BTCV

60 papers · 128 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

79.780.581.382.02025VOILA (V-L Interaction + Random sampling): 79.9 (2025)VOILA (Ts-v2-trained, without fine-tuning): 81.4 (2025)VOILA (V-L Interaction + CAS): 81.4 (2025)SegVol (text+bbox): 81.87 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 32 of 32 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026EvoML proposedDice0.837split: test · supervisedValidation-Gated ML Pipeline Synthesis with Expert-Grounded Self-Evolving Skills
Source quote
L1413: 0.837
2025VOILA (Ts-v2-trained, without fine-tuning) proposedDice81.4split: test · 0-shot · fine-tuning=none · training-dataset=Ts-v2VOILA: Complexity-Aware Universal Segmentation of CT Images by Voxel Interacting with Language
Source quote
L147: 81.4(+7.3)
2025VOILA (dataset-specific supervised) proposedDice74.1split: test · supervised · training-dataset=BTCVVOILA: Complexity-Aware Universal Segmentation of CT Images by Voxel Interacting with Language
Source quote
L150: 74.1
2025VOILA (Ts-v2-trained, without fine-tuning) proposedNSD80.9split: test · 0-shot · fine-tuning=none · training-dataset=Ts-v2VOILA: Complexity-Aware Universal Segmentation of CT Images by Voxel Interacting with Language
Source quote
L148: 80.9(+9)
2025VOILA (Ts-v2-trained, without fine-tuning) proposedHD9516.0split: test · 0-shot · fine-tuning=none · training-dataset=Ts-v2VOILA: Complexity-Aware Universal Segmentation of CT Images by Voxel Interacting with Language
Source quote
L149: 16.0(-22.2)
2025SSFMamba proposedAvg Dice82.43split: test · score=average across listed organs · modality=CTSSFMamba: Symmetry-driven Spatial-Frequency Feature Fusion for 3D Medical Image Segmentation
Source quote
L402: 95.44 │ 94.34 │ 94.07 │ 62.53 │ 76.12 │ 96.67 │ 83.93 │ 89.94 │ 86.27 │ 74.19 │ 81.97 │ 69.30 │ 68.83 │ 82.43
2025SSFMamba proposedPancreas Dice81.97%split: test · modality=CT · structure=pancreasSSFMamba: Symmetry-driven Spatial-Frequency Feature Fusion for 3D Medical Image Segmentation
Source quote
L415: Empirical Validation of Modality Independence. The consistent superiority of SSFMamba across MRI (BraTS) and CT (BTCV) benchmarks provides empirical evidence for the modality-invariant hypothesis proposed in Section I. Crucially, SSFMamba maintains its leading performance across these heterogeneous datasets without the need for tedious modality-specific hyper-parameter tuning or architecture modifications, embodying a truly 'modality-agnostic' perception paradigm. Traditional spatial features are notoriously sensitive to domain shifts arising from varied scanner protocols or organ contrasts. In contrast, our results demonstrate that the spectral domain offers a more stable representational manifold; specifically, low-frequency components representing global organ envelopes remain physically consistent across modalities. This stability is most prominent in the segmentation of low-contrast organs like the pancreas, where SSFMamba achieves a substantial performance gain (81.97% Dice). This success demonstrates the capacity to isolate distinctive spectral signatures of tissue interfaces that are typically suppressed or blurred in the spatial domain due to limited intensity resolution. By acting as an Adaptive Spectral Gate, the frequency branch prioritizes subtle mid-to-high frequency components to enhance the signal-to-noise ratio (SNR) for structural features buried in the modality-specific noise floor. This validates that spectral selectivity is a potent tool for capturing heterogeneous anatomical details across diverse clinical scenarios.
2025MedROV proposedmAP5079.1split: test · 0-shot · modality=CTMedROV: Towards Real-Time Open-Vocabulary Detection Across Diverse Medical Imaging Modalities
Source quote
L159: BTCV │ CT │ 9.09 │ 79.1 │ 70.01
2025AutoProSAM (P&M) proposedmDice87.15split: test · fine-tuned · classes=13 · modality=CT · dimension=3DAutoProSAM: Automated Prompting SAM for 3D Multi-Organ Segmentation
Source quote
L282: 87.15
2025MedDelinea proposedmDSC77.52%split: test · few-shot · subset=1% of training data · pretraining=ATLAS-8kMedDelinea: Scalable and Efficient Medical Image Segmentation via Controllable Diffusion Transformers
Source quote
L350: 77.52
2025EM-Net 2024 baselineAvg Dice81.55split: test · score=average across listed organs · modality=CTSSFMamba: Symmetry-driven Spatial-Frequency Feature Fusion for 3D Medical Image Segmentation
Source quote
L395: 92.43 │ 91.57 │ 90.34 │ 67.65 │ 75.13 │ 95.84 │ 83.98 │ 90.66 │ 86.47 │ 73.03 │ 74.98 │ 70.10 │ 68.09 │ 81.55
2025UNETR++ baselinemean DSC83.28split: test · subjects=20Advancing Medical Image Segmentation via Self-supervised Instance-adaptive Prototype Learning
Source quote
L162: UNETR++ │ 94.94 │ 91.90 │ 93.62 │ 70.75 │ 77.18 │ 95.95 │ 85.15 │ 89.28 │ 83.14 │ 76.91 │ 77.42 │ 72.56 │ 68.17 │ 83.28
2025BioMedParse baselinemAP509.09split: test · 0-shot · modality=CTMedROV: Towards Real-Time Open-Vocabulary Detection Across Diverse Medical Imaging Modalities
Source quote
L159: BTCV │ CT │ 9.09 │ 79.1 │ 70.01
2025MedSAM (Full) baselinemDice84.57split: test · fine-tuned · classes=13 · modality=CT · dimension=3DAutoProSAM: Automated Prompting SAM for 3D Multi-Organ Segmentation
Source quote
L276: 84.57
2024MOSMOS + U-Net (ResNet-50) proposedAvg. Dice80.10%split: test · fine-tuned · backbone=ResNet-50 · architecture=U-NetMOSMOS: Multi-organ segmentation facilitated by medical report supervision
Source quote
L267: MOSMOS~(Ours) │ 94.36 │ 93.56 │ 93.81 │ 73.01 │ 72.24 │ 96.11 │ 81.85 │ 89.04 │ 83.72 │ 60.74 │ 76.16 │ 64.95 │ \multicolumn{1}{l|}{61.68} │ 80.10
2024nnUNet + Pool Skip proposedDICE82.47%split: test · five-fold-cross-validation · model=nnUNet · variant=Pool Skip · test-scans=12Beyond Skip Connection: Pooling and Unpooling Design for Elimination Singularities
Source quote
L285: \ \ \ \ +ours │ 82.47 \textcolor[rgb]{ 1, 0, 0}{+0.95} │ 77.00 \textcolor[rgb]{ 1, 0, 0}{+0.90} │ 73.08 \textcolor[rgb]{ 1, 0, 0}{+0.94}
2024ImageNet + U-Net (ResNet-50) baselineAvg. Dice76.73%split: test · fine-tuned · backbone=ResNet-50 · architecture=U-NetMOSMOS: Multi-organ segmentation facilitated by medical report supervision
Source quote
L260: ImageNet~\cite{deng2009imagenet} │ 92.87 │ 91.16 │ 91.87 │ 60.00 │ 69.83 │ 96.19 │ 71.08 │ 89.80 │ 81.84 │ 67.59 │ 73.99 │ 58.03 │ \multicolumn{1}{l|}{53.20} │ 76.73
2024nnUNet (no Pool Skip) baselineDICE81.52%split: test · five-fold-cross-validation · model=nnUNet · variant=no Pool Skip · test-scans=12Beyond Skip Connection: Pooling and Unpooling Design for Elimination Singularities
Source quote
L284: } │ 81.52 │ 76.10 │ 72.14
2023DAE proposedHD (Hausdorff Distance)16.82split: test · ensemble=four rounds of five-fold cross-validation · resolution=1×1×1 mmDisruptive Autoencoders: Leveraging Low-level features for 3D Medical Image Pre-training
Source quote
L138: DAE (Ours) │ 16.82 │ 0.654 │ 0.921
2023DAE proposedMSD (Mean Surface Distance)0.654split: test · ensemble=four rounds of five-fold cross-validation · resolution=1×1×1 mmDisruptive Autoencoders: Leveraging Low-level features for 3D Medical Image Pre-training
Source quote
L138: DAE (Ours) │ 16.82 │ 0.654 │ 0.921
2023DAE proposedDice0.921split: test · ensemble=four rounds of five-fold cross-validation · resolution=1×1×1 mmDisruptive Autoencoders: Leveraging Low-level features for 3D Medical Image Pre-training
Source quote
L138: DAE (Ours) │ 16.82 │ 0.654 │ 0.921
2023nnUnet with AFA-MI proposedDSC0.85split: test · backbone=nnU-Net · augmentation=AFA-MIDeep learning-based multi-organ CT segmentation with adversarial data augmentation
Source quote
L13: We firstly evaluate the AFA-MI augmentation using nnUnet and Token-based Transformer Vnet (TT-Vnet) on the test data from a public abdominal dataset and an institutional dataset. In addition, we validate how AFA-MI affects the networks’ robustness to the noisy data by evaluating the networks with added Gaussian noises of varying magnitudes to the institutional dataset. Network performance is quantitatively evaluated using Dice Similarity Coefficient (DSC) for volume-based accuracy. Also, Hausdorff Distance (HD) is applied for surface-based accuracy. On the public dataset, nnUnet with AFA-MI achieves DSC = 0.85 and HD = 6.16 millimeters (mm); and TT-Vnet achieves DSC = 0.86 and HD
2023TT-Vnet with AFA-MI proposedDSC0.86split: test · backbone=TT-VNet · augmentation=AFA-MIDeep learning-based multi-organ CT segmentation with adversarial data augmentation
Source quote
L13: We firstly evaluate the AFA-MI augmentation using nnUnet and Token-based Transformer Vnet (TT-Vnet) on the test data from a public abdominal dataset and an institutional dataset. In addition, we validate how AFA-MI affects the networks’ robustness to the noisy data by evaluating the networks with added Gaussian noises of varying magnitudes to the institutional dataset. Network performance is quantitatively evaluated using Dice Similarity Coefficient (DSC) for volume-based accuracy. Also, Hausdorff Distance (HD) is applied for surface-based accuracy. On the public dataset, nnUnet with AFA-MI achieves DSC = 0.85 and HD = 6.16 millimeters (mm); and TT-Vnet achieves DSC = 0.86 and HD
2023C-SliceGen proposedSSIM ↑0.603split: test · beta=0 · evaluation=3D volumetric · target-slice-selection=registrationDeep conditional generative models for longitudinal single-slice abdominal computed tomography harmonization
Source quote
L165: \beta = 0, Registration │ 0.603 │ 17.367 │ 0.362 │ 0.340
2023C-SliceGen proposedSSIM ↑0.605split: test · beta=0 · evaluation=3D volumetric · target-slice-selection=BPRDeep conditional generative models for longitudinal single-slice abdominal computed tomography harmonization
Source quote
L166: \beta = 0, BPR │ 0.605 │ 17.546 │ 0.376 │ 0.330
2023RecycleNet proposedAverage DSC87.80split: test · inference-cycles=7RecycleNet: Latent Feature Recycling Leads to Iterative Decision Refinement
Source quote
L94: RecycleNet │ 90.26 │ 89.11 │ 83.75 │ 87.80 │ 94.92 │ 93.48 │ 91.85 │ 88.77 │ 90.82 │ 79.88
2023Swin-UNETR baselineHD (Hausdorff Distance)20.53split: test · backbone=Swin-UNETRDisruptive Autoencoders: Leveraging Low-level features for 3D Medical Image Pre-training
Source quote
L137: Swin-UNETR │ 20.53 │ 0.810 │ 0.918
2023Swin-UNETR baselineMSD (Mean Surface Distance)0.810split: test · backbone=Swin-UNETRDisruptive Autoencoders: Leveraging Low-level features for 3D Medical Image Pre-training
Source quote
L137: Swin-UNETR │ 20.53 │ 0.810 │ 0.918
2023Swin-UNETR baselineDice0.918split: test · backbone=Swin-UNETRDisruptive Autoencoders: Leveraging Low-level features for 3D Medical Image Pre-training
Source quote
L137: Swin-UNETR │ 20.53 │ 0.810 │ 0.918
2023nnU-Net baselineAverage DSC87.21split: testRecycleNet: Latent Feature Recycling Leads to Iterative Decision Refinement
Source quote
L92: nnU-Net │ 89.29 │ 89.04 │ 82.96 │ 87.21 │ 94.77 │ 93.49 │ 91.47 │ 88.58 │ 90.68 │ 78,84
2021UNETR proposedoverall average Dice score0.899split: test · ensemble=four five-fold cross-validations · competition=Free Competition · training-cases=80UNETR: Transformers for 3D Medical Image Segmentation
Source quote
L387: UNETR outperforms the state-of-the-art methods for both Standard and Free Competitions on the BTCV leaderboard. As shown in Table~\ref{tab:BTCV}, in the Free Competition, UNETR achieves an overall average Dice score of 0.899 and outperforms the second, third and fourth top-ranked methodologies by 1.238%, 1.696% and 5.269% respectively.
2021UNETR proposedaverage Dice score across all organs85.3%split: test · ensemble=four five-fold cross-validations · competition=Standard CompetitionUNETR: Transformers for 3D Medical Image Segmentation
Source quote
L389: In the Standard Competition, we compared the performance of UNETR against CNN and transformer-based baselines. UNETR achieves a new state-of-the-art performance with an average Dice score of 85.3% on all organs. Specifically, on large organs, such as spleen, liver and stomach, our method outperforms the second best baselines by 1.043%, 0.830% and 2.125% respectively,in terms of Dice score. Furthermore, in segmentation of small organs, our method significantly outperforms the second best baselines by 6.382% and 6.772% on gallbladder and adrenal glands respectively, in terms of Dice score.