BraTS 2019 · Medical Image Segmentation

32 papers · 83 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Also indexed as: brats-2019

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Medical Image Segmentation, split=val.

81.181.782.382.8202220232024Med-DANet: 82.72 (2022)FreMIM: 81.25 (2024)Med-DANet V2: 81.28 (2024)
Click any point on the timeline to inspect method, protocol, and paper.
#MethodScore ↑YearProtocol / SettingsPaper & Evidence
1Med-DANet SOTA frontier82.72%2022-01-01setting=Setting 2 (without sliding window) · Setting 2 (w/o slide window).Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric Segmentation
Source quote
Ours │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74
2Med-DANet V281.28%2024-01-01region=TC · Validation set; TC region.Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric Segmentation
Source quote
\bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15
3FreMIM81.25%2024-01-01region=TC · Brain tumor segmentation; tumor core (TC) region. The cited prose does not specify th…FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image Segmentation
Source quote
\paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm.
Other primary task on BraTS 2019: Medical Image Segmentation · Dice score (WT) ↑ (%) · val (3 papers)
#MethodScore ↑YearProtocol / SettingsPaper & Evidence
1Med-DANet SOTA frontier90.65%2022-01-01setting=Setting 2 (without sliding window) · Setting 2 (w/o slide window).Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric Segmentation
Source quote
Ours │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74
2Med-DANet V290.27%2024-01-01region=WT · Validation set; WT region.Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric Segmentation
Source quote
\bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15
3FreMIM90.23%2024-01-01region=WT · Brain tumor segmentation; whole tumor (WT) region. The cited prose does not specify t…FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image Segmentation
Source quote
\paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm.
Other primary task on BraTS 2019: Medical Image Segmentation · Dice score (ET) ↑ (%) · val (2 papers)
#MethodScore ↑YearProtocol / SettingsPaper & Evidence
1Med-DANet V2 SOTA frontier80.08%2024-01-01region=ET · Validation set; ET region.Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric Segmentation
Source quote
\bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15
2FreMIM79.74%2024-01-01region=ET · Brain tumor segmentation; enhancing tumor (ET) region. The cited prose does not speci…FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image Segmentation
Source quote
\paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm.