fastMRI
86 papers · 287 extracted observations · mri reconstruction · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CRR-NN SOTA frontier | 40.95 | 2023-01-01 | coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-fold · FastMRI knee PD test images; 2-fold Cartesian undersampling, measurement noise standa… | A Neural-Network-Based Convex Regularizer for Inverse ProblemsSource quoteCRR-NN │ {\bf 40.95} │ 38.91 │ {\bf 0.961} │ 0.934 │ 33.99 │ 33.75 │ 0.880 │ 0.831 |
| 2 | Joint-ICNet SOTA frontier (+3 variants) | 40.7 | 2021-01-01 | reduction-factor=4 · Table 2 model ablation; reduction factor R=4. Paper setup uses multi-coil k-space ret… | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quote40.7 |
| 3 | DEAL (+1 variant) | 36.59 | 2025-01-01 | coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-fold · 4-fold single-coil setup; centered 320×320 patches from 50 test images; additive whit… | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteDEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32 |
| 4 | SAFI (+1 variant) | 36.43 | 2024-07-01 | subset=50 test images · sequence=PD · resolution=320x320 · acceleration=4-fold · coil-setting=single-coil · patch-resolution=320×320 · PD knee images without fat suppression; denoising-trained model, with λ tuned on 10 v… | Iteratively Refined Image Reconstruction with Learned Attentive RegularizersSource quoteSAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860 |
| 5 | MFoE | 35.4 | 2025-08-01 | noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4 · PD data; acceleration factor 4 and center fraction 0.08; Gaussian measurement noise w… | Multivariate Fields of ExpertsSource quoteMFoE │ 35.40 │ 34.21 │ 30.26 │ 31.20 |
| 6 | aSeqDIP | 34.08 | 2024-01-01 | undersampling=4× · averaged-scans=20 · Average over 20 MRI scans from the fastMRI testing set at 4× undersampling; no labele… | Image Reconstruction Via Autoencoding Sequential Deep Image PriorSource quote34.08 |
| 7 | Deform-Mamba (Our) | 32.11 | 2024-07-01 | scale=4× · 4× upsampling; held-out test split (45 subjects); low-resolution inputs synthesized i… | Deform-Mamba Network for MRI Super-ResolutionSource quoteOur │ 32.11 │ 0.7194 │ 30.60 │ 0.8965 |
| 8 | Deep Equilibrium (Grad) | 32.01 | 2021-02-01 | roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8× · Test-set mean; 8× accelerated virtual single-coil Cartesian MRI with complex AWGN sta… | Deep Equilibrium Architectures for Inverse Problems in ImagingSource quotePSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38 |
| 9 | Interleaved (self-supervised loss added during training) | 31.55 | 2025-01-01 | method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brain · 6x-accelerated MRI; trained on the FastMRI brain dataset and tested on knees. | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteInterleaved │ 31.55 │ .7910 |
| 10 | LLS (\lambda=10 (-6)) | 31.54 | 2024-01-01 | mask=acceleration=4, center_fraction=0.08 · coils=single-coil · lambda=1e-6 · noise_sigma=0.01 · test_images=99 · PnP-FBS reconstruction; measurement noise \sigma-\mathbf n=0.01; mask (M_{\text{acc}}… | Improving Lipschitz-Constrained Neural Networks by Learning Activation FunctionsSource quoteLLS │ 31.54 │ 0.7924 │ 28.04 │ 0.7108 |
| 11 | A-DPS (proposed) | 30.2 | 2021-01-01 | resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 · Table 2: acceleration factor 8; scenario-30L (30 k-space lines closest to DC, with 16… | Active Deep Probabilistic SubsamplingSource quote30.2 |
| 12 | Distilled (on-policy privileged information distillation) (+2 variants) | 27.86 | 2026-05-01 | contrast=T1 · acceleration=R=32 · undersampling=Gaussian-VD · R=32; Gaussian-VD undersampling; T1 contrast. | Next-Acceleration-Scale Prediction for Autoregressive MRI ReconstructionSource quoteDistilled │ 27.86 │ 22.29 │ 24.08 │ 0.81 │ 0.70 │ 0.67 │ 0.148 │ 0.161 │ 0.162 |
Showing 8 of 8 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2021 | PDNet w DC proposed | SSIM | 0.7327 | split: val · coil=single-coil · coverage=both contrasts · trajectory=radial · acceleration=4 | Density Compensated Unrolled Networks for Non-Cartesian MRI ReconstructionSource quoteL174: PDNet w DC │ 32.66 / 0.7327 │ 33.08 / 0.7534 │ 156k |
| 2020 | ReconODE-LT-Euler proposed | SSIM | 0.7194 | split: val · subset=single-coil knee · undersampling=4x | MRI Image Reconstruction via Learning Optimization Using Neural ODEsSource quoteL141: ReconODE-LT-Euler │ 0.03M │ 31.86 │ 29.11 │ 0.7194 │ 0.6363 |
| 2020 | Proposed pixel-wise RL MRI reconstruction (Ours, with data consistency) proposed non-standard slice | SSIM | 0.88 | split: val · coil=single-coil · subset=first 1,000 validation images · masking=random 40% | MRI Reconstruction with Interpretable Pixel-Wise Operations Using Reinforcement LearningSource quoteL340: 0.88 the images are of various sizes, we crop the 320x320 center region and then do the down-sampling. In addition, images are normalized and rescaled into range [0, 255]. |
| 2020 | UNet baseline | SSIM | 0.7177 | split: val · subset=single-coil knee · undersampling=4x | MRI Image Reconstruction via Learning Optimization Using Neural ODEsSource quoteL132: UNet │ 3.35M │ 31.84 │ 29.87 │ 0.7177 │ 0.6514 |
| 2019 | Proposed self-supervised learning (SSL; U-net inverse operator) proposed | SSIM | 0.47 | split: val · acceleration=×8 | Self-supervised learning of inverse problem solvers in medical imagingSource quoteL131: SSIM │ 0.40 │ N/A │ 0.47 │ 0.604 |
| 2019 | Offset 0 sampling proposed | SSIM | 0.924 | split: val · sampling=Offset 0 · coil-setup=multi-coil · acceleration=4x · low-frequency-lines=16 | Offset Masking Improves Deep Learning based Accelerated MRI ReconstructionsSource quoteL261: knee MRI reconstruction, showing an improvement in SSIM from 0.924 |
| 2019 | Offset 1 sampling proposed | SSIM | 0.926 | split: val · sampling=Offset 1 · coil-setup=multi-coil · acceleration=4x · low-frequency-lines=16 | Offset Masking Improves Deep Learning based Accelerated MRI ReconstructionsSource quoteL262: to 0.926.} |
| 2019 | Supervised restoration model baseline | SSIM | 0.604 | split: val · acceleration=×8 | Self-supervised learning of inverse problem solvers in medical imagingSource quoteL131: SSIM │ 0.40 │ N/A │ 0.47 │ 0.604 |