BTCV
60 papers · 128 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | SegVol (text+bbox) SOTA frontier | 81.87 | 2025-03-01 | prompt=text+bbox · Known-anatomy abdominal CT; text combined with a bounding-box prompt, compared with S… | Zero-shot Domain Generalization of Foundational Models for 3D Medical Image Segmentation: An Experimental StudySource quote\keypoint{Text inputs boost spatial prompts.} We investigate the effect of semantic prompts as an additional guidance alongside spatial prompts for SegVol~\cite{segvol}, denoted by ``text+bbox'' and ``text+points'' in \autoref{tab:sec4p3}. Comparing them with corresponding vanilla spatial prompts in \autoref{tab:sec4p2}, we notice that for known anatomies (abdominal CT and MR), the addition of text consistently improves segmentations from raw spatial prompts (BTCV: 80.15 w/ bbox, 81.87 w/ text+bbox; CHAOS: 80.25 w/ points, 81.06 w/ text+points). We show example segmentation results in \autoref{fig:bbox_text}. For unseen anatomies, text prompts completely fail, since the model has no knowledge to spatially ground such concepts. |
| 2 | VOILA (Ts-v2-trained, without fine-tuning) SOTA frontier | 81.4 | 2025-01-01 | fine-tuning=none · training-dataset=Ts-v2 · Trained on Ts-v2 with contrastive loss and evaluated on the BTCV test set without fin… | VOILA: Complexity-Aware Universal Segmentation of CT Images by Voxel Interacting with LanguageSource quote81.4(+7.3) |
| 3 | VOILA (V-L Interaction + CAS) SOTA frontier (+1 variant) | 81.4 | 2025-01-01 | sampling-ratio=0.1 · training-dataset=Ts-v2 · Sampling ratio 0.1; trained on Ts-v2 and inferred on BTCV without fine-tuning. | VOILA: Complexity-Aware Universal Segmentation of CT images by Voxel Interacting with LanguageSource quote\ding{52} │ CAS │ 0.1 │ 92.1 │ 11.2 │ 81.4 │ 80.9 │ 16.0 │ 81.2 │ 71.7 │ 20.6 |
Regimefine-tuned (21)0-shot (13)post-training-quantization (3)class-incremental (2)supervised (2)five-fold-cross-validation (2)
Showing 2 of 2 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2023 | nnUnet with AFA-MI proposed | DSC | 0.85 | split: test · backbone=nnU-Net · augmentation=AFA-MI | Deep learning-based multi-organ CT segmentation with adversarial data augmentationSource quoteL13: We firstly evaluate the AFA-MI augmentation using nnUnet and Token-based Transformer Vnet (TT-Vnet) on the test data from a public abdominal dataset and an institutional dataset. In addition, we validate how AFA-MI affects the networks’ robustness to the noisy data by evaluating the networks with added Gaussian noises of varying magnitudes to the institutional dataset. Network performance is quantitatively evaluated using Dice Similarity Coefficient (DSC) for volume-based accuracy. Also, Hausdorff Distance (HD) is applied for surface-based accuracy. On the public dataset, nnUnet with AFA-MI achieves DSC = 0.85 and HD = 6.16 millimeters (mm); and TT-Vnet achieves DSC = 0.86 and HD |
| 2023 | TT-Vnet with AFA-MI proposed | DSC | 0.86 | split: test · backbone=TT-VNet · augmentation=AFA-MI | Deep learning-based multi-organ CT segmentation with adversarial data augmentationSource quoteL13: We firstly evaluate the AFA-MI augmentation using nnUnet and Token-based Transformer Vnet (TT-Vnet) on the test data from a public abdominal dataset and an institutional dataset. In addition, we validate how AFA-MI affects the networks’ robustness to the noisy data by evaluating the networks with added Gaussian noises of varying magnitudes to the institutional dataset. Network performance is quantitatively evaluated using Dice Similarity Coefficient (DSC) for volume-based accuracy. Also, Hausdorff Distance (HD) is applied for surface-based accuracy. On the public dataset, nnUnet with AFA-MI achieves DSC = 0.85 and HD = 6.16 millimeters (mm); and TT-Vnet achieves DSC = 0.86 and HD |