BraTS 2019 · Medical Image Segmentation
32 papers · 83 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Also indexed as: brats-2019
Tasks on BraTS 2019All tasks (32)Medical Image Segmentation (15)Brain Tumor Segmentation (6)Anomaly Detection (2)Image Segmentation (2)3D Segmentation (1)Image to Image Translation (1)Mr Image Translation (1)Slice Index Regression (1)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Medical Image Segmentation, split=val.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Med-DANet SOTA frontier | 82.72% | 2022-01-01 | setting=Setting 2 (without sliding window) · Setting 2 (w/o slide window). | Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric SegmentationSource quoteOurs │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74 |
| 2 | Med-DANet V2 | 81.28% | 2024-01-01 | region=TC · Validation set; TC region. | Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric SegmentationSource quote\bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15 |
| 3 | FreMIM | 81.25% | 2024-01-01 | region=TC · Brain tumor segmentation; tumor core (TC) region. The cited prose does not specify th… | FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image SegmentationSource quote\paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm. |
Other primary task on BraTS 2019: Medical Image Segmentation · Dice score (WT) ↑ (%) · val (3 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Med-DANet SOTA frontier | 90.65% | 2022-01-01 | setting=Setting 2 (without sliding window) · Setting 2 (w/o slide window). | Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric SegmentationSource quoteOurs │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74 |
| 2 | Med-DANet V2 | 90.27% | 2024-01-01 | region=WT · Validation set; WT region. | Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric SegmentationSource quote\bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15 |
| 3 | FreMIM | 90.23% | 2024-01-01 | region=WT · Brain tumor segmentation; whole tumor (WT) region. The cited prose does not specify t… | FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image SegmentationSource quote\paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm. |
Other primary task on BraTS 2019: Medical Image Segmentation · Dice score (ET) ↑ (%) · val (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Med-DANet V2 SOTA frontier | 80.08% | 2024-01-01 | region=ET · Validation set; ET region. | Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric SegmentationSource quote\bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15 |
| 2 | FreMIM | 79.74% | 2024-01-01 | region=ET · Brain tumor segmentation; enhancing tumor (ET) region. The cited prose does not speci… | FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image SegmentationSource quote\paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm. |
TaskMedical Image Segmentation (45)Brain Tumor Segmentation (15)Anomaly Detection (4)Survival Prediction (3)Image Segmentation (3)Mr Image Translation (3)Image to Image Translation (2)
Regimesemi-supervised (10)unsupervised-domain-adaptation (4)weakly-supervised (3)unpaired (3)one-class (2)fully-supervised (2)
Showing 16 of 16 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2023 | Med-DANet V2 proposed | Dice score (ET) | 80.08% | Medical Image Segmentation · split: val · region=ET | Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric SegmentationSource quoteL194: \bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15 |
| 2023 | Med-DANet V2 proposed | Dice score (WT) | 90.27% | Medical Image Segmentation · split: val · region=WT | Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric SegmentationSource quoteL194: \bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15 |
| 2023 | Med-DANet V2 proposed | Dice score (TC) | 81.28% | Medical Image Segmentation · split: val · region=TC | Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric SegmentationSource quoteL194: \bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15 |
| 2023 | FreMIM proposed | Dice score (ET) | 79.74% | Medical Image Segmentation · split: val · region=ET | FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image SegmentationSource quoteL264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm. |
| 2023 | FreMIM proposed | Dice score (WT) | 90.23% | Medical Image Segmentation · split: val · region=WT | FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image SegmentationSource quoteL264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm. |
| 2023 | FreMIM proposed | Dice score (TC) | 81.25% | Medical Image Segmentation · split: val · region=TC | FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image SegmentationSource quoteL264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm. |
| 2023 | FreMIM proposed | Hausdorff distance (95%) (TC) | 6.934mm | Medical Image Segmentation · split: val · region=TC | FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image SegmentationSource quoteL264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm. |
| 2022 | TransBTSV2 proposed | Dice (ET) | 80.24% | Medical Image Segmentation · split: val · region=ET | TransBTSV2: Towards Better and More Efficient Volumetric Segmentation of Medical ImagesSource quoteL265: The quantitative results are presented in Table \ref{tab:comparison}. Our TransBTSV2 achieves the Dice scores of 80.24%, 90.42%, 84.87% and Hausdorff distance of 3.696mm, 5.432mm, 5.473mm on ET, WT, TC respectively, which are comparable or higher results than previous SOTA methods presented in Table \ref{tab:comparison}. In terms of the Hausdorff distance metric, a considerable improvement has been achieved for segmentation compared with previous SOTA methods. Additionally, it can be seen that TransBTSV2 obtains an absolute dominance over the Dice scores of ET and TC which is attribute to our redesigned Transformer block and the proposed DBM. Compared with 3D U-Net \cite{3dunet} that without Transformer as part of encoder, TransBTSV2 shows great superiority in both performance and efficiency with significant improvements. This clearly reveals the benefit of leveraging the redesigned Transformer block for modeling global relationships. |
| 2022 | Med-DANet proposed | Dice Score (WT) | 90.65% | Medical Image Segmentation · split: val · setting=Setting 2 (without sliding window) | Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric SegmentationSource quoteL273: Ours │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74 |
| 2022 | Med-DANet proposed | Dice Score (TC) | 82.72% | Medical Image Segmentation · split: val · setting=Setting 2 (without sliding window) | Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric SegmentationSource quoteL273: Ours │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74 |
| 2022 | Med-DANet proposed | FLOPs (Per Case) | 578.96 G | Medical Image Segmentation · split: val · setting=Setting 2 (without sliding window) | Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric SegmentationSource quoteL273: Ours │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74 |
| 2022 | TranSiam proposed | average Dice similarity score | 89.26% | Medical Image Segmentation · split: val | TranSiam: Fusing Multimodal Visual Features Using Transformer for Medical Image SegmentationSource quoteL224: Finally, we compare TranSiam with 3D classic methods for medical image segmentation on BraTS 2019 validation set, which include 3D U-Net \cite{2}, V-Net \cite{1}, KiU-Net \cite{3}, Attention U-Net \cite{4}, Li et al. \cite{5} and TransBTS \cite{wang2021transbts}. The experimental results are shown in Table \ref{tab:7}. Our TranSiam achieves an average Dice similarity score of 89.26% on the whole brain tumor segmentation task, which is higher than the results of the previously proposed classic 3D methods. The average HD95 of our TranSiam with 4.77 is also higher than other methods. Notably, our method does not use post-processing. Therefore, the experimental results of our method are all obtained by uploading the output of TranSiam directly to the online evaluation system. |
| 2022 | TranSiam proposed | average HD95 | 4.77 | Medical Image Segmentation · split: val | TranSiam: Fusing Multimodal Visual Features Using Transformer for Medical Image SegmentationSource quoteL224: Finally, we compare TranSiam with 3D classic methods for medical image segmentation on BraTS 2019 validation set, which include 3D U-Net \cite{2}, V-Net \cite{1}, KiU-Net \cite{3}, Attention U-Net \cite{4}, Li et al. \cite{5} and TransBTS \cite{wang2021transbts}. The experimental results are shown in Table \ref{tab:7}. Our TranSiam achieves an average Dice similarity score of 89.26% on the whole brain tumor segmentation task, which is higher than the results of the previously proposed classic 3D methods. The average HD95 of our TranSiam with 4.77 is also higher than other methods. Notably, our method does not use post-processing. Therefore, the experimental results of our method are all obtained by uploading the output of TranSiam directly to the online evaluation system. |
| 2022 | Direct Testing baseline | Dice score — WT (Whole Tumor) | 48.74 | Medical Image Segmentation · split: val · volume=3D · adaptation=none · source-modality=T1 · target-modality=T1ce | On-the-Fly Test-time Adaptation for Medical Image SegmentationSource quoteL142: Source-Training │ Direct Testing │ \multicolumn{1}{c|}{48.74/52.35/36.48} │ \multicolumn{1}{c|}{59.25/33.78/9.02} │ \textbf{\textcolor{blue}{24.35}}/39.51/\textbf{\textcolor{red}{29.38}} |
| 2022 | Direct Testing baseline | Dice score — TC (Tumor Core) | 52.35 | Medical Image Segmentation · split: val · volume=3D · adaptation=none · source-modality=T1 · target-modality=T1ce | On-the-Fly Test-time Adaptation for Medical Image SegmentationSource quoteL142: Source-Training │ Direct Testing │ \multicolumn{1}{c|}{48.74/52.35/36.48} │ \multicolumn{1}{c|}{59.25/33.78/9.02} │ \textbf{\textcolor{blue}{24.35}}/39.51/\textbf{\textcolor{red}{29.38}} |
| 2022 | Direct Testing baseline | Dice score — ET (Enhancing Tumor) | 36.48 | Medical Image Segmentation · split: val · volume=3D · adaptation=none · source-modality=T1 · target-modality=T1ce | On-the-Fly Test-time Adaptation for Medical Image SegmentationSource quoteL142: Source-Training │ Direct Testing │ \multicolumn{1}{c|}{48.74/52.35/36.48} │ \multicolumn{1}{c|}{59.25/33.78/9.02} │ \textbf{\textcolor{blue}{24.35}}/39.51/\textbf{\textcolor{red}{29.38}} |