BTCV

60 papers · 128 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

79.780.581.382.02025VOILA (V-L Interaction + Random sampling): 79.9 (2025)VOILA (Ts-v2-trained, without fine-tuning): 81.4 (2025)VOILA (V-L Interaction + CAS): 81.4 (2025)SegVol (text+bbox): 81.87 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 1 of 1 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2023SSH-UNetaccuracy84.35%split: valSpatiotemporal Modeling Encounters 3D Medical Image Analysis: Slice-Shift UNet with Multi-View Fusion
Source quote
L184: In Table \ref{tab:per_organ_kfold} we can see the results of 5-fold cross-validation on the BTCV dataset. On average our model is able to reach 84.35% of accuracy without the help of any ensemble. From the table, we can observe that the fourth-fold segmentation of the spleen shows a significant drop in performance. The gallbladder and adrenal glands are segmented poorly by the first and second folds compared to the others. The first fold also led to a bad segmentation mask for the esophagus, liver, and stomach. We want to highlight that the official BTCV webpage emphasizes that some patients may not have the right kidney or gallbladder and thus are not labelled; however, our network is capable of segmenting the right kidney independently of the folds, while the drop in performance in the second fold in the gallbladder may be related to the lack of annotated data.