EyeQ

13 papers · 39 extracted observations · image enhancement · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

24.625.827.128.320252026FD3: 28.07 (2024)OTRE-GAN (λ_topo=0): 24.812 (2025)TPOT (λ_topo=1): 25.196 (2025)CUNSB-RFIE: 27.61 (2025)VAOT: 25.253 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 2 of 2 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025OTEGAN baselineFID-Clip11.114split: test · backbone=Clip · enhancement=unpaired · feature-extractor=Ret-clipEyeBench: A Call for More Rigorous Evaluation of Retinal Image Enhancement
Source quote
L214: For DR grading, CycleGAN achieves the highest ACC (0.7588) and ranks second in Kappa, F1, and AUC, indicating strong grading capability. However, OTEGAN surpasses CycleGAN in overall quality metrics, with the highest Kappa (0.6433), F1 (0.7228), and AUC (0.9326), suggesting greater consistency and predictive accuracy for critical assessments. In FID metrics, which evaluate image realism and diversity, OTEGAN and CycleGAN excel. OTEGAN has the lowest FID-Clip score (11.114) and second-best FID-Retfound score (28.987), indicating superior image quality. CycleGAN scores best in FID-Retfound (23.778) and second-best in FID-Clip (11.530), showing strong but slightly less consistent image realism. Expert evaluations also favor OTEGAN and CycleGAN. CycleGAN achieves the highest SPR (0.8726), while OTEGAN and CUNSB-PRIE excels in LPR and BPR, with scores of 0.8280 and 0.8981 / 0.8535. these results suggest that the SDE-based method has more stable modality generation and clinic preference.
2024FD3 proposedFID6.406forward-model=proposed · evaluation-setting=synthetic-simulationFundus image enhancement through direct diffusion bridges
Source quote
L290: FD3 (Ours) │ 34.57 │ 8.997 │ \add{0.805} │ 28.07 │ 6.406 │ 0.926