BTCV

60 papers · 128 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

79.780.581.382.02025VOILA (V-L Interaction + Random sampling): 79.9 (2025)VOILA (Ts-v2-trained, without fine-tuning): 81.4 (2025)VOILA (V-L Interaction + CAS): 81.4 (2025)SegVol (text+bbox): 81.87 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 21 of 21 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025MambaMIM-pretrained HyMamba proposedDSC (Avg)80.16%split: val · fine-tuned · backbone=HyMamba · evaluation=five-fold-cross-validation · pretraining=MambaMIMMambaMIM: Pre-training Mamba with state space token interpolation and its application to medical image segmentation
Source quote
L522: 80.16
2025AutoProSAM (P&M) proposedmDice87.15split: test · fine-tuned · classes=13 · modality=CT · dimension=3DAutoProSAM: Automated Prompting SAM for 3D Multi-Organ Segmentation
Source quote
L282: 87.15
2025MedDelinea proposedmDSC87.01%fine-tuned · pretraining=ATLAS-8kMedDelinea: Scalable and Efficient Medical Image Segmentation via Controllable Diffusion Transformers
Source quote
L388: MedDelinea’s performance in fine-tuning and zero-shot learning scenarios. After fine-tuning on each dataset post ATLAS-8k pre-training, MedDelinea achieves the highest metrics, including an mDSC of 87.01% on BTCV and 82.19% on AMOS. In zero-shot learning, MedDelinea demonstrates robust generalization capabilities, leading with an mDSC of 80.01% on BTCV and 78.67% on AMOS. This suggests that MedDelinea’s architecture is adaptable and effective in transferring learned features from pre-training to new datasets.
2025SimCroP proposedDice80.7fine-tuned · subset=100% · backbone=3D ViT-BSimCroP: Radiograph Representation Learning with Similarity-Driven Cross-Granularity Pre-training
Source quote
L122: SimCroP\xspace (Ours) │ 93.5 │ 93.7 │ 80.7
2025HyMamba (trained from scratch; no pre-training) ablationDSC (Avg)77.56%split: val · fine-tuned · backbone=HyMamba · evaluation=five-fold-cross-validation · pretraining=noneMambaMIM: Pre-training Mamba with state space token interpolation and its application to medical image segmentation
Source quote
L509: 77.56
2025MedSAM (Full) baselinemDice84.57split: test · fine-tuned · classes=13 · modality=CT · dimension=3DAutoProSAM: Automated Prompting SAM for 3D Multi-Organ Segmentation
Source quote
L276: 84.57
2025M3AE baselineDice80.5fine-tuned · subset=100% · backbone=3D ViT-BSimCroP: Radiograph Representation Learning with Similarity-Driven Cross-Granularity Pre-training
Source quote
L117: M3AE~\cite{chen2022m3ae} │ 93.1 │ 93.7 │ 80.5
2024MOSMOS + U-Net (ResNet-50) proposedAvg. Dice80.10%split: test · fine-tuned · backbone=ResNet-50 · architecture=U-NetMOSMOS: Multi-organ segmentation facilitated by medical report supervision
Source quote
L267: MOSMOS~(Ours) │ 94.36 │ 93.56 │ 93.81 │ 73.01 │ 72.24 │ 96.11 │ 81.85 │ 89.04 │ 83.72 │ 60.74 │ 76.16 │ 64.95 │ \multicolumn{1}{l|}{61.68} │ 80.10
2024PrimGeoSeg (SwinUNETR; 5K FDSL pre-training) proposedAvg. Dice score82.0fine-tuned · backbone=SwinUNETR · pretraining=FDSL · pretraining-data=5KPrimitive Geometry Segment Pre-training for 3D Medical Image Segmentation
Source quote
L274: PrimGeoSeg │ 5K │ FDSL │ 82.0 │ 95.7 │ 94.4 │ 94.4 │ 61.0 │ 75.5 │ 96.7 │ 83.3 │ 89.1 │ 85.6 │ 75.2 │ 84.3 │ 67.9 │ 62.4 \\[0.8pt]
2024Ours (Feat. ✓, Decorr. ✓) proposedMean Dice Score79.38%fine-tuned · training-data=100% · pretraining-dataset=AbdomenCT-1KOvercoming Dimensional Collapse in Self-Supervised Contrastive Learning for Medical Image Segmentation
Source quote
L116: Ours │ \checkmark │ \checkmark │ 51.86 │ 79.38 │ 81.22
2024Ours (Feat. ✓, Decorr. ✓) proposedMean Dice Score81.22%fine-tuned · training-data=100% · pretraining-dataset=AbdomenCT-1KOvercoming Dimensional Collapse in Self-Supervised Contrastive Learning for Medical Image Segmentation
Source quote
L116: Ours │ \checkmark │ \checkmark │ 51.86 │ 79.38 │ 81.22
2024ImageNet + U-Net (ResNet-50) baselineAvg. Dice76.73%split: test · fine-tuned · backbone=ResNet-50 · architecture=U-NetMOSMOS: Multi-organ segmentation facilitated by medical report supervision
Source quote
L260: ImageNet~\cite{deng2009imagenet} │ 92.87 │ 91.16 │ 91.87 │ 60.00 │ 69.83 │ 96.19 │ 71.08 │ 89.80 │ 81.84 │ 67.59 │ 73.99 │ 58.03 │ \multicolumn{1}{l|}{53.20} │ 76.73
2024Swin UNETR* baselineDice91.8%fine-tuned · hardware=1 GPU · patch-size=4 · resolution=512×512 · pretraining=five datasetsAdaptive Patching for High-resolution Image Segmentation with Transformers
Source quote
L591: Swin UNETR (*)~\cite{DBLP:conf/cvpr/TangY0RLXNH22} │ 4 │ 6609.45 Sec │ 6.19× │ 91.8
2024Scratch (SwinUNETR; no pre-training) baselineAvg. Dice score78.3fine-tuned · backbone=SwinUNETR · pretraining=nonePrimitive Geometry Segment Pre-training for 3D Medical Image Segmentation
Source quote
L272: Scratch │ 0 │ -- │ 78.3 │ 92.3 │ 93.2 │ 93.8 │ 55.9 │ 61.3 │ 94.0 │ 77.0 │ 87.5 │ 80.4 │ 74.2 │ 76.1 │ 68.8 │ 63.6
2024MoCo v2 baselineMean Dice Score78.21%fine-tuned · training-data=100% · pretraining-dataset=AbdomenCT-1KOvercoming Dimensional Collapse in Self-Supervised Contrastive Learning for Medical Image Segmentation
Source quote
L113: MoCo v2 │ 44.30 │ 78.21 │ 81.09
2024MoCo v2 baselineMean Dice Score81.09%fine-tuned · training-data=100% · pretraining-dataset=AbdomenCT-1KOvercoming Dimensional Collapse in Self-Supervised Contrastive Learning for Medical Image Segmentation
Source quote
L113: MoCo v2 │ 44.30 │ 78.21 │ 81.09
2023SPAD-ViT (fine-tuned from pre-trained weights; table label “Ours”) proposedDice77.84split: val · fine-tuned · training-data=20% (4 labeled samples) · training-steps=50KBuilding Universal Foundation Models for Medical Image Analysis with Spatially Adaptive Networks
Source quote
L427: 0.2 │ 70.98 │ 77.84 │ 6.85 │ 4.96 │ 2.39 │ 2.57 │ 51.13 │ 25.56 │ 25.57
2023SPAD-ViT (fine-tuned from pre-trained weights; table label “Ours”) proposedASSD2.39split: val · fine-tuned · training-data=20% (4 labeled samples) · training-steps=50KBuilding Universal Foundation Models for Medical Image Analysis with Spatially Adaptive Networks
Source quote
L427: 0.2 │ 70.98 │ 77.84 │ 6.85 │ 4.96 │ 2.39 │ 2.57 │ 51.13 │ 25.56 │ 25.57
2023SPAD-ViT (fine-tuned from pre-trained weights; table label “Ours”) proposedHD25.56split: val · fine-tuned · training-data=20% (4 labeled samples) · training-steps=50KBuilding Universal Foundation Models for Medical Image Analysis with Spatially Adaptive Networks
Source quote
L427: 0.2 │ 70.98 │ 77.84 │ 6.85 │ 4.96 │ 2.39 │ 2.57 │ 51.13 │ 25.56 │ 25.57
2022MixCL-pretrained UNETR encoder proposedDice coefficient0.3871split: val · fine-tuned · backbone=UNETR · labeled-data=15%MixCL: Pixel label matters to contrastive learning
Source quote
L122: 15% │ 0.8247 │ 0.8430 │ +0.0183 │ 15% │ 0.2459 │ 0.3871 │ +0.1412
2022UNETR trained from scratch baselineDice coefficient0.2459split: val · fine-tuned · backbone=UNETR · labeled-data=15%MixCL: Pixel label matters to contrastive learning
Source quote
L122: 15% │ 0.8247 │ 0.8430 │ +0.0183 │ 15% │ 0.2459 │ 0.3871 │ +0.1412