fastMRI
86 papers · 287 extracted observations · mri reconstruction · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CRR-NN SOTA frontier | 40.95 | 2023-01-01 | coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-fold · FastMRI knee PD test images; 2-fold Cartesian undersampling, measurement noise standa… | A Neural-Network-Based Convex Regularizer for Inverse ProblemsSource quoteCRR-NN │ {\bf 40.95} │ 38.91 │ {\bf 0.961} │ 0.934 │ 33.99 │ 33.75 │ 0.880 │ 0.831 |
| 2 | Joint-ICNet SOTA frontier (+3 variants) | 40.7 | 2021-01-01 | reduction-factor=4 · Table 2 model ablation; reduction factor R=4. Paper setup uses multi-coil k-space ret… | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quote40.7 |
| 3 | DEAL (+1 variant) | 36.59 | 2025-01-01 | coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-fold · 4-fold single-coil setup; centered 320×320 patches from 50 test images; additive whit… | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteDEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32 |
| 4 | SAFI (+1 variant) | 36.43 | 2024-07-01 | subset=50 test images · sequence=PD · resolution=320x320 · acceleration=4-fold · coil-setting=single-coil · patch-resolution=320×320 · PD knee images without fat suppression; denoising-trained model, with λ tuned on 10 v… | Iteratively Refined Image Reconstruction with Learned Attentive RegularizersSource quoteSAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860 |
| 5 | MFoE | 35.4 | 2025-08-01 | noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4 · PD data; acceleration factor 4 and center fraction 0.08; Gaussian measurement noise w… | Multivariate Fields of ExpertsSource quoteMFoE │ 35.40 │ 34.21 │ 30.26 │ 31.20 |
| 6 | aSeqDIP | 34.08 | 2024-01-01 | undersampling=4× · averaged-scans=20 · Average over 20 MRI scans from the fastMRI testing set at 4× undersampling; no labele… | Image Reconstruction Via Autoencoding Sequential Deep Image PriorSource quote34.08 |
| 7 | Deform-Mamba (Our) | 32.11 | 2024-07-01 | scale=4× · 4× upsampling; held-out test split (45 subjects); low-resolution inputs synthesized i… | Deform-Mamba Network for MRI Super-ResolutionSource quoteOur │ 32.11 │ 0.7194 │ 30.60 │ 0.8965 |
| 8 | Deep Equilibrium (Grad) | 32.01 | 2021-02-01 | roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8× · Test-set mean; 8× accelerated virtual single-coil Cartesian MRI with complex AWGN sta… | Deep Equilibrium Architectures for Inverse Problems in ImagingSource quotePSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38 |
| 9 | Interleaved (self-supervised loss added during training) | 31.55 | 2025-01-01 | method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brain · 6x-accelerated MRI; trained on the FastMRI brain dataset and tested on knees. | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteInterleaved │ 31.55 │ .7910 |
| 10 | LLS (\lambda=10 (-6)) | 31.54 | 2024-01-01 | mask=acceleration=4, center_fraction=0.08 · coils=single-coil · lambda=1e-6 · noise_sigma=0.01 · test_images=99 · PnP-FBS reconstruction; measurement noise \sigma-\mathbf n=0.01; mask (M_{\text{acc}}… | Improving Lipschitz-Constrained Neural Networks by Learning Activation FunctionsSource quoteLLS │ 31.54 │ 0.7924 │ 28.04 │ 0.7108 |
| 11 | A-DPS (proposed) | 30.2 | 2021-01-01 | resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 · Table 2: acceleration factor 8; scenario-30L (30 k-space lines closest to DC, with 16… | Active Deep Probabilistic SubsamplingSource quote30.2 |
| 12 | Distilled (on-policy privileged information distillation) (+2 variants) | 27.86 | 2026-05-01 | contrast=T1 · acceleration=R=32 · undersampling=Gaussian-VD · R=32; Gaussian-VD undersampling; T1 contrast. | Next-Acceleration-Scale Prediction for Autoregressive MRI ReconstructionSource quoteDistilled │ 27.86 │ 22.29 │ 24.08 │ 0.81 │ 0.70 │ 0.67 │ 0.148 │ 0.161 │ 0.162 |
Showing 25 of 25 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2024 | Nila (Nila-DC) proposed | PSNR | 37.08 | split: val · noise=none · acceleration=6× | Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRISource quoteL124: Nila (ours) │ \textcolor{red}{37.08} │ \textcolor{red}{95.74} │ \textcolor{red}{34.82} │ \textcolor{red}{94.21} │ \textcolor{red}{36.10} │ \textcolor{red}{94.34} │ \textcolor{red}{33.54} │ \textcolor{red}{91.55} │ \textcolor{red}{30.23} │ \textcolor{red}{91.59} │ \textcolor{red}{29.86} │ \textcolor{red}{90.06} |
| 2024 | Nila (Nila-DC) proposed | PSNR | 31.86 | split: val · noise=Gaussian σ=0.1 · acceleration=6× | Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRISource quoteL145: Nila (ours) │ \textcolor{red}{34.98} │ \textcolor{red}{93.96} │ \textcolor{red}{33.56} │ \textcolor{red}{92.49} │ \textcolor{red}{31.86} │ \textcolor{red}{90.38} │ \textcolor{red}{34.11} │ \textcolor{red}{91.53} │ \textcolor{red}{32.80} │ \textcolor{red}{89.59} │ \textcolor{red}{31.25} │ \textcolor{red}{87.15} |
| 2024 | CSGM baseline | PSNR | 35.04 | split: val · noise=none · acceleration=6× | Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRISource quoteL121: CSGM │ \textcolor{blue}{35.04} │ \textcolor{blue}{93.53} │ \textcolor{blue}{32.11} │ \textcolor{blue}{90.78} │ \textcolor{blue}{34.67} │ \textcolor{blue}{92.65} │ \textcolor{blue}{31.57} │ \textcolor{blue}{88.94} │ 26.73 │ 84.53 │ 25.63 │ 82.78 |
| 2024 | Spreco baseline | PSNR | 25.89 | split: val · noise=Gaussian σ=0.1 · acceleration=6× | Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRISource quoteL143: Spreco │ \textcolor{blue}{31.31} │ \textcolor{blue}{89.03} │ \textcolor{blue}{29.62} │ \textcolor{blue}{84.93} │ \textcolor{blue}{25.89} │ \textcolor{blue}{74.23} │ 31.32 │ \textcolor{blue}{88.03} │ \textcolor{blue}{29.58} │ \textcolor{blue}{83.88} │ \textcolor{blue}{26.41} │ 74.10 |
| 2023 | RED-diff proposed | PSNR | 37.1 dB | split: val · coil=multi-coil · subset=6 validation volumes · undersampling=1D equispaced, R=4 | A Variational Perspective on Solving Inverse Problems with Diffusion ModelsSource quoteL482: RED-diff │ 37.1 │ 33.2 │ 32.7 │ 0.114 |
| 2023 | Proposed joint non-linear inversion algorithm with diffusion prior proposed | PSNR | 34.34 | split: val · subset=8% ACL; 15 central slices · contrast=PD · sampling=4-fold Cartesian; swapped phase-encoding direction · resolution=320×320 reference center region | Joint Non-Linear MRI Inversion with Diffusion PriorsSource quoteL304: Cartesian\tnote{*} │ 4 │ 30.37 │ 28.65 │ 32.43 │ 30.88 │ 23.89 │ 29.68 │ 34.34 │ 32.88 |
| 2023 | Proposed joint non-linear inversion algorithm with diffusion prior proposed | PSNR | 31.55 | split: val · subset=15 central slices · contrast=PDFS · sampling=4-fold Gaussian · resolution=320×320 reference center region | Joint Non-Linear MRI Inversion with Diffusion PriorsSource quoteL305: Gaussian │ 4 │ 30.24 │ 27.68 │ 30.91 │ 30.90 │ 22.36 │ 27.35 │ 31.01 │ 31.55 |
| 2023 | Proposed joint non-linear inversion algorithm with diffusion prior proposed | PSNR | 31.78 | split: val · subset=15 central slices · contrast=PDFS · sampling=radial; 45 spokes; 11-fold acceleration · resolution=320×320 reference center region | Joint Non-Linear MRI Inversion with Diffusion PriorsSource quoteL306: Radial │ 11 │ 27.93 │ 26.70 │ 30.66 │ 30.70 │ 19.97 │ 25.55 │ 32.18 │ 31.78 |
| 2023 | CSGM baseline | PSNR | 36.3 dB | split: val · coil=multi-coil · subset=6 validation volumes · undersampling=1D equispaced, R=4 | A Variational Perspective on Solving Inverse Problems with Diffusion ModelsSource quoteL481: CSGM │ 36.3 │ 31.4 │ 31.8 │ 0.344 |
| 2023 | TV baseline (Charbonnier-smoothed TV regularizer) baseline | PSNR | 32.43 | split: val · subset=8% ACL; 15 central slices · contrast=PD · sampling=4-fold Cartesian; swapped phase-encoding direction · resolution=320×320 reference center region | Joint Non-Linear MRI Inversion with Diffusion PriorsSource quoteL304: Cartesian\tnote{*} │ 4 │ 30.37 │ 28.65 │ 32.43 │ 30.88 │ 23.89 │ 29.68 │ 34.34 │ 32.88 |
| 2023 | TV baseline (Charbonnier-smoothed TV regularizer) baseline | PSNR | 30.90 | split: val · subset=15 central slices · contrast=PDFS · sampling=4-fold Gaussian · resolution=320×320 reference center region | Joint Non-Linear MRI Inversion with Diffusion PriorsSource quoteL305: Gaussian │ 4 │ 30.24 │ 27.68 │ 30.91 │ 30.90 │ 22.36 │ 27.35 │ 31.01 │ 31.55 |
| 2023 | TV baseline (Charbonnier-smoothed TV regularizer) baseline | PSNR | 30.70 | split: val · subset=15 central slices · contrast=PDFS · sampling=radial; 45 spokes; 11-fold acceleration · resolution=320×320 reference center region | Joint Non-Linear MRI Inversion with Diffusion PriorsSource quoteL306: Radial │ 11 │ 27.93 │ 26.70 │ 30.66 │ 30.70 │ 19.97 │ 25.55 │ 32.18 │ 31.78 |
| 2021 | PDNet w DC proposed | PSNR | 32.66 | split: val · coil=single-coil · coverage=both contrasts · trajectory=radial · acceleration=4 | Density Compensated Unrolled Networks for Non-Cartesian MRI ReconstructionSource quoteL174: PDNet w DC │ 32.66 / 0.7327 │ 33.08 / 0.7534 │ 156k |
| 2021 | U-net on Adjoint + DC baseline | PSNR | 32.26 | split: val · coil=single-coil · model=U-net · coverage=both contrasts · trajectory=radial · acceleration=4 | Density Compensated Unrolled Networks for Non-Cartesian MRI ReconstructionSource quoteL173: U-net on Adjoint + DC │ 32.26 / 0.7224 │ 32.82 / 0.7460 │ 481k |
| 2020 | ReconODE-LT-Euler proposed | PSNR | 31.86 | split: val · subset=single-coil knee · undersampling=4x | MRI Image Reconstruction via Learning Optimization Using Neural ODEsSource quoteL141: ReconODE-LT-Euler │ 0.03M │ 31.86 │ 29.11 │ 0.7194 │ 0.6363 |
| 2020 | Proposed pixel-wise RL MRI reconstruction (Ours, with data consistency) proposed non-standard slice | PSNR | 30.3 | split: val · coil=single-coil · subset=first 1,000 validation images · masking=random 40% | MRI Reconstruction with Interpretable Pixel-Wise Operations Using Reinforcement LearningSource quoteL339: 30.3 |
| 2020 | UNet baseline | PSNR | 31.84 | split: val · subset=single-coil knee · undersampling=4x | MRI Image Reconstruction via Learning Optimization Using Neural ODEsSource quoteL132: UNet │ 3.35M │ 31.84 │ 29.87 │ 0.7177 │ 0.6514 |
| 2019 | Proposed self-supervised learning (SSL; U-net inverse operator) proposed | PSNR | 22.86 dB | split: val · acceleration=×8 | Self-supervised learning of inverse problem solvers in medical imagingSource quoteL130: PSNR │ 13.74 │ N/A │ 22.86 │ 26.72 |
| 2019 | PC-RNN (multi-coil) proposed | PSNR | 39.0 | split: val · coil=multi-coil · acceleration=4x | Pyramid Convolutional RNN for MRI ReconstructionSource quoteL134: Multi-coil │ PC-RNN │ 39.0 │ 36.5 │ 0.914 │ 0.884 |
| 2019 | PC-RNN (multi-coil) proposed | PSNR | 36.5 | split: val · coil=multi-coil · acceleration=8x | Pyramid Convolutional RNN for MRI ReconstructionSource quoteL134: Multi-coil │ PC-RNN │ 39.0 │ 36.5 │ 0.914 │ 0.884 |
| 2019 | PC-RNN (single-coil) proposed | PSNR | 31.3 | split: val · coil=single-coil · acceleration=8x | Pyramid Convolutional RNN for MRI ReconstructionSource quoteL131: Single-coil │ PC-RNN │ 32.8 │ 31.3 │ 0.743 │ 0.682 |
| 2019 | Supervised restoration model baseline | PSNR | 26.72 dB | split: val · acceleration=×8 | Self-supervised learning of inverse problem solvers in medical imagingSource quoteL130: PSNR │ 13.74 │ N/A │ 22.86 │ 26.72 |
| 2019 | U-Net (multi-coil) baseline | PSNR | 36.7 | split: val · coil=multi-coil · acceleration=4x | Pyramid Convolutional RNN for MRI ReconstructionSource quoteL133: Multi-coil │ U-Net │ 36.7 │ 33.7 │ 0.894 │ 0.852 |
| 2019 | U-Net (multi-coil) baseline | PSNR | 33.7 | split: val · coil=multi-coil · acceleration=8x | Pyramid Convolutional RNN for MRI ReconstructionSource quoteL133: Multi-coil │ U-Net │ 36.7 │ 33.7 │ 0.894 │ 0.852 |
| 2019 | U-Net (single-coil) baseline | PSNR | 29.9 | split: val · coil=single-coil · acceleration=8x | Pyramid Convolutional RNN for MRI ReconstructionSource quoteL130: Single-coil │ U-Net │ 31.9 │ 29.9 │ 0.723 │ 0.654 |