fastMRI
86 papers · 287 extracted observations · mri reconstruction · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CRR-NN SOTA frontier | 40.95 | 2023-01-01 | coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-fold · FastMRI knee PD test images; 2-fold Cartesian undersampling, measurement noise standa… | A Neural-Network-Based Convex Regularizer for Inverse ProblemsSource quoteCRR-NN │ {\bf 40.95} │ 38.91 │ {\bf 0.961} │ 0.934 │ 33.99 │ 33.75 │ 0.880 │ 0.831 |
| 2 | Joint-ICNet SOTA frontier (+3 variants) | 40.7 | 2021-01-01 | reduction-factor=4 · Table 2 model ablation; reduction factor R=4. Paper setup uses multi-coil k-space ret… | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quote40.7 |
| 3 | DEAL (+1 variant) | 36.59 | 2025-01-01 | coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-fold · 4-fold single-coil setup; centered 320×320 patches from 50 test images; additive whit… | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteDEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32 |
| 4 | SAFI (+1 variant) | 36.43 | 2024-07-01 | subset=50 test images · sequence=PD · resolution=320x320 · acceleration=4-fold · coil-setting=single-coil · patch-resolution=320×320 · PD knee images without fat suppression; denoising-trained model, with λ tuned on 10 v… | Iteratively Refined Image Reconstruction with Learned Attentive RegularizersSource quoteSAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860 |
| 5 | MFoE | 35.4 | 2025-08-01 | noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4 · PD data; acceleration factor 4 and center fraction 0.08; Gaussian measurement noise w… | Multivariate Fields of ExpertsSource quoteMFoE │ 35.40 │ 34.21 │ 30.26 │ 31.20 |
| 6 | aSeqDIP | 34.08 | 2024-01-01 | undersampling=4× · averaged-scans=20 · Average over 20 MRI scans from the fastMRI testing set at 4× undersampling; no labele… | Image Reconstruction Via Autoencoding Sequential Deep Image PriorSource quote34.08 |
| 7 | Deform-Mamba (Our) | 32.11 | 2024-07-01 | scale=4× · 4× upsampling; held-out test split (45 subjects); low-resolution inputs synthesized i… | Deform-Mamba Network for MRI Super-ResolutionSource quoteOur │ 32.11 │ 0.7194 │ 30.60 │ 0.8965 |
| 8 | Deep Equilibrium (Grad) | 32.01 | 2021-02-01 | roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8× · Test-set mean; 8× accelerated virtual single-coil Cartesian MRI with complex AWGN sta… | Deep Equilibrium Architectures for Inverse Problems in ImagingSource quotePSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38 |
| 9 | Interleaved (self-supervised loss added during training) | 31.55 | 2025-01-01 | method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brain · 6x-accelerated MRI; trained on the FastMRI brain dataset and tested on knees. | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteInterleaved │ 31.55 │ .7910 |
| 10 | LLS (\lambda=10 (-6)) | 31.54 | 2024-01-01 | mask=acceleration=4, center_fraction=0.08 · coils=single-coil · lambda=1e-6 · noise_sigma=0.01 · test_images=99 · PnP-FBS reconstruction; measurement noise \sigma-\mathbf n=0.01; mask (M_{\text{acc}}… | Improving Lipschitz-Constrained Neural Networks by Learning Activation FunctionsSource quoteLLS │ 31.54 │ 0.7924 │ 28.04 │ 0.7108 |
| 11 | A-DPS (proposed) | 30.2 | 2021-01-01 | resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 · Table 2: acceleration factor 8; scenario-30L (30 k-space lines closest to DC, with 16… | Active Deep Probabilistic SubsamplingSource quote30.2 |
| 12 | Distilled (on-policy privileged information distillation) (+2 variants) | 27.86 | 2026-05-01 | contrast=T1 · acceleration=R=32 · undersampling=Gaussian-VD · R=32; Gaussian-VD undersampling; T1 contrast. | Next-Acceleration-Scale Prediction for Autoregressive MRI ReconstructionSource quoteDistilled │ 27.86 │ 22.29 │ 24.08 │ 0.81 │ 0.70 │ 0.67 │ 0.148 │ 0.161 │ 0.162 |
Showing 67 of 67 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | OCDI-Net proposed | SSIM | 0.966 | SMS=MB3R1 · subset=T2 · reconstruction=single-stage SMS unaliasing · image-representation=RSS magnitude | Back to Physics: Operator-Guided Generative Paths for SMS MRI ReconstructionSource quoteL619: OCDI-Net │ 41.88 │ 0.966 │ \boldsymbol{2.5× 10 (-3)} |
| 2026 | EvoML proposed | SSIM | 0.9498 | split: test · supervised | Validation-Gated ML Pipeline Synthesis with Expert-Grounded Self-Evolving SkillsSource quoteL975: The margin is largest on the harder tasks, reaching 0.9498 |
| 2026 | PAS-Mamba proposed | SSIM | 0.8838 | Radial mask, ×2 acceleration. | PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI ReconstructionSource quoteL241: Ours │ 32.46 │ 0.8838 │ 28.84 │ 0.8301 |
| 2026 | PAS-Mamba proposed | SSIM | 0.7081 | Cartesian mask, ×4 acceleration. | PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI ReconstructionSource quoteL249: Ours │ 28.35 │ 0.7058 │ 26.47 │ 0.7081 |
| 2026 | No cross-attention ablation | SSIM | 0.949 | SMS=MB3R1 · subset=T2 · variant=no cross-attention · reconstruction=single-stage SMS unaliasing · image-representation=RSS magnitude | Back to Physics: Operator-Guided Generative Paths for SMS MRI ReconstructionSource quoteL618: No cross-attention │ 37.92 │ 0.949 │ 6.6× 10 (-3) |
| 2025 | PR-INR proposed | SSIM | 0.919 | motion-displacement=3% | From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI ReconstructionSource quoteL617: Table~\ref{tab:ablation_final} shows that the full configuration of our PR-INR framework consistently achieves the best performance across all undersampling settings on both the FastMRI and HCP 1200 datasets. At 3% and 5% displacement during acquisition, the complete model achieves strong gains over the baseline. For instance, PSNR/SSIM improves from 30.0/0.853 to 33.3/0.919 on FastMRI, and from 24.3/0.820 to 27.0/0.904 on HCP 1200 at 3%, with similar trends at 5%. Under 4x and 8x undersampling, PR-INR remains robust, consistently outperforming variants. At 8x, it improves PSNR from 23.9 to 26.4 and SSIM from 0.645 to 0.721 on FastMRI, and shows comparable improvements on HCP. The IDR module plays a key role in enhancing perceptual and structural quality (e.g., LPIPS drops and SSIM improves), while the VCR module further enforces volumetric smoothness, reflected in higher NCC values. These results validate the complementary contributions of each module and the generalizability of PR-INR across different datasets and acceleration regimes. |
| 2025 | Interleaved (self-supervised loss added during training) proposed | SSIM | .7910 | split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brain | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteL283: Interleaved │ 31.55 │ .7910 |
| 2025 | SelfDB proposed | SSIM | 0.882 | split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25% | A Self-Supervised Diffusion Bridge for MRI ReconstructionSource quoteL137: SelfDB │ 0.108 │ 0.882 │ 0.036 |
| 2025 | HiFi-MambaV2 (P1) proposed | SSIM | 0.855 | Equispaced sampling; acceleration factor ×4 | HiFi-MambaV2: Hierarchical Shared-Routed MoE for High-Fidelity MRI ReconstructionSource quoteL295: On fastMRI, V2(P1) attains 34.86\,dB/0.855 SSIM at 4× and 31.89\,dB/0.764 SSIM at 8×, outperforming LMO by +0.37\,dB/+0.011 and +0.79\,dB/+0.020, respectively. |
| 2025 | HiFi-MambaV2 (P1) proposed | SSIM | 0.764 | Equispaced sampling; acceleration factor ×8 | HiFi-MambaV2: Hierarchical Shared-Routed MoE for High-Fidelity MRI ReconstructionSource quoteL295: On fastMRI, V2(P1) attains 34.86\,dB/0.855 SSIM at 4× and 31.89\,dB/0.764 SSIM at 8×, outperforming LMO by +0.37\,dB/+0.011 and +0.79\,dB/+0.020, respectively. |
| 2025 | Proposed BED procedure proposed | SSIM | 0.7890 | subset=brain · iteration=1 · k-space-sampled=3.3659% | Active MRI Acquisition with Diffusion Guided Bayesian Experimental DesignSource quoteL210: 1 │ 16.0957 │ 0.7890 │ 3.3659 |
| 2025 | Proposed BED procedure proposed | SSIM | 0.9104 | subset=brain · iteration=9 · k-space-sampled=15.6789% | Active MRI Acquisition with Diffusion Guided Bayesian Experimental DesignSource quoteL214: 9 │ 20.6784 │ 0.9104 │ 15.6789 |
| 2025 | Supervised learning baseline non-standard slice | SSIM | .8141 | split: test · anatomy=knee · training=supervised with oracle ground truth · acceleration=6x | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteL414: (Supervised) │ (32.68) │ (.8141) |
| 2025 | C-Ambient-DDM baseline | SSIM | 0.833 | split: test · test-subsampling=12.5% · train-subsampling=25% | A Self-Supervised Diffusion Bridge for MRI ReconstructionSource quoteL136: C-Ambient-DDM │ 0.113 │ 0.833 │ 0.056 |
| 2025 | ADS baseline | mean SSIM | 91.26 | split: test · subset=knee · k-space-subsampling=25% | Active MRI Acquisition with Diffusion Guided Bayesian Experimental DesignSource quoteL227: ADS \citep{nolan2024} │ 91.26 |
| 2024 | IR-FRestormerF proposed | SSIM | 0.9427 | split: test · coil=multi-coil · anatomy=brain · ensemble=flip · acceleration=8× | IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI ReconstructionSource quoteL265: 0.9427 |
| 2024 | ADS proposed | SSIM | 91.26 | split: test · resolution=128×128 · acceleration=4× · sampling-fraction=25% | Active Diffusion SubsamplingSource quoteL251: While ADS appears to outperform fixed-mask baselines on MNIST, CelebA, and fastMRI, it is interesting to note that the relative improvement offered by ADS is less pronounced in the case of fastMRI. For line-based image subsampling on MNIST with 25% samples, ADS achieves a 50% reduction in reconstruction error versus a fixed-mask approach (MAE = 0.019 vs 0.037), whereas with line-based \kappa-space subsampling for fastMRI with 25% samples, ADS achieves only a 12% relative improvement (SSIM = 91.26 vs 90.13). We find that the size of this performance gap between fixed and active mask design strategies can be explained by examining the distribution of masks designed by ADS on each task (See Appendix \ref{appendix:mask-distributions}). Indeed, the masks designed for fastMRI are very similar, whereas those designed for MNIST typically differ depending on the sample. When mask designs are similar, then fixed masks will perform similarly to actively designed masks. This is in part a feature of the data distribution -- for example, most information in \kappa-space is contained in the center, at lower frequencies. Tasks in which one might expect significantly better performance from ADS are therefore those in which optimal masks will be highly sample-dependent. |
| 2024 | Deform-Mamba (Our) proposed | SSIM | 0.7194 | split: test · scale=4× | Deform-Mamba Network for MRI Super-ResolutionSource quoteL180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965 |
| 2024 | HQS (Cheb preconditioner) proposed | SSIM | 0.902 | acceleration-factor=16 | Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI ReconstructionSource quoteL185: HQS │ 34.521 │ 33.251 │ 0.917 │ 0.902 |
| 2024 | TC-KANRecon proposed | SSIM | 0.817 | acceleration-factor=4 | TC-KANRecon: High-Quality and Accelerated MRI Reconstruction via Adaptive KAN Mechanisms and Intelligent Feature ScalingSource quoteL209: TC-KANRecon (Ours) │ 30.50 │ 29.16 │ 27.93 │ 26.83 │ 0.817 │ 0.691 │ 0.624 │ 0.593 │ 0.0211 │ 0.0273 │ 0.0309 │ 0.0371 |
| 2024 | DIRCN [28] baseline | SSIM | 0.9455 | split: test · coil=multi-coil · anatomy=brain · acceleration=8× | IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI ReconstructionSource quoteL262: 0.9455 |
| 2024 | E2E-VarNet [34] baseline | SSIM | 0.9426 | split: test · coil=multi-coil · anatomy=brain · acceleration=8× | IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI ReconstructionSource quoteL268: 0.9426 |
| 2024 | XPDNet [31] baseline | SSIM | 0.9408 | split: test · coil=multi-coil · anatomy=brain · acceleration=8× | IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI ReconstructionSource quoteL271: 0.9408 |
| 2024 | HQS-Net [41] baseline | SSIM | 0.9400 | split: test · coil=multi-coil · anatomy=brain · acceleration=8× | IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI ReconstructionSource quoteL274: 0.9400 |
| 2024 | U-Net [46] baseline | SSIM | 0.9282 | split: test · coil=multi-coil · anatomy=brain · acceleration=8× | IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI ReconstructionSource quoteL277: 0.9282 |
| 2024 | Fixed-mask DPS baseline | SSIM | 90.13 | split: test · resolution=128×128 · acceleration=4× · sampling-fraction=25% | Active Diffusion SubsamplingSource quoteL251: While ADS appears to outperform fixed-mask baselines on MNIST, CelebA, and fastMRI, it is interesting to note that the relative improvement offered by ADS is less pronounced in the case of fastMRI. For line-based image subsampling on MNIST with 25% samples, ADS achieves a 50% reduction in reconstruction error versus a fixed-mask approach (MAE = 0.019 vs 0.037), whereas with line-based \kappa-space subsampling for fastMRI with 25% samples, ADS achieves only a 12% relative improvement (SSIM = 91.26 vs 90.13). We find that the size of this performance gap between fixed and active mask design strategies can be explained by examining the distribution of masks designed by ADS on each task (See Appendix \ref{appendix:mask-distributions}). Indeed, the masks designed for fastMRI are very similar, whereas those designed for MNIST typically differ depending on the sample. When mask designs are similar, then fixed masks will perform similarly to actively designed masks. This is in part a feature of the data distribution -- for example, most information in \kappa-space is contained in the center, at lower frequencies. Tasks in which one might expect significantly better performance from ADS are therefore those in which optimal masks will be highly sample-dependent. |
| 2024 | T (2)Net baseline | SSIM | 0.6244 | split: test · scale=4× | Deform-Mamba Network for MRI Super-ResolutionSource quoteL178: T (2)Net │ 30.56 │ 0.6244 │ 29.73 │ 0.8773 |
| 2024 | NCPDNET baseline | SSIM | 0.916 | acceleration-factor=16 · training-acceleration-factor=4 | Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI ReconstructionSource quoteL201: NCPDNET │ 37.765 │ 29.912 │ 0.977 │ 0.916 |
| 2023 | U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard slice | SSIM | 0.902 | split: test · subset=PDFS knee · test-acceleration=4-fold · training-acceleration=2-, 4-, 8-, and 16-fold | Robustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training DataSource quoteL324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912 |
| 2023 | U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard slice | SSIM | 0.912 | split: test · subset=PDFS knee · test-acceleration=3-fold · training-acceleration=2-, 4-, 8-, and 16-fold | Robustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training DataSource quoteL324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912 |
| 2023 | U-net trained on 4-fold acceleration data baseline non-standard slice | SSIM | 0.903 | split: test · subset=PDFS knee · test-acceleration=4-fold · training-acceleration=4-fold | Robustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training DataSource quoteL321: 4-fold │ --- │ 0.903 │ --- │ --- │ 0.899 |
| 2023 | U-net trained on 2-fold acceleration data baseline non-standard slice | SSIM | 0.906 | split: test · subset=PDFS knee · test-acceleration=3-fold · training-acceleration=2-fold | Robustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training DataSource quoteL320: 2-fold │ 0.945 │ --- │ --- │ --- │ 0.906 |
| 2023 | DDPM (Xie et al.) baseline | SSIM | 0.905 | contrast=proton-density · acceleration-factor=4 | A survey of emerging applications of diffusion probabilistic models in MRISource quoteL619: \cite{xie2022measurement} │ DDPM │ 36.69 │ 0.905 |
| 2023 | CNN (Ronneberger et al.) baseline | SSIM | 0.834 | contrast=proton-density · acceleration-factor=4 | A survey of emerging applications of diffusion probabilistic models in MRISource quoteL618: \cite{ronneberger2015u} │ CNN │ 34.04\tnote{a} │ 0.834\tnote{a} |
| 2022 | TITLE proposed | averaged SSIM | 0.6745 | coil=single-coil · anatomy=knee · reconstruction=learning-free IFT | Active Phase-Encode Selection for Slice-Specific Fast MR Scanning Using a Transformer-Based Deep Reinforcement Learning FrameworkSource quoteL898: The top part of Table 2 gives the performances of different methods where the images are reconstructed from the selected phases (corresponding incomplete K-space matrices) by learning-free IFT. The averaged SSIM of Random, Zhang, Pineda, and proposed TITLE methods is 0.6203, 0.6315, 0.6411, and 0.6745, respectively. Figure 5 (a) shows several examples of reconstructed images. The proposed method achieves the largest SSIM. SSIM is the most important criterion because of its consistence with eyes of human being. The averaged PSNR of Random, Zhang, Pineda, and TITLE methods is 27.10, 27.55, |
| 2022 | TITLE proposed | SSIM | 0.8163 | coil=single-coil · anatomy=knee · reconstruction=UNet | Active Phase-Encode Selection for Slice-Specific Fast MR Scanning Using a Transformer-Based Deep Reinforcement Learning FrameworkSource quoteL905: NMSE when the UNets converge are given in the bottom part of Table 2. Specifically, the SSIM of the Radom, Zhang, Pineda, and the proposed methods are 0.7962, 0.8020, 0.8113, and 0.8163, respectively. The proposed method achieves the largest SSIM. |
| 2022 | Pineda baseline | averaged SSIM | 0.6411 | coil=single-coil · anatomy=knee · reconstruction=learning-free IFT | Active Phase-Encode Selection for Slice-Specific Fast MR Scanning Using a Transformer-Based Deep Reinforcement Learning FrameworkSource quoteL898: The top part of Table 2 gives the performances of different methods where the images are reconstructed from the selected phases (corresponding incomplete K-space matrices) by learning-free IFT. The averaged SSIM of Random, Zhang, Pineda, and proposed TITLE methods is 0.6203, 0.6315, 0.6411, and 0.6745, respectively. Figure 5 (a) shows several examples of reconstructed images. The proposed method achieves the largest SSIM. SSIM is the most important criterion because of its consistence with eyes of human being. The averaged PSNR of Random, Zhang, Pineda, and TITLE methods is 27.10, 27.55, |
| 2022 | Pineda baseline | SSIM | 0.8113 | coil=single-coil · anatomy=knee · reconstruction=UNet | Active Phase-Encode Selection for Slice-Specific Fast MR Scanning Using a Transformer-Based Deep Reinforcement Learning FrameworkSource quoteL905: NMSE when the UNets converge are given in the bottom part of Table 2. Specifically, the SSIM of the Radom, Zhang, Pineda, and the proposed methods are 0.7962, 0.8020, 0.8113, and 0.8163, respectively. The proposed method achieves the largest SSIM. |
| 2021 | DONet proposed non-standard slice | SSIM | 0.856 | split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniform | DONet: Dual-Octave Network for Fast MR Image ReconstructionSource quoteL274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data. |
| 2021 | MINet proposed | SSIM | 0.709 | scale=2× · evaluation=average score · contrast-setting=HR T1WI auxiliary to restore LR T2WI | Multi-Contrast MRI Super-Resolution via a Multi-Stage Integration NetworkSource quoteL109: MINet │ {\color{red}31.769} │ {\color{red}0.709} │ {\color{red}29.819} │ {\color{red}0.601} │ {\color{red}40.549} │ {\color{red}0.983} │ {\color{red}35.032} │ {\color{red}0.948} │ {\color{red}37.997} │ {\color{red}0.980} │ {\color{red}34.219} │ {\color{red}0.956} |
| 2021 | PDNet w DC proposed | SSIM | 0.7327 | split: val · coil=single-coil · coverage=both contrasts · trajectory=radial · acceleration=4 | Density Compensated Unrolled Networks for Non-Cartesian MRI ReconstructionSource quoteL174: PDNet w DC │ 32.66 / 0.7327 │ 33.08 / 0.7534 │ 156k |
| 2021 | MRAugment with E2E-VarNet proposed | reconstruction SSIM | 0.9049 | subset=2% of training data · scanner-transfer=3T to 3T | Data augmentation for deep learning based accelerated MRI reconstruction with limited dataSource quoteL293: 3T \rightarrow 3T │ 0.8646 │ 0.9049 |
| 2021 | MRAugment with E2E-VarNet proposed | reconstruction SSIM | 0.8913 | subset=2% of training data · scanner-transfer=1.5T to 3T | Data augmentation for deep learning based accelerated MRI reconstruction with limited dataSource quoteL295: 1.5T \rightarrow 3T │ 0.8174 │ 0.8913 |
| 2021 | A-DPS (proposed) proposed | SSIM | 0.654 | split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 | Active Deep Probabilistic SubsamplingSource quoteL295: 0.654 different in that case. Whereas in the previous experiment |
| 2021 | E2E-VarNet (no DA) ablation | reconstruction SSIM | 0.8646 | subset=2% of training data · scanner-transfer=3T to 3T | Data augmentation for deep learning based accelerated MRI reconstruction with limited dataSource quoteL293: 3T \rightarrow 3T │ 0.8646 │ 0.9049 |
| 2021 | E2E-VarNet (no DA) ablation | reconstruction SSIM | 0.8174 | subset=2% of training data · scanner-transfer=1.5T to 3T | Data augmentation for deep learning based accelerated MRI reconstruction with limited dataSource quoteL295: 1.5T \rightarrow 3T │ 0.8174 │ 0.8913 |
| 2021 | ComplexMRI baseline non-standard slice | SSIM | 0.829 | split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniform | DONet: Dual-Octave Network for Fast MR Image ReconstructionSource quoteL274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data. |
| 2021 | Center undersampling pattern baseline | SSIM | 0.693 | acceleration=×4 · reconstruction=zero-filled | Optimal MRI Undersampling Patterns for Ultimate Benefit of Medical Vision TasksSource quoteL285: Center │ 0.693 │ 26.850 │ 0.029 │ 0.635 │ 20.969 │ 0.263 |
| 2021 | DPS baseline | SSIM | 0.650 | split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 | Active Deep Probabilistic SubsamplingSource quoteL291: 0.650 |
| 2020 | ReconODE-LT-Euler proposed | SSIM | 0.7194 | split: val · subset=single-coil knee · undersampling=4x | MRI Image Reconstruction via Learning Optimization Using Neural ODEsSource quoteL141: ReconODE-LT-Euler │ 0.03M │ 31.86 │ 29.11 │ 0.7194 │ 0.6363 |
| 2020 | Proposed pixel-wise RL MRI reconstruction (Ours, with data consistency) proposed non-standard slice | SSIM | 0.88 | split: val · coil=single-coil · subset=first 1,000 validation images · masking=random 40% | MRI Reconstruction with Interpretable Pixel-Wise Operations Using Reinforcement LearningSource quoteL340: 0.88 the images are of various sizes, we crop the 320x320 center region and then do the down-sampling. In addition, images are normalized and rescaled into range [0, 255]. |
| 2020 | E2E-VN proposed | SSIM | 0.930 | split: test · anatomy=knee · acceleration=4× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL197: E2E-VN │ 0.930 │ 0.005 │ 40 │ 0.890 │ 0.009 │ 37 |
| 2020 | E2E-VN proposed | SSIM | 0.890 | split: test · anatomy=knee · acceleration=8× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL197: E2E-VN │ 0.930 │ 0.005 │ 40 │ 0.890 │ 0.009 │ 37 |
| 2020 | E2E-VN proposed | SSIM | 0.959 | split: test · anatomy=brain · acceleration=4× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL202: Brain │ E2E-VN │ 0.959 │ 0.004 │ 41 │ 0.943 │ 0.008 │ 38 |
| 2020 | E2E-VN proposed | SSIM | 0.943 | split: test · anatomy=brain · acceleration=8× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL202: Brain │ E2E-VN │ 0.959 │ 0.004 │ 41 │ 0.943 │ 0.008 │ 38 |
| 2020 | Philips & LUMC (challenge submission) baseline non-standard slice | SSIM | 0.901 | coil=multi-coil · acceleration=R=8 | Advancing machine learning for MR image reconstruction with an open competition: Overview of the 2019 fastMRI challengeSource quoteL149: Philips \ │ LUMC │ 1 │ 1.286 │ 0.901 │ 0.0086 │ 37.437 |
| 2020 | AImsterdam (challenge submission) baseline non-standard slice | SSIM | 0.754 | coil=single-coil · acceleration=R=4 | Advancing machine learning for MR image reconstruction with an open competition: Overview of the 2019 fastMRI challengeSource quoteL161: AImsterdam │ 1 │ 1.286 │ 0.754 │ 0.031 │ 32.549 |
| 2020 | UNet baseline | SSIM | 0.7177 | split: val · subset=single-coil knee · undersampling=4x | MRI Image Reconstruction via Learning Optimization Using Neural ODEsSource quoteL132: UNet │ 3.35M │ 31.84 │ 29.87 │ 0.7177 │ 0.6514 |
| 2020 | SubtleMR baseline | SSIM | 0.888 | split: test · anatomy=knee · acceleration=8× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL198: SubtleMR │ 0.929 │ 0.005 │ 40 │ 0.888 │ 0.009 │ 37 |
| 2020 | U-Net baseline | SSIM | 0.915 | split: test · anatomy=brain · acceleration=8× | End-to-End Variational Networks for Accelerated MRI ReconstructionSource quoteL203: U-Net │ 0.945 │ 0.011 │ 38 │ 0.915 │ 0.023 │ 35 |
| 2019 | Proposed self-supervised learning (SSL; U-net inverse operator) proposed | SSIM | 0.47 | split: val · acceleration=×8 | Self-supervised learning of inverse problem solvers in medical imagingSource quoteL131: SSIM │ 0.40 │ N/A │ 0.47 │ 0.604 |
| 2019 | Offset 0 sampling proposed | SSIM | 0.924 | split: val · sampling=Offset 0 · coil-setup=multi-coil · acceleration=4x · low-frequency-lines=16 | Offset Masking Improves Deep Learning based Accelerated MRI ReconstructionsSource quoteL261: knee MRI reconstruction, showing an improvement in SSIM from 0.924 |
| 2019 | Offset 1 sampling proposed | SSIM | 0.926 | split: val · sampling=Offset 1 · coil-setup=multi-coil · acceleration=4x · low-frequency-lines=16 | Offset Masking Improves Deep Learning based Accelerated MRI ReconstructionsSource quoteL262: to 0.926.} |
| 2019 | unpaired WGAN proposed | SSIM | 0.822 | split: test · unpaired · training=7 input subjects, 6 disjoint label subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersampling | Wasserstein GANs for MR Imaging: From Paired to Unpaired TrainingSource quoteL217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831 |
| 2019 | WGAN+ℓ₁ proposed | SSIM | 0.824 | split: test · paired · training=6 subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersampling | Wasserstein GANs for MR Imaging: From Paired to Unpaired TrainingSource quoteL217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831 |
| 2019 | Supervised restoration model baseline | SSIM | 0.604 | split: val · acceleration=×8 | Self-supervised learning of inverse problem solvers in medical imagingSource quoteL131: SSIM │ 0.40 │ N/A │ 0.47 │ 0.604 |
| 2019 | ℓ₁-net baseline | SSIM | 0.828 | split: test · paired · training=6 subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersampling | Wasserstein GANs for MR Imaging: From Paired to Unpaired TrainingSource quoteL217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831 |