BTCV

60 papers · 128 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

79.780.581.382.02025VOILA (V-L Interaction + Random sampling): 79.9 (2025)VOILA (Ts-v2-trained, without fine-tuning): 81.4 (2025)VOILA (V-L Interaction + CAS): 81.4 (2025)SegVol (text+bbox): 81.87 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 7 of 7 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025MedDelinea proposedmDSC87.01%fine-tuned · pretraining=ATLAS-8kMedDelinea: Scalable and Efficient Medical Image Segmentation via Controllable Diffusion Transformers
Source quote
L388: MedDelinea’s performance in fine-tuning and zero-shot learning scenarios. After fine-tuning on each dataset post ATLAS-8k pre-training, MedDelinea achieves the highest metrics, including an mDSC of 87.01% on BTCV and 82.19% on AMOS. In zero-shot learning, MedDelinea demonstrates robust generalization capabilities, leading with an mDSC of 80.01% on BTCV and 78.67% on AMOS. This suggests that MedDelinea’s architecture is adaptable and effective in transferring learned features from pre-training to new datasets.
2025MedDelinea proposedmDSC80.01%0-shot · pretraining=ATLAS-8kMedDelinea: Scalable and Efficient Medical Image Segmentation via Controllable Diffusion Transformers
Source quote
L388: MedDelinea’s performance in fine-tuning and zero-shot learning scenarios. After fine-tuning on each dataset post ATLAS-8k pre-training, MedDelinea achieves the highest metrics, including an mDSC of 87.01% on BTCV and 82.19% on AMOS. In zero-shot learning, MedDelinea demonstrates robust generalization capabilities, leading with an mDSC of 80.01% on BTCV and 78.67% on AMOS. This suggests that MedDelinea’s architecture is adaptable and effective in transferring learned features from pre-training to new datasets.
2025MedDelinea proposedmDSC77.52%split: test · few-shot · subset=1% of training data · pretraining=ATLAS-8kMedDelinea: Scalable and Efficient Medical Image Segmentation via Controllable Diffusion Transformers
Source quote
L350: 77.52
2025U-Net INT8 TensorRT (proposed PTQ) proposedmDSC0.822post-training-quantization · cases=20 · model=U-Net · engine=TensorRT · classes=13 · precision=INT8Post-Training Quantization for 3D Medical Image Segmentation: A Practical Study on Real Inference Engines
Source quote
L11: (b) TensorRT Engine with INT8 Precision. We propose a real PTQ framework using NVIDIA TensorRT to convert FP32 models into INT8, enabling notable reductions in both model size and inference latency without compromising performance. For example, U-Net's model size shrinks from 23.11 MB to 6.61 MB, and its inference latency drops from 2.62 ms to 1.05 ms, while maintaining the same mean Dice Score (mDSC) of 0.822.
2025U-Net FP32 reference baselinemDSC0.822cases=20 · model=U-Net · classes=13 · precision=FP32Post-Training Quantization for 3D Medical Image Segmentation: A Practical Study on Real Inference Engines
Source quote
L11: (b) TensorRT Engine with INT8 Precision. We propose a real PTQ framework using NVIDIA TensorRT to convert FP32 models into INT8, enabling notable reductions in both model size and inference latency without compromising performance. For example, U-Net's model size shrinks from 23.11 MB to 6.61 MB, and its inference latency drops from 2.62 ms to 1.05 ms, while maintaining the same mean Dice Score (mDSC) of 0.822.
2024RevSAM2 proposedmDSC69.03%few-shot · organ_subset=13 organs, excluding veins · support_dataset=AbdomenCTFS-MedSAM2: Exploring the Potential of SAM2 for Few-Shot Medical Image Segmentation without Fine-tuning
Source quote
L229: Ours │ \multicolumn{1}{c|}{71.01} │ 69.03 │ \multicolumn{1}{c|}{82.46} │ 77.47
2024ResT image encoder with RFF baselinemDSC61.5method=RFF · encoder=ResTTowards a Comprehensive, Efficient and Promptable Anatomic Structure Segmentation Model Using 3D Whole-Body CT Scans
Source quote
L259: ResT │ \checkmark │ 73.1 │ 81.4 │ 61.5 │ 72.8