EyeQ
13 papers · 39 extracted observations · image enhancement · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | FD3 SOTA frontier | 28.07 | 2024-09-01 | forward-model=proposed · evaluation-setting=synthetic-simulation · Synthetic simulation; proposed forward-model setting (the table's Ours group, distinc… | Fundus image enhancement through direct diffusion bridgesSource quoteFD3 (Ours) │ 34.57 │ 8.997 │ \add{0.805} │ 28.07 │ 6.406 │ 0.926 |
| 2 | CUNSB-RFIE | 27.61 | 2025-01-01 | resolution=256×256 · EyeQ benchmark result; dataset split is not specified. Images were center-cropped and… | CUNSB-RFIE: Context-Aware Unpaired Neural Schrödinger Bridge in Retinal Fundus Image EnhancementSource quoteOurs │ 0.858 │ 27.61 │ 0.768 │ 21.92 │ 0.649 │ 22.07 |
| 3 | VAOT | 25.253 | 2025-11-01 | Unpaired enhancement on the EyeQ test set; inputs use synthetic spot artifacts, illum… | VAOT: Vessel-Aware Optimal Transport for Retinal Fundus EnhancementSource quoteVAOT(ours) │ 0.9433 │ 25.253 │ 0.7674 │ 22.793 │ 0.6701 │ 22.287 |
| 4 | TPOT (λ_topo=1) (+1 variant) | 25.196 | 2025-01-01 | lambda_topo=1 · Topology-preserving regularization ablation for quality enhancement; λ_topo=1 is the … | TPOT: Topology Preserving Optimal Transport in Retinal Fundus Image EnhancementSource quote1 │ 0.9417 │ 25.196 |
Splittest (17)
Showing 20 of 20 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | VAOT proposed | SSIM | 0.9433 | split: test | VAOT: Vessel-Aware Optimal Transport for Retinal Fundus EnhancementSource quoteL141: VAOT(ours) │ 0.9433 │ 25.253 │ 0.7674 │ 22.793 │ 0.6701 │ 22.287 |
| 2025 | VAOT proposed | PSNR | 25.253 | split: test | VAOT: Vessel-Aware Optimal Transport for Retinal Fundus EnhancementSource quoteL141: VAOT(ours) │ 0.9433 │ 25.253 │ 0.7674 │ 22.793 │ 0.6701 │ 22.287 |
| 2024 | QMix proposed | Kappa | 80.9% | Real-world noisy retinal image dataset; Best checkpoint; dataset has 18.5% Mis-L. | QMix: Quality-Aware Learning With Mixed Noise for Robust Retinal Disease DiagnosisSource quoteL343: Best │ 80.8 │ 94.1 │ 80.9 │ 84.1 │ 61.4 |
| 2024 | FD3 proposed | PSNR | 28.07 | forward-model=proposed · evaluation-setting=synthetic-simulation | Fundus image enhancement through direct diffusion bridgesSource quoteL290: FD3 (Ours) │ 34.57 │ 8.997 │ \add{0.805} │ 28.07 │ 6.406 │ 0.926 |
| 2024 | FD3 proposed | FID | 6.406 | forward-model=proposed · evaluation-setting=synthetic-simulation | Fundus image enhancement through direct diffusion bridgesSource quoteL290: FD3 (Ours) │ 34.57 │ 8.997 │ \add{0.805} │ 28.07 │ 6.406 │ 0.926 |
| 2024 | FD3 proposed | IOU | 0.926 | forward-model=proposed · evaluation-setting=synthetic-simulation | Fundus image enhancement through direct diffusion bridgesSource quoteL290: FD3 (Ours) │ 34.57 │ 8.997 │ \add{0.805} │ 28.07 │ 6.406 │ 0.926 |
| 2024 | TPOT (λ_topo=1) proposed | SSIM | 0.9417 | lambda_topo=1 | TPOT: Topology Preserving Optimal Transport in Retinal Fundus Image EnhancementSource quoteL115: 1 │ 0.9417 │ 25.196 |
| 2024 | TPOT (λ_topo=1) proposed | PSNR | 25.196 | lambda_topo=1 | TPOT: Topology Preserving Optimal Transport in Retinal Fundus Image EnhancementSource quoteL115: 1 │ 0.9417 │ 25.196 |
| 2024 | Context-Aware OT proposed non-standard slice | PSNR | 24.79 | epochs=100 · subset=1,819 high-quality images | Context-Aware Optimal Transport Learning for Retinal Fundus Image EnhancementSource quoteL122: Ours │ \textbf{24.79\textsuperscript{*}} │ \textbf{0.914\textsuperscript{*}} │ \textbf{29.47\textsuperscript{*}} │ 0.673\textsuperscript{*} │ \textbf{21.65\textsuperscript{*}} │ 0.757\textsuperscript{*} |
| 2024 | CUNSB-RFIE proposed | PSNR | 27.61 | resolution=256×256 | CUNSB-RFIE: Context-Aware Unpaired Neural Schrödinger Bridge in Retinal Fundus Image EnhancementSource quoteL170: Ours │ 0.858 │ 27.61 │ 0.768 │ 21.92 │ 0.649 │ 22.07 |
| 2023 | OTTGAN proposed | LCR (lesion structure changed ratio) | 0.429 | subset=50 randomly selected low-quality images · evaluation=three volunteers; ophthalmologist finalized results | OTRE: Where Optimal Transport Guided Unpaired Image-to-Image Translation Meets Regularization by EnhancingSource quoteL176: OTTGAN │ 0.6996 │ 0.5105 │ 0.8995 │ 0.429 │ 0.102 │ 0.490 |
| 2023 | Proposed optimal transport-guided GAN proposed | PSNR | 19.6757 | split: test · unsupervised · subset=reject-quality images · target=good-quality images | Optimal Transport Guided Unsupervised Learning for Enhancing low-quality Retinal ImagesSource quoteL118: \Block{1-1}{Ours} │ 19.6757 │ 0.7631 |
| 2023 | Proposed optimal transport-guided GAN proposed | SSIM | 0.7631 | split: test · unsupervised · subset=reject-quality images · target=good-quality images | Optimal Transport Guided Unsupervised Learning for Enhancing low-quality Retinal ImagesSource quoteL118: \Block{1-1}{Ours} │ 19.6757 │ 0.7631 |
| 2023 | LED proposed | FIQA | 65.97 | split: test · evaluation-model=ResNet101 | Learning Enhancement From Degradation: A Diffusion Model For Fundus Image EnhancementSource quoteL110: 65.97\bf{\textcolor{orange}{(+45.39)}} |
| 2023 | QuickQual (ImageNet-pretrained DenseNet121 + SVM) proposed | AUC | 0.9687 | Original 3-class retinal image quality scoring task; EyeQ classes are Good, Usable, and… | QuickQual: Lightweight, Convenient Retinal Image Quality Scoring with Off-the-Shelf Pretrained ModelsSource quoteL13: We present QuickQual, a simple approach to RIQS, consisting of a single ``off-the-shelf'' ImageNet-pretrained Densenet121 backbone plus a Support Vector Machine (SVM). QuickQual performs very well, setting a new state-of-the-art for EyeQ (Accuracy: 88.50% vs 88.00% for MCFNet; AUC: 0.9687 vs 0.9588). This suggests that RIQS can be solved with generic ``perceptual'' features learned on natural images, as opposed to requiring DL models trained on large amounts of fundus images. Additionally, we propose a Fixed Prior linearisation scheme, that converts EyeQ from a 3-way classification to a continuous logistic regression task. For this task, we present a second model, QuickQual MEga Minified Estimator (QuickQual-MEME), that consists of only 10 parameters on top of an off-the-shelf Densenet121 and can distinguish between gradable and ungradable images with an accuracy of 89.18% (AUC: 0.9537). |
| 2023 | QuickQual-MEME (linear layer; 10 parameters) proposed | AUC | 0.9537 | Fixed Prior linearisation; binary gradable-versus-ungradable task (Bad versus Good/Usab… | QuickQual: Lightweight, Convenient Retinal Image Quality Scoring with Off-the-Shelf Pretrained ModelsSource quoteL13: We present QuickQual, a simple approach to RIQS, consisting of a single ``off-the-shelf'' ImageNet-pretrained Densenet121 backbone plus a Support Vector Machine (SVM). QuickQual performs very well, setting a new state-of-the-art for EyeQ (Accuracy: 88.50% vs 88.00% for MCFNet; AUC: 0.9687 vs 0.9588). This suggests that RIQS can be solved with generic ``perceptual'' features learned on natural images, as opposed to requiring DL models trained on large amounts of fundus images. Additionally, we propose a Fixed Prior linearisation scheme, that converts EyeQ from a 3-way classification to a continuous logistic regression task. For this task, we present a second model, QuickQual MEga Minified Estimator (QuickQual-MEME), that consists of only 10 parameters on top of an off-the-shelf Densenet121 and can distinguish between gradable and ungradable images with an accuracy of 89.18% (AUC: 0.9537). |
| 2022 | LesionPaste proposed | AUC | 0.7348 | 1-shot · classes=DR grade 0 vs grade 1 · anomalous-training-samples=1 | LesionPaste: One-Shot Anomaly Detection for Medical ImagesSource quoteL123: LesionPaste │ 1 │ 0.7348 │ 0.8528 │ 0.9582 │ 0.9607 │ 0.8216 │ 0.9546 |
| 2022 | LesionPaste proposed | AUC | 0.8216 | 1-shot · classes=DR grade 0 vs grades 1–4 · anomalous-training-samples=1 | LesionPaste: One-Shot Anomaly Detection for Medical ImagesSource quoteL123: LesionPaste │ 1 │ 0.7348 │ 0.8528 │ 0.9582 │ 0.9607 │ 0.8216 │ 0.9546 |
| 2019 | ResNet18-MCS (proposed fusion variant; called MCF-Net in the text) proposed | Accuracy | 0.9029 | split: test · variant=MCS fusion · backbone=ResNet18 | Evaluation of Retinal Image Quality Assessment Networks in Different Color-spacesSource quoteL104: ResNet18-MCS │ 0.9029 │ 0.8457 │ 0.8189 │ 0.8288 |
| 2019 | ResNet50-MCS (proposed fusion variant; called MCF-Net in the text) proposed | Accuracy | 0.9004 | split: test · variant=MCS fusion · backbone=ResNet50 | Evaluation of Retinal Image Quality Assessment Networks in Different Color-spacesSource quoteL109: ResNet50-MCS │ 0.9004 │ 0.8389 │ 0.8126 │ 0.8230 |