BTCV

60 papers · 128 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

79.780.581.382.02025VOILA (V-L Interaction + Random sampling): 79.9 (2025)VOILA (Ts-v2-trained, without fine-tuning): 81.4 (2025)VOILA (V-L Interaction + CAS): 81.4 (2025)SegVol (text+bbox): 81.87 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 4 of 4 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025MedDINOv3 proposedDSC78.79%split: val · evaluation=one-fold-of-5-fold-cross-validationMedDINOv3: How to adapt vision foundation models for medical image segmentation?
Source quote
L145: MedDINOv3 (ours) │ 87.38 │ 70.68 │ 75.28 │ 78.79 │ 77.15 │ 62.67 │ 53.01 │ 70.38
2025Step 0 U-Net (RFMedSAM 2 prompt-generation pipeline) ablationDSC0.856split: val · stage=Step 0 U-NetRFMedSAM 2: Automatic Prompt Refinement for Enhanced Volumetric Medical Image Segmentation with SAM 2
Source quote
L259: Dataset │ Step 0 - UNet │ Step 1 - SAM │ Step 2 - SAM BTCV │ 0.856 │ 0.864 │ 0.867
2025nnU-Net baselineDSC73.30%split: val · evaluation=one-fold-of-5-fold-cross-validationMedDINOv3: How to adapt vision foundation models for medical image segmentation?
Source quote
L142: nnU-Net │ 84.81 │ 69.15 │ 75.00 │ 73.30 │ 73.98 │ 64.85 │ 53.02 │ 64.66
2023MedNeXt-L proposedDSC88.76split: val · ensemble=5-fold · kernel_size=5×5×5 · initialization=UpKernMedNeXt: Transformer-Driven Scaling of ConvNets for Medical Image Segmentation
Source quote
L190: \multirow{4}{*}{MedNeXt} │ BTCV │ 88.76