Calgary-Campinas

6 papers · 20 extracted observations · mri reconstruction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

25.930.234.438.6202220242026ST-GAN: 26.82 (2022)RecurrentVarNet: 32.71 (2022)RecurrentVarNet: 36.02 (2022)Unrolled[3D]: 34.72 (2026)Unrolled[3D]: 37.74 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 9 of 9 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Unrolled[3D] proposedPSNR37.74resolution=218x170Efficient Unrolled Networks for Large-Scale 3D Inverse Problems
Source quote
L422: \colorbox[rgb]{0.7,1.0,0.7}{37.74} │ \colorbox[rgb]{0.7,1.0,0.7}{34.72}
2026Unrolled[3D] proposedPSNR34.72resolution=218x170Efficient Unrolled Networks for Large-Scale 3D Inverse Problems
Source quote
L422: \colorbox[rgb]{0.7,1.0,0.7}{37.74} │ \colorbox[rgb]{0.7,1.0,0.7}{34.72}
2023EAMRI proposedPSNR36.26 dBcontrast=T1-weighted · coil-setting=multi-coil · sampling-rate=25% · acceleration-factor=4Fast MRI Reconstruction via Edge Attention
Source quote
L192: EAMRI (Ours) │ 1.1M │ \textcolor{red}{36.26 / 0.9445 / 0.0152} │ \textcolor{red}{33.87 / 0.9111 / 0.0276}
2023RecurrentVarNet, multi-scheme training proposedpSNR5.0%split: test · training=multi-scheme · acceleration=R=8 · sampling-scheme=rectilinearOn Retrospective k-space Subsampling schemes For Deep MRI Reconstruction
Source quote
L419: \multirow{2}{*}{Calgary Campinas} │ Rectilinear │ 0.3% │ 1.6% │ -13.9% │ 1.2% │ 2.7% │ -18.5% │ 3.7% │ 5.0% │ -26.0%
2023VS-Net baselinePSNR35.62 dBcontrast=T1-weighted · coil-setting=multi-coil · sampling-rate=25% · acceleration-factor=4Fast MRI Reconstruction via Edge Attention
Source quote
L190: VS-Net │ 1.2M │ \textcolor{blue}{35.62 / 0.9372 / 0.0178} │ \textcolor{blue}{33.17 / 0.9024 / 0.0318}
2022ST-GAN proposedPSNR26.82split: test · undersampling-mask=G1D10%Fast MRI Reconstruction: How Powerful Transformers Are?
Source quote
L203: SwinMR achieved the results with the highest SSIM (SwinMR/ST-GAN: 0.882/0.855 by G1D10%) and PSNR (27.68/26.82), whereas the SSIMs and PSNRs of the results reconstructed by all transformer based GANs (ST-GAN, EES-GAN, TES-GAN) fell slightly behind (Fig.~\ref{fig:SSIM}). However, when assessed for the visual perceptional metric FID, TES-GAN achieved the best FID, followed by other transformer based GANs and the non-GAN model SwinMR.
2022SwinMR baselinePSNR27.68split: test · undersampling-mask=G1D10%Fast MRI Reconstruction: How Powerful Transformers Are?
Source quote
L203: SwinMR achieved the results with the highest SSIM (SwinMR/ST-GAN: 0.882/0.855 by G1D10%) and PSNR (27.68/26.82), whereas the SSIMs and PSNRs of the results reconstructed by all transformer based GANs (ST-GAN, EES-GAN, TES-GAN) fell slightly behind (Fig.~\ref{fig:SSIM}). However, when assessed for the visual perceptional metric FID, TES-GAN achieved the best FID, followed by other transformer based GANs and the non-GAN model SwinMR.
2021RecurrentVarNet proposedpSNR36.02split: test · acceleration=5-foldRecurrent Variational Network: A Deep Learning Inverse Problem Solver applied to the task of Accelerated MRI Reconstruction
Source quote
L287: RecurrentVarNet │ 0.9418 │ 36.02 │ 0.0038
2021RecurrentVarNet proposedpSNR32.71split: test · acceleration=10-foldRecurrent Variational Network: A Deep Learning Inverse Problem Solver applied to the task of Accelerated MRI Reconstruction
Source quote
L293: RecurrentVarNet │ 0.9073 │ 32.71 │ 0.0085