BTCV
60 papers · 128 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | SegVol (text+bbox) SOTA frontier | 81.87 | 2025-03-01 | prompt=text+bbox · Known-anatomy abdominal CT; text combined with a bounding-box prompt, compared with S… | Zero-shot Domain Generalization of Foundational Models for 3D Medical Image Segmentation: An Experimental StudySource quote\keypoint{Text inputs boost spatial prompts.} We investigate the effect of semantic prompts as an additional guidance alongside spatial prompts for SegVol~\cite{segvol}, denoted by ``text+bbox'' and ``text+points'' in \autoref{tab:sec4p3}. Comparing them with corresponding vanilla spatial prompts in \autoref{tab:sec4p2}, we notice that for known anatomies (abdominal CT and MR), the addition of text consistently improves segmentations from raw spatial prompts (BTCV: 80.15 w/ bbox, 81.87 w/ text+bbox; CHAOS: 80.25 w/ points, 81.06 w/ text+points). We show example segmentation results in \autoref{fig:bbox_text}. For unseen anatomies, text prompts completely fail, since the model has no knowledge to spatially ground such concepts. |
| 2 | VOILA (Ts-v2-trained, without fine-tuning) SOTA frontier | 81.4 | 2025-01-01 | fine-tuning=none · training-dataset=Ts-v2 · Trained on Ts-v2 with contrastive loss and evaluated on the BTCV test set without fin… | VOILA: Complexity-Aware Universal Segmentation of CT Images by Voxel Interacting with LanguageSource quote81.4(+7.3) |
| 3 | VOILA (V-L Interaction + CAS) SOTA frontier (+1 variant) | 81.4 | 2025-01-01 | sampling-ratio=0.1 · training-dataset=Ts-v2 · Sampling ratio 0.1; trained on Ts-v2 and inferred on BTCV without fine-tuning. | VOILA: Complexity-Aware Universal Segmentation of CT images by Voxel Interacting with LanguageSource quote\ding{52} │ CAS │ 0.1 │ 92.1 │ 11.2 │ 81.4 │ 80.9 │ 16.0 │ 81.2 │ 71.7 │ 20.6 |
Regimefine-tuned (21)0-shot (13)post-training-quantization (3)class-incremental (2)supervised (2)five-fold-cross-validation (2)
Showing 74 of 74 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Ours (Janus1B) proposed | Mean Dice | 82.31 | split: val · backbone=Janus1B · validation=5-fold cross-validation | Segmentation, Detection and Explanation: A Unified Framework for CT Appearance ReasoningSource quoteL387: 86.59 │ 82.96 │ 73.74 │ 80.44 │ 65.78 │ 82.31 |
| 2026 | EvoML proposed | Dice | 0.837 | split: test · supervised | Validation-Gated ML Pipeline Synthesis with Expert-Grounded Self-Evolving SkillsSource quoteL1413: 0.837 |
| 2026 | RadSight-4B proposed | mIoU | 47.54 | 0-shot · params=4B · model-size=4B | RadSight: Towards Perceptually Reliable Multimodal Radiology Image UnderstandingSource quoteL1213: RadSight-4B │ 47.54 │ 80.67 │ 44.57 │ 75.62 |
| 2026 | RadSight-4B proposed | F1 | 80.67 | 0-shot · params=4B · model-size=4B · IoU-threshold=0.3 | RadSight: Towards Perceptually Reliable Multimodal Radiology Image UnderstandingSource quoteL1213: RadSight-4B │ 47.54 │ 80.67 │ 44.57 │ 75.62 |
| 2026 | HSMLA-B2 proposed | Dice | 87.3% | resolution=512×512 · model-variant=HSMLA-B2 · dimensionality=2D | HSMLA: Hierarchical Softmax Multi-scale Linear Attention for Efficient Vision TransformersSource quoteL364: HSMLA demonstrates strong performance across all four benchmarks. On BTCV multi-organ CT segmentation, HSMLA-B2 achieves 87.3% Dice and HD95 of 8.6\,mm with 3.2× speedup, outperforming medical-specialist baselines TransUNet (77.5% Dice, 31.7\,mm HD95) and SwinUNet (79.1% Dice, 21.6\,mm HD95). The 21% reduction in HD95 vs.\ BiFormer-B2 (10.9\,mm \rightarrow 8.6\,mm) directly demonstrates that sparse softmax refinement improves organ boundary delineation. On CAMELYON16 gigapixel WSI, HSMLA-B2 reaches 94.2% AUC with 4.1× acceleration by directing softmax attention toward tumor patches. EndoVis 2017 confirms real-time surgical applicability: HSMLA-B0 achieves 89.7% Dice at 42\,FPS with reduced memory (3.7\,GB \rightarrow 2.1\,GB) on Jetson AGX Orin. On LUNA16, HSMLA-B2 attains 95.0% sensitivity at 4\,FP/scan (+3.8% vs.\ SegFormer) with 2.9× speedup, indicating that HSMLA effectively concentrates computation on small nodule regions while preserving global anatomical context. Overall, these results confirm that HSMLA’s query-sparse softmax refinement is particularly effective in medical imaging, where it concentrates computation on small, diagnostically relevant structures (organ boundaries, tumor regions, nodules) under strict latency and memory constraints. |
| 2025 | CoSimGen proposed | KID | 0.13 | Generated-image fidelity against real images; models sampled at optimal convergence; sp… | CoSimGen: Controllable Diffusion Model for Simultaneous Image and Mask GenerationSource quoteL212: CoSimGen (Ours) │ 206.29 │ 0.20 │ 227.64 │ 0.74 │ 203.67 │ 0.11 │ 110.43 │ 0.63 │ 159.92 │ 0.13 │ 139.35 │ 0.53 |
| 2025 | CoSimGen proposed | LPIPS-D | 0.53 | Generated-image fidelity against real images; models sampled at optimal convergence; sp… | CoSimGen: Controllable Diffusion Model for Simultaneous Image and Mask GenerationSource quoteL212: CoSimGen (Ours) │ 206.29 │ 0.20 │ 227.64 │ 0.74 │ 203.67 │ 0.11 │ 110.43 │ 0.63 │ 159.92 │ 0.13 │ 139.35 │ 0.53 |
| 2025 | PGCD + DAPD (full proposed method) proposed | DSC | 90.60% | class-incremental · steps=2 · class-incremental-setting=4-4 | Class Incremental Medical Image Segmentation via Prototype-Guided Calibration and Dual-Aligned DistillationSource quoteL357: Ours │ 62.19 │ 2.45 │ 329.84 │ 39 │ 1.93 │ 15.46 │ 90.60 |
| 2025 | VOILA (Ts-v2-trained, without fine-tuning) proposed | Dice | 81.4 | split: test · 0-shot · fine-tuning=none · training-dataset=Ts-v2 | VOILA: Complexity-Aware Universal Segmentation of CT Images by Voxel Interacting with LanguageSource quoteL147: 81.4(+7.3) |
| 2025 | VOILA (dataset-specific supervised) proposed | Dice | 74.1 | split: test · supervised · training-dataset=BTCV | VOILA: Complexity-Aware Universal Segmentation of CT Images by Voxel Interacting with LanguageSource quoteL150: 74.1 |
| 2025 | VOILA (Ts-v2-trained, without fine-tuning) proposed | NSD | 80.9 | split: test · 0-shot · fine-tuning=none · training-dataset=Ts-v2 | VOILA: Complexity-Aware Universal Segmentation of CT Images by Voxel Interacting with LanguageSource quoteL148: 80.9(+9) |
| 2025 | VOILA (Ts-v2-trained, without fine-tuning) proposed | HD95 | 16.0 | split: test · 0-shot · fine-tuning=none · training-dataset=Ts-v2 | VOILA: Complexity-Aware Universal Segmentation of CT Images by Voxel Interacting with LanguageSource quoteL149: 16.0(-22.2) |
| 2025 | SSFMamba proposed | Avg Dice | 82.43 | split: test · score=average across listed organs · modality=CT | SSFMamba: Symmetry-driven Spatial-Frequency Feature Fusion for 3D Medical Image SegmentationSource quoteL402: 95.44 │ 94.34 │ 94.07 │ 62.53 │ 76.12 │ 96.67 │ 83.93 │ 89.94 │ 86.27 │ 74.19 │ 81.97 │ 69.30 │ 68.83 │ 82.43 |
| 2025 | SSFMamba proposed | Pancreas Dice | 81.97% | split: test · modality=CT · structure=pancreas | SSFMamba: Symmetry-driven Spatial-Frequency Feature Fusion for 3D Medical Image SegmentationSource quoteL415: Empirical Validation of Modality Independence. The consistent superiority of SSFMamba across MRI (BraTS) and CT (BTCV) benchmarks provides empirical evidence for the modality-invariant hypothesis proposed in Section I. Crucially, SSFMamba maintains its leading performance across these heterogeneous datasets without the need for tedious modality-specific hyper-parameter tuning or architecture modifications, embodying a truly 'modality-agnostic' perception paradigm. Traditional spatial features are notoriously sensitive to domain shifts arising from varied scanner protocols or organ contrasts. In contrast, our results demonstrate that the spectral domain offers a more stable representational manifold; specifically, low-frequency components representing global organ envelopes remain physically consistent across modalities. This stability is most prominent in the segmentation of low-contrast organs like the pancreas, where SSFMamba achieves a substantial performance gain (81.97% Dice). This success demonstrates the capacity to isolate distinctive spectral signatures of tissue interfaces that are typically suppressed or blurred in the spatial domain due to limited intensity resolution. By acting as an Adaptive Spectral Gate, the frequency branch prioritizes subtle mid-to-high frequency components to enhance the signal-to-noise ratio (SNR) for structural features buried in the modality-specific noise floor. This validates that spectral selectivity is a potent tool for capturing heterogeneous anatomical details across diverse clinical scenarios. |
| 2025 | MambaMIM-pretrained HyMamba proposed | DSC (Avg) | 80.16% | split: val · fine-tuned · backbone=HyMamba · evaluation=five-fold-cross-validation · pretraining=MambaMIM | MambaMIM: Pre-training Mamba with state space token interpolation and its application to medical image segmentationSource quoteL522: 80.16 |
| 2025 | MedROV proposed | mAP50 | 79.1 | split: test · 0-shot · modality=CT | MedROV: Towards Real-Time Open-Vocabulary Detection Across Diverse Medical Imaging ModalitiesSource quoteL159: BTCV │ CT │ 9.09 │ 79.1 │ 70.01 |
| 2025 | DDPM_BPR-FPN (anatomically guided diffusion pretraining) proposed | Average Dice coefficient | 67.8 | linear-probe · probe=non-linear · representation=frozen | Medical Semantic Segmentation with Diffusion PretrainSource quoteL77: \text{DDPM}_{\text{BPR}}-FPN │ 82.3 │ 85.7 │ 34.1 │ 62.0 │ 89.1 │ 60.0 │ 86.1 │ 74.0 │ 48.5 │ 53.9 │ 49.1 │ 67.8 |
| 2025 | AutoProSAM (P&M) proposed | mDice | 87.15 | split: test · fine-tuned · classes=13 · modality=CT · dimension=3D | AutoProSAM: Automated Prompting SAM for 3D Multi-Organ SegmentationSource quoteL282: 87.15 |
| 2025 | MedDINOv3 proposed | DSC | 78.79% | split: val · evaluation=one-fold-of-5-fold-cross-validation | MedDINOv3: How to adapt vision foundation models for medical image segmentation?Source quoteL145: MedDINOv3 (ours) │ 87.38 │ 70.68 │ 75.28 │ 78.79 │ 77.15 │ 62.67 │ 53.01 │ 70.38 |
| 2025 | SHF-SAM2 proposed | Dice Score | 89.71% | hardware=single GPU · patch-size=2³ · processing=3D voxel | SHF: Symmetrical Hierarchical Forest with Pretrained Vision Transformer Encoder for High-Resolution Medical SegmentationSource quoteL522: 89.71 |
| 2025 | MLRU++ proposed | Mean DSC | 85.20% | Average across all organs. | MLRU++: Multiscale Lightweight Residual UNETR++ with Attention for Efficient 3D Medical Image SegmentationSource quoteL223: MLRU++ (Ours) │ 96.44 │ 94.96 │ 94.93 │ 65.45 │ {75.47} │ 97.16 │ 90.00 │ {90.38} │ 88.34 │ 79.71 │ 87.31 │ {73.10} │ 74.29 │ 85.20 |
| 2025 | MedNeXt-v2 proposed | Dice Similarity Coefficient (DSC) | 80.99 | split: val | MedNeXt-v2: Scaling 3D ConvNeXts for Large-Scale Supervised Representation Learning in Medical Image SegmentationSource quoteL65: MedNeXt-v2 │ 80.99 │ 88.05 │ 89.09 │ 93.39 │ 88.03 |
| 2025 | MedDelinea proposed | mDSC | 87.01% | fine-tuned · pretraining=ATLAS-8k | MedDelinea: Scalable and Efficient Medical Image Segmentation via Controllable Diffusion TransformersSource quoteL388: MedDelinea’s performance in fine-tuning and zero-shot learning scenarios. After fine-tuning on each dataset post ATLAS-8k pre-training, MedDelinea achieves the highest metrics, including an mDSC of 87.01% on BTCV and 82.19% on AMOS. In zero-shot learning, MedDelinea demonstrates robust generalization capabilities, leading with an mDSC of 80.01% on BTCV and 78.67% on AMOS. This suggests that MedDelinea’s architecture is adaptable and effective in transferring learned features from pre-training to new datasets. |
| 2025 | MedDelinea proposed | mDSC | 80.01% | 0-shot · pretraining=ATLAS-8k | MedDelinea: Scalable and Efficient Medical Image Segmentation via Controllable Diffusion TransformersSource quoteL388: MedDelinea’s performance in fine-tuning and zero-shot learning scenarios. After fine-tuning on each dataset post ATLAS-8k pre-training, MedDelinea achieves the highest metrics, including an mDSC of 87.01% on BTCV and 82.19% on AMOS. In zero-shot learning, MedDelinea demonstrates robust generalization capabilities, leading with an mDSC of 80.01% on BTCV and 78.67% on AMOS. This suggests that MedDelinea’s architecture is adaptable and effective in transferring learned features from pre-training to new datasets. |
| 2025 | MedDelinea proposed | mDSC | 77.52% | split: test · few-shot · subset=1% of training data · pretraining=ATLAS-8k | MedDelinea: Scalable and Efficient Medical Image Segmentation via Controllable Diffusion TransformersSource quoteL350: 77.52 |
| 2025 | Models trained on filtered UKBOB proposed | Mean Dice Score | 0.837 | 0-shot · training-data=filtered UKBOB | UKBOB: One Billion MRI Labeled Masks for Generalizable 3D Medical Image SegmentationSource quoteL461: BTCV │ 0.837 │ 5.138 |
| 2025 | LGMSNet proposed | Dice (Avg) | 84.10 | 3D abdominal segmentation; average across the organ categories listed in the BTCV table… | LGMSNet: Thinning a medical image segmentation model via dual-level multiscale fusionSource quoteL201: 84.10 |
| 2025 | LGMSNet proposed | Dice (Gall) | 79.37 | 3D abdominal segmentation; Gall is the gallbladder category in the BTCV results. The 3D… | LGMSNet: Thinning a medical image segmentation model via dual-level multiscale fusionSource quoteL200: LGMSNet │ Ours │ 9.86 │ 95.82 │ 94.84 │ 94.70 │ 79.37 │ 73.38 │ 96.99 │ 85.80 │ 90.44 │ 86.69 │ 76.15 │ 83.06 |
| 2025 | LGMSNet proposed | Param | 9.86 | Parameter value reported for LGMSNet alongside its BTCV 3D segmentation results; the pa… | LGMSNet: Thinning a medical image segmentation model via dual-level multiscale fusionSource quoteL200: LGMSNet │ Ours │ 9.86 │ 95.82 │ 94.84 │ 94.70 │ 79.37 │ 73.38 │ 96.99 │ 85.80 │ 90.44 │ 86.69 │ 76.15 │ 83.06 |
| 2025 | SimCroP proposed | Dice | 80.7 | fine-tuned · subset=100% · backbone=3D ViT-B | SimCroP: Radiograph Representation Learning with Similarity-Driven Cross-Granularity Pre-trainingSource quoteL122: SimCroP\xspace (Ours) │ 93.5 │ 93.7 │ 80.7 |
| 2025 | Mobile U-ViT-L (3D) proposed | Dice | 78.42% | split: val · 5-fold-cross-validation · backbone=ViT-L · dimensionality=3D | Mobile U-ViT: Revisiting large kernel and U-shaped ViT for efficient medical image segmentationSource quoteL693: Mobile U-ViT-L (3D) │ 11.06 │ 110.88 │ 28.24 │ {78.42} │ {6.56} │ {2.18} │ {89.59} │ {85.81} │ {69.35} │ {72.20} │ {94.16} │ {83.34} │ {89.40} │ {82.60} │ {68.85} │ {73.31} │ {62.49} |
| 2025 | 3D SEEDS proposed | Achievable Dice score | 86.67% | organ=spleen · subset=organs sufficiently large under current supervoxel setting · supervoxels=4096 · configuration=default | Extending SEEDS to a Supervoxel Algorithm for Medical Image AnalysisSource quoteL280: 3D SEEDS │ 86.67 │ 79.75 │ 79.89 │ 43.10 │ 90.68 │ 79.06 │ 62.49 │ 50.72 │ 47.06 |
| 2025 | VOILA (V-L Interaction + CAS) proposed | Dice | 81.4 | 0-shot · sampling-ratio=0.1 · training-dataset=Ts-v2 | VOILA: Complexity-Aware Universal Segmentation of CT images by Voxel Interacting with LanguageSource quoteL122: \ding{52} │ CAS │ 0.1 │ 92.1 │ 11.2 │ 81.4 │ 80.9 │ 16.0 │ 81.2 │ 71.7 │ 20.6 |
| 2025 | U-Net INT8 TensorRT (proposed PTQ) proposed | Model size | 6.61 MB | post-training-quantization · GPU=NVIDIA RTX 4090 · cases=20 · model=U-Net · engine=TensorRT · precision=INT8 | Post-Training Quantization for 3D Medical Image Segmentation: A Practical Study on Real Inference EnginesSource quoteL11: (b) TensorRT Engine with INT8 Precision. We propose a real PTQ framework using NVIDIA TensorRT to convert FP32 models into INT8, enabling notable reductions in both model size and inference latency without compromising performance. For example, U-Net's model size shrinks from 23.11 MB to 6.61 MB, and its inference latency drops from 2.62 ms to 1.05 ms, while maintaining the same mean Dice Score (mDSC) of 0.822. |
| 2025 | U-Net INT8 TensorRT (proposed PTQ) proposed | Inference latency | 1.05 ms | post-training-quantization · GPU=NVIDIA RTX 4090 · cases=20 · model=U-Net · engine=TensorRT · precision=INT8 | Post-Training Quantization for 3D Medical Image Segmentation: A Practical Study on Real Inference EnginesSource quoteL11: (b) TensorRT Engine with INT8 Precision. We propose a real PTQ framework using NVIDIA TensorRT to convert FP32 models into INT8, enabling notable reductions in both model size and inference latency without compromising performance. For example, U-Net's model size shrinks from 23.11 MB to 6.61 MB, and its inference latency drops from 2.62 ms to 1.05 ms, while maintaining the same mean Dice Score (mDSC) of 0.822. |
| 2025 | U-Net INT8 TensorRT (proposed PTQ) proposed | mDSC | 0.822 | post-training-quantization · cases=20 · model=U-Net · engine=TensorRT · classes=13 · precision=INT8 | Post-Training Quantization for 3D Medical Image Segmentation: A Practical Study on Real Inference EnginesSource quoteL11: (b) TensorRT Engine with INT8 Precision. We propose a real PTQ framework using NVIDIA TensorRT to convert FP32 models into INT8, enabling notable reductions in both model size and inference latency without compromising performance. For example, U-Net's model size shrinks from 23.11 MB to 6.61 MB, and its inference latency drops from 2.62 ms to 1.05 ms, while maintaining the same mean Dice Score (mDSC) of 0.822. |
| 2024 | MOSMOS + U-Net (ResNet-50) proposed | Avg. Dice | 80.10% | split: test · fine-tuned · backbone=ResNet-50 · architecture=U-Net | MOSMOS: Multi-organ segmentation facilitated by medical report supervisionSource quoteL267: MOSMOS~(Ours) │ 94.36 │ 93.56 │ 93.81 │ 73.01 │ 72.24 │ 96.11 │ 81.85 │ 89.04 │ 83.72 │ 60.74 │ 76.16 │ 64.95 │ \multicolumn{1}{l|}{61.68} │ 80.10 |
| 2024 | Mamba-3D-UNETR-S proposed | DICE | 83.1 | split: val · subset=split0 · patch-size=16×16×16 · resolution=16x16 · training-samples=24 · validation-samples=6 | Mamba-ND: Selective State Space Modeling for Multi-dimensional DataSource quoteL283: Mamba-3D-UNETR-S │ Mamba │ 36M │ 83.1 │ 8G │ [16, 16, 16] |
| 2024 | nnUNet + Pool Skip proposed | DICE | 82.47% | split: test · five-fold-cross-validation · model=nnUNet · variant=Pool Skip · test-scans=12 | Beyond Skip Connection: Pooling and Unpooling Design for Elimination SingularitiesSource quoteL285: \ \ \ \ +ours │ 82.47 \textcolor[rgb]{ 1, 0, 0}{+0.95} │ 77.00 \textcolor[rgb]{ 1, 0, 0}{+0.90} │ 73.08 \textcolor[rgb]{ 1, 0, 0}{+0.94} |
| 2024 | Probabilistic-aware weakly supervised pipeline proposed | Dice↑ | 0.8279 | semi-supervised · organ=spleen · supervision=point annotations · pseudo-labeling=probabilistic | Enhancing Weakly Supervised 3D Medical Image Segmentation through Probabilistic-aware LearningSource quoteL308: Ours │ 0.8279 │ 0.8157 │ 0.7599 │ 0.7164 │ 63.09 │ 127.16 │ 135.88 │ 116.22 |
| 2024 | APF-UNETR proposed | Dice | 89.7% | hardware=1 GPU · resolution=512×512 | Adaptive Patching for High-resolution Image Segmentation with TransformersSource quoteL593: APF-UNETR │ 2 │ 1067.88 Sec │ 1× │ 89.7 |
| 2024 | LTUDA proposed | average Dice | 89.98% | evaluation=external-generalization · training-data=LSPL | Labeled-to-unlabeled distribution alignment for partially-supervised multi-organ medical image segmentationSource quoteL346: LTUDA (Ours) │ 95.98 │ 95.18 │ 88.69 │ 80.06 │ 89.98 │ 15.34 │ 4.85 │ 16.11 │ 14.14 │ 12.61 |
| 2024 | LoGoNet proposed | Average Dice accuracy | .854 | AVG column; BTCV analysis. The table also lists Gall, Eso, Veins and Lad; the paper rep… | Masked LoGoNet: Fast and Accurate 3D Image Analysis for Medical DomainSource quoteL369: LoGoNet │ .818 │ .786 │ .769 │ .698 │ .854 |
| 2024 | Our SSL Approach (LoGoNet initialized with pre-training) proposed | Average Dice accuracy | .875 | pretraining-clusters=80 | Masked LoGoNet: Fast and Accurate 3D Image Analysis for Medical DomainSource quoteL387: Our SSL Approach │ .866 │ .845 │ .791 │ .757 │ .875 |
| 2024 | PrimGeoSeg (SwinUNETR; 5K FDSL pre-training) proposed | Avg. Dice score | 82.0 | fine-tuned · backbone=SwinUNETR · pretraining=FDSL · pretraining-data=5K | Primitive Geometry Segment Pre-training for 3D Medical Image SegmentationSource quoteL274: PrimGeoSeg │ 5K │ FDSL │ 82.0 │ 95.7 │ 94.4 │ 94.4 │ 61.0 │ 75.5 │ 96.7 │ 83.3 │ 89.1 │ 85.6 │ 75.2 │ 84.3 │ 67.9 │ 62.4 \\[0.8pt] |
| 2024 | RevSAM2 proposed | mDSC | 69.03% | few-shot · organ_subset=13 organs, excluding veins · support_dataset=AbdomenCT | FS-MedSAM2: Exploring the Potential of SAM2 for Few-Shot Medical Image Segmentation without Fine-tuningSource quoteL229: Ours │ \multicolumn{1}{c|}{71.01} │ 69.03 │ \multicolumn{1}{c|}{82.46} │ 77.47 |
| 2024 | Ours (Feat. ✓, Decorr. ✓) proposed | Mean Dice Score | 51.86% | frozen · training-data=100% · pretraining-dataset=AbdomenCT-1K | Overcoming Dimensional Collapse in Self-Supervised Contrastive Learning for Medical Image SegmentationSource quoteL116: Ours │ \checkmark │ \checkmark │ 51.86 │ 79.38 │ 81.22 |
| 2024 | Ours (Feat. ✓, Decorr. ✓) proposed | Mean Dice Score | 79.38% | fine-tuned · training-data=100% · pretraining-dataset=AbdomenCT-1K | Overcoming Dimensional Collapse in Self-Supervised Contrastive Learning for Medical Image SegmentationSource quoteL116: Ours │ \checkmark │ \checkmark │ 51.86 │ 79.38 │ 81.22 |
| 2024 | Ours (Feat. ✓, Decorr. ✓) proposed | Mean Dice Score | 81.22% | fine-tuned · training-data=100% · pretraining-dataset=AbdomenCT-1K | Overcoming Dimensional Collapse in Self-Supervised Contrastive Learning for Medical Image SegmentationSource quoteL116: Ours │ \checkmark │ \checkmark │ 51.86 │ 79.38 │ 81.22 |
| 2023 | DAE proposed | HD (Hausdorff Distance) | 16.82 | split: test · ensemble=four rounds of five-fold cross-validation · resolution=1×1×1 mm | Disruptive Autoencoders: Leveraging Low-level features for 3D Medical Image Pre-trainingSource quoteL138: DAE (Ours) │ 16.82 │ 0.654 │ 0.921 |
| 2023 | DAE proposed | MSD (Mean Surface Distance) | 0.654 | split: test · ensemble=four rounds of five-fold cross-validation · resolution=1×1×1 mm | Disruptive Autoencoders: Leveraging Low-level features for 3D Medical Image Pre-trainingSource quoteL138: DAE (Ours) │ 16.82 │ 0.654 │ 0.921 |
| 2023 | DAE proposed | Dice | 0.921 | split: test · ensemble=four rounds of five-fold cross-validation · resolution=1×1×1 mm | Disruptive Autoencoders: Leveraging Low-level features for 3D Medical Image Pre-trainingSource quoteL138: DAE (Ours) │ 16.82 │ 0.654 │ 0.921 |
| 2023 | FedASAM* proposed | Dice | 75.14 | federated · client=4 · distribution=out-FL · local-rounds=1 · post-processing=none · communication-rounds=500 | UFPS: A unified framework for partially annotated federated segmentation in heterogeneous data distributionSource quoteL375: FedASAM* │ 77.02 / 1.39 │ 78.15 / 2.91 │ 65.60 / 1.75 │ 75.14 / 1.71 │ 73.97 / 1.94 │ 74.20 / 1.63 |
| 2023 | COSST proposed | Average Dice score (DSC) | 87.76% | task=Task 1 | COSST: Multi-Organ Segmentation With Partially Labeled Datasets Using Comprehensive Supervisions and Self-TrainingSource quoteL333: In Tab. \ref{tab4}, we show the segmentation performance of the compared methods for the public datasets in task1. First, we observe that it is more beneficial to learn a single unified model from partially labeled datasets than the baseline Multi-Nets, especially for the organs whose training set is small, e.g., spleen (N=20). For example, by comparing the Multi-Nets to the proposed COSST, we can observe that the average Dice score improves from 86.25% to 89.08%, the average HD95 improves from 16.85 to 5.36, and the average ASD improves from 3.38 to 1.16. By comparing the segmentation performance across three evaluated datasets, we notice that the segmentation performance of all compared methods decreases from the held-out testing set to the external datasets, e.g., the average Dice score of COSST drops from 92.13% to 87.76% and 87.37% for BTCV and AMOS2022, respectively. However, we find that COSST consistently yields more reliable segmentation results than other methods under the domain shift. For instance, by the comparing the COSST to the second best approach, we show that the segmentation results of COSST have much better boundary matching, i.e., 6.23 vs. 11.24 and 6.29 vs. 11.01 respectively for BTCV and AMOS2022. For ground truth based supervision methods, we observe that TAL and ME achieve comparable results in Dice scores but TAL slightly outperforms ME in HD95 and ASD. In addition, we notice that the pseudo-label based methods such as PLT and co-training achieve better segmentation performance than the non-pseudo label based methods, i.e., TAL and ME, demonstrating the importance of the pseudo label learning. Furthermore, comparing the pseudo label based methods (e.g., PLT) to our proposed COSST, we observe that COSST not only achieves overall higher Dice scores, but also much better performance in distance-based metrics HD95 and ASD (ASD: 1.16 vs. 2.51, and HD95: 5.36 vs. 14.91), indicating the effectiveness of our strategy for pseudo label learning, i.e., pseudo label filtering with self-training. Overall, COSST achieves consistent superior segmentation performance than all compared methods on all three evaluated CT datasets, especially in the distance-based metrics HD95 and ASD. |
| 2023 | BTI module proposed | Runtimes | 155.5 s | runtime-granularity=single-epoch | NexToU: Efficient Topology-Aware U-Net for Medical Image SegmentationSource quoteL123: BTI │ 155.5 |
| 2023 | SPAD-ViT (fine-tuned from pre-trained weights; table label “Ours”) proposed | Dice | 77.84 | split: val · fine-tuned · training-data=20% (4 labeled samples) · training-steps=50K | Building Universal Foundation Models for Medical Image Analysis with Spatially Adaptive NetworksSource quoteL427: 0.2 │ 70.98 │ 77.84 │ 6.85 │ 4.96 │ 2.39 │ 2.57 │ 51.13 │ 25.56 │ 25.57 |
| 2023 | SPAD-ViT (fine-tuned from pre-trained weights; table label “Ours”) proposed | ASSD | 2.39 | split: val · fine-tuned · training-data=20% (4 labeled samples) · training-steps=50K | Building Universal Foundation Models for Medical Image Analysis with Spatially Adaptive NetworksSource quoteL427: 0.2 │ 70.98 │ 77.84 │ 6.85 │ 4.96 │ 2.39 │ 2.57 │ 51.13 │ 25.56 │ 25.57 |
| 2023 | SPAD-ViT (fine-tuned from pre-trained weights; table label “Ours”) proposed | HD | 25.56 | split: val · fine-tuned · training-data=20% (4 labeled samples) · training-steps=50K | Building Universal Foundation Models for Medical Image Analysis with Spatially Adaptive NetworksSource quoteL427: 0.2 │ 70.98 │ 77.84 │ 6.85 │ 4.96 │ 2.39 │ 2.57 │ 51.13 │ 25.56 │ 25.57 |
| 2023 | nnUnet with AFA-MI proposed | DSC | 0.85 | split: test · backbone=nnU-Net · augmentation=AFA-MI | Deep learning-based multi-organ CT segmentation with adversarial data augmentationSource quoteL13: We firstly evaluate the AFA-MI augmentation using nnUnet and Token-based Transformer Vnet (TT-Vnet) on the test data from a public abdominal dataset and an institutional dataset. In addition, we validate how AFA-MI affects the networks’ robustness to the noisy data by evaluating the networks with added Gaussian noises of varying magnitudes to the institutional dataset. Network performance is quantitatively evaluated using Dice Similarity Coefficient (DSC) for volume-based accuracy. Also, Hausdorff Distance (HD) is applied for surface-based accuracy. On the public dataset, nnUnet with AFA-MI achieves DSC = 0.85 and HD = 6.16 millimeters (mm); and TT-Vnet achieves DSC = 0.86 and HD |
| 2023 | TT-Vnet with AFA-MI proposed | DSC | 0.86 | split: test · backbone=TT-VNet · augmentation=AFA-MI | Deep learning-based multi-organ CT segmentation with adversarial data augmentationSource quoteL13: We firstly evaluate the AFA-MI augmentation using nnUnet and Token-based Transformer Vnet (TT-Vnet) on the test data from a public abdominal dataset and an institutional dataset. In addition, we validate how AFA-MI affects the networks’ robustness to the noisy data by evaluating the networks with added Gaussian noises of varying magnitudes to the institutional dataset. Network performance is quantitatively evaluated using Dice Similarity Coefficient (DSC) for volume-based accuracy. Also, Hausdorff Distance (HD) is applied for surface-based accuracy. On the public dataset, nnUnet with AFA-MI achieves DSC = 0.85 and HD = 6.16 millimeters (mm); and TT-Vnet achieves DSC = 0.86 and HD |
| 2023 | C-SliceGen proposed | SSIM ↑ | 0.603 | split: test · beta=0 · evaluation=3D volumetric · target-slice-selection=registration | Deep conditional generative models for longitudinal single-slice abdominal computed tomography harmonizationSource quoteL165: \beta = 0, Registration │ 0.603 │ 17.367 │ 0.362 │ 0.340 |
| 2023 | C-SliceGen proposed | SSIM ↑ | 0.605 | split: test · beta=0 · evaluation=3D volumetric · target-slice-selection=BPR | Deep conditional generative models for longitudinal single-slice abdominal computed tomography harmonizationSource quoteL166: \beta = 0, BPR │ 0.605 │ 17.546 │ 0.376 │ 0.330 |
| 2023 | Ours (Model Adaptation + Model Ensemble), multi-organ student proposed | DSC | 91.67% | organ=liver-and-spleen · source-domains=LiTS-and-RS | Tailored multi-organ segmentation with model adaptation and ensembleSource quoteL373: Ours │ {×} │ both │ 88.59 │ 2.03 │ 80.78 │ 1.74 │ 91.67 │ 2.14 │ 89.69 │ 1.46 |
| 2023 | RecycleNet proposed | Average DSC | 87.80 | split: test · inference-cycles=7 | RecycleNet: Latent Feature Recycling Leads to Iterative Decision RefinementSource quoteL94: RecycleNet │ 90.26 │ 89.11 │ 83.75 │ 87.80 │ 94.92 │ 93.48 │ 91.85 │ 88.77 │ 90.82 │ 79.88 |
| 2023 | MedNeXt-L proposed | DSC | 88.76 | split: val · ensemble=5-fold · kernel_size=5×5×5 · initialization=UpKern | MedNeXt: Transformer-Driven Scaling of ConvNets for Medical Image SegmentationSource quoteL190: \multirow{4}{*}{MedNeXt} │ BTCV │ 88.76 |
| 2022 | MixCL-pretrained UNETR encoder proposed | Dice coefficient | 0.3871 | split: val · fine-tuned · backbone=UNETR · labeled-data=15% | MixCL: Pixel label matters to contrastive learningSource quoteL122: 15% │ 0.8247 │ 0.8430 │ +0.0183 │ 15% │ 0.2459 │ 0.3871 │ +0.1412 |
| 2022 | APAUNet proposed | Average Dice | 87.84 | Reported average score in the BTCV comparison results. | APAUNet: Axis Projection Attention UNet for Small Target in 3D Medical SegmentationSource quoteL282: Our APAUNet achieves the best average dice score of 87.84 and the best average HD95 score of 11.26, |
| 2022 | APAUNet proposed | Dice | 49.4 | target-size=0-0.1% of input | APAUNet: Axis Projection Attention UNet for Small Target in 3D Medical SegmentationSource quoteL304: Concretely, on the interval of 0 \sim 0.1%, our APAUNet achieves dice scores of 51.3, 55.1 and 49.4 on three datasets respectively, |
| 2022 | mlTPSN proposed | Average Dice | 83.49 | scope=multi-object · template=bounding-box masks | A Learning-based Framework for Topology-Preserving Segmentation using Quasiconformal MappingsSource quoteL296: mlTPSN │ \B{83.49} │ 89.33 │ 89.10 │ \B{89.13} │ 82.11 │ 90.43 │ 87.07 │ \B{68.38} │ \B{72.40} |
| 2022 | mlTPSN proposed | Average HD (Hausdorff distance) | 4.69 | scope=multi-object · template=bounding-box masks | A Learning-based Framework for Topology-Preserving Segmentation using Quasiconformal MappingsSource quoteL303: mlTPSN │ \B{4.69} │ \B{5.13} │ \B{3.33} │ \B{3.47} │ \B{3.27} │ 9.97 │ \B{6.12} │ \B{3.13} │ \B{3.06} |
| 2021 | Swin UNETR proposed | Dice (average over 13 organs) | 0.908 | organs=13 | Self-Supervised Pre-Training of Swin Transformers for 3D Medical Image AnalysisSource quoteL335: We extensively compare the benchmarks of our model with baselines. The published leaderboard evaluation is shown in Table~\ref{tab:tab2}. Compared with other top submissions, the proposed Swin UNETR achieves the best performance. We obtain the state-of-the-art Dice of 0.908, outperforming the second, third and fourth top-ranked baselines by 1.6%, 2.0% and 2.4% on average of 13 organs, respectively. Distinct improvements can be specifically observed for organs that are smaller in size, such as splenic and portal veins of 3.6% against prior state-of-the-art method, pancreas of 1.6%, and adrenal glands of 3.8%. Moderate improvements are observed in other organs. The representative samples in Fig.~\ref{fig:fig4} demonstrate the success of identifying organ details by Swin UNETR. Our method detects the pancreas tail (row 1), and branches in the portal vein (row 2) in Fig.~\ref{fig:fig4}, where other methods under segment parts of each tissue. In addition, our method demonstrates distinct improvement in segmentation of adrenal glands (row 3). |
| 2021 | MI+Labelcrop proxy data proposed non-standard slice | correlation | 0.37 | split: external-validation · organ=spleen · subset=24% of full dataset | The Power of Proxy Data and Proxy Networks for Hyper-parameter Optimization in Medical Image SegmentationSource quoteL110: Observing across the entire hyper-parameter space the proxy data selection method MI+Labelcrop shows a higher correlation of 0.37 versus 0.32 as compared to random selection of data on the external validation when being compared with the ground truth which is obtained by training with all the data (shown in Fig.~\ref{fig2:proxy_data_spleen}). |
| 2021 | UNETR proposed | overall average Dice score | 0.899 | split: test · ensemble=four five-fold cross-validations · competition=Free Competition · training-cases=80 | UNETR: Transformers for 3D Medical Image SegmentationSource quoteL387: UNETR outperforms the state-of-the-art methods for both Standard and Free Competitions on the BTCV leaderboard. As shown in Table~\ref{tab:BTCV}, in the Free Competition, UNETR achieves an overall average Dice score of 0.899 and outperforms the second, third and fourth top-ranked methodologies by 1.238%, 1.696% and 5.269% respectively. |
| 2021 | UNETR proposed | average Dice score across all organs | 85.3% | split: test · ensemble=four five-fold cross-validations · competition=Standard Competition | UNETR: Transformers for 3D Medical Image SegmentationSource quoteL389: In the Standard Competition, we compared the performance of UNETR against CNN and transformer-based baselines. UNETR achieves a new state-of-the-art performance with an average Dice score of 85.3% on all organs. Specifically, on large organs, such as spleen, liver and stomach, our method outperforms the second best baselines by 1.043%, 0.830% and 2.125% respectively,in terms of Dice score. Furthermore, in segmentation of small organs, our method significantly outperforms the second best baselines by 6.382% and 6.772% on gallbladder and adrenal glands respectively, in terms of Dice score. |