg, the FL-MRCM achieves almost the same PSNR and even lower SSIM scores. Such an experimental result shows that FL-MRCN cannot tackle the domain shift problem from different modalities. Due to learning the specific information of clients, FedMRI can mitigate the modal difference to some extent compared with FedAvg. Besides, the previous horizontal FL frameworks, i.e., FL-MRCM and FedMRI, have not considered the valuable information of vertical samples. In contrast, thanks to the novel design of our method, our method can effectively address the problem, which significantly improves the PSNR scores from 33.30 dB to 35.35 dB on the fastMRI dataset and from 29.86 dB to 30.95 dB on our private dataset, respectively. Furthermore, our Fed-CRFD is verified to achieve the significant improvement compared to FL-MRCM and FedMRI, i.e., the corresponding p-value < 0.05, and the comparable performance to the centralized model on our private dataset, which show the superiority of our method. |
| 2022 | SwinMR (PI) proposed | Fréchet inception distance (FID) | 35.23 | mask=Gaussian 1D 10% | Swin transformer for fast MRISource quoteL415: G1D10% │ 35.23 │ 169.83 │ 325.99 |
| 2022 | TITLE (Transformer Involved Trajectory LEarning) proposed | phase selection time | 9 ms | coil=single-coil · anatomy=knee | Active Phase-Encode Selection for Slice-Specific Fast MR Scanning Using a Transformer-Based Deep Reinforcement Learning FrameworkSource quoteL830: 9 |
| 2022 | TITLE proposed | averaged SSIM | 0.6745 | coil=single-coil · anatomy=knee · reconstruction=learning-free IFT | Active Phase-Encode Selection for Slice-Specific Fast MR Scanning Using a Transformer-Based Deep Reinforcement Learning FrameworkSource quoteL898: The top part of Table 2 gives the performances of different methods where the images are reconstructed from the selected phases (corresponding incomplete K-space matrices) by learning-free IFT. The averaged SSIM of Random, Zhang, Pineda, and proposed TITLE methods is 0.6203, 0.6315, 0.6411, and 0.6745, respectively. Figure 5 (a) shows several examples of reconstructed images. The proposed method achieves the largest SSIM. SSIM is the most important criterion because of its consistence with eyes of human being. The averaged PSNR of Random, Zhang, Pineda, and TITLE methods is 27.10, 27.55, |
| 2022 | TITLE proposed | SSIM | 0.8163 | coil=single-coil · anatomy=knee · reconstruction=UNet | Active Phase-Encode Selection for Slice-Specific Fast MR Scanning Using a Transformer-Based Deep Reinforcement Learning FrameworkSource quoteL905: NMSE when the UNets converge are given in the bottom part of Table 2. Specifically, the SSIM of the Radom, Zhang, Pineda, and the proposed methods are 0.7962, 0.8020, 0.8113, and 0.8163, respectively. The proposed method achieves the largest SSIM. |
| 2022 | CRR-NN proposed | PSNR | 40.95 | split: test · coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-fold | A Neural-Network-Based Convex Regularizer for Inverse ProblemsSource quoteL794: CRR-NN │ {\bf 40.95} │ 38.91 │ {\bf 0.961} │ 0.934 │ 33.99 │ 33.75 │ 0.880 │ 0.831 |
| 2022 | LLS (\lambda=10 (-6)) proposed | PSNR | 31.54 | split: test · mask=acceleration=4, center_fraction=0.08 · coils=single-coil · lambda=1e-6 · noise_sigma=0.01 · test_images=99 | Improving Lipschitz-Constrained Neural Networks by Learning Activation FunctionsSource quoteL625: LLS │ 31.54 │ 0.7924 │ 28.04 │ 0.7108 |
| 2022 | LLS (\lambda=10 (-6)) proposed | PSNR | 38.68 | mask=Cartesian, acceleration=4, center_fraction=0.08 · coils=15 · lambda=1e-6 · subset=PD · noise_sigma=0.002 | Improving Lipschitz-Constrained Neural Networks by Learning Activation FunctionsSource quoteL639: LLS │ 38.68 │ 37.96 │ 0.943 │ 0.924 │ 32.75 │ 33.61 │ 0.859 │ 0.835 |
| 2022 | K-Space Transformer proposed | PSNR | 27.80 | sampling=uniform-1d · acceleration=5x | K-Space Transformer for Undersampled MRI ReconstructionSource quoteL271: Ours │ \multicolumn{1}{c|}{31.50} │ \multicolumn{1}{c|}{0.9528} │ \multicolumn{1}{c|}{36.32} │ 0.9848 │ \multicolumn{1}{c|}{27.80} │ \multicolumn{1}{c|}{0.7078} │ \multicolumn{1}{c|}{31.04} │ 0.8189 |
| 2022 | rcGAN (cGAN (Ours)) proposed | generation time (4 samples) | 217 ms | samples=4 · contrast=T2 brain · resolution=384×384 · acceleration=R=4 | A Regularized Conditional GAN for Posterior Sampling in Image Recovery ProblemsSource quoteL1183: 3.8e-6 │ 217 ms |
| 2022 | ReconFormer proposed | PSNR | 0.3 dB | acceleration-factor=8× | ReconFormer: Accelerated MRI Reconstruction Using Recurrent TransformerSource quoteL124: by 0.9 dB and 0.3 dB in 8× acceleration, respectively. While the fastMRI dataset is more challenging due to the acquisition quality, all reported improvements achieved by ReconFormer are statistically significant. We provide the detailed statistical significance test in the supplementary material. |
| 2022 | Variable-acceleration VarNet (authors’ “Our VarNet”) proposed | NMSE (×10³) | 1.55 | split: val · coil=multi-coil · anatomy=brain · acceleration=variable | A Path Towards Clinical Adaptation of Accelerated MRISource quoteL290: Our VarNet │ 96.7± 0.02 │ 1.55 │ 43.3± 0.03 |
| 2022 | FedGIMP proposed | PSNR | 28.4 dB | split: test · coil=single-coil · train-test-operator-shift=3x VD to 6x UD | Federated Learning of Generative Image Priors for MRI ReconstructionSource quoteL420: \multirow{1}{*}{FedGIMP} │ 35.3 │ 96.2 │ 28.4 │ 82.7 │ 46.9 │ 99.3 |
| 2022 | FedGIMP proposed | PSNR | 38.4 dB | split: test · coil=multi-coil · test-acceleration=6x | Federated Learning of Generative Image Priors for MRI ReconstructionSource quoteL542: \multirow{2}{*}{FedGIMP} │ 6x │ 38.4 │ 94.5 |
| 2021 | DONet proposed non-standard slice | PSNR | 32.780 dB | split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniform | DONet: Dual-Octave Network for Fast MR Image ReconstructionSource quoteL274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data. |
| 2021 | DONet proposed non-standard slice | SSIM | 0.856 | split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniform | DONet: Dual-Octave Network for Fast MR Image ReconstructionSource quoteL274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data. |
| 2021 | MINet proposed | PSNR | 31.769 dB | scale=2× · evaluation=average score · contrast-setting=HR T1WI auxiliary to restore LR T2WI | Multi-Contrast MRI Super-Resolution via a Multi-Stage Integration NetworkSource quoteL109: MINet │ {\color{red}31.769} │ {\color{red}0.709} │ {\color{red}29.819} │ {\color{red}0.601} │ {\color{red}40.549} │ {\color{red}0.983} │ {\color{red}35.032} │ {\color{red}0.948} │ {\color{red}37.997} │ {\color{red}0.980} │ {\color{red}34.219} │ {\color{red}0.956} |
| 2021 | MINet proposed | SSIM | 0.709 | scale=2× · evaluation=average score · contrast-setting=HR T1WI auxiliary to restore LR T2WI | Multi-Contrast MRI Super-Resolution via a Multi-Stage Integration NetworkSource quoteL109: MINet │ {\color{red}31.769} │ {\color{red}0.709} │ {\color{red}29.819} │ {\color{red}0.601} │ {\color{red}40.549} │ {\color{red}0.983} │ {\color{red}35.032} │ {\color{red}0.948} │ {\color{red}37.997} │ {\color{red}0.980} │ {\color{red}34.219} │ {\color{red}0.956} |
| 2021 | Deep Equilibrium (Grad) proposed | Mean PSNR | 32.01 | split: test · roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8× | Deep Equilibrium Architectures for Inverse Problems in ImagingSource quoteL334: PSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38 |
| 2021 | Joint-ICNet proposed | PSNR | 40.7 | split: test · reduction-factor=4 | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quoteL360: 40.7 |
| 2021 | Joint-ICNet proposed | PSNR | 37.3 | split: test · reduction-factor=8 | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quoteL375: 37.3 |
| 2021 | Joint-ICNet proposed | NRMSE | 0.0087 | split: test · reduction-factor=8 | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quoteL374: 0.0087 |
| 2021 | PDNet w DC proposed | PSNR | 32.66 | split: val · coil=single-coil · coverage=both contrasts · trajectory=radial · acceleration=4 | Density Compensated Unrolled Networks for Non-Cartesian MRI ReconstructionSource quoteL174: PDNet w DC │ 32.66 / 0.7327 │ 33.08 / 0.7534 │ 156k |
| 2021 | PDNet w DC proposed | SSIM | 0.7327 | split: val · coil=single-coil · coverage=both contrasts · trajectory=radial · acceleration=4 | Density Compensated Unrolled Networks for Non-Cartesian MRI ReconstructionSource quoteL174: PDNet w DC │ 32.66 / 0.7327 │ 33.08 / 0.7534 │ 156k |
| 2021 | TDV (stochastic) proposed | PSNR ↑ | 33.5 | acceleration=R=4 · coil-setting=single-coil · stochastic-draws=N=32 | Bayesian Uncertainty Estimation of Learned Variational MRI ReconstructionSource quoteL379: TDV (stochastic) │ 33.5 │ 0.0269 │ 0.762 │ 30.4 │ 0.0412 │ 0.662 │ 9.95 |
| 2021 | TDV (stochastic) proposed | PSNR ↑ | 38.9 | coils=Q=15 · acceleration=R=4 · coil-setting=multi-coil · stochastic-draws=N=32 · coil-sensitivities=not used | Bayesian Uncertainty Estimation of Learned Variational MRI ReconstructionSource quoteL386: TDV (stochastic) │ 38.9 │ 0.0058 │ 0.919 │ 35.2 │ 0.0123 │ 0.867 │ 9.97 |
| 2021 | TDV (stochastic) proposed | PSNR ↑ | 35.2 | coils=Q=15 · acceleration=R=8 · coil-setting=multi-coil · stochastic-draws=N=32 · coil-sensitivities=not used | Bayesian Uncertainty Estimation of Learned Variational MRI ReconstructionSource quoteL386: TDV (stochastic) │ 38.9 │ 0.0058 │ 0.919 │ 35.2 │ 0.0123 │ 0.867 │ 9.97 |
| 2021 | MRAugment with E2E-VarNet proposed | reconstruction SSIM | 0.9049 | subset=2% of training data · scanner-transfer=3T to 3T | Data augmentation for deep learning based accelerated MRI reconstruction with limited dataSource quoteL293: 3T \rightarrow 3T │ 0.8646 │ 0.9049 |
| 2021 | MRAugment with E2E-VarNet proposed | reconstruction SSIM | 0.8913 | subset=2% of training data · scanner-transfer=1.5T to 3T | Data augmentation for deep learning based accelerated MRI reconstruction with limited dataSource quoteL295: 1.5T \rightarrow 3T │ 0.8174 │ 0.8913 |
| 2021 | A-DPS (proposed) proposed | NMSE | 0.0342 | split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 | Active Deep Probabilistic SubsamplingSource quoteL293: 0.0342 |
| 2021 | A-DPS (proposed) proposed | PSNR | 30.2 | split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 | Active Deep Probabilistic SubsamplingSource quoteL294: 30.2 |
| 2021 | A-DPS (proposed) proposed | SSIM | 0.654 | split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 | Active Deep Probabilistic SubsamplingSource quoteL295: 0.654 different in that case. Whereas in the previous experiment |
| 2020 | DeepPhaseCut proposed | PSNR | 19.820 dB | split: test · coil=single-coil · image-type=complex-valued knee images; magnitude metrics · resolution=64×64 · oversampling-ratio=4 | DeepPhaseCut: Deep Relaxation in Phase for Unsupervised Fourier Phase RetrievalSource quoteL628: DeepPhaseCut │ 19.820 │ 0.399 │ 0.042 |
| 2020 | Proposed Co-VeGAN proposed | PSNR | 34.593 dB | split: test · noise=noise-free · undersampling=30% · representation=complex-valued · sampling-pattern=1D-G | Co-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image ReconstructionSource quoteL296: \rule{0pt}{9pt} Proposed │ 1.7M │ 34.593 / 0.7893 │ 34.416 / 0.7870 │ 33.804 / 0.7673 |
| 2020 | Proposed Co-VeGAN proposed | mSSIM | 0.7893 | split: test · noise=noise-free · undersampling=30% · representation=complex-valued · sampling-pattern=1D-G | Co-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image ReconstructionSource quoteL296: \rule{0pt}{9pt} Proposed │ 1.7M │ 34.593 / 0.7893 │ 34.416 / 0.7870 │ 33.804 / 0.7673 |
| 2020 | ReconODE-LT-Euler proposed | PSNR | 31.86 | split: val · subset=single-coil knee · undersampling=4x | MRI Image Reconstruction via Learning Optimization Using Neural ODEsSource quoteL141: ReconODE-LT-Euler │ 0.03M │ 31.86 │ 29.11 │ 0.7194 │ 0.6363 |
| 2020 | ReconODE-LT-Euler proposed | SSIM | 0.7194 | split: val · subset=single-coil knee · undersampling=4x | MRI Image Reconstruction via Learning Optimization Using Neural ODEsSource quoteL141: ReconODE-LT-Euler │ 0.03M │ 31.86 │ 29.11 │ 0.7194 │ 0.6363 |
| 2020 | Proposed pixel-wise RL MRI reconstruction (Ours, with data consistency) proposed non-standard slice | NMSE | 0.14 | split: val · coil=single-coil · subset=first 1,000 validation images · masking=random 40% | MRI Reconstruction with Interpretable Pixel-Wise Operations Using Reinforcement LearningSource quoteL338: 0.14 |
| 2020 | Proposed pixel-wise RL MRI reconstruction (Ours, with data consistency) proposed non-standard slice | PSNR | 30.3 | split: val · coil=single-coil · subset=first 1,000 validation images · masking=random 40% | MRI Reconstruction with Interpretable Pixel-Wise Operations Using Reinforcement LearningSource quoteL339: 30.3 |
| 2020 | Proposed pixel-wise RL MRI reconstruction (Ours, with data consistency) proposed non-standard slice | SSIM | 0.88 | split: val · coil=single-coil · subset=first 1,000 validation images · masking=random 40% | MRI Reconstruction with Interpretable Pixel-Wise Operations Using Reinforcement LearningSource quoteL340: 0.88 the images are of various sizes, we crop the 320x320 center region and then do the down-sampling. In addition, images are normalized and rescaled into range [0, 255]. |
| 2020 | IFR-Net proposed | HFEN | 0.6119 | split: test · subset=50 knee images · channel=single · data-type=complex-valued · sampling-rate=25% · sampling-pattern=2D-random | IFR-Net: Iterative Feature Refinement Network for Compressed Sensing MRISource quoteL1102: 0.6119 |
| 2020 | Orientation adversary (Adversary) proposed | Average rank for visible banding (higher is better) | 2.83 | split: val · acceleration=4× · field-strength=1.5T · central-k-space-lines=16 | MRI Banding Removal via Adversarial TrainingSource quoteL412: Adversary │ 1.09×10 (-11) │ 2.18×10 (-11) │ 2.83\tabularnewline |
| 2020 | Orientation adversary (Adversary) proposed non-standard slice | Average rank for retention of fine anatomical detail versus ground truth (higher is better) | 2.18 | split: val · acceleration=4× · field-strength=1.5T · central-k-space-lines=16 | MRI Banding Removal via Adversarial TrainingSource quoteL432: Adversary │ 2.61 │ 8.82×10 (-4) │ 2.18\tabularnewline |
| 2020 | Orientation adversary (Adversary) proposed | Reports of any banding present (yes/no) | 0.725 proportion | split: val · acceleration=4× · field-strength=1.5T · central-k-space-lines=16 | MRI Banding Removal via Adversarial TrainingSource quoteL454: 0.725 (0.62-0.82) │ 0.967 (0.92-1) │ 0.975 (0.90-0.99)\tabularnewline |
| 2020 | PDS-ATM2 proposed | rSNR | 21.00 dB | split: test · coils=4 · subset=10 images · resolution=128×128 · acceleration=4 · measured-snr=15 dB | Autotuning Plug-and-Play Algorithms for MRISource quoteL343: PDS-ATM2 │ 21.00 │ 0.805 │ 21.44 │ 0.817 │ 21.93 │ 0.833 │ 22.33 │ 0.850 |
| 2020 | PDS-ATM2 proposed | rSNR | 22.33 dB | split: test · coils=4 · subset=10 images · resolution=128×128 · acceleration=4 · measured-snr=23 dB | Autotuning Plug-and-Play Algorithms for MRISource quoteL343: PDS-ATM2 │ 21.00 │ 0.805 │ 21.44 │ 0.817 │ 21.93 │ 0.833 │ 22.33 │ 0.850 |
| 2020 | PDS-ATM2 proposed | iterations to convergence | <30 iterations | split: test · coils=4 · resolution=128×128 · acceleration=4 | Autotuning Plug-and-Play Algorithms for MRISource quoteL316: There we see that PDS-ATM2 converges as fast as genie-tuned PDS (i.e., <30 iterations) and significantly faster than PDS-ATO. |
| 2020 | E2E-VN proposed | SSIM | 0.930 | split: test · anatomy=knee · acceleration=4× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL197: E2E-VN │ 0.930 │ 0.005 │ 40 │ 0.890 │ 0.009 │ 37 |
| 2020 | E2E-VN proposed | SSIM | 0.890 | split: test · anatomy=knee · acceleration=8× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL197: E2E-VN │ 0.930 │ 0.005 │ 40 │ 0.890 │ 0.009 │ 37 |
| 2020 | E2E-VN proposed | SSIM | 0.959 | split: test · anatomy=brain · acceleration=4× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL202: Brain │ E2E-VN │ 0.959 │ 0.004 │ 41 │ 0.943 │ 0.008 │ 38 |
| 2020 | E2E-VN proposed | SSIM | 0.943 | split: test · anatomy=brain · acceleration=8× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL202: Brain │ E2E-VN │ 0.959 │ 0.004 │ 41 │ 0.943 │ 0.008 │ 38 |
| 2020 | OT-cycleGAN (Proposed) proposed | PSNR | 28.7426 dB | split: test · coil=single-coil · subset=ESC · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4x | Unpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGANSource quoteL485: \ │ Proposed │ 28.7426 │ 0.6758 \multirow{8}*{Multi-Coil} │ \multirow{4}*{× 4} │ Input │ 28.0524 │ 0.7616 |
| 2020 | OT-cycleGAN (Proposed) proposed | PSNR | 32.1812 dB | split: test · coil=multi-coil (15-coil) · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4x | Unpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGANSource quoteL488: \ │ Proposed │ 32.1812 │ 0.8300 |
| 2019 | Proposed self-supervised learning (SSL; U-net inverse operator) proposed | PSNR | 22.86 dB | split: val · acceleration=×8 | Self-supervised learning of inverse problem solvers in medical imagingSource quoteL130: PSNR │ 13.74 │ N/A │ 22.86 │ 26.72 |
| 2019 | Proposed self-supervised learning (SSL; U-net inverse operator) proposed | SSIM | 0.47 | split: val · acceleration=×8 | Self-supervised learning of inverse problem solvers in medical imagingSource quoteL131: SSIM │ 0.40 │ N/A │ 0.47 │ 0.604 |
| 2019 | Offset 0 sampling proposed | SSIM | 0.924 | split: val · sampling=Offset 0 · coil-setup=multi-coil · acceleration=4x · low-frequency-lines=16 | Offset Masking Improves Deep Learning based Accelerated MRI ReconstructionsSource quoteL261: knee MRI reconstruction, showing an improvement in SSIM from 0.924 |
| 2019 | Offset 1 sampling proposed | SSIM | 0.926 | split: val · sampling=Offset 1 · coil-setup=multi-coil · acceleration=4x · low-frequency-lines=16 | Offset Masking Improves Deep Learning based Accelerated MRI ReconstructionsSource quoteL262: to 0.926.} |
| 2019 | unpaired WGAN proposed | SSIM | 0.822 | split: test · unpaired · training=7 input subjects, 6 disjoint label subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersampling | Wasserstein GANs for MR Imaging: From Paired to Unpaired TrainingSource quoteL217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831 |
| 2019 | WGAN+ℓ₁ proposed | SSIM | 0.824 | split: test · paired · training=6 subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersampling | Wasserstein GANs for MR Imaging: From Paired to Unpaired TrainingSource quoteL217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831 |
| 2019 | PC-RNN (multi-coil) proposed | PSNR | 39.0 | split: val · coil=multi-coil · acceleration=4x | Pyramid Convolutional RNN for MRI ReconstructionSource quoteL134: Multi-coil │ PC-RNN │ 39.0 │ 36.5 │ 0.914 │ 0.884 |
| 2019 | PC-RNN (multi-coil) proposed | PSNR | 36.5 | split: val · coil=multi-coil · acceleration=8x | Pyramid Convolutional RNN for MRI ReconstructionSource quoteL134: Multi-coil │ PC-RNN │ 39.0 │ 36.5 │ 0.914 │ 0.884 |
| 2019 | PC-RNN (single-coil) proposed | PSNR | 31.3 | split: val · coil=single-coil · acceleration=8x | Pyramid Convolutional RNN for MRI ReconstructionSource quoteL131: Single-coil │ PC-RNN │ 32.8 │ 31.3 │ 0.743 │ 0.682 |
| 2018 | DeepALOHA proposed | PSNR | 35.5181 dB | coil=single-coil · acceleration=R=3 | k-Space Deep Learning for Accelerated MRISource quoteL572: \ PSNR [dB] │ 31.0201 │ 33.3799 │ 35.5181 |