EyeQ
13 papers · 39 extracted observations · image enhancement · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | FD3 SOTA frontier | 28.07 | 2024-09-01 | forward-model=proposed · evaluation-setting=synthetic-simulation · Synthetic simulation; proposed forward-model setting (the table's Ours group, distinc… | Fundus image enhancement through direct diffusion bridgesSource quoteFD3 (Ours) │ 34.57 │ 8.997 │ \add{0.805} │ 28.07 │ 6.406 │ 0.926 |
| 2 | CUNSB-RFIE | 27.61 | 2025-01-01 | resolution=256×256 · EyeQ benchmark result; dataset split is not specified. Images were center-cropped and… | CUNSB-RFIE: Context-Aware Unpaired Neural Schrödinger Bridge in Retinal Fundus Image EnhancementSource quoteOurs │ 0.858 │ 27.61 │ 0.768 │ 21.92 │ 0.649 │ 22.07 |
| 3 | VAOT | 25.253 | 2025-11-01 | Unpaired enhancement on the EyeQ test set; inputs use synthetic spot artifacts, illum… | VAOT: Vessel-Aware Optimal Transport for Retinal Fundus EnhancementSource quoteVAOT(ours) │ 0.9433 │ 25.253 │ 0.7674 │ 22.793 │ 0.6701 │ 22.287 |
| 4 | TPOT (λ_topo=1) (+1 variant) | 25.196 | 2025-01-01 | lambda_topo=1 · Topology-preserving regularization ablation for quality enhancement; λ_topo=1 is the … | TPOT: Topology Preserving Optimal Transport in Retinal Fundus Image EnhancementSource quote1 │ 0.9417 │ 25.196 |
Splittest (17)
Showing 39 of 39 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | VAOT proposed | SSIM | 0.9433 | split: test | VAOT: Vessel-Aware Optimal Transport for Retinal Fundus EnhancementSource quoteL141: VAOT(ours) │ 0.9433 │ 25.253 │ 0.7674 │ 22.793 │ 0.6701 │ 22.287 |
| 2025 | VAOT proposed | PSNR | 25.253 | split: test | VAOT: Vessel-Aware Optimal Transport for Retinal Fundus EnhancementSource quoteL141: VAOT(ours) │ 0.9433 │ 25.253 │ 0.7674 │ 22.793 │ 0.6701 │ 22.287 |
| 2025 | GFE-Net baseline | SSIM | 0.9554 | paired · evaluation=full-reference | EyeBench: A Call for More Rigorous Evaluation of Retinal Image EnhancementSource quoteL207: Full-Reference Evaluation. Overall, paired methods outperform unpaired methods. As shown in Tab.~\ref{tb:deg-exp}, paired methods, particularly GFE-Net, effectively leverage frequency information, achieving higher SSIM (0.9554, 0.7935) and PSNR (29.719, 25.012) on EyeQ and IDRID, respectively. Among unpaired methods, CycleGAN and OTEGAN demonstrate competitive performance, especially on IDRID and DRIVE, where CycleGAN leads in SSIM (0.7668, 0.6681) and PSNR (22.511, 22.696), indicating robust noise reduction and generalization on unseen datasets. In segmentation tasks (Tab.~\ref{tab-seg}), SCR-Net achieves the highest AUC (0.9227), PR (0.7783), and F1 scores (0.7) in vessel segmentation among paired methods. Unpaired models CUNSB-RFIE and OTEGAN also perform comparably, with CUNSB-RFIE achieving the highest AUC (0.9163). For lesion segmentation, GFE-Net excels in HE lesions, while unpaired models CUNSB-RFIE and OTEGAN attain high F1 scores for EX lesions, demonstrating their effectiveness in lesion preservation. |
| 2025 | GFE-Net baseline | PSNR | 29.719 | paired · evaluation=full-reference | EyeBench: A Call for More Rigorous Evaluation of Retinal Image EnhancementSource quoteL207: Full-Reference Evaluation. Overall, paired methods outperform unpaired methods. As shown in Tab.~\ref{tb:deg-exp}, paired methods, particularly GFE-Net, effectively leverage frequency information, achieving higher SSIM (0.9554, 0.7935) and PSNR (29.719, 25.012) on EyeQ and IDRID, respectively. Among unpaired methods, CycleGAN and OTEGAN demonstrate competitive performance, especially on IDRID and DRIVE, where CycleGAN leads in SSIM (0.7668, 0.6681) and PSNR (22.511, 22.696), indicating robust noise reduction and generalization on unseen datasets. In segmentation tasks (Tab.~\ref{tab-seg}), SCR-Net achieves the highest AUC (0.9227), PR (0.7783), and F1 scores (0.7) in vessel segmentation among paired methods. Unpaired models CUNSB-RFIE and OTEGAN also perform comparably, with CUNSB-RFIE achieving the highest AUC (0.9163). For lesion segmentation, GFE-Net excels in HE lesions, while unpaired models CUNSB-RFIE and OTEGAN attain high F1 scores for EX lesions, demonstrating their effectiveness in lesion preservation. |
| 2025 | OTEGAN baseline | AUC | 0.9326 | split: test · grader=NN-MobileNet · enhancement=unpaired | EyeBench: A Call for More Rigorous Evaluation of Retinal Image EnhancementSource quoteL214: For DR grading, CycleGAN achieves the highest ACC (0.7588) and ranks second in Kappa, F1, and AUC, indicating strong grading capability. However, OTEGAN surpasses CycleGAN in overall quality metrics, with the highest Kappa (0.6433), F1 (0.7228), and AUC (0.9326), suggesting greater consistency and predictive accuracy for critical assessments. In FID metrics, which evaluate image realism and diversity, OTEGAN and CycleGAN excel. OTEGAN has the lowest FID-Clip score (11.114) and second-best FID-Retfound score (28.987), indicating superior image quality. CycleGAN scores best in FID-Retfound (23.778) and second-best in FID-Clip (11.530), showing strong but slightly less consistent image realism. Expert evaluations also favor OTEGAN and CycleGAN. CycleGAN achieves the highest SPR (0.8726), while OTEGAN and CUNSB-PRIE excels in LPR and BPR, with scores of 0.8280 and 0.8981 / 0.8535. these results suggest that the SDE-based method has more stable modality generation and clinic preference. |
| 2025 | OTEGAN baseline | FID-Clip | 11.114 | split: test · backbone=Clip · enhancement=unpaired · feature-extractor=Ret-clip | EyeBench: A Call for More Rigorous Evaluation of Retinal Image EnhancementSource quoteL214: For DR grading, CycleGAN achieves the highest ACC (0.7588) and ranks second in Kappa, F1, and AUC, indicating strong grading capability. However, OTEGAN surpasses CycleGAN in overall quality metrics, with the highest Kappa (0.6433), F1 (0.7228), and AUC (0.9326), suggesting greater consistency and predictive accuracy for critical assessments. In FID metrics, which evaluate image realism and diversity, OTEGAN and CycleGAN excel. OTEGAN has the lowest FID-Clip score (11.114) and second-best FID-Retfound score (28.987), indicating superior image quality. CycleGAN scores best in FID-Retfound (23.778) and second-best in FID-Clip (11.530), showing strong but slightly less consistent image realism. Expert evaluations also favor OTEGAN and CycleGAN. CycleGAN achieves the highest SPR (0.8726), while OTEGAN and CUNSB-PRIE excels in LPR and BPR, with scores of 0.8280 and 0.8981 / 0.8535. these results suggest that the SDE-based method has more stable modality generation and clinic preference. |
| 2024 | QMix proposed | Kappa | 80.9% | Real-world noisy retinal image dataset; Best checkpoint; dataset has 18.5% Mis-L. | QMix: Quality-Aware Learning With Mixed Noise for Robust Retinal Disease DiagnosisSource quoteL343: Best │ 80.8 │ 94.1 │ 80.9 │ 84.1 │ 61.4 |
| 2024 | FD3 proposed | PSNR | 28.07 | forward-model=proposed · evaluation-setting=synthetic-simulation | Fundus image enhancement through direct diffusion bridgesSource quoteL290: FD3 (Ours) │ 34.57 │ 8.997 │ \add{0.805} │ 28.07 │ 6.406 │ 0.926 |
| 2024 | FD3 proposed | FID | 6.406 | forward-model=proposed · evaluation-setting=synthetic-simulation | Fundus image enhancement through direct diffusion bridgesSource quoteL290: FD3 (Ours) │ 34.57 │ 8.997 │ \add{0.805} │ 28.07 │ 6.406 │ 0.926 |
| 2024 | FD3 proposed | IOU | 0.926 | forward-model=proposed · evaluation-setting=synthetic-simulation | Fundus image enhancement through direct diffusion bridgesSource quoteL290: FD3 (Ours) │ 34.57 │ 8.997 │ \add{0.805} │ 28.07 │ 6.406 │ 0.926 |
| 2024 | TPOT (λ_topo=1) proposed | SSIM | 0.9417 | lambda_topo=1 | TPOT: Topology Preserving Optimal Transport in Retinal Fundus Image EnhancementSource quoteL115: 1 │ 0.9417 │ 25.196 |
| 2024 | TPOT (λ_topo=1) proposed | PSNR | 25.196 | lambda_topo=1 | TPOT: Topology Preserving Optimal Transport in Retinal Fundus Image EnhancementSource quoteL115: 1 │ 0.9417 │ 25.196 |
| 2024 | Context-Aware OT proposed non-standard slice | PSNR | 24.79 | epochs=100 · subset=1,819 high-quality images | Context-Aware Optimal Transport Learning for Retinal Fundus Image EnhancementSource quoteL122: Ours │ \textbf{24.79\textsuperscript{*}} │ \textbf{0.914\textsuperscript{*}} │ \textbf{29.47\textsuperscript{*}} │ 0.673\textsuperscript{*} │ \textbf{21.65\textsuperscript{*}} │ 0.757\textsuperscript{*} |
| 2024 | CUNSB-RFIE proposed | PSNR | 27.61 | resolution=256×256 | CUNSB-RFIE: Context-Aware Unpaired Neural Schrödinger Bridge in Retinal Fundus Image EnhancementSource quoteL170: Ours │ 0.858 │ 27.61 │ 0.768 │ 21.92 │ 0.649 │ 22.07 |
| 2024 | OTRE-GAN (λ_topo=0) ablation | SSIM | 0.9392 | lambda_topo=0 | TPOT: Topology Preserving Optimal Transport in Retinal Fundus Image EnhancementSource quoteL113: 0 (OTRE-GAN) │ 0.9392 │ 24.812 |
| 2024 | OTRE-GAN (λ_topo=0) ablation | PSNR | 24.812 | lambda_topo=0 | TPOT: Topology Preserving Optimal Transport in Retinal Fundus Image EnhancementSource quoteL113: 0 (OTRE-GAN) │ 0.9392 │ 24.812 |
| 2024 | OTEGAN baseline non-standard slice | PSNR | 23.51 | subset=1,819 high-quality images · training=official repository defaults | Context-Aware Optimal Transport Learning for Retinal Fundus Image EnhancementSource quoteL121: OTEGAN~\cite{zhu2023otre} │ 23.51 │ 0.898 │ 17.96 │ 0.601 │ 18.20 │ 0.687 |
| 2023 | OTTGAN proposed | LCR (lesion structure changed ratio) | 0.429 | subset=50 randomly selected low-quality images · evaluation=three volunteers; ophthalmologist finalized results | OTRE: Where Optimal Transport Guided Unpaired Image-to-Image Translation Meets Regularization by EnhancingSource quoteL176: OTTGAN │ 0.6996 │ 0.5105 │ 0.8995 │ 0.429 │ 0.102 │ 0.490 |
| 2023 | Proposed optimal transport-guided GAN proposed | PSNR | 19.6757 | split: test · unsupervised · subset=reject-quality images · target=good-quality images | Optimal Transport Guided Unsupervised Learning for Enhancing low-quality Retinal ImagesSource quoteL118: \Block{1-1}{Ours} │ 19.6757 │ 0.7631 |
| 2023 | Proposed optimal transport-guided GAN proposed | SSIM | 0.7631 | split: test · unsupervised · subset=reject-quality images · target=good-quality images | Optimal Transport Guided Unsupervised Learning for Enhancing low-quality Retinal ImagesSource quoteL118: \Block{1-1}{Ours} │ 19.6757 │ 0.7631 |
| 2023 | LED proposed | FIQA | 65.97 | split: test · evaluation-model=ResNet101 | Learning Enhancement From Degradation: A Diffusion Model For Fundus Image EnhancementSource quoteL110: 65.97\bf{\textcolor{orange}{(+45.39)}} |
| 2023 | QuickQual (ImageNet-pretrained DenseNet121 + SVM) proposed | AUC | 0.9687 | Original 3-class retinal image quality scoring task; EyeQ classes are Good, Usable, and… | QuickQual: Lightweight, Convenient Retinal Image Quality Scoring with Off-the-Shelf Pretrained ModelsSource quoteL13: We present QuickQual, a simple approach to RIQS, consisting of a single ``off-the-shelf'' ImageNet-pretrained Densenet121 backbone plus a Support Vector Machine (SVM). QuickQual performs very well, setting a new state-of-the-art for EyeQ (Accuracy: 88.50% vs 88.00% for MCFNet; AUC: 0.9687 vs 0.9588). This suggests that RIQS can be solved with generic ``perceptual'' features learned on natural images, as opposed to requiring DL models trained on large amounts of fundus images. Additionally, we propose a Fixed Prior linearisation scheme, that converts EyeQ from a 3-way classification to a continuous logistic regression task. For this task, we present a second model, QuickQual MEga Minified Estimator (QuickQual-MEME), that consists of only 10 parameters on top of an off-the-shelf Densenet121 and can distinguish between gradable and ungradable images with an accuracy of 89.18% (AUC: 0.9537). |
| 2023 | QuickQual-MEME (linear layer; 10 parameters) proposed | AUC | 0.9537 | Fixed Prior linearisation; binary gradable-versus-ungradable task (Bad versus Good/Usab… | QuickQual: Lightweight, Convenient Retinal Image Quality Scoring with Off-the-Shelf Pretrained ModelsSource quoteL13: We present QuickQual, a simple approach to RIQS, consisting of a single ``off-the-shelf'' ImageNet-pretrained Densenet121 backbone plus a Support Vector Machine (SVM). QuickQual performs very well, setting a new state-of-the-art for EyeQ (Accuracy: 88.50% vs 88.00% for MCFNet; AUC: 0.9687 vs 0.9588). This suggests that RIQS can be solved with generic ``perceptual'' features learned on natural images, as opposed to requiring DL models trained on large amounts of fundus images. Additionally, we propose a Fixed Prior linearisation scheme, that converts EyeQ from a 3-way classification to a continuous logistic regression task. For this task, we present a second model, QuickQual MEga Minified Estimator (QuickQual-MEME), that consists of only 10 parameters on top of an off-the-shelf Densenet121 and can distinguish between gradable and ungradable images with an accuracy of 89.18% (AUC: 0.9537). |
| 2023 | MCFNet | AUC | 0.9588 | Original 3-class retinal image quality scoring task; MCFNet uses three DenseNet121 back… | QuickQual: Lightweight, Convenient Retinal Image Quality Scoring with Off-the-Shelf Pretrained ModelsSource quoteL13: We present QuickQual, a simple approach to RIQS, consisting of a single ``off-the-shelf'' ImageNet-pretrained Densenet121 backbone plus a Support Vector Machine (SVM). QuickQual performs very well, setting a new state-of-the-art for EyeQ (Accuracy: 88.50% vs 88.00% for MCFNet; AUC: 0.9687 vs 0.9588). This suggests that RIQS can be solved with generic ``perceptual'' features learned on natural images, as opposed to requiring DL models trained on large amounts of fundus images. Additionally, we propose a Fixed Prior linearisation scheme, that converts EyeQ from a 3-way classification to a continuous logistic regression task. For this task, we present a second model, QuickQual MEga Minified Estimator (QuickQual-MEME), that consists of only 10 parameters on top of an off-the-shelf Densenet121 and can distinguish between gradable and ungradable images with an accuracy of 89.18% (AUC: 0.9537). |
| 2023 | CycleGAN baseline | Kappa | 0.5378 | backbone=ResNet-50 · translation=low2high · grader-backbone=ResNet-50 · grader-training-data=high-quality images | OTRE: Where Optimal Transport Guided Unpaired Image-to-Image Translation Meets Regularization by EnhancingSource quoteL175: CycleGAN │ 0.7148 │ 0.5378 │ 0.9083 │ 0.449 │ 0.0 │ 0.347 |
| 2023 | CycleGAN baseline | PSNR | 18.6820 | split: test · subset=reject-quality images · target=good-quality images | Optimal Transport Guided Unsupervised Learning for Enhancing low-quality Retinal ImagesSource quoteL116: \Block{1-1}{CycleGAN} │ 18.6820 │ 0.7370 |
| 2023 | CycleGAN baseline | SSIM | 0.7370 | split: test · subset=reject-quality images · target=good-quality images | Optimal Transport Guided Unsupervised Learning for Enhancing low-quality Retinal ImagesSource quoteL116: \Block{1-1}{CycleGAN} │ 18.6820 │ 0.7370 |
| 2023 | Wang et al. baseline | PSNR | 18.7705 | split: test · subset=reject-quality images · target=good-quality images | Optimal Transport Guided Unsupervised Learning for Enhancing low-quality Retinal ImagesSource quoteL117: \Block{1-1}{Wang et al.} │ 18.7705 │ 0.7335 |
| 2023 | Wang et al. baseline | SSIM | 0.7335 | split: test · subset=reject-quality images · target=good-quality images | Optimal Transport Guided Unsupervised Learning for Enhancing low-quality Retinal ImagesSource quoteL117: \Block{1-1}{Wang et al.} │ 18.7705 │ 0.7335 |
| 2022 | LesionPaste proposed | AUC | 0.7348 | 1-shot · classes=DR grade 0 vs grade 1 · anomalous-training-samples=1 | LesionPaste: One-Shot Anomaly Detection for Medical ImagesSource quoteL123: LesionPaste │ 1 │ 0.7348 │ 0.8528 │ 0.9582 │ 0.9607 │ 0.8216 │ 0.9546 |
| 2022 | LesionPaste proposed | AUC | 0.8216 | 1-shot · classes=DR grade 0 vs grades 1–4 · anomalous-training-samples=1 | LesionPaste: One-Shot Anomaly Detection for Medical ImagesSource quoteL123: LesionPaste │ 1 │ 0.7348 │ 0.8528 │ 0.9582 │ 0.9607 │ 0.8216 │ 0.9546 |
| 2022 | Fully Supervised VGG16 baseline | AUC | 0.6257 | supervised · classes=DR grade 0 vs grade 1 · backbone=VGG16 · anomalous-training-samples=1807 | LesionPaste: One-Shot Anomaly Detection for Medical ImagesSource quoteL116: \color{gray}{Fully Supervised VGG16} │ \color{gray}{1807} │ \color{gray}{0.6257} │ \color{gray}{0.8448} │ \color{gray}{0.9714} │ \color{gray}{0.9846} │ \color{gray}{0.7885} │ \color{gray}{0.9975} |
| 2022 | DevNet baseline | AUC | 0.5541 | 10-shot · classes=DR grade 0 vs grade 1 · anomalous-training-samples=10 | LesionPaste: One-Shot Anomaly Detection for Medical ImagesSource quoteL120: DevNet \cite{few-short1} │ 10 │ 0.5541 │ 0.6530 │ 0.9118 │ 0.9153 │ 0.6301 │ 0.8945 |
| 2019 | ResNet18-MCS (proposed fusion variant; called MCF-Net in the text) proposed | Accuracy | 0.9029 | split: test · variant=MCS fusion · backbone=ResNet18 | Evaluation of Retinal Image Quality Assessment Networks in Different Color-spacesSource quoteL104: ResNet18-MCS │ 0.9029 │ 0.8457 │ 0.8189 │ 0.8288 |
| 2019 | ResNet50-MCS (proposed fusion variant; called MCF-Net in the text) proposed | Accuracy | 0.9004 | split: test · variant=MCS fusion · backbone=ResNet50 | Evaluation of Retinal Image Quality Assessment Networks in Different Color-spacesSource quoteL109: ResNet50-MCS │ 0.9004 │ 0.8389 │ 0.8126 │ 0.8230 |
| 2019 | ResNet18-AVG ablation | Accuracy | 0.8966 | split: test · variant=AVG fusion · backbone=ResNet18 | Evaluation of Retinal Image Quality Assessment Networks in Different Color-spacesSource quoteL103: ResNet18-AVG │ 0.8966 │ 0.8164 │ 0.8226 │ 0.8176 |
| 2019 | ResNet50-AVG ablation | Accuracy | 0.8957 | split: test · variant=AVG fusion · backbone=ResNet50 | Evaluation of Retinal Image Quality Assessment Networks in Different Color-spacesSource quoteL108: ResNet50-AVG │ 0.8957 │ 0.8156 │ 0.8183 │ 0.8163 |
| 2019 | ResNet18-RGB baseline | Accuracy | 0.8914 | split: test · backbone=ResNet18 · color-space=RGB | Evaluation of Retinal Image Quality Assessment Networks in Different Color-spacesSource quoteL100: ResNet18-RGB │ 0.8914 │ 0.8044 │ 0.8166 │ 0.8087 |
| 2019 | ResNet50-RGB baseline | Accuracy | 0.8921 | split: test · backbone=ResNet50 · color-space=RGB | Evaluation of Retinal Image Quality Assessment Networks in Different Color-spacesSource quoteL105: ResNet50-RGB │ 0.8921 │ 0.8123 │ 0.8078 │ 0.8100 |