fastMRI

86 papers · 287 extracted observations · mri reconstruction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

22.829.335.842.3202120242026A-DPS (proposed): 30.2 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 35.8 (2021)Joint-ICNet: 37.3 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 39.4 (2021)Joint-ICNet: 40.7 (2021)Deep Equilibrium (Grad): 32.01 (2021)CRR-NN: 40.95 (2023)LLS (\lambda=10 (-6)): 31.54 (2024)aSeqDIP: 34.08 (2024)Deform-Mamba (Our): 32.11 (2024)SAFI: 36.06 (2024)SAFI: 36.43 (2024)Interleaved (self-supervised loss added during training): 31.55 (2025)DEAL: 36.21 (2025)DEAL: 36.59 (2025)MFoE: 35.4 (2025)Distilled (on-policy privileged information distillation): 24.11 (2026)Distilled (on-policy privileged information distillation): 26.0 (2026)Distilled (on-policy privileged information distillation): 27.86 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 67 of 67 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026OCDI-Net proposedSSIM0.966SMS=MB3R1 · subset=T2 · reconstruction=single-stage SMS unaliasing · image-representation=RSS magnitudeBack to Physics: Operator-Guided Generative Paths for SMS MRI Reconstruction
Source quote
L619: OCDI-Net │ 41.88 │ 0.966 │ \boldsymbol{2.5× 10 (-3)}
2026EvoML proposedSSIM0.9498split: test · supervisedValidation-Gated ML Pipeline Synthesis with Expert-Grounded Self-Evolving Skills
Source quote
L975: The margin is largest on the harder tasks, reaching 0.9498
2026PAS-Mamba proposedSSIM0.8838Radial mask, ×2 acceleration.PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI Reconstruction
Source quote
L241: Ours │ 32.46 │ 0.8838 │ 28.84 │ 0.8301
2026PAS-Mamba proposedSSIM0.7081Cartesian mask, ×4 acceleration.PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI Reconstruction
Source quote
L249: Ours │ 28.35 │ 0.7058 │ 26.47 │ 0.7081
2026No cross-attention ablationSSIM0.949SMS=MB3R1 · subset=T2 · variant=no cross-attention · reconstruction=single-stage SMS unaliasing · image-representation=RSS magnitudeBack to Physics: Operator-Guided Generative Paths for SMS MRI Reconstruction
Source quote
L618: No cross-attention │ 37.92 │ 0.949 │ 6.6× 10 (-3)
2025PR-INR proposedSSIM0.919motion-displacement=3%From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction
Source quote
L617: Table~\ref{tab:ablation_final} shows that the full configuration of our PR-INR framework consistently achieves the best performance across all undersampling settings on both the FastMRI and HCP 1200 datasets. At 3% and 5% displacement during acquisition, the complete model achieves strong gains over the baseline. For instance, PSNR/SSIM improves from 30.0/0.853 to 33.3/0.919 on FastMRI, and from 24.3/0.820 to 27.0/0.904 on HCP 1200 at 3%, with similar trends at 5%. Under 4x and 8x undersampling, PR-INR remains robust, consistently outperforming variants. At 8x, it improves PSNR from 23.9 to 26.4 and SSIM from 0.645 to 0.721 on FastMRI, and shows comparable improvements on HCP. The IDR module plays a key role in enhancing perceptual and structural quality (e.g., LPIPS drops and SSIM improves), while the VCR module further enforces volumetric smoothness, reflected in higher NCC values. These results validate the complementary contributions of each module and the generalizability of PR-INR across different datasets and acceleration regimes.
2025Interleaved (self-supervised loss added during training) proposedSSIM.7910split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brainBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L283: Interleaved │ 31.55 │ .7910
2025SelfDB proposedSSIM0.882split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L137: SelfDB │ 0.108 │ 0.882 │ 0.036
2025HiFi-MambaV2 (P1) proposedSSIM0.855Equispaced sampling; acceleration factor ×4HiFi-MambaV2: Hierarchical Shared-Routed MoE for High-Fidelity MRI Reconstruction
Source quote
L295: On fastMRI, V2(P1) attains 34.86\,dB/0.855 SSIM at 4× and 31.89\,dB/0.764 SSIM at 8×, outperforming LMO by +0.37\,dB/+0.011 and +0.79\,dB/+0.020, respectively.
2025HiFi-MambaV2 (P1) proposedSSIM0.764Equispaced sampling; acceleration factor ×8HiFi-MambaV2: Hierarchical Shared-Routed MoE for High-Fidelity MRI Reconstruction
Source quote
L295: On fastMRI, V2(P1) attains 34.86\,dB/0.855 SSIM at 4× and 31.89\,dB/0.764 SSIM at 8×, outperforming LMO by +0.37\,dB/+0.011 and +0.79\,dB/+0.020, respectively.
2025Proposed BED procedure proposedSSIM0.7890subset=brain · iteration=1 · k-space-sampled=3.3659%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L210: 1 │ 16.0957 │ 0.7890 │ 3.3659
2025Proposed BED procedure proposedSSIM0.9104subset=brain · iteration=9 · k-space-sampled=15.6789%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L214: 9 │ 20.6784 │ 0.9104 │ 15.6789
2025Supervised learning baseline non-standard sliceSSIM.8141split: test · anatomy=knee · training=supervised with oracle ground truth · acceleration=6xBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L414: (Supervised) │ (32.68) │ (.8141)
2025C-Ambient-DDM baselineSSIM0.833split: test · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L136: C-Ambient-DDM │ 0.113 │ 0.833 │ 0.056
2025ADS baselinemean SSIM91.26split: test · subset=knee · k-space-subsampling=25%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L227: ADS \citep{nolan2024} │ 91.26
2024IR-FRestormerF proposedSSIM0.9427split: test · coil=multi-coil · anatomy=brain · ensemble=flip · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L265: 0.9427
2024ADS proposedSSIM91.26split: test · resolution=128×128 · acceleration=4× · sampling-fraction=25%Active Diffusion Subsampling
Source quote
L251: While ADS appears to outperform fixed-mask baselines on MNIST, CelebA, and fastMRI, it is interesting to note that the relative improvement offered by ADS is less pronounced in the case of fastMRI. For line-based image subsampling on MNIST with 25% samples, ADS achieves a 50% reduction in reconstruction error versus a fixed-mask approach (MAE = 0.019 vs 0.037), whereas with line-based \kappa-space subsampling for fastMRI with 25% samples, ADS achieves only a 12% relative improvement (SSIM = 91.26 vs 90.13). We find that the size of this performance gap between fixed and active mask design strategies can be explained by examining the distribution of masks designed by ADS on each task (See Appendix \ref{appendix:mask-distributions}). Indeed, the masks designed for fastMRI are very similar, whereas those designed for MNIST typically differ depending on the sample. When mask designs are similar, then fixed masks will perform similarly to actively designed masks. This is in part a feature of the data distribution -- for example, most information in \kappa-space is contained in the center, at lower frequencies. Tasks in which one might expect significantly better performance from ADS are therefore those in which optimal masks will be highly sample-dependent.
2024Deform-Mamba (Our) proposedSSIM0.7194split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965
2024HQS (Cheb preconditioner) proposedSSIM0.902acceleration-factor=16Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI Reconstruction
Source quote
L185: HQS │ 34.521 │ 33.251 │ 0.917 │ 0.902
2024TC-KANRecon proposedSSIM0.817acceleration-factor=4TC-KANRecon: High-Quality and Accelerated MRI Reconstruction via Adaptive KAN Mechanisms and Intelligent Feature Scaling
Source quote
L209: TC-KANRecon (Ours) │ 30.50 │ 29.16 │ 27.93 │ 26.83 │ 0.817 │ 0.691 │ 0.624 │ 0.593 │ 0.0211 │ 0.0273 │ 0.0309 │ 0.0371
2024DIRCN [28] baselineSSIM0.9455split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L262: 0.9455
2024E2E-VarNet [34] baselineSSIM0.9426split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L268: 0.9426
2024XPDNet [31] baselineSSIM0.9408split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L271: 0.9408
2024HQS-Net [41] baselineSSIM0.9400split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L274: 0.9400
2024U-Net [46] baselineSSIM0.9282split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L277: 0.9282
2024Fixed-mask DPS baselineSSIM90.13split: test · resolution=128×128 · acceleration=4× · sampling-fraction=25%Active Diffusion Subsampling
Source quote
L251: While ADS appears to outperform fixed-mask baselines on MNIST, CelebA, and fastMRI, it is interesting to note that the relative improvement offered by ADS is less pronounced in the case of fastMRI. For line-based image subsampling on MNIST with 25% samples, ADS achieves a 50% reduction in reconstruction error versus a fixed-mask approach (MAE = 0.019 vs 0.037), whereas with line-based \kappa-space subsampling for fastMRI with 25% samples, ADS achieves only a 12% relative improvement (SSIM = 91.26 vs 90.13). We find that the size of this performance gap between fixed and active mask design strategies can be explained by examining the distribution of masks designed by ADS on each task (See Appendix \ref{appendix:mask-distributions}). Indeed, the masks designed for fastMRI are very similar, whereas those designed for MNIST typically differ depending on the sample. When mask designs are similar, then fixed masks will perform similarly to actively designed masks. This is in part a feature of the data distribution -- for example, most information in \kappa-space is contained in the center, at lower frequencies. Tasks in which one might expect significantly better performance from ADS are therefore those in which optimal masks will be highly sample-dependent.
2024T (2)Net baselineSSIM0.6244split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L178: T (2)Net │ 30.56 │ 0.6244 │ 29.73 │ 0.8773
2024NCPDNET baselineSSIM0.916acceleration-factor=16 · training-acceleration-factor=4Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI Reconstruction
Source quote
L201: NCPDNET │ 37.765 │ 29.912 │ 0.977 │ 0.916
2023U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard sliceSSIM0.902split: test · subset=PDFS knee · test-acceleration=4-fold · training-acceleration=2-, 4-, 8-, and 16-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912
2023U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard sliceSSIM0.912split: test · subset=PDFS knee · test-acceleration=3-fold · training-acceleration=2-, 4-, 8-, and 16-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912
2023U-net trained on 4-fold acceleration data baseline non-standard sliceSSIM0.903split: test · subset=PDFS knee · test-acceleration=4-fold · training-acceleration=4-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L321: 4-fold │ --- │ 0.903 │ --- │ --- │ 0.899
2023U-net trained on 2-fold acceleration data baseline non-standard sliceSSIM0.906split: test · subset=PDFS knee · test-acceleration=3-fold · training-acceleration=2-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L320: 2-fold │ 0.945 │ --- │ --- │ --- │ 0.906
2023DDPM (Xie et al.) baselineSSIM0.905contrast=proton-density · acceleration-factor=4A survey of emerging applications of diffusion probabilistic models in MRI
Source quote
L619: \cite{xie2022measurement} │ DDPM │ 36.69 │ 0.905
2023CNN (Ronneberger et al.) baselineSSIM0.834contrast=proton-density · acceleration-factor=4A survey of emerging applications of diffusion probabilistic models in MRI
Source quote
L618: \cite{ronneberger2015u} │ CNN │ 34.04\tnote{a} │ 0.834\tnote{a}
2022TITLE proposedaveraged SSIM0.6745coil=single-coil · anatomy=knee · reconstruction=learning-free IFTActive Phase-Encode Selection for Slice-Specific Fast MR Scanning Using a Transformer-Based Deep Reinforcement Learning Framework
Source quote
L898: The top part of Table 2 gives the performances of different methods where the images are reconstructed from the selected phases (corresponding incomplete K-space matrices) by learning-free IFT. The averaged SSIM of Random, Zhang, Pineda, and proposed TITLE methods is 0.6203, 0.6315, 0.6411, and 0.6745, respectively. Figure 5 (a) shows several examples of reconstructed images. The proposed method achieves the largest SSIM. SSIM is the most important criterion because of its consistence with eyes of human being. The averaged PSNR of Random, Zhang, Pineda, and TITLE methods is 27.10, 27.55,
2022TITLE proposedSSIM0.8163coil=single-coil · anatomy=knee · reconstruction=UNetActive Phase-Encode Selection for Slice-Specific Fast MR Scanning Using a Transformer-Based Deep Reinforcement Learning Framework
Source quote
L905: NMSE when the UNets converge are given in the bottom part of Table 2. Specifically, the SSIM of the Radom, Zhang, Pineda, and the proposed methods are 0.7962, 0.8020, 0.8113, and 0.8163, respectively. The proposed method achieves the largest SSIM.
2022Pineda baselineaveraged SSIM0.6411coil=single-coil · anatomy=knee · reconstruction=learning-free IFTActive Phase-Encode Selection for Slice-Specific Fast MR Scanning Using a Transformer-Based Deep Reinforcement Learning Framework
Source quote
L898: The top part of Table 2 gives the performances of different methods where the images are reconstructed from the selected phases (corresponding incomplete K-space matrices) by learning-free IFT. The averaged SSIM of Random, Zhang, Pineda, and proposed TITLE methods is 0.6203, 0.6315, 0.6411, and 0.6745, respectively. Figure 5 (a) shows several examples of reconstructed images. The proposed method achieves the largest SSIM. SSIM is the most important criterion because of its consistence with eyes of human being. The averaged PSNR of Random, Zhang, Pineda, and TITLE methods is 27.10, 27.55,
2022Pineda baselineSSIM0.8113coil=single-coil · anatomy=knee · reconstruction=UNetActive Phase-Encode Selection for Slice-Specific Fast MR Scanning Using a Transformer-Based Deep Reinforcement Learning Framework
Source quote
L905: NMSE when the UNets converge are given in the bottom part of Table 2. Specifically, the SSIM of the Radom, Zhang, Pineda, and the proposed methods are 0.7962, 0.8020, 0.8113, and 0.8163, respectively. The proposed method achieves the largest SSIM.
2021DONet proposed non-standard sliceSSIM0.856split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniformDONet: Dual-Octave Network for Fast MR Image Reconstruction
Source quote
L274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data.
2021MINet proposedSSIM0.709scale=2× · evaluation=average score · contrast-setting=HR T1WI auxiliary to restore LR T2WIMulti-Contrast MRI Super-Resolution via a Multi-Stage Integration Network
Source quote
L109: MINet │ {\color{red}31.769} │ {\color{red}0.709} │ {\color{red}29.819} │ {\color{red}0.601} │ {\color{red}40.549} │ {\color{red}0.983} │ {\color{red}35.032} │ {\color{red}0.948} │ {\color{red}37.997} │ {\color{red}0.980} │ {\color{red}34.219} │ {\color{red}0.956}
2021PDNet w DC proposedSSIM0.7327split: val · coil=single-coil · coverage=both contrasts · trajectory=radial · acceleration=4Density Compensated Unrolled Networks for Non-Cartesian MRI Reconstruction
Source quote
L174: PDNet w DC │ 32.66 / 0.7327 │ 33.08 / 0.7534 │ 156k
2021MRAugment with E2E-VarNet proposedreconstruction SSIM0.9049subset=2% of training data · scanner-transfer=3T to 3TData augmentation for deep learning based accelerated MRI reconstruction with limited data
Source quote
L293: 3T \rightarrow 3T │ 0.8646 │ 0.9049
2021MRAugment with E2E-VarNet proposedreconstruction SSIM0.8913subset=2% of training data · scanner-transfer=1.5T to 3TData augmentation for deep learning based accelerated MRI reconstruction with limited data
Source quote
L295: 1.5T \rightarrow 3T │ 0.8174 │ 0.8913
2021A-DPS (proposed) proposedSSIM0.654split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L295: 0.654 different in that case. Whereas in the previous experiment
2021E2E-VarNet (no DA) ablationreconstruction SSIM0.8646subset=2% of training data · scanner-transfer=3T to 3TData augmentation for deep learning based accelerated MRI reconstruction with limited data
Source quote
L293: 3T \rightarrow 3T │ 0.8646 │ 0.9049
2021E2E-VarNet (no DA) ablationreconstruction SSIM0.8174subset=2% of training data · scanner-transfer=1.5T to 3TData augmentation for deep learning based accelerated MRI reconstruction with limited data
Source quote
L295: 1.5T \rightarrow 3T │ 0.8174 │ 0.8913
2021ComplexMRI baseline non-standard sliceSSIM0.829split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniformDONet: Dual-Octave Network for Fast MR Image Reconstruction
Source quote
L274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data.
2021Center undersampling pattern baselineSSIM0.693acceleration=×4 · reconstruction=zero-filledOptimal MRI Undersampling Patterns for Ultimate Benefit of Medical Vision Tasks
Source quote
L285: Center │ 0.693 │ 26.850 │ 0.029 │ 0.635 │ 20.969 │ 0.263
2021DPS baselineSSIM0.650split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L291: 0.650
2020ReconODE-LT-Euler proposedSSIM0.7194split: val · subset=single-coil knee · undersampling=4xMRI Image Reconstruction via Learning Optimization Using Neural ODEs
Source quote
L141: ReconODE-LT-Euler │ 0.03M │ 31.86 │ 29.11 │ 0.7194 │ 0.6363
2020Proposed pixel-wise RL MRI reconstruction (Ours, with data consistency) proposed non-standard sliceSSIM0.88split: val · coil=single-coil · subset=first 1,000 validation images · masking=random 40%MRI Reconstruction with Interpretable Pixel-Wise Operations Using Reinforcement Learning
Source quote
L340: 0.88 the images are of various sizes, we crop the 320x320 center region and then do the down-sampling. In addition, images are normalized and rescaled into range [0, 255].
2020E2E-VN proposedSSIM0.930split: test · anatomy=knee · acceleration=4×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L197: E2E-VN │ 0.930 │ 0.005 │ 40 │ 0.890 │ 0.009 │ 37
2020E2E-VN proposedSSIM0.890split: test · anatomy=knee · acceleration=8×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L197: E2E-VN │ 0.930 │ 0.005 │ 40 │ 0.890 │ 0.009 │ 37
2020E2E-VN proposedSSIM0.959split: test · anatomy=brain · acceleration=4×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L202: Brain │ E2E-VN │ 0.959 │ 0.004 │ 41 │ 0.943 │ 0.008 │ 38
2020E2E-VN proposedSSIM0.943split: test · anatomy=brain · acceleration=8×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L202: Brain │ E2E-VN │ 0.959 │ 0.004 │ 41 │ 0.943 │ 0.008 │ 38
2020Philips & LUMC (challenge submission) baseline non-standard sliceSSIM0.901coil=multi-coil · acceleration=R=8Advancing machine learning for MR image reconstruction with an open competition: Overview of the 2019 fastMRI challenge
Source quote
L149: Philips \ │ LUMC │ 1 │ 1.286 │ 0.901 │ 0.0086 │ 37.437
2020AImsterdam (challenge submission) baseline non-standard sliceSSIM0.754coil=single-coil · acceleration=R=4Advancing machine learning for MR image reconstruction with an open competition: Overview of the 2019 fastMRI challenge
Source quote
L161: AImsterdam │ 1 │ 1.286 │ 0.754 │ 0.031 │ 32.549
2020UNet baselineSSIM0.7177split: val · subset=single-coil knee · undersampling=4xMRI Image Reconstruction via Learning Optimization Using Neural ODEs
Source quote
L132: UNet │ 3.35M │ 31.84 │ 29.87 │ 0.7177 │ 0.6514
2020SubtleMR baselineSSIM0.888split: test · anatomy=knee · acceleration=8×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L198: SubtleMR │ 0.929 │ 0.005 │ 40 │ 0.888 │ 0.009 │ 37
2020U-Net baselineSSIM0.915split: test · anatomy=brain · acceleration=8×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L203: U-Net │ 0.945 │ 0.011 │ 38 │ 0.915 │ 0.023 │ 35
2019Proposed self-supervised learning (SSL; U-net inverse operator) proposedSSIM0.47split: val · acceleration=×8Self-supervised learning of inverse problem solvers in medical imaging
Source quote
L131: SSIM │ 0.40 │ N/A │ 0.47 │ 0.604
2019Offset 0 sampling proposedSSIM0.924split: val · sampling=Offset 0 · coil-setup=multi-coil · acceleration=4x · low-frequency-lines=16Offset Masking Improves Deep Learning based Accelerated MRI Reconstructions
Source quote
L261: knee MRI reconstruction, showing an improvement in SSIM from 0.924
2019Offset 1 sampling proposedSSIM0.926split: val · sampling=Offset 1 · coil-setup=multi-coil · acceleration=4x · low-frequency-lines=16Offset Masking Improves Deep Learning based Accelerated MRI Reconstructions
Source quote
L262: to 0.926.}
2019unpaired WGAN proposedSSIM0.822split: test · unpaired · training=7 input subjects, 6 disjoint label subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersamplingWasserstein GANs for MR Imaging: From Paired to Unpaired Training
Source quote
L217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831
2019WGAN+ℓ₁ proposedSSIM0.824split: test · paired · training=6 subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersamplingWasserstein GANs for MR Imaging: From Paired to Unpaired Training
Source quote
L217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831
2019Supervised restoration model baselineSSIM0.604split: val · acceleration=×8Self-supervised learning of inverse problem solvers in medical imaging
Source quote
L131: SSIM │ 0.40 │ N/A │ 0.47 │ 0.604
2019ℓ₁-net baselineSSIM0.828split: test · paired · training=6 subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersamplingWasserstein GANs for MR Imaging: From Paired to Unpaired Training
Source quote
L217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831