BraTS 2019
32 papers · 83 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Also indexed as: brats-2019
Tasks on BraTS 2019All tasks (32)Medical Image Segmentation (15)Brain Tumor Segmentation (6)Anomaly Detection (2)Image Segmentation (2)3D Segmentation (1)Image to Image Translation (1)Mr Image Translation (1)Slice Index Regression (1)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Medical Image Segmentation, split=val.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Med-DANet SOTA frontier | 82.72% | 2022-01-01 | setting=Setting 2 (without sliding window) · Setting 2 (w/o slide window). | Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric SegmentationSource quoteOurs │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74 |
| 2 | Med-DANet V2 | 81.28% | 2024-01-01 | region=TC · Validation set; TC region. | Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric SegmentationSource quote\bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15 |
| 3 | FreMIM | 81.25% | 2024-01-01 | region=TC · Brain tumor segmentation; tumor core (TC) region. The cited prose does not specify th… | FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image SegmentationSource quote\paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm. |
Other primary task on BraTS 2019: Brain Tumor Segmentation · Dice score, ET ↑ (%) · val (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CGA U-Net SOTA frontier | 78.83% | 2022-03-01 | 3D-method comparison under the same parameter configuration. | Category Guided Attention Network for Brain Tumor Segmentation in MRISource quoteTo be fair, we compare with the 3D methods and conduct experiments under the same parameter configuration. From Table.~\ref{tab:comparison}, our proposed GCA U-Net achieves dice scores of 78.83%, 89.29%, 82.32% on ET, WT, TC, respectively. In particular, considerable gains (1.73% and 1.02%) have been achieved for the important ET and TC. Large improvements are also observed in terms of Hausdorff distance measure. Compared with Attention U-Net, our method shows great superiority in all metrics by supervising the attention map. Compared with nnU-Net, our method has a clear advantage on ET and slightly lower on TC and WT. However, the parameters and FLOPs of nnU-Net are 31.2M and 475.7G, respectively, while the corresponding values of our CGA U-Net are 4.77M and 151.12G. We obtain comparable results to nnU-Net with minimal computational complexity. |
| 2 | MBDRes-U-Net | 78.3% | 2024-11-01 | region=ET · BraTS 2019 results table; validation evaluated via the BraTS organizers’ online porta… | MBDRes-U-Net: Multi-Scale Lightweight Brain Tumor Segmentation NetworkSource quote78.3 |
Other primary task on BraTS 2019: Medical Image Segmentation · Dice score (WT) ↑ (%) · val (3 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Med-DANet SOTA frontier | 90.65% | 2022-01-01 | setting=Setting 2 (without sliding window) · Setting 2 (w/o slide window). | Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric SegmentationSource quoteOurs │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74 |
| 2 | Med-DANet V2 | 90.27% | 2024-01-01 | region=WT · Validation set; WT region. | Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric SegmentationSource quote\bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15 |
| 3 | FreMIM | 90.23% | 2024-01-01 | region=WT · Brain tumor segmentation; whole tumor (WT) region. The cited prose does not specify t… | FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image SegmentationSource quote\paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm. |
Other primary task on BraTS 2019: Brain Tumor Segmentation · Dice score, TC ↑ (%) · val (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MBDRes-U-Net SOTA frontier | 83.5% | 2024-11-01 | region=TC · BraTS 2019 results table; validation evaluated via the BraTS organizers’ online porta… | MBDRes-U-Net: Multi-Scale Lightweight Brain Tumor Segmentation NetworkSource quote83.5 |
| 2 | CGA U-Net SOTA frontier | 82.32% | 2022-03-01 | 3D-method comparison under the same parameter configuration. | Category Guided Attention Network for Brain Tumor Segmentation in MRISource quoteTo be fair, we compare with the 3D methods and conduct experiments under the same parameter configuration. From Table.~\ref{tab:comparison}, our proposed GCA U-Net achieves dice scores of 78.83%, 89.29%, 82.32% on ET, WT, TC, respectively. In particular, considerable gains (1.73% and 1.02%) have been achieved for the important ET and TC. Large improvements are also observed in terms of Hausdorff distance measure. Compared with Attention U-Net, our method shows great superiority in all metrics by supervising the attention map. Compared with nnU-Net, our method has a clear advantage on ET and slightly lower on TC and WT. However, the parameters and FLOPs of nnU-Net are 31.2M and 475.7G, respectively, while the corresponding values of our CGA U-Net are 4.77M and 151.12G. We obtain comparable results to nnU-Net with minimal computational complexity. |
Other primary task on BraTS 2019: Brain Tumor Segmentation · Dice score, WT ↑ (%) · val (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MBDRes-U-Net SOTA frontier | 89.5% | 2024-11-01 | region=WT · BraTS 2019 results table; validation evaluated via the BraTS organizers’ online porta… | MBDRes-U-Net: Multi-Scale Lightweight Brain Tumor Segmentation NetworkSource quote89.5 |
| 2 | CGA U-Net SOTA frontier | 89.29% | 2022-03-01 | 3D-method comparison under the same parameter configuration. | Category Guided Attention Network for Brain Tumor Segmentation in MRISource quoteTo be fair, we compare with the 3D methods and conduct experiments under the same parameter configuration. From Table.~\ref{tab:comparison}, our proposed GCA U-Net achieves dice scores of 78.83%, 89.29%, 82.32% on ET, WT, TC, respectively. In particular, considerable gains (1.73% and 1.02%) have been achieved for the important ET and TC. Large improvements are also observed in terms of Hausdorff distance measure. Compared with Attention U-Net, our method shows great superiority in all metrics by supervising the attention map. Compared with nnU-Net, our method has a clear advantage on ET and slightly lower on TC and WT. However, the parameters and FLOPs of nnU-Net are 31.2M and 475.7G, respectively, while the corresponding values of our CGA U-Net are 4.77M and 151.12G. We obtain comparable results to nnU-Net with minimal computational complexity. |
TaskMedical Image Segmentation (45)Brain Tumor Segmentation (15)Anomaly Detection (4)Survival Prediction (3)Image Segmentation (3)Mr Image Translation (3)Image to Image Translation (2)
Regimesemi-supervised (10)unsupervised-domain-adaptation (4)weakly-supervised (3)unpaired (3)one-class (2)fully-supervised (2)
Showing 51 of 51 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | GMLN-BTS proposed | average Dice score | 89.4 | Image Segmentation · params=4.58M | Graph-based Multi-Modal Interaction Lightweight Network for Brain Tumor Segmentation (GMLN-BTS) in Edge Iterative MRI Lesion Localization System (EdgeIMLocSys)Source quoteL161: GMLN-BTS establishes a new benchmark for lightweight models (<5M parameters). With only 4.58M parameters, it consistently outperforms comparable models such as SegFormer3D (4.51M) and SuperLightNet (2.97M). Specifically, GMLN-BTS achieves an average Dice score of 85.1 on BraTS 2017, significantly surpassing SegFormer3D (82.2) and SuperLightNet (77.4). This performance advantage extends to BraTS 2019 and 2021, yielding scores of 89.4 and 88.7, respectively. These results demonstrate superior feature extraction efficiency under stringent parameter constraints. |
| 2025 | WeakMedSAM (SAMUS) proposed | Dice | 79.69% | Medical Image Segmentation · weakly-supervised · backbone=SAMUS | WeakMedSAM: Weakly-Supervised Medical Image Segmentation via SAM With Sub-Class Exploration and Prompt Affinity MiningSource quoteL68: By extensively evaluating on three benchmark datasets---BraTS 2019, AbdomenCT-1K and MSD Cardiac dataset---our method demonstrates promising results. Our method achieves 79.69%/77.25% in Dice and 5.57/10.35 voxels in ASSD utilizing SAMUS and EfficientSAM respectively, compared to newest WSS method with 74.61 in Dice and 11.91 voxels in ASSD on BraTS 2019 dataset. \blue{Furthermore, we validate the effectiveness of our method on small target segmentation by modifying BraTS dataset referred to as BraTS-Core, and provide comparisons with fully supervised methods to highlight the practical potential of our approach.} |
| 2025 | WeakMedSAM (EfficientSAM) proposed | Dice | 77.25% | Medical Image Segmentation · weakly-supervised · backbone=EfficientSAM | WeakMedSAM: Weakly-Supervised Medical Image Segmentation via SAM With Sub-Class Exploration and Prompt Affinity MiningSource quoteL68: By extensively evaluating on three benchmark datasets---BraTS 2019, AbdomenCT-1K and MSD Cardiac dataset---our method demonstrates promising results. Our method achieves 79.69%/77.25% in Dice and 5.57/10.35 voxels in ASSD utilizing SAMUS and EfficientSAM respectively, compared to newest WSS method with 74.61 in Dice and 11.91 voxels in ASSD on BraTS 2019 dataset. \blue{Furthermore, we validate the effectiveness of our method on small target segmentation by modifying BraTS dataset referred to as BraTS-Core, and provide comparisons with fully supervised methods to highlight the practical potential of our approach.} |
| 2024 | A4-Unet proposed | DSC (Dice Similarity Coefficient) | 94.61% | Brain Tumor Segmentation · split: val · cross-validation | A4-Unet: Deformable Multi-Scale Attention Network for Brain Tumor SegmentationSource quoteL309: BraTS 2019 │ 94.61 │ 99.85 │ 13.34 |
| 2024 | MBDRes-U-Net proposed | Dice_score — ET | 78.3% | Brain Tumor Segmentation · split: val · region=ET | MBDRes-U-Net: Multi-Scale Lightweight Brain Tumor Segmentation NetworkSource quoteL302: 78.3 |
| 2024 | MBDRes-U-Net proposed | Dice_score — WT | 89.5% | Brain Tumor Segmentation · split: val · region=WT | MBDRes-U-Net: Multi-Scale Lightweight Brain Tumor Segmentation NetworkSource quoteL303: 89.5 |
| 2024 | MBDRes-U-Net proposed | Dice_score — TC | 83.5% | Brain Tumor Segmentation · split: val · region=TC | MBDRes-U-Net: Multi-Scale Lightweight Brain Tumor Segmentation NetworkSource quoteL304: 83.5 |
| 2024 | LLM-SegNet proposed | Dice coefficient | 85.95% | Medical Image Segmentation · split: test · semi-supervised · labeled-data=10% | Leveraging Task-Specific Knowledge from LLM for Semi-Supervised 3D Medical Image SegmentationSource quoteL240: Ours │ 85.95{\color{red}\textbf{{\uparrow}1.66}} │ 76.71{\color{red}\textbf{{\uparrow}1.97}} │ 7.62{\color{red}\textbf{{\downarrow}1.95}} │ 1.74{\color{red}\textbf{{\downarrow}0.19}} |
| 2024 | LLM-SegNet proposed | Jaccard coefficient | 76.71% | Medical Image Segmentation · split: test · semi-supervised · labeled-data=10% | Leveraging Task-Specific Knowledge from LLM for Semi-Supervised 3D Medical Image SegmentationSource quoteL240: Ours │ 85.95{\color{red}\textbf{{\uparrow}1.66}} │ 76.71{\color{red}\textbf{{\uparrow}1.97}} │ 7.62{\color{red}\textbf{{\downarrow}1.95}} │ 1.74{\color{red}\textbf{{\downarrow}0.19}} |
| 2024 | LLM-SegNet proposed | Dice coefficient | 86.69% | Medical Image Segmentation · split: test · semi-supervised · labeled-data=20% | Leveraging Task-Specific Knowledge from LLM for Semi-Supervised 3D Medical Image SegmentationSource quoteL252: Ours │ 86.69{\color{red}\textbf{{\uparrow}1.22}} │ 77.57{\color{red}\textbf{{\uparrow}1.25}} │ 6.83{\color{red}\textbf{{\downarrow}0.93}} │ 1.71{\color{red}\textbf{{\downarrow}0.29}} |
| 2024 | LLM-SegNet proposed | Jaccard coefficient | 77.57% | Medical Image Segmentation · split: test · semi-supervised · labeled-data=20% | Leveraging Task-Specific Knowledge from LLM for Semi-Supervised 3D Medical Image SegmentationSource quoteL252: Ours │ 86.69{\color{red}\textbf{{\uparrow}1.22}} │ 77.57{\color{red}\textbf{{\uparrow}1.25}} │ 6.83{\color{red}\textbf{{\downarrow}0.93}} │ 1.71{\color{red}\textbf{{\downarrow}0.29}} |
| 2023 | Med-Tuning proposed | Dice (TC) | 80.44% | Volumetric Segmentation · split: val · peft · backbone=Swin-T · region=TC · pretraining=ImageNet-1K · architecture=Swin-UNet | Med-Tuning: A New Parameter-Efficient Tuning Framework for Medical Volumetric SegmentationSource quoteL795: \makecell[c]{80.44\\\textcolor{red}{(+1.28)}} |
| 2023 | Med-DANet V2 proposed | Dice score (ET) | 80.08% | Medical Image Segmentation · split: val · region=ET | Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric SegmentationSource quoteL194: \bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15 |
| 2023 | Med-DANet V2 proposed | Dice score (WT) | 90.27% | Medical Image Segmentation · split: val · region=WT | Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric SegmentationSource quoteL194: \bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15 |
| 2023 | Med-DANet V2 proposed | Dice score (TC) | 81.28% | Medical Image Segmentation · split: val · region=TC | Med-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric SegmentationSource quoteL194: \bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15 |
| 2023 | FreMIM proposed | Dice score (ET) | 79.74% | Medical Image Segmentation · split: val · region=ET | FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image SegmentationSource quoteL264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm. |
| 2023 | FreMIM proposed | Dice score (WT) | 90.23% | Medical Image Segmentation · split: val · region=WT | FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image SegmentationSource quoteL264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm. |
| 2023 | FreMIM proposed | Dice score (TC) | 81.25% | Medical Image Segmentation · split: val · region=TC | FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image SegmentationSource quoteL264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm. |
| 2023 | FreMIM proposed | Hausdorff distance (95%) (TC) | 6.934mm | Medical Image Segmentation · split: val · region=TC | FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image SegmentationSource quoteL264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm. |
| 2023 | Balanced-Model proposed | Dice, enhancing tumour | 73.92 | Image Segmentation · split: test · model=Balanced-Model · subgroup=D0 · threshold=τ=100 | Evaluating the Fairness of Deep Learning Uncertainty Estimates in Medical Image AnalysisSource quoteL653: \textbf{\myblue{D^0}} │ 82.33 │ 74.94 │ 73.92 │ 86.67 │ 77.68 │ 71.08 |
| 2023 | Balanced-Model proposed | Dice, enhancing tumour | 48.96 | Image Segmentation · split: test · model=Balanced-Model · subgroup=D1 · threshold=τ=100 | Evaluating the Fairness of Deep Learning Uncertainty Estimates in Medical Image AnalysisSource quoteL654: \textbf{\myred{D^1}} │ 83.45 │ 68.19 │ 48.96 │ 86.24 │ 74.44 │ 71.93 |
| 2022 | CGA U-Net proposed | Dice score, ET | 78.83% | Brain Tumor Segmentation · split: val | Category Guided Attention Network for Brain Tumor Segmentation in MRISource quoteL219: To be fair, we compare with the 3D methods and conduct experiments under the same parameter configuration. From Table.~\ref{tab:comparison}, our proposed GCA U-Net achieves dice scores of 78.83%, 89.29%, 82.32% on ET, WT, TC, respectively. In particular, considerable gains (1.73% and 1.02%) have been achieved for the important ET and TC. Large improvements are also observed in terms of Hausdorff distance measure. Compared with Attention U-Net, our method shows great superiority in all metrics by supervising the attention map. Compared with nnU-Net, our method has a clear advantage on ET and slightly lower on TC and WT. However, the parameters and FLOPs of nnU-Net are 31.2M and 475.7G, respectively, while the corresponding values of our CGA U-Net are 4.77M and 151.12G. We obtain comparable results to nnU-Net with minimal computational complexity. |
| 2022 | CGA U-Net proposed | Dice score, WT | 89.29% | Brain Tumor Segmentation · split: val | Category Guided Attention Network for Brain Tumor Segmentation in MRISource quoteL219: To be fair, we compare with the 3D methods and conduct experiments under the same parameter configuration. From Table.~\ref{tab:comparison}, our proposed GCA U-Net achieves dice scores of 78.83%, 89.29%, 82.32% on ET, WT, TC, respectively. In particular, considerable gains (1.73% and 1.02%) have been achieved for the important ET and TC. Large improvements are also observed in terms of Hausdorff distance measure. Compared with Attention U-Net, our method shows great superiority in all metrics by supervising the attention map. Compared with nnU-Net, our method has a clear advantage on ET and slightly lower on TC and WT. However, the parameters and FLOPs of nnU-Net are 31.2M and 475.7G, respectively, while the corresponding values of our CGA U-Net are 4.77M and 151.12G. We obtain comparable results to nnU-Net with minimal computational complexity. |
| 2022 | CGA U-Net proposed | Dice score, TC | 82.32% | Brain Tumor Segmentation · split: val | Category Guided Attention Network for Brain Tumor Segmentation in MRISource quoteL219: To be fair, we compare with the 3D methods and conduct experiments under the same parameter configuration. From Table.~\ref{tab:comparison}, our proposed GCA U-Net achieves dice scores of 78.83%, 89.29%, 82.32% on ET, WT, TC, respectively. In particular, considerable gains (1.73% and 1.02%) have been achieved for the important ET and TC. Large improvements are also observed in terms of Hausdorff distance measure. Compared with Attention U-Net, our method shows great superiority in all metrics by supervising the attention map. Compared with nnU-Net, our method has a clear advantage on ET and slightly lower on TC and WT. However, the parameters and FLOPs of nnU-Net are 31.2M and 475.7G, respectively, while the corresponding values of our CGA U-Net are 4.77M and 151.12G. We obtain comparable results to nnU-Net with minimal computational complexity. |
| 2022 | MISSU proposed | WT Dice (whole tumor) | 89.98% | Medical Image Segmentation · target=whole tumor | MISSU: 3D Medical Image Segmentation via Self-Distilling TransUNetSource quoteL284: MISSU(Ours) │ 89.98 │ 85.77 │ 80.14 |
| 2022 | MISSU proposed | TC Dice (tumor core) | 85.77% | Medical Image Segmentation · target=tumor core | MISSU: 3D Medical Image Segmentation via Self-Distilling TransUNetSource quoteL284: MISSU(Ours) │ 89.98 │ 85.77 │ 80.14 |
| 2022 | MISSU proposed | ET Dice (enhanced tumor) | 80.14% | Medical Image Segmentation · target=enhanced tumor | MISSU: 3D Medical Image Segmentation via Self-Distilling TransUNetSource quoteL284: MISSU(Ours) │ 89.98 │ 85.77 │ 80.14 |
| 2022 | TransBTSV2 proposed | Dice (ET) | 80.24% | Medical Image Segmentation · split: val · region=ET | TransBTSV2: Towards Better and More Efficient Volumetric Segmentation of Medical ImagesSource quoteL265: The quantitative results are presented in Table \ref{tab:comparison}. Our TransBTSV2 achieves the Dice scores of 80.24%, 90.42%, 84.87% and Hausdorff distance of 3.696mm, 5.432mm, 5.473mm on ET, WT, TC respectively, which are comparable or higher results than previous SOTA methods presented in Table \ref{tab:comparison}. In terms of the Hausdorff distance metric, a considerable improvement has been achieved for segmentation compared with previous SOTA methods. Additionally, it can be seen that TransBTSV2 obtains an absolute dominance over the Dice scores of ET and TC which is attribute to our redesigned Transformer block and the proposed DBM. Compared with 3D U-Net \cite{3dunet} that without Transformer as part of encoder, TransBTSV2 shows great superiority in both performance and efficiency with significant improvements. This clearly reveals the benefit of leveraging the redesigned Transformer block for modeling global relationships. |
| 2022 | Med-DANet proposed | Dice Score (WT) | 90.65% | Medical Image Segmentation · split: val · setting=Setting 2 (without sliding window) | Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric SegmentationSource quoteL273: Ours │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74 |
| 2022 | Med-DANet proposed | Dice Score (TC) | 82.72% | Medical Image Segmentation · split: val · setting=Setting 2 (without sliding window) | Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric SegmentationSource quoteL273: Ours │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74 |
| 2022 | Med-DANet proposed | FLOPs (Per Case) | 578.96 G | Medical Image Segmentation · split: val · setting=Setting 2 (without sliding window) | Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric SegmentationSource quoteL273: Ours │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74 |
| 2022 | TranSiam proposed | average Dice similarity score | 89.26% | Medical Image Segmentation · split: val | TranSiam: Fusing Multimodal Visual Features Using Transformer for Medical Image SegmentationSource quoteL224: Finally, we compare TranSiam with 3D classic methods for medical image segmentation on BraTS 2019 validation set, which include 3D U-Net \cite{2}, V-Net \cite{1}, KiU-Net \cite{3}, Attention U-Net \cite{4}, Li et al. \cite{5} and TransBTS \cite{wang2021transbts}. The experimental results are shown in Table \ref{tab:7}. Our TranSiam achieves an average Dice similarity score of 89.26% on the whole brain tumor segmentation task, which is higher than the results of the previously proposed classic 3D methods. The average HD95 of our TranSiam with 4.77 is also higher than other methods. Notably, our method does not use post-processing. Therefore, the experimental results of our method are all obtained by uploading the output of TranSiam directly to the online evaluation system. |
| 2022 | TranSiam proposed | average HD95 | 4.77 | Medical Image Segmentation · split: val | TranSiam: Fusing Multimodal Visual Features Using Transformer for Medical Image SegmentationSource quoteL224: Finally, we compare TranSiam with 3D classic methods for medical image segmentation on BraTS 2019 validation set, which include 3D U-Net \cite{2}, V-Net \cite{1}, KiU-Net \cite{3}, Attention U-Net \cite{4}, Li et al. \cite{5} and TransBTS \cite{wang2021transbts}. The experimental results are shown in Table \ref{tab:7}. Our TranSiam achieves an average Dice similarity score of 89.26% on the whole brain tumor segmentation task, which is higher than the results of the previously proposed classic 3D methods. The average HD95 of our TranSiam with 4.77 is also higher than other methods. Notably, our method does not use post-processing. Therefore, the experimental results of our method are all obtained by uploading the output of TranSiam directly to the online evaluation system. |
| 2022 | Ours (geometry-aware semi-supervised method) proposed | Dice(%) | 83.54% | Medical Image Segmentation · split: test · semi-supervised · labeled-data=10% | Semi-supervised Medical Image Segmentation via Geometry-aware Consistency TrainingSource quoteL429: 83.54 |
| 2021 | CPCL proposed | Dice | 83.36% | Medical Image Segmentation · semi-supervised · modality=T2-FLAIR MRI · labeled-data=10% | All-Around Real Label Supervision: Cyclic Prototype Consistency Learning for Semi-Supervised Medical Image SegmentationSource quoteL169: CPCL │ 83.36 {(12.58)} │ 73.23 {(16.43)} │ 11.74 {(10.02)} │ 1.99 {(1.57)} \Xhline{1pt} |
| 2021 | ADM proposed | AUC | 0.939 | Anomaly Detection · split: test · background=black background excluded · granularity=pixel-level | Unsupervised Anomaly Detection in MR Images using Multi-Contrast InformationSource quoteL261: 0.939 |
| 2021 | Ours (post-hoc OS-time prediction model) proposed | MSE | 105,746 | Survival Time Prediction · split: val · method=post-hoc · training-labels=OS-time only | Post-hoc Overall Survival Time Prediction from Brain MRISource quoteL205: Ours │ 0.517 │ 105,746 │ 51,962 │ 181,311 │ 0.248 |
| 2021 | Ours (post-hoc OS-time prediction model) proposed | Accuracy | 0.517 | Survival Classification · split: val · method=post-hoc · classes=3 · training-labels=OS-time only | Post-hoc Overall Survival Time Prediction from Brain MRISource quoteL205: Ours │ 0.517 │ 105,746 │ 51,962 │ 181,311 │ 0.248 |
| 2021 | GLOWin (z dim 512) proposed | MAE | 0.048 | Slice Index Regression · regressor=4-layer MLP · latent-dimension=512 | GLOWin: A Flow-based Invertible Generative Framework for Learning Disentangled Feature Representations in Medical ImagesSource quoteL160: GLOWin(ours) │ 512 │ 0.048 │ 0.868 |
| 2021 | Hyper-GAN (CIN) proposed | PSNR | 31.66 dB | Mr Image Translation · split: test · unpaired · contrasts=4 · evaluation=3D volumes · input_format=2D sagittal slices · translation_tasks=12 | A Unified Hyper-GAN Model for Unpaired Multi-contrast MR Image TranslationSource quoteL192: Table~\ref{tab:brats_result} reports the results on BraTS 2019 dataset of four contrasts. Our Hyper-GAN obtains significantly higher accuracies than compared methods in all metrics (p < .001) and achieves 31.66/31.90 (using CIN/FS respectively) in PSNR, comparing favorably with 30.75 of StarGAN, 30.81 of DGGAN, 30.37 of SUGAN and 30.55 of ComboGAN. |
| 2021 | Hyper-GAN (FS) proposed | PSNR | 31.90 dB | Mr Image Translation · split: test · unpaired · contrasts=4 · evaluation=3D volumes · input_format=2D sagittal slices · translation_tasks=12 | A Unified Hyper-GAN Model for Unpaired Multi-contrast MR Image TranslationSource quoteL192: Table~\ref{tab:brats_result} reports the results on BraTS 2019 dataset of four contrasts. Our Hyper-GAN obtains significantly higher accuracies than compared methods in all metrics (p < .001) and achieves 31.66/31.90 (using CIN/FS respectively) in PSNR, comparing favorably with 30.75 of StarGAN, 30.81 of DGGAN, 30.37 of SUGAN and 30.55 of ComboGAN. |
| 2021 | BiGL proposed | DSC, Average | 69.63% | Medical Image Segmentation · split: test · unsupervised-domain-adaptation · source-modality=T1 · target-modality=T2 | Cross-Modality Brain Tumor Segmentation via Bidirectional Global-to-Local Unsupervised Domain AdaptationSource quoteL183: BiGL (Ours) │ 80.39±12.48 │ 74.76±22.21 │ 53.73±25.97 │ 69.63 |
| 2021 | BiGL proposed | HD95, Average | 16.27 mm | Medical Image Segmentation · split: test · unsupervised-domain-adaptation · source-modality=T1 · target-modality=T2 | Cross-Modality Brain Tumor Segmentation via Bidirectional Global-to-Local Unsupervised Domain AdaptationSource quoteL203: BiGL (Ours) │ 13.19±13.74 │ 17.38±17.47 │ {18.23±19.23} │ 16.27 |
| 2020 | Proposed method (latent-space anomaly score, z-z′) proposed non-standard slice | AUC | 0.994 | Anomaly Detection · split: test · one-class · training-data=65 healthy HCP patients | Brain Tumor Anomaly Detection via Latent Regularized Adversarial NetworkSource quoteL284: \textbf{z-z (\prime) } │ 0.994 |
| 2020 | Proposed method (pixel-level anomaly score, x-x′) proposed non-standard slice | AUC | 0.938 | Anomaly Detection · split: test · one-class · training-data=65 healthy HCP patients | Brain Tumor Anomaly Detection via Latent Regularized Adversarial NetworkSource quoteL282: \textbf{x-x (\prime) } │ 0.938 |
| 2020 | Flow-based Deformation Guidance (our method) proposed non-standard slice | MSE | 0.0188 | Image to Image Translation · split: test · dimensionality=2D | Flow-Based Deformation Guidance for Unpaired Multi-contrast MRI Image-to-Image TranslationSource quoteL179: \quad our method │ 0.0188 │ 0.0258 │ 23.9 │ 22.8 │ 0.842 │ 0.808 |
| 2020 | KiU-Net 3D proposed | Dice-ET | 0.7321 | Brain Tumor Segmentation · split: val · modality=3D | KiU-Net: Overcomplete Convolutional Architectures for Biomedical Image and Volumetric SegmentationSource quoteL184: KiU-Net 3D │ 0.7321 │ 0.8760 │ 0.7392 │ 6.3228 │ 8.9424 │ 9.8929 |
| 2020 | Proposed hyperbolic 3D VAE with gyroplane convolution and hierarchical triplet loss proposed | Dice WT | 0.684 | 3D Segmentation · split: test · unsupervised · modality=FLAIR | Capturing implicit hierarchical structure in 3D biomedical images with self-supervised hyperbolic representationsSource quoteL205: Ours │ 0.684 │ 3D Unsup. |
| 2019 | GBDT regression, Method 6 (handcrafted features + position-encoding segmentation features) proposed non-standard slice | Accuracy | 0.586 | Survival Prediction · split: val · subset=HGG patients with GTR · features=handcrafted + position-encoding segmentation | Domain Knowledge Based Brain Tumor Segmentation and Overall Survival PredictionSource quoteL137: method 6 │ {} │ {\surd} │ {\surd} │ 0.586 │ 104985.694 │ 86581.049 │ 117638.724 │ 0.218 |
| 2019 | GBDT regression, Method 7 (PECL-DenseNet deep features + handcrafted features + position-encoding segmentation features) proposed non-standard slice | Accuracy | 0.517 | Survival Prediction · split: val · subset=HGG patients with GTR · features=PECL-DenseNet deep + handcrafted + position-encoding segmentation | Domain Knowledge Based Brain Tumor Segmentation and Overall Survival PredictionSource quoteL140: method 7 │ {\surd} │ {\surd} │ {\surd} │ 0.517 │ 200169.575 │ 51368.509 │ 309567.261 │ 0.142 |
| 2019 | Best-validation GBDT model (Method 6: handcrafted features + position-encoding segmentation features) proposed non-standard slice | Accuracy | 0.523 | Survival Prediction · split: test · subset=HGG patients with GTR · features=handcrafted + position-encoding segmentation · model-selection=best validation model | Domain Knowledge Based Brain Tumor Segmentation and Overall Survival PredictionSource quoteL114: Moreover, we arranged and combined features (a), (b), (c) to train the GBDT regression model, and the corresponding results on validation data were shown in Table \ref{table:result2}. It is obvious that handcrafted features is of great importance compared with the deep features (a) and position encoding features (c) (2 (nd)~to~4 (th)~rows). Selecting and combining these three features groups, it is observed that incorporating both handcrafted features and location encoding segmentation data achieved the highest accuracy of 0.586 (Method 6). We then saved the parameters obtained from the regression model that yielded the best result and applied it on testing data (Table \ref{table:result3}). We achieved an accuracy of 0.523 for OS time prediction. |