EyeQ

13 papers · 39 extracted observations · image enhancement · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

24.625.827.128.320252026FD3: 28.07 (2024)OTRE-GAN (λ_topo=0): 24.812 (2025)TPOT (λ_topo=1): 25.196 (2025)CUNSB-RFIE: 27.61 (2025)VAOT: 25.253 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 8 of 8 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025OTEGAN baselineAUC0.9326split: test · grader=NN-MobileNet · enhancement=unpairedEyeBench: A Call for More Rigorous Evaluation of Retinal Image Enhancement
Source quote
L214: For DR grading, CycleGAN achieves the highest ACC (0.7588) and ranks second in Kappa, F1, and AUC, indicating strong grading capability. However, OTEGAN surpasses CycleGAN in overall quality metrics, with the highest Kappa (0.6433), F1 (0.7228), and AUC (0.9326), suggesting greater consistency and predictive accuracy for critical assessments. In FID metrics, which evaluate image realism and diversity, OTEGAN and CycleGAN excel. OTEGAN has the lowest FID-Clip score (11.114) and second-best FID-Retfound score (28.987), indicating superior image quality. CycleGAN scores best in FID-Retfound (23.778) and second-best in FID-Clip (11.530), showing strong but slightly less consistent image realism. Expert evaluations also favor OTEGAN and CycleGAN. CycleGAN achieves the highest SPR (0.8726), while OTEGAN and CUNSB-PRIE excels in LPR and BPR, with scores of 0.8280 and 0.8981 / 0.8535. these results suggest that the SDE-based method has more stable modality generation and clinic preference.
2023QuickQual (ImageNet-pretrained DenseNet121 + SVM) proposedAUC0.9687Original 3-class retinal image quality scoring task; EyeQ classes are Good, Usable, and…QuickQual: Lightweight, Convenient Retinal Image Quality Scoring with Off-the-Shelf Pretrained Models
Source quote
L13: We present QuickQual, a simple approach to RIQS, consisting of a single ``off-the-shelf'' ImageNet-pretrained Densenet121 backbone plus a Support Vector Machine (SVM). QuickQual performs very well, setting a new state-of-the-art for EyeQ (Accuracy: 88.50% vs 88.00% for MCFNet; AUC: 0.9687 vs 0.9588). This suggests that RIQS can be solved with generic ``perceptual'' features learned on natural images, as opposed to requiring DL models trained on large amounts of fundus images. Additionally, we propose a Fixed Prior linearisation scheme, that converts EyeQ from a 3-way classification to a continuous logistic regression task. For this task, we present a second model, QuickQual MEga Minified Estimator (QuickQual-MEME), that consists of only 10 parameters on top of an off-the-shelf Densenet121 and can distinguish between gradable and ungradable images with an accuracy of 89.18% (AUC: 0.9537).
2023QuickQual-MEME (linear layer; 10 parameters) proposedAUC0.9537Fixed Prior linearisation; binary gradable-versus-ungradable task (Bad versus Good/Usab…QuickQual: Lightweight, Convenient Retinal Image Quality Scoring with Off-the-Shelf Pretrained Models
Source quote
L13: We present QuickQual, a simple approach to RIQS, consisting of a single ``off-the-shelf'' ImageNet-pretrained Densenet121 backbone plus a Support Vector Machine (SVM). QuickQual performs very well, setting a new state-of-the-art for EyeQ (Accuracy: 88.50% vs 88.00% for MCFNet; AUC: 0.9687 vs 0.9588). This suggests that RIQS can be solved with generic ``perceptual'' features learned on natural images, as opposed to requiring DL models trained on large amounts of fundus images. Additionally, we propose a Fixed Prior linearisation scheme, that converts EyeQ from a 3-way classification to a continuous logistic regression task. For this task, we present a second model, QuickQual MEga Minified Estimator (QuickQual-MEME), that consists of only 10 parameters on top of an off-the-shelf Densenet121 and can distinguish between gradable and ungradable images with an accuracy of 89.18% (AUC: 0.9537).
2023MCFNetAUC0.9588Original 3-class retinal image quality scoring task; MCFNet uses three DenseNet121 back…QuickQual: Lightweight, Convenient Retinal Image Quality Scoring with Off-the-Shelf Pretrained Models
Source quote
L13: We present QuickQual, a simple approach to RIQS, consisting of a single ``off-the-shelf'' ImageNet-pretrained Densenet121 backbone plus a Support Vector Machine (SVM). QuickQual performs very well, setting a new state-of-the-art for EyeQ (Accuracy: 88.50% vs 88.00% for MCFNet; AUC: 0.9687 vs 0.9588). This suggests that RIQS can be solved with generic ``perceptual'' features learned on natural images, as opposed to requiring DL models trained on large amounts of fundus images. Additionally, we propose a Fixed Prior linearisation scheme, that converts EyeQ from a 3-way classification to a continuous logistic regression task. For this task, we present a second model, QuickQual MEga Minified Estimator (QuickQual-MEME), that consists of only 10 parameters on top of an off-the-shelf Densenet121 and can distinguish between gradable and ungradable images with an accuracy of 89.18% (AUC: 0.9537).
2022LesionPaste proposedAUC0.73481-shot · classes=DR grade 0 vs grade 1 · anomalous-training-samples=1LesionPaste: One-Shot Anomaly Detection for Medical Images
Source quote
L123: LesionPaste │ 1 │ 0.7348 │ 0.8528 │ 0.9582 │ 0.9607 │ 0.8216 │ 0.9546
2022LesionPaste proposedAUC0.82161-shot · classes=DR grade 0 vs grades 1–4 · anomalous-training-samples=1LesionPaste: One-Shot Anomaly Detection for Medical Images
Source quote
L123: LesionPaste │ 1 │ 0.7348 │ 0.8528 │ 0.9582 │ 0.9607 │ 0.8216 │ 0.9546
2022Fully Supervised VGG16 baselineAUC0.6257supervised · classes=DR grade 0 vs grade 1 · backbone=VGG16 · anomalous-training-samples=1807LesionPaste: One-Shot Anomaly Detection for Medical Images
Source quote
L116: \color{gray}{Fully Supervised VGG16} │ \color{gray}{1807} │ \color{gray}{0.6257} │ \color{gray}{0.8448} │ \color{gray}{0.9714} │ \color{gray}{0.9846} │ \color{gray}{0.7885} │ \color{gray}{0.9975}
2022DevNet baselineAUC0.554110-shot · classes=DR grade 0 vs grade 1 · anomalous-training-samples=10LesionPaste: One-Shot Anomaly Detection for Medical Images
Source quote
L120: DevNet \cite{few-short1} │ 10 │ 0.5541 │ 0.6530 │ 0.9118 │ 0.9153 │ 0.6301 │ 0.8945