EyeQ
13 papers · 39 extracted observations · image enhancement · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | FD3 SOTA frontier | 28.07 | 2024-09-01 | forward-model=proposed · evaluation-setting=synthetic-simulation · Synthetic simulation; proposed forward-model setting (the table's Ours group, distinc… | Fundus image enhancement through direct diffusion bridgesSource quoteFD3 (Ours) │ 34.57 │ 8.997 │ \add{0.805} │ 28.07 │ 6.406 │ 0.926 |
| 2 | CUNSB-RFIE | 27.61 | 2025-01-01 | resolution=256×256 · EyeQ benchmark result; dataset split is not specified. Images were center-cropped and… | CUNSB-RFIE: Context-Aware Unpaired Neural Schrödinger Bridge in Retinal Fundus Image EnhancementSource quoteOurs │ 0.858 │ 27.61 │ 0.768 │ 21.92 │ 0.649 │ 22.07 |
| 3 | VAOT | 25.253 | 2025-11-01 | Unpaired enhancement on the EyeQ test set; inputs use synthetic spot artifacts, illum… | VAOT: Vessel-Aware Optimal Transport for Retinal Fundus EnhancementSource quoteVAOT(ours) │ 0.9433 │ 25.253 │ 0.7674 │ 22.793 │ 0.6701 │ 22.287 |
| 4 | TPOT (λ_topo=1) (+1 variant) | 25.196 | 2025-01-01 | lambda_topo=1 · Topology-preserving regularization ablation for quality enhancement; λ_topo=1 is the … | TPOT: Topology Preserving Optimal Transport in Retinal Fundus Image EnhancementSource quote1 │ 0.9417 │ 25.196 |
Splittest (17)
Showing 17 of 17 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | VAOT proposed | SSIM | 0.9433 | split: test | VAOT: Vessel-Aware Optimal Transport for Retinal Fundus EnhancementSource quoteL141: VAOT(ours) │ 0.9433 │ 25.253 │ 0.7674 │ 22.793 │ 0.6701 │ 22.287 |
| 2025 | VAOT proposed | PSNR | 25.253 | split: test | VAOT: Vessel-Aware Optimal Transport for Retinal Fundus EnhancementSource quoteL141: VAOT(ours) │ 0.9433 │ 25.253 │ 0.7674 │ 22.793 │ 0.6701 │ 22.287 |
| 2025 | OTEGAN baseline | AUC | 0.9326 | split: test · grader=NN-MobileNet · enhancement=unpaired | EyeBench: A Call for More Rigorous Evaluation of Retinal Image EnhancementSource quoteL214: For DR grading, CycleGAN achieves the highest ACC (0.7588) and ranks second in Kappa, F1, and AUC, indicating strong grading capability. However, OTEGAN surpasses CycleGAN in overall quality metrics, with the highest Kappa (0.6433), F1 (0.7228), and AUC (0.9326), suggesting greater consistency and predictive accuracy for critical assessments. In FID metrics, which evaluate image realism and diversity, OTEGAN and CycleGAN excel. OTEGAN has the lowest FID-Clip score (11.114) and second-best FID-Retfound score (28.987), indicating superior image quality. CycleGAN scores best in FID-Retfound (23.778) and second-best in FID-Clip (11.530), showing strong but slightly less consistent image realism. Expert evaluations also favor OTEGAN and CycleGAN. CycleGAN achieves the highest SPR (0.8726), while OTEGAN and CUNSB-PRIE excels in LPR and BPR, with scores of 0.8280 and 0.8981 / 0.8535. these results suggest that the SDE-based method has more stable modality generation and clinic preference. |
| 2025 | OTEGAN baseline | FID-Clip | 11.114 | split: test · backbone=Clip · enhancement=unpaired · feature-extractor=Ret-clip | EyeBench: A Call for More Rigorous Evaluation of Retinal Image EnhancementSource quoteL214: For DR grading, CycleGAN achieves the highest ACC (0.7588) and ranks second in Kappa, F1, and AUC, indicating strong grading capability. However, OTEGAN surpasses CycleGAN in overall quality metrics, with the highest Kappa (0.6433), F1 (0.7228), and AUC (0.9326), suggesting greater consistency and predictive accuracy for critical assessments. In FID metrics, which evaluate image realism and diversity, OTEGAN and CycleGAN excel. OTEGAN has the lowest FID-Clip score (11.114) and second-best FID-Retfound score (28.987), indicating superior image quality. CycleGAN scores best in FID-Retfound (23.778) and second-best in FID-Clip (11.530), showing strong but slightly less consistent image realism. Expert evaluations also favor OTEGAN and CycleGAN. CycleGAN achieves the highest SPR (0.8726), while OTEGAN and CUNSB-PRIE excels in LPR and BPR, with scores of 0.8280 and 0.8981 / 0.8535. these results suggest that the SDE-based method has more stable modality generation and clinic preference. |
| 2023 | Proposed optimal transport-guided GAN proposed | PSNR | 19.6757 | split: test · unsupervised · subset=reject-quality images · target=good-quality images | Optimal Transport Guided Unsupervised Learning for Enhancing low-quality Retinal ImagesSource quoteL118: \Block{1-1}{Ours} │ 19.6757 │ 0.7631 |
| 2023 | Proposed optimal transport-guided GAN proposed | SSIM | 0.7631 | split: test · unsupervised · subset=reject-quality images · target=good-quality images | Optimal Transport Guided Unsupervised Learning for Enhancing low-quality Retinal ImagesSource quoteL118: \Block{1-1}{Ours} │ 19.6757 │ 0.7631 |
| 2023 | LED proposed | FIQA | 65.97 | split: test · evaluation-model=ResNet101 | Learning Enhancement From Degradation: A Diffusion Model For Fundus Image EnhancementSource quoteL110: 65.97\bf{\textcolor{orange}{(+45.39)}} |
| 2023 | CycleGAN baseline | PSNR | 18.6820 | split: test · subset=reject-quality images · target=good-quality images | Optimal Transport Guided Unsupervised Learning for Enhancing low-quality Retinal ImagesSource quoteL116: \Block{1-1}{CycleGAN} │ 18.6820 │ 0.7370 |
| 2023 | CycleGAN baseline | SSIM | 0.7370 | split: test · subset=reject-quality images · target=good-quality images | Optimal Transport Guided Unsupervised Learning for Enhancing low-quality Retinal ImagesSource quoteL116: \Block{1-1}{CycleGAN} │ 18.6820 │ 0.7370 |
| 2023 | Wang et al. baseline | PSNR | 18.7705 | split: test · subset=reject-quality images · target=good-quality images | Optimal Transport Guided Unsupervised Learning for Enhancing low-quality Retinal ImagesSource quoteL117: \Block{1-1}{Wang et al.} │ 18.7705 │ 0.7335 |
| 2023 | Wang et al. baseline | SSIM | 0.7335 | split: test · subset=reject-quality images · target=good-quality images | Optimal Transport Guided Unsupervised Learning for Enhancing low-quality Retinal ImagesSource quoteL117: \Block{1-1}{Wang et al.} │ 18.7705 │ 0.7335 |
| 2019 | ResNet18-MCS (proposed fusion variant; called MCF-Net in the text) proposed | Accuracy | 0.9029 | split: test · variant=MCS fusion · backbone=ResNet18 | Evaluation of Retinal Image Quality Assessment Networks in Different Color-spacesSource quoteL104: ResNet18-MCS │ 0.9029 │ 0.8457 │ 0.8189 │ 0.8288 |
| 2019 | ResNet50-MCS (proposed fusion variant; called MCF-Net in the text) proposed | Accuracy | 0.9004 | split: test · variant=MCS fusion · backbone=ResNet50 | Evaluation of Retinal Image Quality Assessment Networks in Different Color-spacesSource quoteL109: ResNet50-MCS │ 0.9004 │ 0.8389 │ 0.8126 │ 0.8230 |
| 2019 | ResNet18-AVG ablation | Accuracy | 0.8966 | split: test · variant=AVG fusion · backbone=ResNet18 | Evaluation of Retinal Image Quality Assessment Networks in Different Color-spacesSource quoteL103: ResNet18-AVG │ 0.8966 │ 0.8164 │ 0.8226 │ 0.8176 |
| 2019 | ResNet50-AVG ablation | Accuracy | 0.8957 | split: test · variant=AVG fusion · backbone=ResNet50 | Evaluation of Retinal Image Quality Assessment Networks in Different Color-spacesSource quoteL108: ResNet50-AVG │ 0.8957 │ 0.8156 │ 0.8183 │ 0.8163 |
| 2019 | ResNet18-RGB baseline | Accuracy | 0.8914 | split: test · backbone=ResNet18 · color-space=RGB | Evaluation of Retinal Image Quality Assessment Networks in Different Color-spacesSource quoteL100: ResNet18-RGB │ 0.8914 │ 0.8044 │ 0.8166 │ 0.8087 |
| 2019 | ResNet50-RGB baseline | Accuracy | 0.8921 | split: test · backbone=ResNet50 · color-space=RGB | Evaluation of Retinal Image Quality Assessment Networks in Different Color-spacesSource quoteL105: ResNet50-RGB │ 0.8921 │ 0.8123 │ 0.8078 │ 0.8100 |