NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

23 papers · 38 extracted observations · vision

Polyp Segmentation — mDice ↑4 papers
0.20.40.50.70.92023202420252026SegT (full model: PVT encoder with SEG and CFM): 0.81 (2023)CycleGAN-based: 0.257 (2023)CUT-seg: 0.54 (2023)MISNet: 0.764 (2025)RIDE: 0.793 (2026)

Showing 25 of 25 matching observations. (5 non-standard slices moved to bottom.)

YearMethodMetricScoreProtocol / FacetsPaper & EvidenceReading list
2026RIDE proposedmDice0.793Polyp SegmentationRIDE: Retinex-Informed Decoupling for Exposing Concealed Objects
Source quote
L282: RIDE (Ours) │ 0.793 │ 0.718 │ 0.884
2025BALR-SAM proposedDice79.30Polyp SegmentationBALR-SAM: Boundary-Aware Low-Rank Adaptation of SAM for Resource-Efficient Medical Image Segmentation
Source quote
L166: BALR-SAM (Ours) │ 80.70 │ 80.52 │ 98.91 │ 79.30 │ 79.79
2025SAMwave (SAM2 backbone; complex-valued Symmetric-b adapter) proposedmIoU0.730Polyp Segmentation · fine-tuned · adapter=complex-valued Symmetric-b · backbone=SAM2SAMwave: Wavelet-Driven Feature Enrichment for Effective Adaptation of Segment Anything Model
Source quote
L388: \multicolumn{7}{c||}{mIoU\uparrow} │ 0.595 │ 0.681 │ 0.610 │ 0.223 │ 0.603 │ \multicolumn{1}{c|}{0.622} │ 0.611 │ \multicolumn{1}{c|}{0.654} │ 0.709 │ 0.683 │ 0.720 │ \multicolumn{1}{c|}{\redtext{0.737}} │ \redtext{0.730} │ 0.676
2024MISNet proposedmDice0.764Polyp Segmentation · evaluation=unseen-dataset-generalizationMulti-scale information sharing and selection network with boundary attention for polyp segmentation
Source quote
L414: Ours │ 0.764 │ 0.686 │ 0.739 │ 0.855 │ 0.900 │ 0.012
2024CAMF (S) proposedweighted F-measure (F^w_β).760Polyp Segmentation · split: test · supervised · training-data=KvasirTowards Real Zero-Shot Camouflaged Object Segmentation Without Camouflaged Annotations
Source quote
L404: \multicolumn{1}{l|}{CAMF (S)} │ .977 │ .008 │ .973 │ \multicolumn{1}{c|}{.982} │ .760 │ .018 │ .882 │ .899
2024PSTNet (ST+FCAM+FSAM+CPM; Final) proposedmDic80.0%Polyp Segmentation · split: test · evaluation=unseen-dataset · test-images=196PSTNet: Enhanced Polyp Segmentation with Multi-scale Alignment and Frequency Domain Integration
Source quote
L362: \multirow{2}{*}{ETIS} │ mDic │ 76.5 │ 77.8 │ 79.3 │ 78.7 │ 80.0
2023SegT (full model: PVT encoder with SEG and CFM) proposedmDice0.810Polyp Segmentation · resolution=352×352 · backbone=PVT · evaluation=out-of-distribution · training-data=Kvasir + ClinicDBSegT: Separated edge-guidance transformer network for polyp segmentation
Source quote
L175: SegT (Ours) │ Transformer │ 0.814 │ 0.732 │ 0.026 │ 0.810 │ 0.732 │ 0.013 │ 0.895 │ 0.828 │ 0.008
2023ACL-Net proposedDice58.89%Polyp Segmentation · semi-supervised · labeled-data=1/4 · unlabeled-data=3/4ACL-Net: Semi-supervised Polyp Segmentation via Affinity Contrastive Learning
Source quote
L481: CVC-300, ColonDB, and ETIS. As shown in Table 3, our approach also obtains a significant improvement over the other competitors, achieving 58.89% Dice and 52.44% IoU on the most challenging ETIS dataset. Relying on our novel affinity contrastive learning (ACL) mechanism implemented
2023ACL-Net proposedIoU52.44%Polyp Segmentation · semi-supervised · labeled-data=1/4 · unlabeled-data=3/4ACL-Net: Semi-supervised Polyp Segmentation via Affinity Contrastive Learning
Source quote
L481: CVC-300, ColonDB, and ETIS. As shown in Table 3, our approach also obtains a significant improvement over the other competitors, achieving 58.89% Dice and 52.44% IoU on the most challenging ETIS dataset. Relying on our novel affinity contrastive learning (ACL) mechanism implemented
2023ACL-Net (Transformer; Ours(T)) proposedDice56.37%Polyp Segmentation · semi-supervised · backbone=transformer · labeled-data=1/4 · unlabeled-data=3/4ACL-Net: Semi-supervised Polyp Segmentation via Affinity Contrastive Learning
Source quote
L472: 56.37
2023ACL-Net (Transformer; Ours(T)) proposedIoU50.58%Polyp Segmentation · semi-supervised · backbone=transformer · labeled-data=1/4 · unlabeled-data=3/4ACL-Net: Semi-supervised Polyp Segmentation via Affinity Contrastive Learning
Source quote
L473: 50.58
2023U-Net v2 proposedDSC79.0Image SegmentationU-Net V2: Rethinking the Skip Connections of U-Net for Medical Image Segmentation
Source quote
L204: U-Net v2 (ours) │ 79.0 │ {70.5} │ 0.013
2023EndoKED-SEG proposedDice similarity coefficient (DSC)0.818Polyp SegmentationKnowledge Extraction and Distillation from Large-Scale Image-Text Colonoscopy Records Leveraging Large Language and Vision Models
Source quote
L99: 0.818
2023Polyp-SAM-B proposedDSC90.3%Polyp Segmentation · split: test · fine-tuned · backbone=SAM-BPolyp-SAM: Transfer SAM for Polyp Segmentation
Source quote
L84: DSC), and ETIS (90.3% DSC), outperforming all comparable methods. Polyp-SAM-B also achieved comparable results with other methods in CVC-ClinicalDB and Kvasir. Polyp-SAM-L achieved stateof-the-art results in CVC-300 with 92.9% DSC and 88.9% mIoU, and in ETIS with 90.5% DSC and
2023Polyp-SAM-L proposedDSC90.5%Polyp Segmentation · split: test · fine-tuned · backbone=SAM-LPolyp-SAM: Transfer SAM for Polyp Segmentation
Source quote
L84: DSC), and ETIS (90.3% DSC), outperforming all comparable methods. Polyp-SAM-B also achieved comparable results with other methods in CVC-ClinicalDB and Kvasir. Polyp-SAM-L achieved stateof-the-art results in CVC-300 with 92.9% DSC and 88.9% mIoU, and in ETIS with 90.5% DSC and
2023IC-PolypSeg ablation ID 4 (+PFR + CPFR + CFC) proposedDice0.758Polyp Segmentation · resolution=352×352Efficient Polyp Segmentation Via Integrity Learning
Source quote
L224: 4 │ + PFR + CPFR + CFC │ 0.907 │ 0.846 │ 0.938 │ 0.890 │ 0.799 │ 0.728 │ 0.758 │ 0.670 │ 0.910 │ 0.859
2022TCCNet (1/15 labeled) proposedmDice0.618Video Polyp Segmentation · split: test · semi-supervised · label_ratio=1/15TCCNet: Temporally Consistent Context-Free Network for Semi-supervised Video Polyp Segmentation
Source quote
L677: 0.618
2022SSFormer-L proposedmDic0.796Image Segmentation · split: testStepwise Feature Fusion: Local Guides Global
Source quote
L129: SSformer-L │ \multicolumn{1}{c|}{0.802} │ 0.721 │ \multicolumn{1}{c|}{0.796} │ 0.720
2021Enhanced U-Net proposedmean Dice65.07Polyp Segmentation · split: test · evaluation=cross-dataset-generalizationEnhanced U-Net: A Feature Enhancement Network for Polyp Segmentation
Source quote
L147: Ours │ 65.07 │ 58.20 │ 96.50
2021Enhanced U-Net proposedmIoU58.20Polyp Segmentation · split: test · evaluation=cross-dataset-generalizationEnhanced U-Net: A Feature Enhancement Network for Polyp Segmentation
Source quote
L147: Ours │ 65.07 │ 58.20 │ 96.50
2021MCTrans proposedDSC83.69Image SegmentationMulti-compound Transformer for Accurate Biomedical Image Segmentation
Source quote
L267: MCTrans │ 92.30 │ 86.58 │ 83.69 │ 86.20 │ 90.35
2020PraNet proposedmean Dice0.628Polyp Segmentation · split: test · evaluation=unseen-dataset generalizationPraNet: Parallel Reverse Attention Network for Polyp Segmentation
Source quote
L147: PraNet~(Ours) │ 0.628 │ 0.567 │ 0.600 │ 0.794 │ 0.841 │ 0.031
2024Proposed Dense Attention Gate and hierarchical multi-layer decoder with PVT backbone proposed non-standard slicemDice0.795Polyp Segmentation · split: test · subset=unseen dataset · repeats=3 · backbone=PVTMulti-Layer Dense Attention Decoder for Polyp Segmentation
Source quote
L185: Ours │ 0.818 │ 0.731 │ 0.795 │ 0.711 │ 0.886 │ 0.815
2022DuAT proposed non-standard sliceaverage Dice82.2%Polyp Segmentation · split: test · fine-tuned · resolution=352×352 · subset=unseen out-of-distributionDuAT: Dual-Aggregation Transformer Network for Medical Image Segmentation
Source quote
L208: Generalization Capabilities. We further evaluate the generalisation capability of our model on unseen datasets (ETIS, ColonDB, EndoScene). These three datasets have their own specific challenges and properties. For example, ColonDB is a small-scale database that contains 380 images from 15 short colonoscopy sequences. ETIS consists of 196 polyp images for early diagnosis of colorectal cancer. EndoScene is a re-annotated branch with associated polyp and background (mucosa and lumen). As seen in Table \ref{table1}, our model outperforms the existing medical segmentation baselines on all unseen datasets for all metrics. Moreover, our DuAT is able to achieve an average dice of 82.2 % on the most challenging ETIS dataset, 3.5% higher than Polyp-PVT.
2021Polyp-PVT proposed non-standard slicemDic0.787Polyp Segmentation · split: test · subset=unseen-dataset generalizationPolyp-PVT: Polyp Segmentation with Pyramid Vision Transformers
Source quote
L456: Polyp-PVT~(Ours) │ 0.808 │ 0.727 │ 0.795 │ 0.865 │ 0.913 │ 0.919 │ 0.031 │ 0.787 │ 0.706 │ 0.750 │ 0.871 │ 0.906 │ 0.910 │ 0.013