fastMRI

86 papers · 287 extracted observations · mri reconstruction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

22.829.335.842.3202120242026A-DPS (proposed): 30.2 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 35.8 (2021)Joint-ICNet: 37.3 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 39.4 (2021)Joint-ICNet: 40.7 (2021)Deep Equilibrium (Grad): 32.01 (2021)CRR-NN: 40.95 (2023)LLS (\lambda=10 (-6)): 31.54 (2024)aSeqDIP: 34.08 (2024)Deform-Mamba (Our): 32.11 (2024)SAFI: 36.06 (2024)SAFI: 36.43 (2024)Interleaved (self-supervised loss added during training): 31.55 (2025)DEAL: 36.21 (2025)DEAL: 36.59 (2025)MFoE: 35.4 (2025)Distilled (on-policy privileged information distillation): 24.11 (2026)Distilled (on-policy privileged information distillation): 26.0 (2026)Distilled (on-policy privileged information distillation): 27.86 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 62 of 62 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Distilled (on-policy privileged information distillation) proposedPSNR27.86split: test · contrast=T1 · acceleration=R=32 · undersampling=Gaussian-VDNext-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction
Source quote
L344: Distilled │ 27.86 │ 22.29 │ 24.08 │ 0.81 │ 0.70 │ 0.67 │ 0.148 │ 0.161 │ 0.162
2026Distilled (on-policy privileged information distillation) proposedPSNR24.11split: test · contrast=T1 · acceleration=R=32 · undersampling=ES Cartesian-YNext-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction
Source quote
L354: Distilled │ 24.11 │ 18.42 │ 20.96 │ 0.74 │ 0.55 │ 0.57 │ 0.169 │ 0.230 │ 0.216
2026Distilled (on-policy privileged information distillation) proposedPSNR26.00split: test · contrast=T1 · acceleration=R=32 · undersampling=RadialNext-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction
Source quote
L359: Distilled │ 26.00 │ 20.51 │ 22.68 │ 0.78 │ 0.64 │ 0.63 │ 0.160 │ 0.196 │ 0.186
2025Interleaved (self-supervised loss added during training) proposedPSNR31.55split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brainBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L283: Interleaved │ 31.55 │ .7910
2025DEAL proposedPSNR36.59split: test · coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32
2025DEAL proposedPSNR36.21split: test · coils=multi-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=8-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32
2025C-MSM proposed non-standard slicePSNR32.7split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L179: C\text{-}MSM │ \hlblue{32.7} │ 0.853 │ \hlgreen{0.144} [2pt] \cdashline{1-5} [2pt]
2025C-MSM proposed non-standard slicePSNR28.8split: test · acs-lines=20 · acceleration=×8 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L187: C\text{-}MSM │ \hlgreen{28.8} │ \hlblue{0.760} │ 0.265
2025MFoE proposedPSNR35.40split: test · noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4Multivariate Fields of Experts
Source quote
L327: MFoE │ 35.40 │ 34.21 │ 30.26 │ 31.20
2025Supervised learning baseline non-standard slicePSNR32.68split: test · anatomy=knee · training=supervised with oracle ground truth · acceleration=6xBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L414: (Supervised) │ (32.68) │ (.8141)
2025SAFI baselinePSNR36.43split: test · coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L354: SAFI │ 36.43 │ 34.92 │ 36.06 │ 35.36
2025SAFI baselinePSNR36.06split: test · coils=multi-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=8-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L354: SAFI │ 36.43 │ 34.92 │ 36.06 │ 35.36
2025DDNM baselinePSNR32.9split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L178: DDNM │ \hlgreen{32.9} │ \hlgreen{0.864} │ \hlblue{0.159}
2025DDNM baselinePSNR28.6split: test · acs-lines=20 · acceleration=×8 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L186: DDNM │ \hlblue{28.6} │ \hlgreen{0.764} │ \hlblue{0.249}
2025Prox-DRUNet baselinePSNR35.32split: test · noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4Multivariate Fields of Experts
Source quote
L328: Prox-DRUNet │ 35.32 │ 34.53 │ 30.97 │ 31.66
2024aSeqDIP proposedPSNR34.08split: test · undersampling=4× · averaged-scans=20Image Reconstruction Via Autoencoding Sequential Deep Image Prior
Source quote
L533: 34.08
2024Deform-Mamba (Our) proposedPSNR32.11split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965
2024Self-Guided DIP (Generalized) proposedAverage reconstruction PSNR31.77 dBsplit: test · anatomy=knee · variant=Generalized · acceleration=4x · average-images=15Analysis of Deep Image Prior and Exploiting Self-Guidance for Image Reconstruction
Source quote
L627: 31.77
2024SAFI proposedPSNR36.43split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=4-fold · coil-setting=single-coil · patch-resolution=320×320Iteratively Refined Image Reconstruction with Learned Attentive Regularizers
Source quote
L790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860
2024SAFI proposedPSNR36.06split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=8-fold · coil-setting=multi-coil · patch-resolution=320×320Iteratively Refined Image Reconstruction with Learned Attentive Regularizers
Source quote
L790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860
2024E2E VarNet (trained on 8000 data points from fastMRI) baselinePSNR34.89split: test · training-data=8000 data points · undersampling=4×Image Reconstruction Via Autoencoding Sequential Deep Image Prior
Source quote
L528: 34.89
2024T (2)Net baselinePSNR30.56split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L178: T (2)Net │ 30.56 │ 0.6244 │ 29.73 │ 0.8773
2024Vanilla DIP (Generalized) baselineAverage reconstruction PSNR28.2 dBsplit: test · anatomy=knee · variant=Generalized · acceleration=4x · average-images=15Analysis of Deep Image Prior and Exploiting Self-Guidance for Image Reconstruction
Source quote
L626: 4x │ 28.2
2024SARR baselinePSNR35.98split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=8-fold · coil-setting=multi-coil · patch-resolution=320×320Iteratively Refined Image Reconstruction with Learned Attentive Regularizers
Source quote
L787: SARR \cite{NeuPouGou2023} │ 36.25 │ 34.77 │ 0.904 │ 0.839 │ 35.98 │ 35.26 │ 0.901 │ 0.858
2023McASSR (Ours; rectangle window 4×16/16×4) proposedPSNR32.52 dBsplit: test · scale=4x in-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PDRethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L483: 32.52
2023McASSR (Ours; rectangle window 4×16/16×4) proposedPSNR28.76 dBsplit: test · scale=8x out-of-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PDRethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L487: 28.76
2023APMC-PnP proposedPSNR32.70 dBsplit: test · acceleration=8×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1750: APMC-PnP (ours) │ 32.70 │ 36.03
2023APMC-PnP proposedPSNR36.03 dBsplit: test · acceleration=4×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1750: APMC-PnP (ours) │ 32.70 │ 36.03
2023VarNet-8× baselinePSNR32.82 dBsplit: test · fine-tuned · model=VarNet · acceleration=8×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1746: VarNet-8× │ 32.82 │ 35.01
2023VarNet-4× baselinePSNR36.00 dBsplit: test · fine-tuned · model=VarNet · acceleration=4×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1745: VarNet-4× │ 28.51 │ 36.00
2022CRR-NN proposedPSNR40.95split: test · coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-foldA Neural-Network-Based Convex Regularizer for Inverse Problems
Source quote
L794: CRR-NN │ {\bf 40.95} │ 38.91 │ {\bf 0.961} │ 0.934 │ 33.99 │ 33.75 │ 0.880 │ 0.831
2022LLS (\lambda=10 (-6)) proposedPSNR31.54split: test · mask=acceleration=4, center_fraction=0.08 · coils=single-coil · lambda=1e-6 · noise_sigma=0.01 · test_images=99Improving Lipschitz-Constrained Neural Networks by Learning Activation Functions
Source quote
L625: LLS │ 31.54 │ 0.7924 │ 28.04 │ 0.7108
2022FedGIMP proposedPSNR28.4 dBsplit: test · coil=single-coil · train-test-operator-shift=3x VD to 6x UDFederated Learning of Generative Image Priors for MRI Reconstruction
Source quote
L420: \multirow{1}{*}{FedGIMP} │ 35.3 │ 96.2 │ 28.4 │ 82.7 │ 46.9 │ 99.3
2022FedGIMP proposedPSNR38.4 dBsplit: test · coil=multi-coil · test-acceleration=6xFederated Learning of Generative Image Priors for MRI Reconstruction
Source quote
L542: \multirow{2}{*}{FedGIMP} │ 6x │ 38.4 │ 94.5
2022PnP-\betaCNN baselinePSNR38.77split: test · coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-foldA Neural-Network-Based Convex Regularizer for Inverse Problems
Source quote
L793: PnP-\betaCNN │ 38.77 │ 37.89 │ 0.943 │ 0.924 │ 31.37 │ 31.82 │ 0.832 │ 0.797
2022AV activation baselinePSNR30.61split: test · mask=acceleration=4, center_fraction=0.08 · coils=single-coil · noise_sigma=0.01 · test_images=99Improving Lipschitz-Constrained Neural Networks by Learning Activation Functions
Source quote
L622: AV │ 30.61 │ 0.7721 │ 27.35 │ 0.6921
2022Centralized training baselinePSNR30.47split: test · subset=F · setting=centralized · contrast=T2-weightedFederated Learning With Privacy-Preserving Ensemble Attention Distillation
Source quote
L438: F │ 0.9335 │ 34.58 │ 0.9002 │ 30.47
2022FedGAN baselinePSNR26.1 dBsplit: test · coil=single-coil · train-test-operator-shift=3x VD to 6x UDFederated Learning of Generative Image Priors for MRI Reconstruction
Source quote
L418: \multirow{1}{*}{FedGAN} │ 32.2 │ 92.4 │ 26.1 │ 79.4 │ 40.2 │ 96.5
2022FedGAN baselinePSNR34.8 dBsplit: test · coil=multi-coil · train-test-acceleration=3x to 6xFederated Learning of Generative Image Priors for MRI Reconstruction
Source quote
L537: \multirow{2}{*}{FedGAN} │ 3x\rightarrow6x │ 34.8 │ 91.9
2021DONet proposed non-standard slicePSNR32.780 dBsplit: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniformDONet: Dual-Octave Network for Fast MR Image Reconstruction
Source quote
L274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data.
2021Deep Equilibrium (Grad) proposedMean PSNR32.01split: test · roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8×Deep Equilibrium Architectures for Inverse Problems in Imaging
Source quote
L334: PSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38
2021Joint-ICNet proposedPSNR40.7split: test · reduction-factor=4Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L360: 40.7
2021Joint-ICNet proposedPSNR37.3split: test · reduction-factor=8Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L375: 37.3
2021A-DPS (proposed) proposedPSNR30.2split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L294: 30.2
2021Replace DC with ESPIRiT (Joint-ICNet variant) ablationPSNR39.4split: test · reduction-factor=4Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L364: 39.4
2021Replace DC with ESPIRiT (Joint-ICNet variant) ablationPSNR35.8split: test · reduction-factor=8Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L379: 35.8
2021ComplexMRI baseline non-standard slicePSNR29.992 dBsplit: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniformDONet: Dual-Octave Network for Fast MR Image Reconstruction
Source quote
L274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data.
2021Deep Unrolled (Grad) baselineMean PSNR31.13split: test · roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8×Deep Equilibrium Architectures for Inverse Problems in Imaging
Source quote
L334: PSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38
2021DPS baselinePSNR30.1split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L290: 30.1
2020DeepPhaseCut proposedPSNR19.820 dBsplit: test · coil=single-coil · image-type=complex-valued knee images; magnitude metrics · resolution=64×64 · oversampling-ratio=4DeepPhaseCut: Deep Relaxation in Phase for Unsupervised Fourier Phase Retrieval
Source quote
L628: DeepPhaseCut │ 19.820 │ 0.399 │ 0.042
2020Proposed Co-VeGAN proposedPSNR34.593 dBsplit: test · noise=noise-free · undersampling=30% · representation=complex-valued · sampling-pattern=1D-GCo-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image Reconstruction
Source quote
L296: \rule{0pt}{9pt} Proposed │ 1.7M │ 34.593 / 0.7893 │ 34.416 / 0.7870 │ 33.804 / 0.7673
2020OT-cycleGAN (Proposed) proposedPSNR28.7426 dBsplit: test · coil=single-coil · subset=ESC · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4xUnpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGAN
Source quote
L485: \ │ Proposed │ 28.7426 │ 0.6758 \multirow{8}*{Multi-Coil} │ \multirow{4}*{× 4} │ Input │ 28.0524 │ 0.7616
2020OT-cycleGAN (Proposed) proposedPSNR32.1812 dBsplit: test · coil=multi-coil (15-coil) · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4xUnpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGAN
Source quote
L488: \ │ Proposed │ 32.1812 │ 0.8300
2020PhaseCut baselinePSNR18.217 dBsplit: test · coil=single-coil · image-type=complex-valued knee images; magnitude metrics · resolution=64×64 · oversampling-ratio=4DeepPhaseCut: Deep Relaxation in Phase for Unsupervised Fourier Phase Retrieval
Source quote
L627: PhaseCut │ 18.217 │ 0.395 │ 1390.480
2020DAGAN-based baseline baselinePSNR29.911 dBsplit: test · noise=noise-free · undersampling=30% · representation=two real-valued channels · sampling-pattern=1D-GCo-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image Reconstruction
Source quote
L295: \rule{0pt}{9pt} Baseline │ 133M │ 29.911 / 0.5885 │ 29.820 / 0.5885 │ 29.576 / 0.5743
2020CycleGAN baselinePSNR20.8228 dBsplit: test · coil=single-coil · subset=ESC · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4xUnpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGAN
Source quote
L483: \ │ CycleGAN │ 20.8228 │ 0.4881
2020Supervised baselinePSNR32.5213 dBsplit: test · coil=multi-coil (15-coil) · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4xUnpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGAN
Source quote
L487: \ │ Supervised │ 32.5213 │ 0.8315
2019U-Net reconstruction with LOUPE Unconstrained mask baselinePSNR38.85split: test · subgroup=PD · acceleration=8-foldDeep-Learning-Based Optimization of the Under-Sampling Pattern in MRI
Source quote
L470: LOUPE Unconstrained │ 0.00014 │ 0.00066 │ 0.0085 │ 0.0199 │ 0.3044 │ 0.4303 │ 38.85 │ 31.83 │ 0.97 │ 0.87
2019U-Net reconstruction with Variable Density mask baselinePSNR35.82split: test · subgroup=PD · acceleration=8-foldDeep-Learning-Based Optimization of the Under-Sampling Pattern in MRI
Source quote
L468: Variable Density │ 0.00027 │ 0.00074 │ 0.0118 │ 0.0211 │ 0.4746 │ 0.5759 │ 35.82 │ 31.32 │ 0.96 │ 0.87
2019U-Net reconstruction with LOUPE Unconstrained mask baselinePSNR31.83split: test · subgroup=PDFS · acceleration=8-foldDeep-Learning-Based Optimization of the Under-Sampling Pattern in MRI
Source quote
L470: LOUPE Unconstrained │ 0.00014 │ 0.00066 │ 0.0085 │ 0.0199 │ 0.3044 │ 0.4303 │ 38.85 │ 31.83 │ 0.97 │ 0.87
2019U-Net reconstruction with Variable Density mask baselinePSNR31.32split: test · subgroup=PDFS · acceleration=8-foldDeep-Learning-Based Optimization of the Under-Sampling Pattern in MRI
Source quote
L468: Variable Density │ 0.00027 │ 0.00074 │ 0.0118 │ 0.0211 │ 0.4746 │ 0.5759 │ 35.82 │ 31.32 │ 0.96 │ 0.87
2019U-Net reconstruction with LOUPE Unconstrained mask baselinePSNR40.71split: test · subgroup=PD · acceleration=4-foldDeep-Learning-Based Optimization of the Under-Sampling Pattern in MRI
Source quote
L441: LOUPE Unconstrained │ 0.00009 │ 0.00048 │ 0.0071 │ 0.0173 │ 0.1681 │ 0.246 │ 40.71 │ 33.16 │ 0.98 │ 0.91