Ego4D · Gaze Estimation
73 papers · 209 extracted observations · temporal localization · Markdown · CSV · JSON API
Tasks on Ego4DAll tasks (73)Temporal Localization (16)Action Anticipation (5)Gaze Estimation (4)Object State Change Classification (4)Action Recognition (3)Long Term Action Anticipation (3)Long Term Anticipation (3)Audio Visual Speech Recognition (2)
TaskTemporal Localization (37)Action Anticipation (15)Long Term Action Anticipation (11)Gaze Estimation (8)Visual Query Localization (7)Action Recognition (6)Action Forecasting (6)
Showing 8 of 8 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | ECOGaze (H=10) proposed | F1 | 42.7 | Gaze Estimation · future-horizon=H=10 | How Much Future Helps? A Controlled Study of Future-Privileged Supervision for Causal Egocentric Gaze EstimationSource quoteL177: For ECOGaze, we deploy the H{=}5 variant for EGTEA Gaze+ (as it attains the peak F1 with higher precision and less future reliance) and the H{=}10 variant for Ego4D. Under these settings, ECOGaze performs exceptionally well. On EGTEA Gaze+, it achieves a 45.9 F1 score, outperforming all reported baselines by a significant margin. On Ego4D, it likewise achieves the highest F1 (42.7) and recall (57.6) while maintaining competitive precision. These results confirm that our framework is not just an analytical tool for studying future context, but a robust methodology for deriving highly competitive causal predictors. |
| 2026 | Causal baseline (H=0) ablation | F1 | 40.7 | Gaze Estimation · future-horizon=H=0 | How Much Future Helps? A Controlled Study of Future-Privileged Supervision for Causal Egocentric Gaze EstimationSource quoteL20: Empirically, we find that future-privileged supervision improves causal gaze prediction. Across EGTEA Gaze+ and Ego4D, F1 scores improve from the causal baseline (H{=}0) of 44.7 to 45.9, and 40.7 to 42.7, respectively. Interestingly, these gains do not scale monotonically with longer look-ahead. Instead, performance peaks within a bounded temporal regime: H{\in}[5, 10] (roughly 1.7--3.3 seconds) for EGTEA Gaze+, and H{=}10 (roughly 2.7 seconds) for Ego4D. These findings confirm the utility of future context while suggesting that its range is bounded. |
| 2025 | FedCPF proposed non-standard slice | Recall | 37.10 | Gaze Estimation · split: test | Personalized Federated Learning for Egocentric Video Gaze Estimation with Comprehensive Parameter FrezzingSource quoteL306: Similarly, a t-test for Recall showed a significant improvement for FedCPF (M = 37.10, SD = 0.28) outperformed FedSelect (M = 36.82, SD = 0.31), with \text{p-value} = 0.05. |
| 2025 | FedSelect baseline non-standard slice | Recall | 36.82 | Gaze Estimation · split: test | Personalized Federated Learning for Egocentric Video Gaze Estimation with Comprehensive Parameter FrezzingSource quoteL306: Similarly, a t-test for Recall showed a significant improvement for FedCPF (M = 37.10, SD = 0.28) outperformed FedSelect (M = 36.82, SD = 0.31), with \text{p-value} = 0.05. |
| 2023 | Lai et al. gaze-estimation method baseline | F1 score | 43.1 | Gaze Estimation | An Outlook into the Future of Egocentric VisionSource quoteL577: The future of gaze prediction in wearable devices holds immense potential to revolutionise human-computer interaction and user experience. As wearable technology becomes more advanced and pervasive, integrating accurate and real-time gaze tracking capabilities will enable seamless interactions with digital content. Wearable devices with built-in gaze prediction algorithms could offer intuitive and hands-free control, improving accessibility and usability across applications. With precise gaze tracking, wearable devices can adapt their interfaces dynamically, presenting relevant information based on the user's visual focus. Despite the advances in this area, gaze analysis still poses various challenges, including the need for large annotated datasets, subjective bias due to individual differences, handling eye blinks and data attributes like occlusion and illumination \citep{ghosh2021automatic,pathirana2022eye}. Nonetheless, even with the application of state-of-the-art techniques \citep{lai2022eye}, results are not ideal, as evidenced by the F1 scores of 44.8 and 43.1 on EGTEA Gaze+ \citep{li2021eye} and Ego4D \citep{grauman2022ego4d}, respectively. |
| 2022 | MViT+(d)+GLC (Ours; complete model) proposed non-standard slice | F1 | 43.1 | Gaze Estimation · split: test · subset=clips containing gaze fixation | In the Eye of Transformer: Global-Local Correlation for Egocentric Gaze Estimation and BeyondSource quoteL154: Ours │ 43.1 │ 57.0 │ 34.7 |
| 2022 | MViT+(d) (global embedding, without GLC) ablation non-standard slice | F1 | 41.7 | Gaze Estimation · split: test · subset=clips containing gaze fixation · variant=without GLC | In the Eye of Transformer: Global-Local Correlation for Egocentric Gaze Estimation and BeyondSource quoteL96: MViT + (d) │ 43.9 │ 59.0 │ 34.9 │ 41.7 │ 57.6 │ 32.7 |
| 2022 | I3D-R50 (best CNN model) baseline non-standard slice | F1 | 37.5 | Gaze Estimation · split: test · subset=clips containing gaze fixation · backbone=I3D-R50 | In the Eye of Transformer: Global-Local Correlation for Egocentric Gaze Estimation and BeyondSource quoteL150: I3D-R50~\cite{feichtenhofer2019slowfast} │ 37.5 │ 52.5 │ 29.2 |