BTCV

60 papers · 128 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

79.780.581.382.02025VOILA (V-L Interaction + Random sampling): 79.9 (2025)VOILA (Ts-v2-trained, without fine-tuning): 81.4 (2025)VOILA (V-L Interaction + CAS): 81.4 (2025)SegVol (text+bbox): 81.87 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 128 of 128 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Ours (Janus1B) proposedMean Dice82.31split: val · backbone=Janus1B · validation=5-fold cross-validationSegmentation, Detection and Explanation: A Unified Framework for CT Appearance Reasoning
Source quote
L387: 86.59 │ 82.96 │ 73.74 │ 80.44 │ 65.78 │ 82.31
2026EvoML proposedDice0.837split: test · supervisedValidation-Gated ML Pipeline Synthesis with Expert-Grounded Self-Evolving Skills
Source quote
L1413: 0.837
2026RadSight-4B proposedmIoU47.540-shot · params=4B · model-size=4BRadSight: Towards Perceptually Reliable Multimodal Radiology Image Understanding
Source quote
L1213: RadSight-4B │ 47.54 │ 80.67 │ 44.57 │ 75.62
2026RadSight-4B proposedF180.670-shot · params=4B · model-size=4B · IoU-threshold=0.3RadSight: Towards Perceptually Reliable Multimodal Radiology Image Understanding
Source quote
L1213: RadSight-4B │ 47.54 │ 80.67 │ 44.57 │ 75.62
2026HSMLA-B2 proposedDice87.3%resolution=512×512 · model-variant=HSMLA-B2 · dimensionality=2DHSMLA: Hierarchical Softmax Multi-scale Linear Attention for Efficient Vision Transformers
Source quote
L364: HSMLA demonstrates strong performance across all four benchmarks. On BTCV multi-organ CT segmentation, HSMLA-B2 achieves 87.3% Dice and HD95 of 8.6\,mm with 3.2× speedup, outperforming medical-specialist baselines TransUNet (77.5% Dice, 31.7\,mm HD95) and SwinUNet (79.1% Dice, 21.6\,mm HD95). The 21% reduction in HD95 vs.\ BiFormer-B2 (10.9\,mm \rightarrow 8.6\,mm) directly demonstrates that sparse softmax refinement improves organ boundary delineation. On CAMELYON16 gigapixel WSI, HSMLA-B2 reaches 94.2% AUC with 4.1× acceleration by directing softmax attention toward tumor patches. EndoVis 2017 confirms real-time surgical applicability: HSMLA-B0 achieves 89.7% Dice at 42\,FPS with reduced memory (3.7\,GB \rightarrow 2.1\,GB) on Jetson AGX Orin. On LUNA16, HSMLA-B2 attains 95.0% sensitivity at 4\,FP/scan (+3.8% vs.\ SegFormer) with 2.9× speedup, indicating that HSMLA effectively concentrates computation on small nodule regions while preserving global anatomical context. Overall, these results confirm that HSMLA’s query-sparse softmax refinement is particularly effective in medical imaging, where it concentrates computation on small, diagnostically relevant structures (organ boundaries, tumor regions, nodules) under strict latency and memory constraints.
2026SwinUNetr baselineMean Dice82.06split: val · backbone=SwinUNetr · validation=5-fold cross-validationSegmentation, Detection and Explanation: A Unified Framework for CT Appearance Reasoning
Source quote
L382: 95.44 │ 93.39 │ 77.12 │ 74.14 │ 96.39 │ 80.12 │ 90.02 │ 82.93 │ 75.08 │ 81.02 │ 64.98 │ 82.06
2025CoSimGen proposedKID0.13Generated-image fidelity against real images; models sampled at optimal convergence; sp…CoSimGen: Controllable Diffusion Model for Simultaneous Image and Mask Generation
Source quote
L212: CoSimGen (Ours) │ 206.29 │ 0.20 │ 227.64 │ 0.74 │ 203.67 │ 0.11 │ 110.43 │ 0.63 │ 159.92 │ 0.13 │ 139.35 │ 0.53
2025CoSimGen proposedLPIPS-D0.53Generated-image fidelity against real images; models sampled at optimal convergence; sp…CoSimGen: Controllable Diffusion Model for Simultaneous Image and Mask Generation
Source quote
L212: CoSimGen (Ours) │ 206.29 │ 0.20 │ 227.64 │ 0.74 │ 203.67 │ 0.11 │ 110.43 │ 0.63 │ 159.92 │ 0.13 │ 139.35 │ 0.53
2025PGCD + DAPD (full proposed method) proposedDSC90.60%class-incremental · steps=2 · class-incremental-setting=4-4Class Incremental Medical Image Segmentation via Prototype-Guided Calibration and Dual-Aligned Distillation
Source quote
L357: Ours │ 62.19 │ 2.45 │ 329.84 │ 39 │ 1.93 │ 15.46 │ 90.60
2025VOILA (Ts-v2-trained, without fine-tuning) proposedDice81.4split: test · 0-shot · fine-tuning=none · training-dataset=Ts-v2VOILA: Complexity-Aware Universal Segmentation of CT Images by Voxel Interacting with Language
Source quote
L147: 81.4(+7.3)
2025VOILA (dataset-specific supervised) proposedDice74.1split: test · supervised · training-dataset=BTCVVOILA: Complexity-Aware Universal Segmentation of CT Images by Voxel Interacting with Language
Source quote
L150: 74.1
2025VOILA (Ts-v2-trained, without fine-tuning) proposedNSD80.9split: test · 0-shot · fine-tuning=none · training-dataset=Ts-v2VOILA: Complexity-Aware Universal Segmentation of CT Images by Voxel Interacting with Language
Source quote
L148: 80.9(+9)
2025VOILA (Ts-v2-trained, without fine-tuning) proposedHD9516.0split: test · 0-shot · fine-tuning=none · training-dataset=Ts-v2VOILA: Complexity-Aware Universal Segmentation of CT Images by Voxel Interacting with Language
Source quote
L149: 16.0(-22.2)
2025SSFMamba proposedAvg Dice82.43split: test · score=average across listed organs · modality=CTSSFMamba: Symmetry-driven Spatial-Frequency Feature Fusion for 3D Medical Image Segmentation
Source quote
L402: 95.44 │ 94.34 │ 94.07 │ 62.53 │ 76.12 │ 96.67 │ 83.93 │ 89.94 │ 86.27 │ 74.19 │ 81.97 │ 69.30 │ 68.83 │ 82.43
2025SSFMamba proposedPancreas Dice81.97%split: test · modality=CT · structure=pancreasSSFMamba: Symmetry-driven Spatial-Frequency Feature Fusion for 3D Medical Image Segmentation
Source quote
L415: Empirical Validation of Modality Independence. The consistent superiority of SSFMamba across MRI (BraTS) and CT (BTCV) benchmarks provides empirical evidence for the modality-invariant hypothesis proposed in Section I. Crucially, SSFMamba maintains its leading performance across these heterogeneous datasets without the need for tedious modality-specific hyper-parameter tuning or architecture modifications, embodying a truly 'modality-agnostic' perception paradigm. Traditional spatial features are notoriously sensitive to domain shifts arising from varied scanner protocols or organ contrasts. In contrast, our results demonstrate that the spectral domain offers a more stable representational manifold; specifically, low-frequency components representing global organ envelopes remain physically consistent across modalities. This stability is most prominent in the segmentation of low-contrast organs like the pancreas, where SSFMamba achieves a substantial performance gain (81.97% Dice). This success demonstrates the capacity to isolate distinctive spectral signatures of tissue interfaces that are typically suppressed or blurred in the spatial domain due to limited intensity resolution. By acting as an Adaptive Spectral Gate, the frequency branch prioritizes subtle mid-to-high frequency components to enhance the signal-to-noise ratio (SNR) for structural features buried in the modality-specific noise floor. This validates that spectral selectivity is a potent tool for capturing heterogeneous anatomical details across diverse clinical scenarios.
2025MambaMIM-pretrained HyMamba proposedDSC (Avg)80.16%split: val · fine-tuned · backbone=HyMamba · evaluation=five-fold-cross-validation · pretraining=MambaMIMMambaMIM: Pre-training Mamba with state space token interpolation and its application to medical image segmentation
Source quote
L522: 80.16
2025MedROV proposedmAP5079.1split: test · 0-shot · modality=CTMedROV: Towards Real-Time Open-Vocabulary Detection Across Diverse Medical Imaging Modalities
Source quote
L159: BTCV │ CT │ 9.09 │ 79.1 │ 70.01
2025DDPM_BPR-FPN (anatomically guided diffusion pretraining) proposedAverage Dice coefficient67.8linear-probe · probe=non-linear · representation=frozenMedical Semantic Segmentation with Diffusion Pretrain
Source quote
L77: \text{DDPM}_{\text{BPR}}-FPN │ 82.3 │ 85.7 │ 34.1 │ 62.0 │ 89.1 │ 60.0 │ 86.1 │ 74.0 │ 48.5 │ 53.9 │ 49.1 │ 67.8
2025AutoProSAM (P&M) proposedmDice87.15split: test · fine-tuned · classes=13 · modality=CT · dimension=3DAutoProSAM: Automated Prompting SAM for 3D Multi-Organ Segmentation
Source quote
L282: 87.15
2025MedDINOv3 proposedDSC78.79%split: val · evaluation=one-fold-of-5-fold-cross-validationMedDINOv3: How to adapt vision foundation models for medical image segmentation?
Source quote
L145: MedDINOv3 (ours) │ 87.38 │ 70.68 │ 75.28 │ 78.79 │ 77.15 │ 62.67 │ 53.01 │ 70.38
2025SHF-SAM2 proposedDice Score89.71%hardware=single GPU · patch-size=2³ · processing=3D voxelSHF: Symmetrical Hierarchical Forest with Pretrained Vision Transformer Encoder for High-Resolution Medical Segmentation
Source quote
L522: 89.71
2025MLRU++ proposedMean DSC85.20%Average across all organs.MLRU++: Multiscale Lightweight Residual UNETR++ with Attention for Efficient 3D Medical Image Segmentation
Source quote
L223: MLRU++ (Ours) │ 96.44 │ 94.96 │ 94.93 │ 65.45 │ {75.47} │ 97.16 │ 90.00 │ {90.38} │ 88.34 │ 79.71 │ 87.31 │ {73.10} │ 74.29 │ 85.20
2025MedNeXt-v2 proposedDice Similarity Coefficient (DSC)80.99split: valMedNeXt-v2: Scaling 3D ConvNeXts for Large-Scale Supervised Representation Learning in Medical Image Segmentation
Source quote
L65: MedNeXt-v2 │ 80.99 │ 88.05 │ 89.09 │ 93.39 │ 88.03
2025MedDelinea proposedmDSC87.01%fine-tuned · pretraining=ATLAS-8kMedDelinea: Scalable and Efficient Medical Image Segmentation via Controllable Diffusion Transformers
Source quote
L388: MedDelinea’s performance in fine-tuning and zero-shot learning scenarios. After fine-tuning on each dataset post ATLAS-8k pre-training, MedDelinea achieves the highest metrics, including an mDSC of 87.01% on BTCV and 82.19% on AMOS. In zero-shot learning, MedDelinea demonstrates robust generalization capabilities, leading with an mDSC of 80.01% on BTCV and 78.67% on AMOS. This suggests that MedDelinea’s architecture is adaptable and effective in transferring learned features from pre-training to new datasets.
2025MedDelinea proposedmDSC80.01%0-shot · pretraining=ATLAS-8kMedDelinea: Scalable and Efficient Medical Image Segmentation via Controllable Diffusion Transformers
Source quote
L388: MedDelinea’s performance in fine-tuning and zero-shot learning scenarios. After fine-tuning on each dataset post ATLAS-8k pre-training, MedDelinea achieves the highest metrics, including an mDSC of 87.01% on BTCV and 82.19% on AMOS. In zero-shot learning, MedDelinea demonstrates robust generalization capabilities, leading with an mDSC of 80.01% on BTCV and 78.67% on AMOS. This suggests that MedDelinea’s architecture is adaptable and effective in transferring learned features from pre-training to new datasets.
2025MedDelinea proposedmDSC77.52%split: test · few-shot · subset=1% of training data · pretraining=ATLAS-8kMedDelinea: Scalable and Efficient Medical Image Segmentation via Controllable Diffusion Transformers
Source quote
L350: 77.52
2025Models trained on filtered UKBOB proposedMean Dice Score0.8370-shot · training-data=filtered UKBOBUKBOB: One Billion MRI Labeled Masks for Generalizable 3D Medical Image Segmentation
Source quote
L461: BTCV │ 0.837 │ 5.138
2025LGMSNet proposedDice (Avg)84.103D abdominal segmentation; average across the organ categories listed in the BTCV table…LGMSNet: Thinning a medical image segmentation model via dual-level multiscale fusion
Source quote
L201: 84.10
2025LGMSNet proposedDice (Gall)79.373D abdominal segmentation; Gall is the gallbladder category in the BTCV results. The 3D…LGMSNet: Thinning a medical image segmentation model via dual-level multiscale fusion
Source quote
L200: LGMSNet │ Ours │ 9.86 │ 95.82 │ 94.84 │ 94.70 │ 79.37 │ 73.38 │ 96.99 │ 85.80 │ 90.44 │ 86.69 │ 76.15 │ 83.06
2025LGMSNet proposedParam9.86Parameter value reported for LGMSNet alongside its BTCV 3D segmentation results; the pa…LGMSNet: Thinning a medical image segmentation model via dual-level multiscale fusion
Source quote
L200: LGMSNet │ Ours │ 9.86 │ 95.82 │ 94.84 │ 94.70 │ 79.37 │ 73.38 │ 96.99 │ 85.80 │ 90.44 │ 86.69 │ 76.15 │ 83.06
2025SimCroP proposedDice80.7fine-tuned · subset=100% · backbone=3D ViT-BSimCroP: Radiograph Representation Learning with Similarity-Driven Cross-Granularity Pre-training
Source quote
L122: SimCroP\xspace (Ours) │ 93.5 │ 93.7 │ 80.7
2025Mobile U-ViT-L (3D) proposedDice78.42%split: val · 5-fold-cross-validation · backbone=ViT-L · dimensionality=3DMobile U-ViT: Revisiting large kernel and U-shaped ViT for efficient medical image segmentation
Source quote
L693: Mobile U-ViT-L (3D) │ 11.06 │ 110.88 │ 28.24 │ {78.42} │ {6.56} │ {2.18} │ {89.59} │ {85.81} │ {69.35} │ {72.20} │ {94.16} │ {83.34} │ {89.40} │ {82.60} │ {68.85} │ {73.31} │ {62.49}
20253D SEEDS proposedAchievable Dice score86.67%organ=spleen · subset=organs sufficiently large under current supervoxel setting · supervoxels=4096 · configuration=defaultExtending SEEDS to a Supervoxel Algorithm for Medical Image Analysis
Source quote
L280: 3D SEEDS │ 86.67 │ 79.75 │ 79.89 │ 43.10 │ 90.68 │ 79.06 │ 62.49 │ 50.72 │ 47.06
2025VOILA (V-L Interaction + CAS) proposedDice81.40-shot · sampling-ratio=0.1 · training-dataset=Ts-v2VOILA: Complexity-Aware Universal Segmentation of CT images by Voxel Interacting with Language
Source quote
L122: \ding{52} │ CAS │ 0.1 │ 92.1 │ 11.2 │ 81.4 │ 80.9 │ 16.0 │ 81.2 │ 71.7 │ 20.6
2025U-Net INT8 TensorRT (proposed PTQ) proposedModel size6.61 MBpost-training-quantization · GPU=NVIDIA RTX 4090 · cases=20 · model=U-Net · engine=TensorRT · precision=INT8Post-Training Quantization for 3D Medical Image Segmentation: A Practical Study on Real Inference Engines
Source quote
L11: (b) TensorRT Engine with INT8 Precision. We propose a real PTQ framework using NVIDIA TensorRT to convert FP32 models into INT8, enabling notable reductions in both model size and inference latency without compromising performance. For example, U-Net's model size shrinks from 23.11 MB to 6.61 MB, and its inference latency drops from 2.62 ms to 1.05 ms, while maintaining the same mean Dice Score (mDSC) of 0.822.
2025U-Net INT8 TensorRT (proposed PTQ) proposedInference latency1.05 mspost-training-quantization · GPU=NVIDIA RTX 4090 · cases=20 · model=U-Net · engine=TensorRT · precision=INT8Post-Training Quantization for 3D Medical Image Segmentation: A Practical Study on Real Inference Engines
Source quote
L11: (b) TensorRT Engine with INT8 Precision. We propose a real PTQ framework using NVIDIA TensorRT to convert FP32 models into INT8, enabling notable reductions in both model size and inference latency without compromising performance. For example, U-Net's model size shrinks from 23.11 MB to 6.61 MB, and its inference latency drops from 2.62 ms to 1.05 ms, while maintaining the same mean Dice Score (mDSC) of 0.822.
2025U-Net INT8 TensorRT (proposed PTQ) proposedmDSC0.822post-training-quantization · cases=20 · model=U-Net · engine=TensorRT · classes=13 · precision=INT8Post-Training Quantization for 3D Medical Image Segmentation: A Practical Study on Real Inference Engines
Source quote
L11: (b) TensorRT Engine with INT8 Precision. We propose a real PTQ framework using NVIDIA TensorRT to convert FP32 models into INT8, enabling notable reductions in both model size and inference latency without compromising performance. For example, U-Net's model size shrinks from 23.11 MB to 6.61 MB, and its inference latency drops from 2.62 ms to 1.05 ms, while maintaining the same mean Dice Score (mDSC) of 0.822.
2025HyMamba (trained from scratch; no pre-training) ablationDSC (Avg)77.56%split: val · fine-tuned · backbone=HyMamba · evaluation=five-fold-cross-validation · pretraining=noneMambaMIM: Pre-training Mamba with state space token interpolation and its application to medical image segmentation
Source quote
L509: 77.56
2025SegVol (text+bbox) ablationDice81.870-shot · prompt=text+bboxZero-shot Domain Generalization of Foundational Models for 3D Medical Image Segmentation: An Experimental Study
Source quote
L198: \keypoint{Text inputs boost spatial prompts.} We investigate the effect of semantic prompts as an additional guidance alongside spatial prompts for SegVol~\cite{segvol}, denoted by ``text+bbox'' and ``text+points'' in \autoref{tab:sec4p3}. Comparing them with corresponding vanilla spatial prompts in \autoref{tab:sec4p2}, we notice that for known anatomies (abdominal CT and MR), the addition of text consistently improves segmentations from raw spatial prompts (BTCV: 80.15 w/ bbox, 81.87 w/ text+bbox; CHAOS: 80.25 w/ points, 81.06 w/ text+points). We show example segmentation results in \autoref{fig:bbox_text}. For unseen anatomies, text prompts completely fail, since the model has no knowledge to spatially ground such concepts.
2025Step 0 U-Net (RFMedSAM 2 prompt-generation pipeline) ablationDSC0.856split: val · stage=Step 0 U-NetRFMedSAM 2: Automatic Prompt Refinement for Enhanced Volumetric Medical Image Segmentation with SAM 2
Source quote
L259: Dataset │ Step 0 - UNet │ Step 1 - SAM │ Step 2 - SAM BTCV │ 0.856 │ 0.864 │ 0.867
2025VOILA (V-L Interaction + Random sampling) ablationDice79.90-shot · sampling-ratio=0.1 · training-dataset=Ts-v2 · sampling-strategy=randomVOILA: Complexity-Aware Universal Segmentation of CT images by Voxel Interacting with Language
Source quote
L125: \ding{52} │ Random │ 0.1 │ 91.5 │ 12.8 │ 79.9 │ 79.5 │ 19.5 │ 80.4 │ 71.5 │ 19.5
2025SDR baselineDSC89.34%class-incremental · steps=2 · class-incremental-setting=4-4Class Incremental Medical Image Segmentation via Prototype-Guided Calibration and Dual-Aligned Distillation
Source quote
L353: SDR │ 62.19 │ 2.45 │ 329.84 │ 35 │ 1.86 │ 18.03 │ 89.34
2025EM-Net 2024 baselineAvg Dice81.55split: test · score=average across listed organs · modality=CTSSFMamba: Symmetry-driven Spatial-Frequency Feature Fusion for 3D Medical Image Segmentation
Source quote
L395: 92.43 │ 91.57 │ 90.34 │ 67.65 │ 75.13 │ 95.84 │ 83.98 │ 90.66 │ 86.47 │ 73.03 │ 74.98 │ 70.10 │ 68.09 │ 81.55
2025UNETR++ baselinemean DSC83.28split: test · subjects=20Advancing Medical Image Segmentation via Self-supervised Instance-adaptive Prototype Learning
Source quote
L162: UNETR++ │ 94.94 │ 91.90 │ 93.62 │ 70.75 │ 77.18 │ 95.95 │ 85.15 │ 89.28 │ 83.14 │ 76.91 │ 77.42 │ 72.56 │ 68.17 │ 83.28
2025SegVol (bbox) baselineDice80.150-shot · prompt=bounding-boxZero-shot Domain Generalization of Foundational Models for 3D Medical Image Segmentation: An Experimental Study
Source quote
L198: \keypoint{Text inputs boost spatial prompts.} We investigate the effect of semantic prompts as an additional guidance alongside spatial prompts for SegVol~\cite{segvol}, denoted by ``text+bbox'' and ``text+points'' in \autoref{tab:sec4p3}. Comparing them with corresponding vanilla spatial prompts in \autoref{tab:sec4p2}, we notice that for known anatomies (abdominal CT and MR), the addition of text consistently improves segmentations from raw spatial prompts (BTCV: 80.15 w/ bbox, 81.87 w/ text+bbox; CHAOS: 80.25 w/ points, 81.06 w/ text+points). We show example segmentation results in \autoref{fig:bbox_text}. For unseen anatomies, text prompts completely fail, since the model has no knowledge to spatially ground such concepts.
2025BioMedParse baselinemAP509.09split: test · 0-shot · modality=CTMedROV: Towards Real-Time Open-Vocabulary Detection Across Diverse Medical Imaging Modalities
Source quote
L159: BTCV │ CT │ 9.09 │ 79.1 │ 70.01
2025MedSAM (Full) baselinemDice84.57split: test · fine-tuned · classes=13 · modality=CT · dimension=3DAutoProSAM: Automated Prompting SAM for 3D Multi-Organ Segmentation
Source quote
L276: 84.57
2025nnU-Net baselineDSC73.30%split: val · evaluation=one-fold-of-5-fold-cross-validationMedDINOv3: How to adapt vision foundation models for medical image segmentation?
Source quote
L142: nnU-Net │ 84.81 │ 69.15 │ 75.00 │ 73.30 │ 73.98 │ 64.85 │ 53.02 │ 64.66
2025SAM2 baselineDice Score82.77%hardware=single GPU · patch-size=4³ · processing=3D voxelSHF: Symmetrical Hierarchical Forest with Pretrained Vision Transformer Encoder for High-Resolution Medical Segmentation
Source quote
L517: 82.77
2025M3AE baselineDice80.5fine-tuned · subset=100% · backbone=3D ViT-BSimCroP: Radiograph Representation Learning with Similarity-Driven Cross-Granularity Pre-training
Source quote
L117: M3AE~\cite{chen2022m3ae} │ 93.1 │ 93.7 │ 80.5
2025SLIC baselineAchievable Dice score81.60%organ=spleen · subset=organs sufficiently large under current supervoxel setting · supervoxels=4096Extending SEEDS to a Supervoxel Algorithm for Medical Image Analysis
Source quote
L279: SLIC~\cite{6205760} │ 81.60 │ 79.02 │ 80.24 │ 30.89 │ 87.88 │ 73.25 │ 51.32 │ 31.59 │ 22.76
2025U-Net FP32 reference baselineModel size23.11 MBGPU=NVIDIA RTX 4090 · cases=20 · model=U-Net · classes=13 · precision=FP32Post-Training Quantization for 3D Medical Image Segmentation: A Practical Study on Real Inference Engines
Source quote
L11: (b) TensorRT Engine with INT8 Precision. We propose a real PTQ framework using NVIDIA TensorRT to convert FP32 models into INT8, enabling notable reductions in both model size and inference latency without compromising performance. For example, U-Net's model size shrinks from 23.11 MB to 6.61 MB, and its inference latency drops from 2.62 ms to 1.05 ms, while maintaining the same mean Dice Score (mDSC) of 0.822.
2025U-Net FP32 reference baselineInference latency2.62 msGPU=NVIDIA RTX 4090 · cases=20 · model=U-Net · classes=13 · precision=FP32Post-Training Quantization for 3D Medical Image Segmentation: A Practical Study on Real Inference Engines
Source quote
L11: (b) TensorRT Engine with INT8 Precision. We propose a real PTQ framework using NVIDIA TensorRT to convert FP32 models into INT8, enabling notable reductions in both model size and inference latency without compromising performance. For example, U-Net's model size shrinks from 23.11 MB to 6.61 MB, and its inference latency drops from 2.62 ms to 1.05 ms, while maintaining the same mean Dice Score (mDSC) of 0.822.
2025U-Net FP32 reference baselinemDSC0.822cases=20 · model=U-Net · classes=13 · precision=FP32Post-Training Quantization for 3D Medical Image Segmentation: A Practical Study on Real Inference Engines
Source quote
L11: (b) TensorRT Engine with INT8 Precision. We propose a real PTQ framework using NVIDIA TensorRT to convert FP32 models into INT8, enabling notable reductions in both model size and inference latency without compromising performance. For example, U-Net's model size shrinks from 23.11 MB to 6.61 MB, and its inference latency drops from 2.62 ms to 1.05 ms, while maintaining the same mean Dice Score (mDSC) of 0.822.
2024MOSMOS + U-Net (ResNet-50) proposedAvg. Dice80.10%split: test · fine-tuned · backbone=ResNet-50 · architecture=U-NetMOSMOS: Multi-organ segmentation facilitated by medical report supervision
Source quote
L267: MOSMOS~(Ours) │ 94.36 │ 93.56 │ 93.81 │ 73.01 │ 72.24 │ 96.11 │ 81.85 │ 89.04 │ 83.72 │ 60.74 │ 76.16 │ 64.95 │ \multicolumn{1}{l|}{61.68} │ 80.10
2024Mamba-3D-UNETR-S proposedDICE83.1split: val · subset=split0 · patch-size=16×16×16 · resolution=16x16 · training-samples=24 · validation-samples=6Mamba-ND: Selective State Space Modeling for Multi-dimensional Data
Source quote
L283: Mamba-3D-UNETR-S │ Mamba │ 36M │ 83.1 │ 8G │ [16, 16, 16]
2024nnUNet + Pool Skip proposedDICE82.47%split: test · five-fold-cross-validation · model=nnUNet · variant=Pool Skip · test-scans=12Beyond Skip Connection: Pooling and Unpooling Design for Elimination Singularities
Source quote
L285: \ \ \ \ +ours │ 82.47 \textcolor[rgb]{ 1, 0, 0}{+0.95} │ 77.00 \textcolor[rgb]{ 1, 0, 0}{+0.90} │ 73.08 \textcolor[rgb]{ 1, 0, 0}{+0.94}
2024Probabilistic-aware weakly supervised pipeline proposedDice↑0.8279semi-supervised · organ=spleen · supervision=point annotations · pseudo-labeling=probabilisticEnhancing Weakly Supervised 3D Medical Image Segmentation through Probabilistic-aware Learning
Source quote
L308: Ours │ 0.8279 │ 0.8157 │ 0.7599 │ 0.7164 │ 63.09 │ 127.16 │ 135.88 │ 116.22
2024APF-UNETR proposedDice89.7%hardware=1 GPU · resolution=512×512Adaptive Patching for High-resolution Image Segmentation with Transformers
Source quote
L593: APF-UNETR │ 2 │ 1067.88 Sec │ 1× │ 89.7
2024LTUDA proposedaverage Dice89.98%evaluation=external-generalization · training-data=LSPLLabeled-to-unlabeled distribution alignment for partially-supervised multi-organ medical image segmentation
Source quote
L346: LTUDA (Ours) │ 95.98 │ 95.18 │ 88.69 │ 80.06 │ 89.98 │ 15.34 │ 4.85 │ 16.11 │ 14.14 │ 12.61
2024LoGoNet proposedAverage Dice accuracy.854AVG column; BTCV analysis. The table also lists Gall, Eso, Veins and Lad; the paper rep…Masked LoGoNet: Fast and Accurate 3D Image Analysis for Medical Domain
Source quote
L369: LoGoNet │ .818 │ .786 │ .769 │ .698 │ .854
2024Our SSL Approach (LoGoNet initialized with pre-training) proposedAverage Dice accuracy.875pretraining-clusters=80Masked LoGoNet: Fast and Accurate 3D Image Analysis for Medical Domain
Source quote
L387: Our SSL Approach │ .866 │ .845 │ .791 │ .757 │ .875
2024PrimGeoSeg (SwinUNETR; 5K FDSL pre-training) proposedAvg. Dice score82.0fine-tuned · backbone=SwinUNETR · pretraining=FDSL · pretraining-data=5KPrimitive Geometry Segment Pre-training for 3D Medical Image Segmentation
Source quote
L274: PrimGeoSeg │ 5K │ FDSL │ 82.0 │ 95.7 │ 94.4 │ 94.4 │ 61.0 │ 75.5 │ 96.7 │ 83.3 │ 89.1 │ 85.6 │ 75.2 │ 84.3 │ 67.9 │ 62.4 \\[0.8pt]
2024RevSAM2 proposedmDSC69.03%few-shot · organ_subset=13 organs, excluding veins · support_dataset=AbdomenCTFS-MedSAM2: Exploring the Potential of SAM2 for Few-Shot Medical Image Segmentation without Fine-tuning
Source quote
L229: Ours │ \multicolumn{1}{c|}{71.01} │ 69.03 │ \multicolumn{1}{c|}{82.46} │ 77.47
2024Ours (Feat. ✓, Decorr. ✓) proposedMean Dice Score51.86%frozen · training-data=100% · pretraining-dataset=AbdomenCT-1KOvercoming Dimensional Collapse in Self-Supervised Contrastive Learning for Medical Image Segmentation
Source quote
L116: Ours │ \checkmark │ \checkmark │ 51.86 │ 79.38 │ 81.22
2024Ours (Feat. ✓, Decorr. ✓) proposedMean Dice Score79.38%fine-tuned · training-data=100% · pretraining-dataset=AbdomenCT-1KOvercoming Dimensional Collapse in Self-Supervised Contrastive Learning for Medical Image Segmentation
Source quote
L116: Ours │ \checkmark │ \checkmark │ 51.86 │ 79.38 │ 81.22
2024Ours (Feat. ✓, Decorr. ✓) proposedMean Dice Score81.22%fine-tuned · training-data=100% · pretraining-dataset=AbdomenCT-1KOvercoming Dimensional Collapse in Self-Supervised Contrastive Learning for Medical Image Segmentation
Source quote
L116: Ours │ \checkmark │ \checkmark │ 51.86 │ 79.38 │ 81.22
2024LoGoNet + PRE (w/ M) ablationDice accuracy (Gall).866pretraining-masking=with maskingMasked LoGoNet: Fast and Accurate 3D Image Analysis for Medical Domain
Source quote
L466: LoGoNet + PRE │ .866 │ .845 │ .845 │ .802 │ .851 │ .820
2024Tri-Plane Mamba (TP-Mamba), tri-plane scan variant ablationDice78.7scan-variant=tri-plane · training-data=25%Tri-Plane Mamba: Efficiently Adapting Segment Anything Model for 3D Medical Images
Source quote
L747: Volume 73.9 hw-plane 74.4 dw-plane 76.5 tri-plane 78.7
2024Tri-Plane Mamba (TP-Mamba), volume-scan variant ablationDice73.9scan-variant=volume · training-data=25%Tri-Plane Mamba: Efficiently Adapting Segment Anything Model for 3D Medical Images
Source quote
L747: Volume 73.9 hw-plane 74.4 dw-plane 76.5 tri-plane 78.7
2024Tri-Plane Mamba (TP-Mamba), hw-plane scan variant ablationDice74.4scan-variant=hw-plane · training-data=25%Tri-Plane Mamba: Efficiently Adapting Segment Anything Model for 3D Medical Images
Source quote
L747: Volume 73.9 hw-plane 74.4 dw-plane 76.5 tri-plane 78.7
2024Tri-Plane Mamba (TP-Mamba), dw-plane scan variant ablationDice76.5scan-variant=dw-plane · training-data=25%Tri-Plane Mamba: Efficiently Adapting Segment Anything Model for 3D Medical Images
Source quote
L747: Volume 73.9 hw-plane 74.4 dw-plane 76.5 tri-plane 78.7
2024Tri-Plane Mamba (TP-Mamba), multi-scale 3D conv adapter with k=3 ablationDice78.9adapter=multi-scale 3D convolution · kernel-size=3 · training-data=25%Tri-Plane Mamba: Efficiently Adapting Segment Anything Model for 3D Medical Images
Source quote
L742: MS conv (k=3) 78.9 conv (k=5)
2024Tri-Plane Mamba (TP-Mamba), single 3D conv adapter with k=3 ablationDice75.1adapter=single 3D convolution · kernel-size=3 · training-data=25%Tri-Plane Mamba: Efficiently Adapting Segment Anything Model for 3D Medical Images
Source quote
L741: 75.1
2024VAFA non-standard sliceASR-D56.17%split: val · resolution=32x32On Evaluating Adversarial Robustness of Volumetric Medical Segmentation Models
Source quote
L71: \texttt{VAFA} │ 56.23 │ 77.60 │ 58.84 │ 64.02 │ 45.85 │ 43.75 │ 53.77 │ 52.37 │ 61.72 │ 70.92 │ 60.61 │ 80.24 │ 56.17 │ 64.82
2024CosPGD non-standard sliceASR-D41.33%split: valOn Evaluating Adversarial Robustness of Volumetric Medical Segmentation Models
Source quote
L70: \texttt{CosPGD} │ 43.21 │ 66.74 │ 61.16 │ 18.60 │ 25.07 │ 36.06 │ 25.14 │ 48.45 │ 47.41 │ 74.63 │ 45.96 │ 68.58 │ 41.33 │ 52.18
2024ImageNet + U-Net (ResNet-50) baselineAvg. Dice76.73%split: test · fine-tuned · backbone=ResNet-50 · architecture=U-NetMOSMOS: Multi-organ segmentation facilitated by medical report supervision
Source quote
L260: ImageNet~\cite{deng2009imagenet} │ 92.87 │ 91.16 │ 91.87 │ 60.00 │ 69.83 │ 96.19 │ 71.08 │ 89.80 │ 81.84 │ 67.59 │ 73.99 │ 58.03 │ \multicolumn{1}{l|}{53.20} │ 76.73
2024UNETR baselineDICE81.4split: val · subset=split0 · backbone=ViT · patch-size=16×16×16 · resolution=16x16Mamba-ND: Selective State Space Modeling for Multi-dimensional Data
Source quote
L280: UNETR │ ViT │ 101M │ 81.4 │ 10G │ [16, 16, 16]
2024nnUNet (no Pool Skip) baselineDICE81.52%split: test · five-fold-cross-validation · model=nnUNet · variant=no Pool Skip · test-scans=12Beyond Skip Connection: Pooling and Unpooling Design for Elimination Singularities
Source quote
L284: } │ 81.52 │ 76.10 │ 72.14
2024ResT image encoder with RFF baselinemDSC61.5method=RFF · encoder=ResTTowards a Comprehensive, Efficient and Promptable Anatomic Structure Segmentation Model Using 3D Whole-Body CT Scans
Source quote
L259: ResT │ \checkmark │ 73.1 │ 81.4 │ 61.5 │ 72.8
2024UNETR baselineDice89.1%hardware=1 GPU · patch-size=4 · resolution=512×512Adaptive Patching for High-resolution Image Segmentation with Transformers
Source quote
L589: UNETR~\cite{hatamizadeh2022unetr} │ 4 │ 8386.56 Sec │ 7.85× │ 89.1
2024Swin UNETR* baselineDice91.8%fine-tuned · hardware=1 GPU · patch-size=4 · resolution=512×512 · pretraining=five datasetsAdaptive Patching for High-resolution Image Segmentation with Transformers
Source quote
L591: Swin UNETR (*)~\cite{DBLP:conf/cvpr/TangY0RLXNH22} │ 4 │ 6609.45 Sec │ 6.19× │ 91.8
2024ULKANet (single feature extractor) baselineAverage Dice accuracy.824AVG column; single-feature-extractor comparison with LoGoNet in the BTCV analysis. The …Masked LoGoNet: Fast and Accurate 3D Image Analysis for Medical Domain
Source quote
L368: ULKANet │ .761 │ .782 │ .690 │ .684 │ .824
2024Scratch (SwinUNETR; no pre-training) baselineAvg. Dice score78.3fine-tuned · backbone=SwinUNETR · pretraining=nonePrimitive Geometry Segment Pre-training for 3D Medical Image Segmentation
Source quote
L272: Scratch │ 0 │ -- │ 78.3 │ 92.3 │ 93.2 │ 93.8 │ 55.9 │ 61.3 │ 94.0 │ 77.0 │ 87.5 │ 80.4 │ 74.2 │ 76.1 │ 68.8 │ 63.6
2024V-Net (UB) baseline non-standard sliceAVG Dice76.28%fully-supervised · evaluation=average across organ classes · labeled-unlabeled=18/0Concatenate, Fine-tuning, Re-training: A SAM-enabled Framework for Semi-supervised 3D Medical Image Segmentation
Source quote
L524: 18 / 0 │ V-Net\scalebox{0.7}{~\cite{milletari2016v} (UB)} │ 76.28 │ 84.00 │ 84.82 │ 86.38 │ 67.42 │ 65.02 │ 94.83 │ 73.75 │ 90.27 │ 84.19 │ 69.85 │ 63.54 │ 62.60 │ 65.02
2024MoCo v2 baselineMean Dice Score44.30%frozen · training-data=100% · pretraining-dataset=AbdomenCT-1KOvercoming Dimensional Collapse in Self-Supervised Contrastive Learning for Medical Image Segmentation
Source quote
L113: MoCo v2 │ 44.30 │ 78.21 │ 81.09
2024MoCo v2 baselineMean Dice Score78.21%fine-tuned · training-data=100% · pretraining-dataset=AbdomenCT-1KOvercoming Dimensional Collapse in Self-Supervised Contrastive Learning for Medical Image Segmentation
Source quote
L113: MoCo v2 │ 44.30 │ 78.21 │ 81.09
2024MoCo v2 baselineMean Dice Score81.09%fine-tuned · training-data=100% · pretraining-dataset=AbdomenCT-1KOvercoming Dimensional Collapse in Self-Supervised Contrastive Learning for Medical Image Segmentation
Source quote
L113: MoCo v2 │ 44.30 │ 78.21 │ 81.09
2023DAE proposedHD (Hausdorff Distance)16.82split: test · ensemble=four rounds of five-fold cross-validation · resolution=1×1×1 mmDisruptive Autoencoders: Leveraging Low-level features for 3D Medical Image Pre-training
Source quote
L138: DAE (Ours) │ 16.82 │ 0.654 │ 0.921
2023DAE proposedMSD (Mean Surface Distance)0.654split: test · ensemble=four rounds of five-fold cross-validation · resolution=1×1×1 mmDisruptive Autoencoders: Leveraging Low-level features for 3D Medical Image Pre-training
Source quote
L138: DAE (Ours) │ 16.82 │ 0.654 │ 0.921
2023DAE proposedDice0.921split: test · ensemble=four rounds of five-fold cross-validation · resolution=1×1×1 mmDisruptive Autoencoders: Leveraging Low-level features for 3D Medical Image Pre-training
Source quote
L138: DAE (Ours) │ 16.82 │ 0.654 │ 0.921
2023FedASAM* proposedDice75.14federated · client=4 · distribution=out-FL · local-rounds=1 · post-processing=none · communication-rounds=500UFPS: A unified framework for partially annotated federated segmentation in heterogeneous data distribution
Source quote
L375: FedASAM* │ 77.02 / 1.39 │ 78.15 / 2.91 │ 65.60 / 1.75 │ 75.14 / 1.71 │ 73.97 / 1.94 │ 74.20 / 1.63
2023COSST proposedAverage Dice score (DSC)87.76%task=Task 1COSST: Multi-Organ Segmentation With Partially Labeled Datasets Using Comprehensive Supervisions and Self-Training
Source quote
L333: In Tab. \ref{tab4}, we show the segmentation performance of the compared methods for the public datasets in task1. First, we observe that it is more beneficial to learn a single unified model from partially labeled datasets than the baseline Multi-Nets, especially for the organs whose training set is small, e.g., spleen (N=20). For example, by comparing the Multi-Nets to the proposed COSST, we can observe that the average Dice score improves from 86.25% to 89.08%, the average HD95 improves from 16.85 to 5.36, and the average ASD improves from 3.38 to 1.16. By comparing the segmentation performance across three evaluated datasets, we notice that the segmentation performance of all compared methods decreases from the held-out testing set to the external datasets, e.g., the average Dice score of COSST drops from 92.13% to 87.76% and 87.37% for BTCV and AMOS2022, respectively. However, we find that COSST consistently yields more reliable segmentation results than other methods under the domain shift. For instance, by the comparing the COSST to the second best approach, we show that the segmentation results of COSST have much better boundary matching, i.e., 6.23 vs. 11.24 and 6.29 vs. 11.01 respectively for BTCV and AMOS2022. For ground truth based supervision methods, we observe that TAL and ME achieve comparable results in Dice scores but TAL slightly outperforms ME in HD95 and ASD. In addition, we notice that the pseudo-label based methods such as PLT and co-training achieve better segmentation performance than the non-pseudo label based methods, i.e., TAL and ME, demonstrating the importance of the pseudo label learning. Furthermore, comparing the pseudo label based methods (e.g., PLT) to our proposed COSST, we observe that COSST not only achieves overall higher Dice scores, but also much better performance in distance-based metrics HD95 and ASD (ASD: 1.16 vs. 2.51, and HD95: 5.36 vs. 14.91), indicating the effectiveness of our strategy for pseudo label learning, i.e., pseudo label filtering with self-training. Overall, COSST achieves consistent superior segmentation performance than all compared methods on all three evaluated CT datasets, especially in the distance-based metrics HD95 and ASD.
2023BTI module proposedRuntimes155.5 sruntime-granularity=single-epochNexToU: Efficient Topology-Aware U-Net for Medical Image Segmentation
Source quote
L123: BTI │ 155.5
2023SPAD-ViT (fine-tuned from pre-trained weights; table label “Ours”) proposedDice77.84split: val · fine-tuned · training-data=20% (4 labeled samples) · training-steps=50KBuilding Universal Foundation Models for Medical Image Analysis with Spatially Adaptive Networks
Source quote
L427: 0.2 │ 70.98 │ 77.84 │ 6.85 │ 4.96 │ 2.39 │ 2.57 │ 51.13 │ 25.56 │ 25.57
2023SPAD-ViT (fine-tuned from pre-trained weights; table label “Ours”) proposedASSD2.39split: val · fine-tuned · training-data=20% (4 labeled samples) · training-steps=50KBuilding Universal Foundation Models for Medical Image Analysis with Spatially Adaptive Networks
Source quote
L427: 0.2 │ 70.98 │ 77.84 │ 6.85 │ 4.96 │ 2.39 │ 2.57 │ 51.13 │ 25.56 │ 25.57
2023SPAD-ViT (fine-tuned from pre-trained weights; table label “Ours”) proposedHD25.56split: val · fine-tuned · training-data=20% (4 labeled samples) · training-steps=50KBuilding Universal Foundation Models for Medical Image Analysis with Spatially Adaptive Networks
Source quote
L427: 0.2 │ 70.98 │ 77.84 │ 6.85 │ 4.96 │ 2.39 │ 2.57 │ 51.13 │ 25.56 │ 25.57
2023nnUnet with AFA-MI proposedDSC0.85split: test · backbone=nnU-Net · augmentation=AFA-MIDeep learning-based multi-organ CT segmentation with adversarial data augmentation
Source quote
L13: We firstly evaluate the AFA-MI augmentation using nnUnet and Token-based Transformer Vnet (TT-Vnet) on the test data from a public abdominal dataset and an institutional dataset. In addition, we validate how AFA-MI affects the networks’ robustness to the noisy data by evaluating the networks with added Gaussian noises of varying magnitudes to the institutional dataset. Network performance is quantitatively evaluated using Dice Similarity Coefficient (DSC) for volume-based accuracy. Also, Hausdorff Distance (HD) is applied for surface-based accuracy. On the public dataset, nnUnet with AFA-MI achieves DSC = 0.85 and HD = 6.16 millimeters (mm); and TT-Vnet achieves DSC = 0.86 and HD
2023TT-Vnet with AFA-MI proposedDSC0.86split: test · backbone=TT-VNet · augmentation=AFA-MIDeep learning-based multi-organ CT segmentation with adversarial data augmentation
Source quote
L13: We firstly evaluate the AFA-MI augmentation using nnUnet and Token-based Transformer Vnet (TT-Vnet) on the test data from a public abdominal dataset and an institutional dataset. In addition, we validate how AFA-MI affects the networks’ robustness to the noisy data by evaluating the networks with added Gaussian noises of varying magnitudes to the institutional dataset. Network performance is quantitatively evaluated using Dice Similarity Coefficient (DSC) for volume-based accuracy. Also, Hausdorff Distance (HD) is applied for surface-based accuracy. On the public dataset, nnUnet with AFA-MI achieves DSC = 0.85 and HD = 6.16 millimeters (mm); and TT-Vnet achieves DSC = 0.86 and HD
2023C-SliceGen proposedSSIM ↑0.603split: test · beta=0 · evaluation=3D volumetric · target-slice-selection=registrationDeep conditional generative models for longitudinal single-slice abdominal computed tomography harmonization
Source quote
L165: \beta = 0, Registration │ 0.603 │ 17.367 │ 0.362 │ 0.340
2023C-SliceGen proposedSSIM ↑0.605split: test · beta=0 · evaluation=3D volumetric · target-slice-selection=BPRDeep conditional generative models for longitudinal single-slice abdominal computed tomography harmonization
Source quote
L166: \beta = 0, BPR │ 0.605 │ 17.546 │ 0.376 │ 0.330
2023Ours (Model Adaptation + Model Ensemble), multi-organ student proposedDSC91.67%organ=liver-and-spleen · source-domains=LiTS-and-RSTailored multi-organ segmentation with model adaptation and ensemble
Source quote
L373: Ours │ {×} │ both │ 88.59 │ 2.03 │ 80.78 │ 1.74 │ 91.67 │ 2.14 │ 89.69 │ 1.46
2023RecycleNet proposedAverage DSC87.80split: test · inference-cycles=7RecycleNet: Latent Feature Recycling Leads to Iterative Decision Refinement
Source quote
L94: RecycleNet │ 90.26 │ 89.11 │ 83.75 │ 87.80 │ 94.92 │ 93.48 │ 91.85 │ 88.77 │ 90.82 │ 79.88
2023MedNeXt-L proposedDSC88.76split: val · ensemble=5-fold · kernel_size=5×5×5 · initialization=UpKernMedNeXt: Transformer-Driven Scaling of ConvNets for Medical Image Segmentation
Source quote
L190: \multirow{4}{*}{MedNeXt} │ BTCV │ 88.76
2023SSH-UNetaccuracy84.35%split: valSpatiotemporal Modeling Encounters 3D Medical Image Analysis: Slice-Shift UNet with Multi-View Fusion
Source quote
L184: In Table \ref{tab:per_organ_kfold} we can see the results of 5-fold cross-validation on the BTCV dataset. On average our model is able to reach 84.35% of accuracy without the help of any ensemble. From the table, we can observe that the fourth-fold segmentation of the spleen shows a significant drop in performance. The gallbladder and adrenal glands are segmented poorly by the first and second folds compared to the others. The first fold also led to a bad segmentation mask for the esophagus, liver, and stomach. We want to highlight that the official BTCV webpage emphasizes that some patients may not have the right kidney or gallbladder and thus are not labelled; however, our network is capable of segmenting the right kidney independently of the folds, while the drop in performance in the second fold in the gallbladder may be related to the lack of annotated data.
2023AutoProSAMmDice87.15Four-dataset multi-organ comparison; score is from the BTCV column. The table caption m…Auto-Prompting SAM for Mobile Friendly 3D Medical Image Segmentation
Source quote
L156: Ours │ 87.15 │ 78.83* │ 88.65* │ 79.41* │ 85.12 │ 76.37* │ 91.30* │ 84.35*
2023SwinUNETRmDice86.58Four-dataset multi-organ comparison; score is from the BTCV column.Auto-Prompting SAM for Mobile Friendly 3D Medical Image Segmentation
Source quote
L155: SwinUNETR~\cite{tang2022self} │ 86.58 │ 75.26 │ 86.19 │ 74.83 │ 84.34 │ 72.32 │ 89.12 │ 83.54
2023nnUNetTuned Params.31.18 Mresolution=128x128Auto-Prompting SAM for Mobile Friendly 3D Medical Image Segmentation
Source quote
L228: nnUNet~\cite{isensee2021nnu} │ 31.18 │ 3.74
2023Swin-UNETR baselineHD (Hausdorff Distance)20.53split: test · backbone=Swin-UNETRDisruptive Autoencoders: Leveraging Low-level features for 3D Medical Image Pre-training
Source quote
L137: Swin-UNETR │ 20.53 │ 0.810 │ 0.918
2023Swin-UNETR baselineMSD (Mean Surface Distance)0.810split: test · backbone=Swin-UNETRDisruptive Autoencoders: Leveraging Low-level features for 3D Medical Image Pre-training
Source quote
L137: Swin-UNETR │ 20.53 │ 0.810 │ 0.918
2023Swin-UNETR baselineDice0.918split: test · backbone=Swin-UNETRDisruptive Autoencoders: Leveraging Low-level features for 3D Medical Image Pre-training
Source quote
L137: Swin-UNETR │ 20.53 │ 0.810 │ 0.918
2023TFS (trained from scratch) baselineDice70.98split: val · training-data=20% (4 labeled samples) · training-steps=50KBuilding Universal Foundation Models for Medical Image Analysis with Spatially Adaptive Networks
Source quote
L427: 0.2 │ 70.98 │ 77.84 │ 6.85 │ 4.96 │ 2.39 │ 2.57 │ 51.13 │ 25.56 │ 25.57
2023TFS (trained from scratch) baselineASSD4.96split: val · training-data=20% (4 labeled samples) · training-steps=50KBuilding Universal Foundation Models for Medical Image Analysis with Spatially Adaptive Networks
Source quote
L427: 0.2 │ 70.98 │ 77.84 │ 6.85 │ 4.96 │ 2.39 │ 2.57 │ 51.13 │ 25.56 │ 25.57
2023TFS (trained from scratch) baselineHD51.13split: val · training-data=20% (4 labeled samples) · training-steps=50KBuilding Universal Foundation Models for Medical Image Analysis with Spatially Adaptive Networks
Source quote
L427: 0.2 │ 70.98 │ 77.84 │ 6.85 │ 4.96 │ 2.39 │ 2.57 │ 51.13 │ 25.56 │ 25.57
2023nnU-Net baselineAverage DSC87.21split: testRecycleNet: Latent Feature Recycling Leads to Iterative Decision Refinement
Source quote
L92: nnU-Net │ 89.29 │ 89.04 │ 82.96 │ 87.21 │ 94.77 │ 93.49 │ 91.47 │ 88.58 │ 90.68 │ 78,84
2022MixCL-pretrained UNETR encoder proposedDice coefficient0.3871split: val · fine-tuned · backbone=UNETR · labeled-data=15%MixCL: Pixel label matters to contrastive learning
Source quote
L122: 15% │ 0.8247 │ 0.8430 │ +0.0183 │ 15% │ 0.2459 │ 0.3871 │ +0.1412
2022APAUNet proposedAverage Dice87.84Reported average score in the BTCV comparison results.APAUNet: Axis Projection Attention UNet for Small Target in 3D Medical Segmentation
Source quote
L282: Our APAUNet achieves the best average dice score of 87.84 and the best average HD95 score of 11.26,
2022APAUNet proposedDice49.4target-size=0-0.1% of inputAPAUNet: Axis Projection Attention UNet for Small Target in 3D Medical Segmentation
Source quote
L304: Concretely, on the interval of 0 \sim 0.1%, our APAUNet achieves dice scores of 51.3, 55.1 and 49.4 on three datasets respectively,
2022mlTPSN proposedAverage Dice83.49scope=multi-object · template=bounding-box masksA Learning-based Framework for Topology-Preserving Segmentation using Quasiconformal Mappings
Source quote
L296: mlTPSN │ \B{83.49} │ 89.33 │ 89.10 │ \B{89.13} │ 82.11 │ 90.43 │ 87.07 │ \B{68.38} │ \B{72.40}
2022mlTPSN proposedAverage HD (Hausdorff distance)4.69scope=multi-object · template=bounding-box masksA Learning-based Framework for Topology-Preserving Segmentation using Quasiconformal Mappings
Source quote
L303: mlTPSN │ \B{4.69} │ \B{5.13} │ \B{3.33} │ \B{3.47} │ \B{3.27} │ 9.97 │ \B{6.12} │ \B{3.13} │ \B{3.06}
2022UNETR trained from scratch baselineDice coefficient0.2459split: val · fine-tuned · backbone=UNETR · labeled-data=15%MixCL: Pixel label matters to contrastive learning
Source quote
L122: 15% │ 0.8247 │ 0.8430 │ +0.0183 │ 15% │ 0.2459 │ 0.3871 │ +0.1412
2021Swin UNETR proposedDice (average over 13 organs)0.908organs=13Self-Supervised Pre-Training of Swin Transformers for 3D Medical Image Analysis
Source quote
L335: We extensively compare the benchmarks of our model with baselines. The published leaderboard evaluation is shown in Table~\ref{tab:tab2}. Compared with other top submissions, the proposed Swin UNETR achieves the best performance. We obtain the state-of-the-art Dice of 0.908, outperforming the second, third and fourth top-ranked baselines by 1.6%, 2.0% and 2.4% on average of 13 organs, respectively. Distinct improvements can be specifically observed for organs that are smaller in size, such as splenic and portal veins of 3.6% against prior state-of-the-art method, pancreas of 1.6%, and adrenal glands of 3.8%. Moderate improvements are observed in other organs. The representative samples in Fig.~\ref{fig:fig4} demonstrate the success of identifying organ details by Swin UNETR. Our method detects the pancreas tail (row 1), and branches in the portal vein (row 2) in Fig.~\ref{fig:fig4}, where other methods under segment parts of each tissue. In addition, our method demonstrates distinct improvement in segmentation of adrenal glands (row 3).
2021MI+Labelcrop proxy data proposed non-standard slicecorrelation0.37split: external-validation · organ=spleen · subset=24% of full datasetThe Power of Proxy Data and Proxy Networks for Hyper-parameter Optimization in Medical Image Segmentation
Source quote
L110: Observing across the entire hyper-parameter space the proxy data selection method MI+Labelcrop shows a higher correlation of 0.37 versus 0.32 as compared to random selection of data on the external validation when being compared with the ground truth which is obtained by training with all the data (shown in Fig.~\ref{fig2:proxy_data_spleen}).
2021UNETR proposedoverall average Dice score0.899split: test · ensemble=four five-fold cross-validations · competition=Free Competition · training-cases=80UNETR: Transformers for 3D Medical Image Segmentation
Source quote
L387: UNETR outperforms the state-of-the-art methods for both Standard and Free Competitions on the BTCV leaderboard. As shown in Table~\ref{tab:BTCV}, in the Free Competition, UNETR achieves an overall average Dice score of 0.899 and outperforms the second, third and fourth top-ranked methodologies by 1.238%, 1.696% and 5.269% respectively.
2021UNETR proposedaverage Dice score across all organs85.3%split: test · ensemble=four five-fold cross-validations · competition=Standard CompetitionUNETR: Transformers for 3D Medical Image Segmentation
Source quote
L389: In the Standard Competition, we compared the performance of UNETR against CNN and transformer-based baselines. UNETR achieves a new state-of-the-art performance with an average Dice score of 85.3% on all organs. Specifically, on large organs, such as spleen, liver and stomach, our method outperforms the second best baselines by 1.043%, 0.830% and 2.125% respectively,in terms of Dice score. Furthermore, in segmentation of small organs, our method significantly outperforms the second best baselines by 6.382% and 6.772% on gallbladder and adrenal glands respectively, in terms of Dice score.
2021Random data selection baseline non-standard slicecorrelation0.32split: external-validation · organ=spleen · subset=24% of full datasetThe Power of Proxy Data and Proxy Networks for Hyper-parameter Optimization in Medical Image Segmentation
Source quote
L110: Observing across the entire hyper-parameter space the proxy data selection method MI+Labelcrop shows a higher correlation of 0.37 versus 0.32 as compared to random selection of data on the external validation when being compared with the ground truth which is obtained by training with all the data (shown in Fig.~\ref{fig2:proxy_data_spleen}).
2021Aug. + U-Net-1 baselineDice Similarity Coefficient30.84%1-shot · setting=one-shotA Unified Framework for Generalized Low-Shot Medical Image Segmentation with Scarce Data
Source quote
L660: Aug. + U-Net-1~\cite{luna20183d} │ 31.48 (3.75) │ 44.84 (4.11) │ 34.03 (4.62) │ 26.38 (2.98) │ 17.24 (2.80) │ 61.68 (1.41) │ 11.56 (0.59) │ 19.48 (0.82) │ *30.84 (5.22)
2021ANTs-1 baselineDice Similarity Coefficient34.98%1-shot · setting=one-shotA Unified Framework for Generalized Low-Shot Medical Image Segmentation with Scarce Data
Source quote
L659: ANTs-1~\cite{avants2011reproducible} │ 51.62 (2.97) │ 33.60 (4.63) │ 17.65 (5.57) │ 15.25 (4.25) │ 56.30 (3.71) │ 76.48 (1.55) │ 24.60 (1.61) │ 4.31 (0.64) │ *34.98 (3.73)