BraTS 2019
32 papers · 83 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Also indexed as: brats-2019
Tasks on BraTS 2019All tasks (32)Medical Image Segmentation (15)Brain Tumor Segmentation (6)Anomaly Detection (2)Image Segmentation (2)3D Segmentation (1)Image to Image Translation (1)Mr Image Translation (1)Slice Index Regression (1)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Medical Image Segmentation, split=val.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Med-DANet SOTA frontier | 82.72% | 2022-01-01 | setting=Setting 2 (without sliding window) · Setting 2 (w/o slide window). | Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric SegmentationSource quoteOurs │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74 |
| 2 | Med-DANet V2 | 81.28% | 2024-01-01 | region=TC · Validation set; TC region. | Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric SegmentationSource quote\bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15 |
| 3 | FreMIM | 81.25% | 2024-01-01 | region=TC · Brain tumor segmentation; tumor core (TC) region. The cited prose does not specify th… | FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image SegmentationSource quote\paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm. |
Other primary task on BraTS 2019: Brain Tumor Segmentation · Dice score, ET ↑ (%) · val (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CGA U-Net SOTA frontier | 78.83% | 2022-03-01 | 3D-method comparison under the same parameter configuration. | Category Guided Attention Network for Brain Tumor Segmentation in MRISource quoteTo be fair, we compare with the 3D methods and conduct experiments under the same parameter configuration. From Table.~\ref{tab:comparison}, our proposed GCA U-Net achieves dice scores of 78.83%, 89.29%, 82.32% on ET, WT, TC, respectively. In particular, considerable gains (1.73% and 1.02%) have been achieved for the important ET and TC. Large improvements are also observed in terms of Hausdorff distance measure. Compared with Attention U-Net, our method shows great superiority in all metrics by supervising the attention map. Compared with nnU-Net, our method has a clear advantage on ET and slightly lower on TC and WT. However, the parameters and FLOPs of nnU-Net are 31.2M and 475.7G, respectively, while the corresponding values of our CGA U-Net are 4.77M and 151.12G. We obtain comparable results to nnU-Net with minimal computational complexity. |
| 2 | MBDRes-U-Net | 78.3% | 2024-11-01 | region=ET · BraTS 2019 results table; validation evaluated via the BraTS organizers’ online porta… | MBDRes-U-Net: Multi-Scale Lightweight Brain Tumor Segmentation NetworkSource quote78.3 |
Other primary task on BraTS 2019: Medical Image Segmentation · Dice score (WT) ↑ (%) · val (3 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Med-DANet SOTA frontier | 90.65% | 2022-01-01 | setting=Setting 2 (without sliding window) · Setting 2 (w/o slide window). | Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric SegmentationSource quoteOurs │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74 |
| 2 | Med-DANet V2 | 90.27% | 2024-01-01 | region=WT · Validation set; WT region. | Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric SegmentationSource quote\bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15 |
| 3 | FreMIM | 90.23% | 2024-01-01 | region=WT · Brain tumor segmentation; whole tumor (WT) region. The cited prose does not specify t… | FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image SegmentationSource quote\paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm. |
Other primary task on BraTS 2019: Brain Tumor Segmentation · Dice score, TC ↑ (%) · val (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MBDRes-U-Net SOTA frontier | 83.5% | 2024-11-01 | region=TC · BraTS 2019 results table; validation evaluated via the BraTS organizers’ online porta… | MBDRes-U-Net: Multi-Scale Lightweight Brain Tumor Segmentation NetworkSource quote83.5 |
| 2 | CGA U-Net SOTA frontier | 82.32% | 2022-03-01 | 3D-method comparison under the same parameter configuration. | Category Guided Attention Network for Brain Tumor Segmentation in MRISource quoteTo be fair, we compare with the 3D methods and conduct experiments under the same parameter configuration. From Table.~\ref{tab:comparison}, our proposed GCA U-Net achieves dice scores of 78.83%, 89.29%, 82.32% on ET, WT, TC, respectively. In particular, considerable gains (1.73% and 1.02%) have been achieved for the important ET and TC. Large improvements are also observed in terms of Hausdorff distance measure. Compared with Attention U-Net, our method shows great superiority in all metrics by supervising the attention map. Compared with nnU-Net, our method has a clear advantage on ET and slightly lower on TC and WT. However, the parameters and FLOPs of nnU-Net are 31.2M and 475.7G, respectively, while the corresponding values of our CGA U-Net are 4.77M and 151.12G. We obtain comparable results to nnU-Net with minimal computational complexity. |
Other primary task on BraTS 2019: Brain Tumor Segmentation · Dice score, WT ↑ (%) · val (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MBDRes-U-Net SOTA frontier | 89.5% | 2024-11-01 | region=WT · BraTS 2019 results table; validation evaluated via the BraTS organizers’ online porta… | MBDRes-U-Net: Multi-Scale Lightweight Brain Tumor Segmentation NetworkSource quote89.5 |
| 2 | CGA U-Net SOTA frontier | 89.29% | 2022-03-01 | 3D-method comparison under the same parameter configuration. | Category Guided Attention Network for Brain Tumor Segmentation in MRISource quoteTo be fair, we compare with the 3D methods and conduct experiments under the same parameter configuration. From Table.~\ref{tab:comparison}, our proposed GCA U-Net achieves dice scores of 78.83%, 89.29%, 82.32% on ET, WT, TC, respectively. In particular, considerable gains (1.73% and 1.02%) have been achieved for the important ET and TC. Large improvements are also observed in terms of Hausdorff distance measure. Compared with Attention U-Net, our method shows great superiority in all metrics by supervising the attention map. Compared with nnU-Net, our method has a clear advantage on ET and slightly lower on TC and WT. However, the parameters and FLOPs of nnU-Net are 31.2M and 475.7G, respectively, while the corresponding values of our CGA U-Net are 4.77M and 151.12G. We obtain comparable results to nnU-Net with minimal computational complexity. |
TaskMedical Image Segmentation (45)Brain Tumor Segmentation (15)Anomaly Detection (4)Survival Prediction (3)Image Segmentation (3)Mr Image Translation (3)Image to Image Translation (2)
Regimesemi-supervised (10)unsupervised-domain-adaptation (4)weakly-supervised (3)unpaired (3)one-class (2)fully-supervised (2)
Showing 26 of 26 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2024 | LLM-SegNet proposed | Dice coefficient | 85.95% | Medical Image Segmentation · split: test · semi-supervised · labeled-data=10% | Leveraging Task-Specific Knowledge from LLM for Semi-Supervised 3D Medical Image SegmentationSource quoteL240: Ours │ 85.95{\color{red}\textbf{{\uparrow}1.66}} │ 76.71{\color{red}\textbf{{\uparrow}1.97}} │ 7.62{\color{red}\textbf{{\downarrow}1.95}} │ 1.74{\color{red}\textbf{{\downarrow}0.19}} |
| 2024 | LLM-SegNet proposed | Jaccard coefficient | 76.71% | Medical Image Segmentation · split: test · semi-supervised · labeled-data=10% | Leveraging Task-Specific Knowledge from LLM for Semi-Supervised 3D Medical Image SegmentationSource quoteL240: Ours │ 85.95{\color{red}\textbf{{\uparrow}1.66}} │ 76.71{\color{red}\textbf{{\uparrow}1.97}} │ 7.62{\color{red}\textbf{{\downarrow}1.95}} │ 1.74{\color{red}\textbf{{\downarrow}0.19}} |
| 2024 | LLM-SegNet proposed | Dice coefficient | 86.69% | Medical Image Segmentation · split: test · semi-supervised · labeled-data=20% | Leveraging Task-Specific Knowledge from LLM for Semi-Supervised 3D Medical Image SegmentationSource quoteL252: Ours │ 86.69{\color{red}\textbf{{\uparrow}1.22}} │ 77.57{\color{red}\textbf{{\uparrow}1.25}} │ 6.83{\color{red}\textbf{{\downarrow}0.93}} │ 1.71{\color{red}\textbf{{\downarrow}0.29}} |
| 2024 | LLM-SegNet proposed | Jaccard coefficient | 77.57% | Medical Image Segmentation · split: test · semi-supervised · labeled-data=20% | Leveraging Task-Specific Knowledge from LLM for Semi-Supervised 3D Medical Image SegmentationSource quoteL252: Ours │ 86.69{\color{red}\textbf{{\uparrow}1.22}} │ 77.57{\color{red}\textbf{{\uparrow}1.25}} │ 6.83{\color{red}\textbf{{\downarrow}0.93}} │ 1.71{\color{red}\textbf{{\downarrow}0.29}} |
| 2024 | MLRPL baseline | Dice coefficient | 85.47% | Medical Image Segmentation · split: test · semi-supervised · labeled-data=20% | Leveraging Task-Specific Knowledge from LLM for Semi-Supervised 3D Medical Image SegmentationSource quoteL251: MLRPL \citep{su2024mutual} (MIA'24) │ 85.47 │ 76.32 │ 7.76 │ 2.00 |
| 2024 | MLRPL baseline | Jaccard coefficient | 76.32% | Medical Image Segmentation · split: test · semi-supervised · labeled-data=20% | Leveraging Task-Specific Knowledge from LLM for Semi-Supervised 3D Medical Image SegmentationSource quoteL251: MLRPL \citep{su2024mutual} (MIA'24) │ 85.47 │ 76.32 │ 7.76 │ 2.00 |
| 2023 | Balanced-Model proposed | Dice, enhancing tumour | 73.92 | Image Segmentation · split: test · model=Balanced-Model · subgroup=D0 · threshold=τ=100 | Evaluating the Fairness of Deep Learning Uncertainty Estimates in Medical Image AnalysisSource quoteL653: \textbf{\myblue{D^0}} │ 82.33 │ 74.94 │ 73.92 │ 86.67 │ 77.68 │ 71.08 |
| 2023 | Balanced-Model proposed | Dice, enhancing tumour | 48.96 | Image Segmentation · split: test · model=Balanced-Model · subgroup=D1 · threshold=τ=100 | Evaluating the Fairness of Deep Learning Uncertainty Estimates in Medical Image AnalysisSource quoteL654: \textbf{\myred{D^1}} │ 83.45 │ 68.19 │ 48.96 │ 86.24 │ 74.44 │ 71.93 |
| 2022 | Ours (geometry-aware semi-supervised method) proposed | Dice(%) | 83.54% | Medical Image Segmentation · split: test · semi-supervised · labeled-data=10% | Semi-supervised Medical Image Segmentation via Geometry-aware Consistency TrainingSource quoteL429: 83.54 |
| 2022 | nnU-Net (default hyperparameters) baseline non-standard slice | Dice_WT (Whole Tumor Dice score) | 0.9252 | Medical Image Segmentation · split: test · epochs=1000 · subset=Fair_Test | Addressing fairness issues in deep learning-based medical image analysis: a systematic reviewSource quoteL542: Avg │ 59.92 │ 0.9252 │ 0.9127 │ 0.8647 │ 3.932 │ 3.312 │ 2.657 |
| 2022 | V-Net baseline | Dice(%) | 74.43% | Medical Image Segmentation · split: test · fully-supervised · labeled-data=10% | Semi-supervised Medical Image Segmentation via Geometry-aware Consistency TrainingSource quoteL387: 74.43 |
| 2021 | ADM proposed | AUC | 0.939 | Anomaly Detection · split: test · background=black background excluded · granularity=pixel-level | Unsupervised Anomaly Detection in MR Images using Multi-Contrast InformationSource quoteL261: 0.939 |
| 2021 | Hyper-GAN (CIN) proposed | PSNR | 31.66 dB | Mr Image Translation · split: test · unpaired · contrasts=4 · evaluation=3D volumes · input_format=2D sagittal slices · translation_tasks=12 | A Unified Hyper-GAN Model for Unpaired Multi-contrast MR Image TranslationSource quoteL192: Table~\ref{tab:brats_result} reports the results on BraTS 2019 dataset of four contrasts. Our Hyper-GAN obtains significantly higher accuracies than compared methods in all metrics (p < .001) and achieves 31.66/31.90 (using CIN/FS respectively) in PSNR, comparing favorably with 30.75 of StarGAN, 30.81 of DGGAN, 30.37 of SUGAN and 30.55 of ComboGAN. |
| 2021 | Hyper-GAN (FS) proposed | PSNR | 31.90 dB | Mr Image Translation · split: test · unpaired · contrasts=4 · evaluation=3D volumes · input_format=2D sagittal slices · translation_tasks=12 | A Unified Hyper-GAN Model for Unpaired Multi-contrast MR Image TranslationSource quoteL192: Table~\ref{tab:brats_result} reports the results on BraTS 2019 dataset of four contrasts. Our Hyper-GAN obtains significantly higher accuracies than compared methods in all metrics (p < .001) and achieves 31.66/31.90 (using CIN/FS respectively) in PSNR, comparing favorably with 30.75 of StarGAN, 30.81 of DGGAN, 30.37 of SUGAN and 30.55 of ComboGAN. |
| 2021 | BiGL proposed | DSC, Average | 69.63% | Medical Image Segmentation · split: test · unsupervised-domain-adaptation · source-modality=T1 · target-modality=T2 | Cross-Modality Brain Tumor Segmentation via Bidirectional Global-to-Local Unsupervised Domain AdaptationSource quoteL183: BiGL (Ours) │ 80.39±12.48 │ 74.76±22.21 │ 53.73±25.97 │ 69.63 |
| 2021 | BiGL proposed | HD95, Average | 16.27 mm | Medical Image Segmentation · split: test · unsupervised-domain-adaptation · source-modality=T1 · target-modality=T2 | Cross-Modality Brain Tumor Segmentation via Bidirectional Global-to-Local Unsupervised Domain AdaptationSource quoteL203: BiGL (Ours) │ 13.19±13.74 │ 17.38±17.47 │ {18.23±19.23} │ 16.27 |
| 2021 | DAGc baseline | AUC | 0.909 | Anomaly Detection · split: test · background=black background excluded · granularity=pixel-level | Unsupervised Anomaly Detection in MR Images using Multi-Contrast InformationSource quoteL259: 0.909 |
| 2021 | DGGAN baseline | PSNR | 30.81 dB | Mr Image Translation · split: test · unpaired · contrasts=4 · evaluation=3D volumes · input_format=2D sagittal slices · translation_tasks=12 | A Unified Hyper-GAN Model for Unpaired Multi-contrast MR Image TranslationSource quoteL192: Table~\ref{tab:brats_result} reports the results on BraTS 2019 dataset of four contrasts. Our Hyper-GAN obtains significantly higher accuracies than compared methods in all metrics (p < .001) and achieves 31.66/31.90 (using CIN/FS respectively) in PSNR, comparing favorably with 30.75 of StarGAN, 30.81 of DGGAN, 30.37 of SUGAN and 30.55 of ComboGAN. |
| 2021 | SIFA-TMI baseline | DSC, Average | 60.20% | Medical Image Segmentation · split: test · unsupervised-domain-adaptation · source-modality=T1 · target-modality=T2 | Cross-Modality Brain Tumor Segmentation via Bidirectional Global-to-Local Unsupervised Domain AdaptationSource quoteL181: \textbf{SIFA-TMI \cite{SIFA-TMI}} │ 70.81±19.86 │ 65.32±24.57 │ 44.46±23.88 │ 60.20 |
| 2021 | SIFA-TMI baseline | HD95, Average | 17.21 mm | Medical Image Segmentation · split: test · unsupervised-domain-adaptation · source-modality=T1 · target-modality=T2 | Cross-Modality Brain Tumor Segmentation via Bidirectional Global-to-Local Unsupervised Domain AdaptationSource quoteL201: \textbf{SIFA-TMI (\cite{SIFA-TMI})} │ 14.89± 15.77 │ 19.29 ±17.43 │ 17.46± 17.72 │ 17.21 |
| 2020 | Proposed method (latent-space anomaly score, z-z′) proposed non-standard slice | AUC | 0.994 | Anomaly Detection · split: test · one-class · training-data=65 healthy HCP patients | Brain Tumor Anomaly Detection via Latent Regularized Adversarial NetworkSource quoteL284: \textbf{z-z (\prime) } │ 0.994 |
| 2020 | Proposed method (pixel-level anomaly score, x-x′) proposed non-standard slice | AUC | 0.938 | Anomaly Detection · split: test · one-class · training-data=65 healthy HCP patients | Brain Tumor Anomaly Detection via Latent Regularized Adversarial NetworkSource quoteL282: \textbf{x-x (\prime) } │ 0.938 |
| 2020 | Flow-based Deformation Guidance (our method) proposed non-standard slice | MSE | 0.0188 | Image to Image Translation · split: test · dimensionality=2D | Flow-Based Deformation Guidance for Unpaired Multi-contrast MRI Image-to-Image TranslationSource quoteL179: \quad our method │ 0.0188 │ 0.0258 │ 23.9 │ 22.8 │ 0.842 │ 0.808 |
| 2020 | Proposed hyperbolic 3D VAE with gyroplane convolution and hierarchical triplet loss proposed | Dice WT | 0.684 | 3D Segmentation · split: test · unsupervised · modality=FLAIR | Capturing implicit hierarchical structure in 3D biomedical images with self-supervised hyperbolic representationsSource quoteL205: Ours │ 0.684 │ 3D Unsup. |
| 2020 | alignflow (baseline) baseline non-standard slice | MSE | 0.022 | Image to Image Translation · split: test · dimensionality=2D | Flow-Based Deformation Guidance for Unpaired Multi-contrast MRI Image-to-Image TranslationSource quoteL178: \quad alignflow (baseline) \cite{grover2019alignflow} │ 0.022 │ 0.0306 │ 23.4 │ 21.8 │ 0.830 │ 0.784 |
| 2019 | Best-validation GBDT model (Method 6: handcrafted features + position-encoding segmentation features) proposed non-standard slice | Accuracy | 0.523 | Survival Prediction · split: test · subset=HGG patients with GTR · features=handcrafted + position-encoding segmentation · model-selection=best validation model | Domain Knowledge Based Brain Tumor Segmentation and Overall Survival PredictionSource quoteL114: Moreover, we arranged and combined features (a), (b), (c) to train the GBDT regression model, and the corresponding results on validation data were shown in Table \ref{table:result2}. It is obvious that handcrafted features is of great importance compared with the deep features (a) and position encoding features (c) (2 (nd)~to~4 (th)~rows). Selecting and combining these three features groups, it is observed that incorporating both handcrafted features and location encoding segmentation data achieved the highest accuracy of 0.586 (Method 6). We then saved the parameters obtained from the regression model that yielded the best result and applied it on testing data (Table \ref{table:result3}). We achieved an accuracy of 0.523 for OS time prediction. |