fastMRI

86 papers · 287 extracted observations · mri reconstruction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

22.829.335.842.3202120242026A-DPS (proposed): 30.2 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 35.8 (2021)Joint-ICNet: 37.3 (2021)Replace DC with ESPIRiT (Joint-ICNet variant): 39.4 (2021)Joint-ICNet: 40.7 (2021)Deep Equilibrium (Grad): 32.01 (2021)CRR-NN: 40.95 (2023)LLS (\lambda=10 (-6)): 31.54 (2024)aSeqDIP: 34.08 (2024)Deform-Mamba (Our): 32.11 (2024)SAFI: 36.06 (2024)SAFI: 36.43 (2024)Interleaved (self-supervised loss added during training): 31.55 (2025)DEAL: 36.21 (2025)DEAL: 36.59 (2025)MFoE: 35.4 (2025)Distilled (on-policy privileged information distillation): 24.11 (2026)Distilled (on-policy privileged information distillation): 26.0 (2026)Distilled (on-policy privileged information distillation): 27.86 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 4 of 4 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025SelfDB proposedNRMSE0.108split: test · inference-steps=4 · test-subsampling=12.5% · train-subsampling=25%A Self-Supervised Diffusion Bridge for MRI Reconstruction
Source quote
L137: SelfDB │ 0.108 │ 0.882 │ 0.036
2023JSMoCo (R=2) proposed non-standard sliceNRMSE0.0093motion=rotation ±2°, translation ±3 pixels · sequence=T2-weighted brain · acceleration=R=2JSMoCo: Joint Coil Sensitivity and Motion Correction in Parallel MRI with a Self-Calibrating Score-Based Diffusion Model
Source quote
L384: Ours ( R = 2) │ 0.0093 │ 0.0093 │ 0.0091 │ 0.0099
2023JSMoCo (R=4.8) proposed non-standard sliceNRMSE0.0101motion=rotation ±2°, translation ±3 pixels · sequence=T2-weighted brain · acceleration=R=4.8JSMoCo: Joint Coil Sensitivity and Motion Correction in Parallel MRI with a Self-Calibrating Score-Based Diffusion Model
Source quote
L386: Ours (R = 4.8) │ 0.0101 │ 0.0111 │ 0.0110 │ 0.0107
2021Joint-ICNet proposedNRMSE0.0087split: test · reduction-factor=8Joint Deep Model-Based MR Image and Coil Sensitivity Reconstruction Network (Joint-ICNet) for Fast MRI
Source quote
L374: 0.0087