22.829.335.842.3202120242026A-DPS (proposed): 30.2 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 35.8 (2021)Joint-ICNet: 37.3 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 39.4 (2021)Joint-ICNet: 40.7 (2021)Deep Equilibrium (Grad): 32.01 (2021)CRR-NN: 40.95 (2023)LLS (\lambda=10 (-6)): 31.54 (2024)aSeqDIP: 34.08 (2024)Deform-Mamba (Our): 32.11 (2024)SAFI: 36.06 (2024)SAFI: 36.43 (2024)Interleaved (self-supervised loss added during training): 31.55 (2025)DEAL: 36.21 (2025)DEAL: 36.59 (2025)MFoE: 35.4 (2025)Distilled (on-policy privileged information distillation): 24.11 (2026)Distilled (on-policy privileged information distillation): 26.0 (2026)Distilled (on-policy privileged information distillation): 27.86 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 76 of 76 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Distilled (on-policy privileged information distillation) proposedPSNR27.86split: test · contrast=T1 · acceleration=R=32 · undersampling=Gaussian-VDNext-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction
Source quote
L344: Distilled │ 27.86 │ 22.29 │ 24.08 │ 0.81 │ 0.70 │ 0.67 │ 0.148 │ 0.161 │ 0.162
2026Distilled (on-policy privileged information distillation) proposedPSNR24.11split: test · contrast=T1 · acceleration=R=32 · undersampling=ES Cartesian-YNext-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction
Source quote
L354: Distilled │ 24.11 │ 18.42 │ 20.96 │ 0.74 │ 0.55 │ 0.57 │ 0.169 │ 0.230 │ 0.216
2026Distilled (on-policy privileged information distillation) proposedPSNR26.00split: test · contrast=T1 · acceleration=R=32 · undersampling=RadialNext-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction
Source quote
L359: Distilled │ 26.00 │ 20.51 │ 22.68 │ 0.78 │ 0.64 │ 0.63 │ 0.160 │ 0.196 │ 0.186
2026OCDI-Net proposedPSNR41.88SMS=MB3R1 · subset=T2 · reconstruction=single-stage SMS unaliasing · image-representation=RSS magnitudeBack to Physics: Operator-Guided Generative Paths for SMS MRI Reconstruction
Source quote
L619: OCDI-Net │ 41.88 │ 0.966 │ \boldsymbol{2.5× 10 (-3)}
2026SGPnP-PGM (Decouple) proposedPSNR32.54acceleration=4x · noise-levels=decoupledStochastic Generative Plug-and-Play Priors
Source quote
L753: \multicolumn{1}{c}{\hlgreen{32.91}} │ \multicolumn{1}{c}{31.44} │ \multicolumn{1}{c}{\hlgreen{33.32}} │ \multicolumn{1}{c}{30.20} │ \multicolumn{1}{c}{\hlgreen{32.54}} \\[+.95ex]
2026PAS-Mamba proposedPSNR32.46Radial mask, ×2 acceleration.PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI Reconstruction
Source quote
L241: Ours │ 32.46 │ 0.8838 │ 28.84 │ 0.8301
2026PAS-Mamba proposedPSNR26.47Cartesian mask, ×4 acceleration.PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI Reconstruction
Source quote
L249: Ours │ 28.35 │ 0.7058 │ 26.47 │ 0.7081
2025SDUM proposedPSNR42.6 dBcoils=multi-coil · anatomy=brain · acceleration=4× · unrolling-steps=6SDUM: A Scalable Deep Unrolled Model for Universal MRI Reconstruction
Source quote
L403: SDUM (Ours) │ 0.979 │ \multicolumn{1}{c|}{42.6} │ 0.973 │ 40.8
2025PR-INR proposedPSNR33.3 dBmotion-displacement=3%From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction
Source quote
L617: Table~\ref{tab:ablation_final} shows that the full configuration of our PR-INR framework consistently achieves the best performance across all undersampling settings on both the FastMRI and HCP 1200 datasets. At 3% and 5% displacement during acquisition, the complete model achieves strong gains over the baseline. For instance, PSNR/SSIM improves from 30.0/0.853 to 33.3/0.919 on FastMRI, and from 24.3/0.820 to 27.0/0.904 on HCP 1200 at 3%, with similar trends at 5%. Under 4x and 8x undersampling, PR-INR remains robust, consistently outperforming variants. At 8x, it improves PSNR from 23.9 to 26.4 and SSIM from 0.645 to 0.721 on FastMRI, and shows comparable improvements on HCP. The IDR module plays a key role in enhancing perceptual and structural quality (e.g., LPIPS drops and SSIM improves), while the VCR module further enforces volumetric smoothness, reflected in higher NCC values. These results validate the complementary contributions of each module and the generalizability of PR-INR across different datasets and acceleration regimes.
2025PR-INR proposedPSNR28.9 dBacceleration=4×From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction
Source quote
L563: {Table~\ref{tab:motion} shows that our PR-INR outperforms state-of-the-art MRI reconstruction methods under both 4× and 8× acceleration on the fastMRI and HCP1200 datasets.} The model maintains superior image quality and structural consistency despite reduced sampling, indicating its capacity to restore high-frequency details and suppress undersampling artifacts. It achieves the highest PSNR (28.9/26.4 dB on fastMRI, 26.4/24.0 dB on HCP1200) and SSIM (0.887/0.721 on fastMRI, 0.895/0.849 on HCP1200), indicating superior reconstruction quality and perceptual fidelity. Fig.~\ref{fig4} (c) and (d) further demonstrate the advantages of PR-INR in visual quality. Compared to baseline models, our method reconstructs sharper anatomical boundaries and suppresses noise and artifacts. The zoomed-in regions especially highlight its ability to retain fine-grained features and maintain consistency with ground truth images.
2025PR-INR proposedPSNR26.4 dBacceleration=8×From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction
Source quote
L563: {Table~\ref{tab:motion} shows that our PR-INR outperforms state-of-the-art MRI reconstruction methods under both 4× and 8× acceleration on the fastMRI and HCP1200 datasets.} The model maintains superior image quality and structural consistency despite reduced sampling, indicating its capacity to restore high-frequency details and suppress undersampling artifacts. It achieves the highest PSNR (28.9/26.4 dB on fastMRI, 26.4/24.0 dB on HCP1200) and SSIM (0.887/0.721 on fastMRI, 0.895/0.849 on HCP1200), indicating superior reconstruction quality and perceptual fidelity. Fig.~\ref{fig4} (c) and (d) further demonstrate the advantages of PR-INR in visual quality. Compared to baseline models, our method reconstructs sharper anatomical boundaries and suppresses noise and artifacts. The zoomed-in regions especially highlight its ability to retain fine-grained features and maintain consistency with ground truth images.
2025Interleaved (self-supervised loss added during training) proposedPSNR31.55split: test · method=interleaved self-supervised loss · acceleration=6x · test-anatomy=knee · training-anatomy=brainBenchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstruction
Source quote
L283: Interleaved │ 31.55 │ .7910
2025DEAL proposedPSNR36.59split: test · coils=single-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=4-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32
2025DEAL proposedPSNR36.21split: test · coils=multi-coil · contrast=PD · resolution=320×320 · noise_sigma=0.002 · acceleration=8-foldDEALing with Image Reconstruction: Deep Attentive Least Squares
Source quote
L355: DEAL (Ours) │ 36.59 │ 34.92 │ 36.21 │ 35.32
2025RFJS proposedPSNR (↑)25.85ACS=2% · coils=multi-coil · anatomy=knee · contrast=PDFS with PD · acceleration_factor=16Inference-Time Search Using Side Information for Diffusion-Based Image Reconstruction
Source quote
L1040: RFJS │ 25.85 │ 0.801 │ 0.375 │ 0.457
2025C-MSM proposed non-standard slicePSNR32.7split: test · acs-lines=20 · acceleration=×4 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L179: C\text{-}MSM │ \hlblue{32.7} │ 0.853 │ \hlgreen{0.144} [2pt] \cdashline{1-5} [2pt]
2025C-MSM proposed non-standard slicePSNR28.8split: test · acs-lines=20 · acceleration=×8 · measurement-noise=σ=0.01Measurement Score-Based MRI Reconstruction with Automatic Coil Sensitivity Estimation
Source quote
L187: C\text{-}MSM │ \hlgreen{28.8} │ \hlblue{0.760} │ 0.265
2025MFoE proposedPSNR35.40split: test · noise-std=0.01 · test-images=50 · center-fraction=0.08 · acceleration-factor=4Multivariate Fields of Experts
Source quote
L327: MFoE │ 35.40 │ 34.21 │ 30.26 │ 31.20
2025Ours (uCMS + IrR) proposedPSNR27.97scale-factor=4× · reconstruction=2D slice-basedDecoupling Multi-Contrast Super-Resolution: Pairing Unpaired Synthesis with Implicit Representations
Source quote
L248: 27.97
2025HiFi-Mamba (P1) proposed non-standard slicePSNR34.85 dBsubset=PDFS single-coil knee · patch-size=1 · undersampling=equispaced 1D Cartesian · acceleration-factor=4HiFi-Mamba: Dual-Stream 𝒲 -Laplacian Enhanced Mamba for High-Fidelity MRI Reconstruction
Source quote
L285: The finer-grained variant HiFi-Mamba (P1), with a patch size of 1, further improves reconstruction performance, establishing a new state-of-the-art. Specifically, it achieves 34.85 / 31.81 dB PSNR and 0.855 / 0.762 SSIM on fastMRI (\text{AF}=4 / 8), with corresponding NMSE of 0.010 / 0.020. On CC359, it achieves 36.93 dB PSNR and 0.942 SSIM at \text{AF}=4, and maintains robust performance at \text{AF}=8, reaching 28.49 dB PSNR, 0.810 SSIM, and 0.026 NMSE, consistently surpassing prior state-of-the-art methods across all metrics.
2025HiFi-Mamba (P1) proposed non-standard slicePSNR31.81 dBsubset=PDFS single-coil knee · patch-size=1 · undersampling=equispaced 1D Cartesian · acceleration-factor=8HiFi-Mamba: Dual-Stream 𝒲 -Laplacian Enhanced Mamba for High-Fidelity MRI Reconstruction
Source quote
L285: The finer-grained variant HiFi-Mamba (P1), with a patch size of 1, further improves reconstruction performance, establishing a new state-of-the-art. Specifically, it achieves 34.85 / 31.81 dB PSNR and 0.855 / 0.762 SSIM on fastMRI (\text{AF}=4 / 8), with corresponding NMSE of 0.010 / 0.020. On CC359, it achieves 36.93 dB PSNR and 0.942 SSIM at \text{AF}=4, and maintains robust performance at \text{AF}=8, reaching 28.49 dB PSNR, 0.810 SSIM, and 0.026 NMSE, consistently surpassing prior state-of-the-art methods across all metrics.
2025HiFi-Mamba (P2) proposedPSNR31.38 dBGPU=NVIDIA A100 · FLOPs=67.87G · patch-size=2 · resolution=320×320 · acceleration-factor=8HiFi-Mamba: Dual-Stream 𝒲 -Laplacian Enhanced Mamba for High-Fidelity MRI Reconstruction
Source quote
L302: HiFi-Mamba (P2) achieves 31.38\,dB PSNR and 0.758 SSIM with only 67.87G FLOPs—substantially lower than all competing models, while matching or surpassing heavier attention-based architectures such as ReconFormer and FpsFormer.
2025Proposed BED procedure proposedPSNR16.0957subset=brain · iteration=1 · k-space-sampled=3.3659%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L210: 1 │ 16.0957 │ 0.7890 │ 3.3659
2025Proposed BED procedure proposedPSNR20.6784subset=brain · iteration=9 · k-space-sampled=15.6789%Active MRI Acquisition with Diffusion Guided Bayesian Experimental Design
Source quote
L214: 9 │ 20.6784 │ 0.9104 │ 15.6789
2024Nila (Nila-DC) proposedPSNR37.08split: val · noise=none · acceleration=6×Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRI
Source quote
L124: Nila (ours) │ \textcolor{red}{37.08} │ \textcolor{red}{95.74} │ \textcolor{red}{34.82} │ \textcolor{red}{94.21} │ \textcolor{red}{36.10} │ \textcolor{red}{94.34} │ \textcolor{red}{33.54} │ \textcolor{red}{91.55} │ \textcolor{red}{30.23} │ \textcolor{red}{91.59} │ \textcolor{red}{29.86} │ \textcolor{red}{90.06}
2024Nila (Nila-DC) proposedPSNR31.86split: val · noise=Gaussian σ=0.1 · acceleration=6×Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRI
Source quote
L145: Nila (ours) │ \textcolor{red}{34.98} │ \textcolor{red}{93.96} │ \textcolor{red}{33.56} │ \textcolor{red}{92.49} │ \textcolor{red}{31.86} │ \textcolor{red}{90.38} │ \textcolor{red}{34.11} │ \textcolor{red}{91.53} │ \textcolor{red}{32.80} │ \textcolor{red}{89.59} │ \textcolor{red}{31.25} │ \textcolor{red}{87.15}
2024aSeqDIP proposedPSNR34.08split: test · undersampling=4× · averaged-scans=20Image Reconstruction Via Autoencoding Sequential Deep Image Prior
Source quote
L533: 34.08
2024SPGD Jittering proposed non-standard slicePSNR27.56evaluation=adversarial attack · acceleration=4×SGD Jittering: A Training Strategy for Robust and Accurate Model-Based Architectures
Source quote
L421: PSNR / SSIM │ fastMRI │ Adv. Attack │ Tumor Cell MSE training │ 27.93 / 0.582 │ 22.82 / 0.179 │ 29.39 / 0.771 AT │ 27.20 / 0.533 │ 26.78 / 0.518 │ 27.13 / 0.560 Input Jittering │ 24.88 / 0.299 │ 24.44 / 0.297 │ 25.85 / 0.478 SPGD Jittering │ 28.15 / 0.597 │ 27.56 / 0.577 │ 29.762 / 0.777
2024Deform-Mamba (Our) proposedPSNR32.11split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965
2024FasterFC-U-Net proposedPSNR31.87subset=knee, single-coil · sampling=random Cartesian · acceleration=4Image Reconstruction for Accelerated MR Scan With Faster Fourier Convolutional Neural Networks
Source quote
L1185: 31.87
2024FasterFC-E2E-VarNet proposedPSNR39.05subset=knee, multi-coil · cascades=4 · sampling=random Cartesian · acceleration=4Image Reconstruction for Accelerated MR Scan With Faster Fourier Convolutional Neural Networks
Source quote
L1227: 0.0059 39.05 0.9165
2024Self-Guided DIP (Generalized) proposedAverage reconstruction PSNR31.77 dBsplit: test · anatomy=knee · variant=Generalized · acceleration=4x · average-images=15Analysis of Deep Image Prior and Exploiting Self-Guidance for Image Reconstruction
Source quote
L627: 31.77
2024DAPS proposedPSNR31.48subset=knee · resolution=320x320 · acceleration=4x · diffusion-model=EDMImproving Diffusion Inverse Problem Solving with Decoupled Noise Annealing
Source quote
L199: DAPS │ 31.48 │ 0.762 │ 1.57 │ 29.01 │ 0.681 │ 1.28
2024DAPS proposedPSNR29.01subset=knee · resolution=320x320 · acceleration=8x · diffusion-model=EDMImproving Diffusion Inverse Problem Solving with Decoupled Noise Annealing
Source quote
L199: DAPS │ 31.48 │ 0.762 │ 1.57 │ 29.01 │ 0.681 │ 1.28
2024HQS (Cheb preconditioner) proposedPSNR34.521acceleration-factor=4Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI Reconstruction
Source quote
L185: HQS │ 34.521 │ 33.251 │ 0.917 │ 0.902
2024HQS (Cheb preconditioner) proposedPSNR33.251acceleration-factor=16Robust Plug-and-Play Methods for Highly Accelerated Non-Cartesian MRI Reconstruction
Source quote
L185: HQS │ 34.521 │ 33.251 │ 0.917 │ 0.902
2024SAFI proposedPSNR36.43split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=4-fold · coil-setting=single-coil · patch-resolution=320×320Iteratively Refined Image Reconstruction with Learned Attentive Regularizers
Source quote
L790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860
2024SAFI proposedPSNR36.06split: test · subset=50 test images · sequence=PD · resolution=320x320 · acceleration=8-fold · coil-setting=multi-coil · patch-resolution=320×320Iteratively Refined Image Reconstruction with Learned Attentive Regularizers
Source quote
L790: SAFI │ 36.43 │ 34.92 │ 0.908 │ 0.844 │ 36.06 │ 35.36 │ 0.901 │ 0.860
2024TC-KANRecon proposedPSNR30.50acceleration-factor=4TC-KANRecon: High-Quality and Accelerated MRI Reconstruction via Adaptive KAN Mechanisms and Intelligent Feature Scaling
Source quote
L209: TC-KANRecon (Ours) │ 30.50 │ 29.16 │ 27.93 │ 26.83 │ 0.817 │ 0.691 │ 0.624 │ 0.593 │ 0.0211 │ 0.0273 │ 0.0309 │ 0.0371
2023RED-diff proposedPSNR37.1 dBsplit: val · coil=multi-coil · subset=6 validation volumes · undersampling=1D equispaced, R=4A Variational Perspective on Solving Inverse Problems with Diffusion Models
Source quote
L482: RED-diff │ 37.1 │ 33.2 │ 32.7 │ 0.114
2023McASSR (Ours; rectangle window 4×16/16×4) proposedPSNR32.52 dBsplit: test · scale=4x in-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PDRethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L483: 32.52
2023McASSR (Ours; rectangle window 4×16/16×4) proposedPSNR28.76 dBsplit: test · scale=8x out-of-scale · anatomy=knee · target-modality=FS-PD · reference-modality=PDRethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L487: 28.76
2023APMC-PnP proposedPSNR32.70 dBsplit: test · acceleration=8×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1750: APMC-PnP (ours) │ 32.70 │ 36.03
2023APMC-PnP proposedPSNR36.03 dBsplit: test · acceleration=4×Provable Probabilistic Imaging using Score-based Generative Priors
Source quote
L1750: APMC-PnP (ours) │ 32.70 │ 36.03
2023Proposed joint non-linear inversion algorithm with diffusion prior proposedPSNR34.34split: val · subset=8% ACL; 15 central slices · contrast=PD · sampling=4-fold Cartesian; swapped phase-encoding direction · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L304: Cartesian\tnote{*} │ 4 │ 30.37 │ 28.65 │ 32.43 │ 30.88 │ 23.89 │ 29.68 │ 34.34 │ 32.88
2023Proposed joint non-linear inversion algorithm with diffusion prior proposedPSNR31.55split: val · subset=15 central slices · contrast=PDFS · sampling=4-fold Gaussian · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L305: Gaussian │ 4 │ 30.24 │ 27.68 │ 30.91 │ 30.90 │ 22.36 │ 27.35 │ 31.01 │ 31.55
2023Proposed joint non-linear inversion algorithm with diffusion prior proposedPSNR31.78split: val · subset=15 central slices · contrast=PDFS · sampling=radial; 45 spokes; 11-fold acceleration · resolution=320×320 reference center regionJoint Non-Linear MRI Inversion with Diffusion Priors
Source quote
L306: Radial │ 11 │ 27.93 │ 26.70 │ 30.66 │ 30.70 │ 19.97 │ 25.55 │ 32.18 │ 31.78
2023Fed-CRFD proposedPSNR35.35 dBMain comparison; PSNR averaged over three independent trials. The passage mentions β=10…Cross-Modal Vertical Federated Learning for MRI Reconstruction
Source quote
L289: We report the MRI reconstruction performances on two datasets in Table \ref{tab1} under different settings (i.e., \beta = 10% and \beta = 2%). For FL-MRCM and FedMRI, we adopt the settings of the original papers. To alleviate the influence caused by random initialization, the average PSNR, SSIM scores and standard derivation of three independent trials are calculated for the comparing methods and our Fed-CRFD. Additionally, to measure the statistical significance of performance improvements, we conduct the paired t-test for Fed-CRFD and each baseline, and report the p-value as well. As seen, the FL methods significantly outperform Solo, which demonstrates the effectiveness of FL in leveraging multiple clients to obtain a robust global model. Compared to FedAvg, the FL-MRCM achieves almost the same PSNR and even lower SSIM scores. Such an experimental result shows that FL-MRCN cannot tackle the domain shift problem from different modalities. Due to learning the specific information of clients, FedMRI can mitigate the modal difference to some extent compared with FedAvg. Besides, the previous horizontal FL frameworks, i.e., FL-MRCM and FedMRI, have not considered the valuable information of vertical samples. In contrast, thanks to the novel design of our method, our method can effectively address the problem, which significantly improves the PSNR scores from 33.30 dB to 35.35 dB on the fastMRI dataset and from 29.86 dB to 30.95 dB on our private dataset, respectively. Furthermore, our Fed-CRFD is verified to achieve the significant improvement compared to FL-MRCM and FedMRI, i.e., the corresponding p-value < 0.05, and the comparable performance to the centralized model on our private dataset, which show the superiority of our method.
2022CRR-NN proposedPSNR40.95split: test · coil=single-coil · sequence=PD · noise_std=2e-3 · resolution=320×320 ROI · acceleration=2-foldA Neural-Network-Based Convex Regularizer for Inverse Problems
Source quote
L794: CRR-NN │ {\bf 40.95} │ 38.91 │ {\bf 0.961} │ 0.934 │ 33.99 │ 33.75 │ 0.880 │ 0.831
2022LLS (\lambda=10 (-6)) proposedPSNR31.54split: test · mask=acceleration=4, center_fraction=0.08 · coils=single-coil · lambda=1e-6 · noise_sigma=0.01 · test_images=99Improving Lipschitz-Constrained Neural Networks by Learning Activation Functions
Source quote
L625: LLS │ 31.54 │ 0.7924 │ 28.04 │ 0.7108
2022LLS (\lambda=10 (-6)) proposedPSNR38.68mask=Cartesian, acceleration=4, center_fraction=0.08 · coils=15 · lambda=1e-6 · subset=PD · noise_sigma=0.002Improving Lipschitz-Constrained Neural Networks by Learning Activation Functions
Source quote
L639: LLS │ 38.68 │ 37.96 │ 0.943 │ 0.924 │ 32.75 │ 33.61 │ 0.859 │ 0.835
2022K-Space Transformer proposedPSNR27.80sampling=uniform-1d · acceleration=5xK-Space Transformer for Undersampled MRI Reconstruction
Source quote
L271: Ours │ \multicolumn{1}{c|}{31.50} │ \multicolumn{1}{c|}{0.9528} │ \multicolumn{1}{c|}{36.32} │ 0.9848 │ \multicolumn{1}{c|}{27.80} │ \multicolumn{1}{c|}{0.7078} │ \multicolumn{1}{c|}{31.04} │ 0.8189
2022ReconFormer proposedPSNR0.3 dBacceleration-factor=8×ReconFormer: Accelerated MRI Reconstruction Using Recurrent Transformer
Source quote
L124: by 0.9 dB and 0.3 dB in 8× acceleration, respectively. While the fastMRI dataset is more challenging due to the acquisition quality, all reported improvements achieved by ReconFormer are statistically significant. We provide the detailed statistical significance test in the supplementary material.
2022FedGIMP proposedPSNR28.4 dBsplit: test · coil=single-coil · train-test-operator-shift=3x VD to 6x UDFederated Learning of Generative Image Priors for MRI Reconstruction
Source quote
L420: \multirow{1}{*}{FedGIMP} │ 35.3 │ 96.2 │ 28.4 │ 82.7 │ 46.9 │ 99.3
2022FedGIMP proposedPSNR38.4 dBsplit: test · coil=multi-coil · test-acceleration=6xFederated Learning of Generative Image Priors for MRI Reconstruction
Source quote
L542: \multirow{2}{*}{FedGIMP} │ 6x │ 38.4 │ 94.5
2021DONet proposed non-standard slicePSNR32.780 dBsplit: test · coils=multi-coil · sequence=proton-density · acceleration=5× · undersampling=1D uniformDONet: Dual-Octave Network for Fast MR Image Reconstruction
Source quote
L274: In Table~\ref{t2}, we provide reconstruction evaluations of our model on fastMRI, which is currently the largest MR image dataset. As we can see, DONet obtains the best reconstruction results among different undersampling patterns and acceleration rates. In particular, under 1D uniform undersampling patterns with 5× acceleration, our DONet improves the reconstruction PSNR from 29.992 dB to 32.780 dB and SSIM from 0.829 to 0.856, compared to the best previous state-of-the-art fusion method, ComplexMRI. Similarly, we observe that our DONet yields outstanding results on both the 1D uniform and 1D Cartesian undersampling patterns with 3× and 5× acceleration. More importantly, even without the dense connection, our DONet^\dagger achieves compelling reconstruction results compared to the state-of-the-art methods. Under the 2D radial pattern with 3× acceleration, DONet^\dagger achieves SSIM = 0.930. All the results demonstrate that our DONet preserves powerful and rich contextual information for real and imaginary data.
2021MINet proposedPSNR31.769 dBscale=2× · evaluation=average score · contrast-setting=HR T1WI auxiliary to restore LR T2WIMulti-Contrast MRI Super-Resolution via a Multi-Stage Integration Network
Source quote
L109: MINet │ {\color{red}31.769} │ {\color{red}0.709} │ {\color{red}29.819} │ {\color{red}0.601} │ {\color{red}40.549} │ {\color{red}0.983} │ {\color{red}35.032} │ {\color{red}0.948} │ {\color{red}37.997} │ {\color{red}0.980} │ {\color{red}34.219} │ {\color{red}0.956}
2021Deep Equilibrium (Grad) proposedMean PSNR32.01split: test · roi=320×320 · coil=virtual single-coil · noise=complex AWGN σ=0.01 · sampling=Cartesian · resolution=320x320 · acceleration=8×Deep Equilibrium Architectures for Inverse Problems in Imaging
Source quote
L334: PSNR │ 26.64 │ 28.45 │ 28.39 │ 29.89 │ 31.13 │ 30.97 │ 31.82 │ 31.64 │ \bf 32.01 │ 31.02 │ 31.38
2021Joint-ICNet proposedPSNR40.7split: test · reduction-factor=4Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L360: 40.7
2021Joint-ICNet proposedPSNR37.3split: test · reduction-factor=8Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L375: 37.3
2021PDNet w DC proposedPSNR32.66split: val · coil=single-coil · coverage=both contrasts · trajectory=radial · acceleration=4Density Compensated Unrolled Networks for Non-Cartesian MRI Reconstruction
Source quote
L174: PDNet w DC │ 32.66 / 0.7327 │ 33.08 / 0.7534 │ 156k
2021TDV (stochastic) proposedPSNR ↑33.5acceleration=R=4 · coil-setting=single-coil · stochastic-draws=N=32Bayesian Uncertainty Estimation of Learned Variational MRI Reconstruction
Source quote
L379: TDV (stochastic) │ 33.5 │ 0.0269 │ 0.762 │ 30.4 │ 0.0412 │ 0.662 │ 9.95
2021TDV (stochastic) proposedPSNR ↑38.9coils=Q=15 · acceleration=R=4 · coil-setting=multi-coil · stochastic-draws=N=32 · coil-sensitivities=not usedBayesian Uncertainty Estimation of Learned Variational MRI Reconstruction
Source quote
L386: TDV (stochastic) │ 38.9 │ 0.0058 │ 0.919 │ 35.2 │ 0.0123 │ 0.867 │ 9.97
2021TDV (stochastic) proposedPSNR ↑35.2coils=Q=15 · acceleration=R=8 · coil-setting=multi-coil · stochastic-draws=N=32 · coil-sensitivities=not usedBayesian Uncertainty Estimation of Learned Variational MRI Reconstruction
Source quote
L386: TDV (stochastic) │ 38.9 │ 0.0058 │ 0.919 │ 35.2 │ 0.0123 │ 0.867 │ 9.97
2021A-DPS (proposed) proposedPSNR30.2split: test · resolution=368x640 · sampling-scenario=30L · acceleration-factor=8Active Deep Probabilistic Subsampling
Source quote
L294: 30.2
2020DeepPhaseCut proposedPSNR19.820 dBsplit: test · coil=single-coil · image-type=complex-valued knee images; magnitude metrics · resolution=64×64 · oversampling-ratio=4DeepPhaseCut: Deep Relaxation in Phase for Unsupervised Fourier Phase Retrieval
Source quote
L628: DeepPhaseCut │ 19.820 │ 0.399 │ 0.042
2020Proposed Co-VeGAN proposedPSNR34.593 dBsplit: test · noise=noise-free · undersampling=30% · representation=complex-valued · sampling-pattern=1D-GCo-VeGAN: Complex-Valued Generative Adversarial Network for Compressive Sensing MR Image Reconstruction
Source quote
L296: \rule{0pt}{9pt} Proposed │ 1.7M │ 34.593 / 0.7893 │ 34.416 / 0.7870 │ 33.804 / 0.7673
2020ReconODE-LT-Euler proposedPSNR31.86split: val · subset=single-coil knee · undersampling=4xMRI Image Reconstruction via Learning Optimization Using Neural ODEs
Source quote
L141: ReconODE-LT-Euler │ 0.03M │ 31.86 │ 29.11 │ 0.7194 │ 0.6363
2020Proposed pixel-wise RL MRI reconstruction (Ours, with data consistency) proposed non-standard slicePSNR30.3split: val · coil=single-coil · subset=first 1,000 validation images · masking=random 40%MRI Reconstruction with Interpretable Pixel-Wise Operations Using Reinforcement Learning
Source quote
L339: 30.3
2020OT-cycleGAN (Proposed) proposedPSNR28.7426 dBsplit: test · coil=single-coil · subset=ESC · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4xUnpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGAN
Source quote
L485: \ │ Proposed │ 28.7426 │ 0.6758 \multirow{8}*{Multi-Coil} │ \multirow{4}*{× 4} │ Input │ 28.0524 │ 0.7616
2020OT-cycleGAN (Proposed) proposedPSNR32.1812 dBsplit: test · coil=multi-coil (15-coil) · sampling=1D Cartesian uniform random; 8% ACS · resolution=center 320×320 crop · acceleration=4xUnpaired Deep Learning for Accelerated MRI using Optimal Transport Driven CycleGAN
Source quote
L488: \ │ Proposed │ 32.1812 │ 0.8300
2019Proposed self-supervised learning (SSL; U-net inverse operator) proposedPSNR22.86 dBsplit: val · acceleration=×8Self-supervised learning of inverse problem solvers in medical imaging
Source quote
L130: PSNR │ 13.74 │ N/A │ 22.86 │ 26.72
2019PC-RNN (multi-coil) proposedPSNR39.0split: val · coil=multi-coil · acceleration=4xPyramid Convolutional RNN for MRI Reconstruction
Source quote
L134: Multi-coil │ PC-RNN │ 39.0 │ 36.5 │ 0.914 │ 0.884
2019PC-RNN (multi-coil) proposedPSNR36.5split: val · coil=multi-coil · acceleration=8xPyramid Convolutional RNN for MRI Reconstruction
Source quote
L134: Multi-coil │ PC-RNN │ 39.0 │ 36.5 │ 0.914 │ 0.884
2019PC-RNN (single-coil) proposedPSNR31.3split: val · coil=single-coil · acceleration=8xPyramid Convolutional RNN for MRI Reconstruction
Source quote
L131: Single-coil │ PC-RNN │ 32.8 │ 31.3 │ 0.743 │ 0.682
2018DeepALOHA proposedPSNR35.5181 dBcoil=single-coil · acceleration=R=3k-Space Deep Learning for Accelerated MRI
Source quote
L572: \ PSNR [dB] │ 31.0201 │ 33.3799 │ 35.5181