fastMRI

86 papers · 287 extracted observations · mri reconstruction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

22.829.335.842.3202120242026A-DPS (proposed): 30.2 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 35.8 (2021)Joint-ICNet: 37.3 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 39.4 (2021)Joint-ICNet: 40.7 (2021)Deep Equilibrium (Grad): 32.01 (2021)CRR-NN: 40.95 (2023)LLS (\lambda=10 (-6)): 31.54 (2024)aSeqDIP: 34.08 (2024)Deform-Mamba (Our): 32.11 (2024)SAFI: 36.06 (2024)SAFI: 36.43 (2024)Interleaved (self-supervised loss added during training): 31.55 (2025)DEAL: 36.21 (2025)DEAL: 36.59 (2025)MFoE: 35.4 (2025)Distilled (on-policy privileged information distillation): 24.11 (2026)Distilled (on-policy privileged information distillation): 26.0 (2026)Distilled (on-policy privileged information distillation): 27.86 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 33 of 33 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026EvoML proposedSSIM0.9498split: test · supervisedValidation-Gated ML Pipeline Synthesis with Expert-Grounded Self-Evolving Skills
Source quote
L975: The margin is largest on the harder tasks, reaching 0.9498
2025Interleaved (self-supervised loss added during training) proposedSSIM.7910split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brainBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L283: Interleaved │ 31.55 │ .7910
2025SelfDB proposedSSIM0.882split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L137: SelfDB │ 0.108 │ 0.882 │ 0.036
2025Supervised learning baseline non-standard sliceSSIM.8141split: test · anatomy=knee · training=supervised with oracle ground truth · acceleration=6xBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L414: (Supervised) │ (32.68) │ (.8141)
2025C-Ambient-DDM baselineSSIM0.833split: test · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L136: C-Ambient-DDM │ 0.113 │ 0.833 │ 0.056
2025ADS baselinemean SSIM91.26split: test · subset=knee · k-space-subsampling=25%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L227: ADS \citep{nolan2024} │ 91.26
2024IR-FRestormerF proposedSSIM0.9427split: test · coil=multi-coil · anatomy=brain · ensemble=flip · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L265: 0.9427
2024ADS proposedSSIM91.26split: test · resolution=128×128 · acceleration=4× · sampling-fraction=25%Active Diffusion Subsampling
Source quote
L251: While ADS appears to outperform fixed-mask baselines on MNIST, CelebA, and fastMRI, it is interesting to note that the relative improvement offered by ADS is less pronounced in the case of fastMRI. For line-based image subsampling on MNIST with 25% samples, ADS achieves a 50% reduction in reconstruction error versus a fixed-mask approach (MAE = 0.019 vs 0.037), whereas with line-based \kappa-space subsampling for fastMRI with 25% samples, ADS achieves only a 12% relative improvement (SSIM = 91.26 vs 90.13). We find that the size of this performance gap between fixed and active mask design strategies can be explained by examining the distribution of masks designed by ADS on each task (See Appendix \ref{appendix:mask-distributions}). Indeed, the masks designed for fastMRI are very similar, whereas those designed for MNIST typically differ depending on the sample. When mask designs are similar, then fixed masks will perform similarly to actively designed masks. This is in part a feature of the data distribution -- for example, most information in \kappa-space is contained in the center, at lower frequencies. Tasks in which one might expect significantly better performance from ADS are therefore those in which optimal masks will be highly sample-dependent.
2024Deform-Mamba (Our) proposedSSIM0.7194split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965
2024DIRCN [28] baselineSSIM0.9455split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L262: 0.9455
2024E2E-VarNet [34] baselineSSIM0.9426split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L268: 0.9426
2024XPDNet [31] baselineSSIM0.9408split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L271: 0.9408
2024HQS-Net [41] baselineSSIM0.9400split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L274: 0.9400
2024U-Net [46] baselineSSIM0.9282split: test · coil=multi-coil · anatomy=brain · acceleration=8×IR-FRestormer: Iterative Refinement with Fourier-Based Restormer for Accelerated MRI Reconstruction
Source quote
L277: 0.9282
2024Fixed-mask DPS baselineSSIM90.13split: test · resolution=128×128 · acceleration=4× · sampling-fraction=25%Active Diffusion Subsampling
Source quote
L251: While ADS appears to outperform fixed-mask baselines on MNIST, CelebA, and fastMRI, it is interesting to note that the relative improvement offered by ADS is less pronounced in the case of fastMRI. For line-based image subsampling on MNIST with 25% samples, ADS achieves a 50% reduction in reconstruction error versus a fixed-mask approach (MAE = 0.019 vs 0.037), whereas with line-based \kappa-space subsampling for fastMRI with 25% samples, ADS achieves only a 12% relative improvement (SSIM = 91.26 vs 90.13). We find that the size of this performance gap between fixed and active mask design strategies can be explained by examining the distribution of masks designed by ADS on each task (See Appendix \ref{appendix:mask-distributions}). Indeed, the masks designed for fastMRI are very similar, whereas those designed for MNIST typically differ depending on the sample. When mask designs are similar, then fixed masks will perform similarly to actively designed masks. This is in part a feature of the data distribution -- for example, most information in \kappa-space is contained in the center, at lower frequencies. Tasks in which one might expect significantly better performance from ADS are therefore those in which optimal masks will be highly sample-dependent.
2024T (2)Net baselineSSIM0.6244split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L178: T (2)Net │ 30.56 │ 0.6244 │ 29.73 │ 0.8773
2023U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard sliceSSIM0.902split: test · subset=PDFS knee · test-acceleration=4-fold · training-acceleration=2-, 4-, 8-, and 16-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912
2023U-net trained on 2-, 4-, 8-, and 16-fold acceleration data proposed non-standard sliceSSIM0.912split: test · subset=PDFS knee · test-acceleration=3-fold · training-acceleration=2-, 4-, 8-, and 16-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L324: All of above │ 0.944 │ 0.902 │ 0.866 │ 0.829 │ 0.912
2023U-net trained on 4-fold acceleration data baseline non-standard sliceSSIM0.903split: test · subset=PDFS knee · test-acceleration=4-fold · training-acceleration=4-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L321: 4-fold │ --- │ 0.903 │ --- │ --- │ 0.899
2023U-net trained on 2-fold acceleration data baseline non-standard sliceSSIM0.906split: test · subset=PDFS knee · test-acceleration=3-fold · training-acceleration=2-foldRobustness of Deep Learning for Accelerated MRI: Benefits of Diverse Training Data
Source quote
L320: 2-fold │ 0.945 │ --- │ --- │ --- │ 0.906
2021DONet proposed non-standard sliceSSIM0.856split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniformDONet: Dual-Octave Network for Fast MR Image Reconstruction
Source quote
L274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data.
2021A-DPS (proposed) proposedSSIM0.654split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L295: 0.654 different in that case. Whereas in the previous experiment
2021ComplexMRI baseline non-standard sliceSSIM0.829split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniformDONet: Dual-Octave Network for Fast MR Image Reconstruction
Source quote
L274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data.
2021DPS baselineSSIM0.650split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L291: 0.650
2020E2E-VN proposedSSIM0.930split: test · anatomy=knee · acceleration=4×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L197: E2E-VN │ 0.930 │ 0.005 │ 40 │ 0.890 │ 0.009 │ 37
2020E2E-VN proposedSSIM0.890split: test · anatomy=knee · acceleration=8×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L197: E2E-VN │ 0.930 │ 0.005 │ 40 │ 0.890 │ 0.009 │ 37
2020E2E-VN proposedSSIM0.959split: test · anatomy=brain · acceleration=4×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L202: Brain │ E2E-VN │ 0.959 │ 0.004 │ 41 │ 0.943 │ 0.008 │ 38
2020E2E-VN proposedSSIM0.943split: test · anatomy=brain · acceleration=8×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L202: Brain │ E2E-VN │ 0.959 │ 0.004 │ 41 │ 0.943 │ 0.008 │ 38
2020SubtleMR baselineSSIM0.888split: test · anatomy=knee · acceleration=8×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L198: SubtleMR │ 0.929 │ 0.005 │ 40 │ 0.888 │ 0.009 │ 37
2020U-Net baselineSSIM0.915split: test · anatomy=brain · acceleration=8×End-to-End Variational Networks for Accelerated MRI Reconstruction
Source quote
L203: U-Net │ 0.945 │ 0.011 │ 38 │ 0.915 │ 0.023 │ 35
2019unpaired WGAN proposedSSIM0.822split: test · unpaired · training=7 input subjects, 6 disjoint label subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersamplingWasserstein GANs for MR Imaging: From Paired to Unpaired Training
Source quote
L217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831
2019WGAN+ℓ₁ proposedSSIM0.824split: test · paired · training=6 subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersamplingWasserstein GANs for MR Imaging: From Paired to Unpaired Training
Source quote
L217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831
2019ℓ₁-net baselineSSIM0.828split: test · paired · training=6 subjects · evaluation=center 272 × 216 region · resolution=272x216 · acceleration=10-fold undersamplingWasserstein GANs for MR Imaging: From Paired to Unpaired Training
Source quote
L217: SSIM │ 0.692 │ 0.822 │ 0.828 │ 0.824 │ 0.831