fastMRI
86 papers · 287 extracted observations · mri reconstruction · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CRR-NN SOTA frontier | 40.95 | 2023-01-01 | coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-fold · FastMRI knee PD test images; 2-fold Cartesian undersampling, measurement noise standa… | A Neural-Network-Based Convex Regularizer for Inverse ProblemsSource quoteCRR-NN │ {\bf 40.95} │ 38.91 │ {\bf 0.961} │ 0.934 │ 33.99 │ 33.75 │ 0.880 │ 0.831 |
| 2 | Joint-ICNet SOTA frontier (+3 variants) | 40.7 | 2021-01-01 | reduction-factor=4 · Table 2 model ablation; reduction factor R=4. Paper setup uses multi-coil k-space ret… | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quote40.7 |
| 3 | DEAL (+1 variant) | 36.59 | 2025-01-01 | coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-fold · 4-fold single-coil setup; centered 320×320 patches from 50 test images; additive whit… | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteDEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32 |
| 4 | SAFI (+1 variant) | 36.43 | 2024-07-01 | subset=50 test images · sequence=PD · resolution=320x320 · acceleration=4-fold · coil-setting=single-coil · patch-resolution=320×320 · PD knee images without fat suppression; denoising-trained model, with λ tuned on 10 v… | Iteratively Refined Image Reconstruction with Learned Attentive RegularizersSource quoteSAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860 |
| 5 | MFoE | 35.4 | 2025-08-01 | noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4 · PD data; acceleration factor 4 and center fraction 0.08; Gaussian measurement noise w… | Multivariate Fields of ExpertsSource quoteMFoE │ 35.40 │ 34.21 │ 30.26 │ 31.20 |
| 6 | aSeqDIP | 34.08 | 2024-01-01 | undersampling=4× · averaged-scans=20 · Average over 20 MRI scans from the fastMRI testing set at 4× undersampling; no labele… | Image Reconstruction Via Autoencoding Sequential Deep Image PriorSource quote34.08 |
| 7 | Deform-Mamba (Our) | 32.11 | 2024-07-01 | scale=4× · 4× upsampling; held-out test split (45 subjects); low-resolution inputs synthesized i… | Deform-Mamba Network for MRI Super-ResolutionSource quoteOur │ 32.11 │ 0.7194 │ 30.60 │ 0.8965 |
| 8 | Deep Equilibrium (Grad) | 32.01 | 2021-02-01 | roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8× · Test-set mean; 8× accelerated virtual single-coil Cartesian MRI with complex AWGN sta… | Deep Equilibrium Architectures for Inverse Problems in ImagingSource quotePSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38 |
| 9 | Interleaved (self-supervised loss added during training) | 31.55 | 2025-01-01 | method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brain · 6x-accelerated MRI; trained on the FastMRI brain dataset and tested on knees. | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteInterleaved │ 31.55 │ .7910 |
| 10 | LLS (\lambda=10 (-6)) | 31.54 | 2024-01-01 | mask=acceleration=4, center_fraction=0.08 · coils=single-coil · lambda=1e-6 · noise_sigma=0.01 · test_images=99 · PnP-FBS reconstruction; measurement noise \sigma-\mathbf n=0.01; mask (M_{\text{acc}}… | Improving Lipschitz-Constrained Neural Networks by Learning Activation FunctionsSource quoteLLS │ 31.54 │ 0.7924 │ 28.04 │ 0.7108 |
| 11 | A-DPS (proposed) | 30.2 | 2021-01-01 | resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 · Table 2: acceleration factor 8; scenario-30L (30 k-space lines closest to DC, with 16… | Active Deep Probabilistic SubsamplingSource quote30.2 |
| 12 | Distilled (on-policy privileged information distillation) (+2 variants) | 27.86 | 2026-05-01 | contrast=T1 · acceleration=R=32 · undersampling=Gaussian-VD · R=32; Gaussian-VD undersampling; T1 contrast. | Next-Acceleration-Scale Prediction for Autoregressive MRI ReconstructionSource quoteDistilled │ 27.86 │ 22.29 │ 24.08 │ 0.81 │ 0.70 │ 0.67 │ 0.148 │ 0.161 │ 0.162 |
Showing 62 of 62 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Distilled (on-policy privileged information distillation) proposed | PSNR | 27.86 | split: test · contrast=T1 · acceleration=R=32 · undersampling=Gaussian-VD | Next-Acceleration-Scale Prediction for Autoregressive MRI ReconstructionSource quoteL344: Distilled │ 27.86 │ 22.29 │ 24.08 │ 0.81 │ 0.70 │ 0.67 │ 0.148 │ 0.161 │ 0.162 |
| 2026 | Distilled (on-policy privileged information distillation) proposed | PSNR | 24.11 | split: test · contrast=T1 · acceleration=R=32 · undersampling=ES Cartesian-Y | Next-Acceleration-Scale Prediction for Autoregressive MRI ReconstructionSource quoteL354: Distilled │ 24.11 │ 18.42 │ 20.96 │ 0.74 │ 0.55 │ 0.57 │ 0.169 │ 0.230 │ 0.216 |
| 2026 | Distilled (on-policy privileged information distillation) proposed | PSNR | 26.00 | split: test · contrast=T1 · acceleration=R=32 · undersampling=Radial | Next-Acceleration-Scale Prediction for Autoregressive MRI ReconstructionSource quoteL359: Distilled │ 26.00 │ 20.51 │ 22.68 │ 0.78 │ 0.64 │ 0.63 │ 0.160 │ 0.196 │ 0.186 |
| 2025 | Interleaved (self-supervised loss added during training) proposed | PSNR | 31.55 | split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brain | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteL283: Interleaved │ 31.55 │ .7910 |
| 2025 | DEAL proposed | PSNR | 36.59 | split: test · coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-fold | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteL355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32 |
| 2025 | DEAL proposed | PSNR | 36.21 | split: test · coils=multi-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=8-fold | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteL355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32 |
| 2025 | C-MSM proposed non-standard slice | PSNR | 32.7 | split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01 | Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity EstimationSource quoteL179: C\text{-}MSM │ \hlblue{32.7} │ 0.853 │ \hlgreen{0.144} [2pt] \cdashline{1-5} [2pt] |
| 2025 | C-MSM proposed non-standard slice | PSNR | 28.8 | split: test · acs-lines=20 · acceleration=×8 · measurement-noise=σ=0.01 | Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity EstimationSource quoteL187: C\text{-}MSM │ \hlgreen{28.8} │ \hlblue{0.760} │ 0.265 |
| 2025 | MFoE proposed | PSNR | 35.40 | split: test · noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4 | Multivariate Fields of ExpertsSource quoteL327: MFoE │ 35.40 │ 34.21 │ 30.26 │ 31.20 |
| 2025 | Supervised learning baseline non-standard slice | PSNR | 32.68 | split: test · anatomy=knee · training=supervised with oracle ground truth · acceleration=6x | Benchmarking Self-Supervised Learning Methods for Accelerated MRI ReconstructionSource quoteL414: (Supervised) │ (32.68) │ (.8141) |
| 2025 | SAFI baseline | PSNR | 36.43 | split: test · coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-fold | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteL354: SAFI │ 36.43 │ 34.92 │ 36.06 │ 35.36 |
| 2025 | SAFI baseline | PSNR | 36.06 | split: test · coils=multi-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=8-fold | DEALing with Image Reconstruction: Deep Attentive Least SquaresSource quoteL354: SAFI │ 36.43 │ 34.92 │ 36.06 │ 35.36 |
| 2025 | DDNM baseline | PSNR | 32.9 | split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01 | Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity EstimationSource quoteL178: DDNM │ \hlgreen{32.9} │ \hlgreen{0.864} │ \hlblue{0.159} |
| 2025 | DDNM baseline | PSNR | 28.6 | split: test · acs-lines=20 · acceleration=×8 · measurement-noise=σ=0.01 | Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity EstimationSource quoteL186: DDNM │ \hlblue{28.6} │ \hlgreen{0.764} │ \hlblue{0.249} |
| 2025 | Prox-DRUNet baseline | PSNR | 35.32 | split: test · noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4 | Multivariate Fields of ExpertsSource quoteL328: Prox-DRUNet │ 35.32 │ 34.53 │ 30.97 │ 31.66 |
| 2024 | aSeqDIP proposed | PSNR | 34.08 | split: test · undersampling=4× · averaged-scans=20 | Image Reconstruction Via Autoencoding Sequential Deep Image PriorSource quoteL533: 34.08 |
| 2024 | Deform-Mamba (Our) proposed | PSNR | 32.11 | split: test · scale=4× | Deform-Mamba Network for MRI Super-ResolutionSource quoteL180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965 |
| 2024 | Self-Guided DIP (Generalized) proposed | Average reconstruction PSNR | 31.77 dB | split: test · anatomy=knee · variant=Generalized · acceleration=4x · average-images=15 | Analysis of Deep Image Prior and Exploiting Self-Guidance for Image ReconstructionSource quoteL627: 31.77 |
| 2024 | SAFI proposed | PSNR | 36.43 | split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=4-fold · coil-setting=single-coil · patch-resolution=320×320 | Iteratively Refined Image Reconstruction with Learned Attentive RegularizersSource quoteL790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860 |
| 2024 | SAFI proposed | PSNR | 36.06 | split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=8-fold · coil-setting=multi-coil · patch-resolution=320×320 | Iteratively Refined Image Reconstruction with Learned Attentive RegularizersSource quoteL790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860 |
| 2024 | E2E VarNet (trained on 8000 data points from fastMRI) baseline | PSNR | 34.89 | split: test · training-data=8000 data points · undersampling=4× | Image Reconstruction Via Autoencoding Sequential Deep Image PriorSource quoteL528: 34.89 |
| 2024 | T (2)Net baseline | PSNR | 30.56 | split: test · scale=4× | Deform-Mamba Network for MRI Super-ResolutionSource quoteL178: T (2)Net │ 30.56 │ 0.6244 │ 29.73 │ 0.8773 |
| 2024 | Vanilla DIP (Generalized) baseline | Average reconstruction PSNR | 28.2 dB | split: test · anatomy=knee · variant=Generalized · acceleration=4x · average-images=15 | Analysis of Deep Image Prior and Exploiting Self-Guidance for Image ReconstructionSource quoteL626: 4x │ 28.2 |
| 2024 | SARR baseline | PSNR | 35.98 | split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=8-fold · coil-setting=multi-coil · patch-resolution=320×320 | Iteratively Refined Image Reconstruction with Learned Attentive RegularizersSource quoteL787: SARR \cite{NeuPouGou2023} │ 36.25 │ 34.77 │ 0.904 │ 0.839 │ 35.98 │ 35.26 │ 0.901 │ 0.858 |
| 2023 | McASSR (Ours; rectangle window 4×16/16×4) proposed | PSNR | 32.52 dB | split: test · scale=4x in-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PD | Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale UpsamplingSource quoteL483: 32.52 |
| 2023 | McASSR (Ours; rectangle window 4×16/16×4) proposed | PSNR | 28.76 dB | split: test · scale=8x out-of-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PD | Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale UpsamplingSource quoteL487: 28.76 |
| 2023 | APMC-PnP proposed | PSNR | 32.70 dB | split: test · acceleration=8× | Provable Probabilistic Imaging using Score-based Generative PriorsSource quoteL1750: APMC-PnP (ours) │ 32.70 │ 36.03 |
| 2023 | APMC-PnP proposed | PSNR | 36.03 dB | split: test · acceleration=4× | Provable Probabilistic Imaging using Score-based Generative PriorsSource quoteL1750: APMC-PnP (ours) │ 32.70 │ 36.03 |
| 2023 | VarNet-8× baseline | PSNR | 32.82 dB | split: test · fine-tuned · model=VarNet · acceleration=8× | Provable Probabilistic Imaging using Score-based Generative PriorsSource quoteL1746: VarNet-8× │ 32.82 │ 35.01 |
| 2023 | VarNet-4× baseline | PSNR | 36.00 dB | split: test · fine-tuned · model=VarNet · acceleration=4× | Provable Probabilistic Imaging using Score-based Generative PriorsSource quoteL1745: VarNet-4× │ 28.51 │ 36.00 |
| 2022 | CRR-NN proposed | PSNR | 40.95 | split: test · coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-fold | A Neural-Network-Based Convex Regularizer for Inverse ProblemsSource quoteL794: CRR-NN │ {\bf 40.95} │ 38.91 │ {\bf 0.961} │ 0.934 │ 33.99 │ 33.75 │ 0.880 │ 0.831 |
| 2022 | LLS (\lambda=10 (-6)) proposed | PSNR | 31.54 | split: test · mask=acceleration=4, center_fraction=0.08 · coils=single-coil · lambda=1e-6 · noise_sigma=0.01 · test_images=99 | Improving Lipschitz-Constrained Neural Networks by Learning Activation FunctionsSource quoteL625: LLS │ 31.54 │ 0.7924 │ 28.04 │ 0.7108 |
| 2022 | FedGIMP proposed | PSNR | 28.4 dB | split: test · coil=single-coil · train-test-operator-shift=3x VD to 6x UD | Federated Learning of Generative Image Priors for MRI ReconstructionSource quoteL420: \multirow{1}{*}{FedGIMP} │ 35.3 │ 96.2 │ 28.4 │ 82.7 │ 46.9 │ 99.3 |
| 2022 | FedGIMP proposed | PSNR | 38.4 dB | split: test · coil=multi-coil · test-acceleration=6x | Federated Learning of Generative Image Priors for MRI ReconstructionSource quoteL542: \multirow{2}{*}{FedGIMP} │ 6x │ 38.4 │ 94.5 |
| 2022 | PnP-\betaCNN baseline | PSNR | 38.77 | split: test · coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-fold | A Neural-Network-Based Convex Regularizer for Inverse ProblemsSource quoteL793: PnP-\betaCNN │ 38.77 │ 37.89 │ 0.943 │ 0.924 │ 31.37 │ 31.82 │ 0.832 │ 0.797 |
| 2022 | AV activation baseline | PSNR | 30.61 | split: test · mask=acceleration=4, center_fraction=0.08 · coils=single-coil · noise_sigma=0.01 · test_images=99 | Improving Lipschitz-Constrained Neural Networks by Learning Activation FunctionsSource quoteL622: AV │ 30.61 │ 0.7721 │ 27.35 │ 0.6921 |
| 2022 | Centralized training baseline | PSNR | 30.47 | split: test · subset=F · setting=centralized · contrast=T2-weighted | Federated Learning With Privacy-Preserving Ensemble Attention DistillationSource quoteL438: F │ 0.9335 │ 34.58 │ 0.9002 │ 30.47 |
| 2022 | FedGAN baseline | PSNR | 26.1 dB | split: test · coil=single-coil · train-test-operator-shift=3x VD to 6x UD | Federated Learning of Generative Image Priors for MRI ReconstructionSource quoteL418: \multirow{1}{*}{FedGAN} │ 32.2 │ 92.4 │ 26.1 │ 79.4 │ 40.2 │ 96.5 |
| 2022 | FedGAN baseline | PSNR | 34.8 dB | split: test · coil=multi-coil · train-test-acceleration=3x to 6x | Federated Learning of Generative Image Priors for MRI ReconstructionSource quoteL537: \multirow{2}{*}{FedGAN} │ 3x\rightarrow6x │ 34.8 │ 91.9 |
| 2021 | DONet proposed non-standard slice | PSNR | 32.780 dB | split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniform | DONet: Dual-Octave Network for Fast MR Image ReconstructionSource quoteL274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data. |
| 2021 | Deep Equilibrium (Grad) proposed | Mean PSNR | 32.01 | split: test · roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8× | Deep Equilibrium Architectures for Inverse Problems in ImagingSource quoteL334: PSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38 |
| 2021 | Joint-ICNet proposed | PSNR | 40.7 | split: test · reduction-factor=4 | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quoteL360: 40.7 |
| 2021 | Joint-ICNet proposed | PSNR | 37.3 | split: test · reduction-factor=8 | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quoteL375: 37.3 |
| 2021 | A-DPS (proposed) proposed | PSNR | 30.2 | split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 | Active Deep Probabilistic SubsamplingSource quoteL294: 30.2 |
| 2021 | Replace DC with ESPIRiT (Joint-ICNet variant) ablation | PSNR | 39.4 | split: test · reduction-factor=4 | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quoteL364: 39.4 |
| 2021 | Replace DC with ESPIRiT (Joint-ICNet variant) ablation | PSNR | 35.8 | split: test · reduction-factor=8 | Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRISource quoteL379: 35.8 |
| 2021 | ComplexMRI baseline non-standard slice | PSNR | 29.992 dB | split: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniform | DONet: Dual-Octave Network for Fast MR Image ReconstructionSource quoteL274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data. |
| 2021 | Deep Unrolled (Grad) baseline | Mean PSNR | 31.13 | split: test · roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8× | Deep Equilibrium Architectures for Inverse Problems in ImagingSource quoteL334: PSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38 |
| 2021 | DPS baseline | PSNR | 30.1 | split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8 | Active Deep Probabilistic SubsamplingSource quoteL290: 30.1 |
| 2020 | DeepPhaseCut proposed | PSNR | 19.820 dB | split: test · coil=single-coil · image-type=complex-valued knee images; magnitude metrics · resolution=64×64 · oversampling-ratio=4 | DeepPhaseCut: Deep Relaxation in Phase for Unsupervised Fourier Phase RetrievalSource quoteL628: DeepPhaseCut │ 19.820 │ 0.399 │ 0.042 |
| 2020 | Proposed Co-VeGAN proposed | PSNR | 34.593 dB | split: test · noise=noise-free · undersampling=30% · representation=complex-valued · sampling-pattern=1D-G | Co-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image ReconstructionSource quoteL296: \rule{0pt}{9pt} Proposed │ 1.7M │ 34.593 / 0.7893 │ 34.416 / 0.7870 │ 33.804 / 0.7673 |
| 2020 | OT-cycleGAN (Proposed) proposed | PSNR | 28.7426 dB | split: test · coil=single-coil · subset=ESC · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4x | Unpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGANSource quoteL485: \ │ Proposed │ 28.7426 │ 0.6758 \multirow{8}*{Multi-Coil} │ \multirow{4}*{× 4} │ Input │ 28.0524 │ 0.7616 |
| 2020 | OT-cycleGAN (Proposed) proposed | PSNR | 32.1812 dB | split: test · coil=multi-coil (15-coil) · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4x | Unpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGANSource quoteL488: \ │ Proposed │ 32.1812 │ 0.8300 |
| 2020 | PhaseCut baseline | PSNR | 18.217 dB | split: test · coil=single-coil · image-type=complex-valued knee images; magnitude metrics · resolution=64×64 · oversampling-ratio=4 | DeepPhaseCut: Deep Relaxation in Phase for Unsupervised Fourier Phase RetrievalSource quoteL627: PhaseCut │ 18.217 │ 0.395 │ 1390.480 |
| 2020 | DAGAN-based baseline baseline | PSNR | 29.911 dB | split: test · noise=noise-free · undersampling=30% · representation=two real-valued channels · sampling-pattern=1D-G | Co-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image ReconstructionSource quoteL295: \rule{0pt}{9pt} Baseline │ 133M │ 29.911 / 0.5885 │ 29.820 / 0.5885 │ 29.576 / 0.5743 |
| 2020 | CycleGAN baseline | PSNR | 20.8228 dB | split: test · coil=single-coil · subset=ESC · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4x | Unpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGANSource quoteL483: \ │ CycleGAN │ 20.8228 │ 0.4881 |
| 2020 | Supervised baseline | PSNR | 32.5213 dB | split: test · coil=multi-coil (15-coil) · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4x | Unpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGANSource quoteL487: \ │ Supervised │ 32.5213 │ 0.8315 |
| 2019 | U-Net reconstruction with LOUPE Unconstrained mask baseline | PSNR | 38.85 | split: test · subgroup=PD · acceleration=8-fold | Deep-Learning-Based Optimization of the Under-Sampling Pattern in MRISource quoteL470: LOUPE Unconstrained │ 0.00014 │ 0.00066 │ 0.0085 │ 0.0199 │ 0.3044 │ 0.4303 │ 38.85 │ 31.83 │ 0.97 │ 0.87 |
| 2019 | U-Net reconstruction with Variable Density mask baseline | PSNR | 35.82 | split: test · subgroup=PD · acceleration=8-fold | Deep-Learning-Based Optimization of the Under-Sampling Pattern in MRISource quoteL468: Variable Density │ 0.00027 │ 0.00074 │ 0.0118 │ 0.0211 │ 0.4746 │ 0.5759 │ 35.82 │ 31.32 │ 0.96 │ 0.87 |
| 2019 | U-Net reconstruction with LOUPE Unconstrained mask baseline | PSNR | 31.83 | split: test · subgroup=PDFS · acceleration=8-fold | Deep-Learning-Based Optimization of the Under-Sampling Pattern in MRISource quoteL470: LOUPE Unconstrained │ 0.00014 │ 0.00066 │ 0.0085 │ 0.0199 │ 0.3044 │ 0.4303 │ 38.85 │ 31.83 │ 0.97 │ 0.87 |
| 2019 | U-Net reconstruction with Variable Density mask baseline | PSNR | 31.32 | split: test · subgroup=PDFS · acceleration=8-fold | Deep-Learning-Based Optimization of the Under-Sampling Pattern in MRISource quoteL468: Variable Density │ 0.00027 │ 0.00074 │ 0.0118 │ 0.0211 │ 0.4746 │ 0.5759 │ 35.82 │ 31.32 │ 0.96 │ 0.87 |
| 2019 | U-Net reconstruction with LOUPE Unconstrained mask baseline | PSNR | 40.71 | split: test · subgroup=PD · acceleration=4-fold | Deep-Learning-Based Optimization of the Under-Sampling Pattern in MRISource quoteL441: LOUPE Unconstrained │ 0.00009 │ 0.00048 │ 0.0071 │ 0.0173 │ 0.1681 │ 0.246 │ 40.71 │ 33.16 │ 0.98 │ 0.91 |