BraTS 2019 · Medical Image Segmentation

32 papers · 83 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Also indexed as: brats-2019

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Medical Image Segmentation, split=val.

81.181.782.382.8202220232024Med-DANet: 82.72 (2022)FreMIM: 81.25 (2024)Med-DANet V2: 81.28 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 26 of 26 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025WeakMedSAM (SAMUS) proposedDice79.69%Medical Image Segmentation · weakly-supervised · backbone=SAMUSWeakMedSAM: Weakly-Supervised Medical Image Segmentation via SAM With Sub-Class Exploration and Prompt Affinity Mining
Source quote
L68: By extensively evaluating on three benchmark datasets---BraTS 2019, AbdomenCT-1K and MSD Cardiac dataset---our method demonstrates promising results. Our method achieves 79.69%/77.25% in Dice and 5.57/10.35 voxels in ASSD utilizing SAMUS and EfficientSAM respectively, compared to newest WSS method with 74.61 in Dice and 11.91 voxels in ASSD on BraTS 2019 dataset. \blue{Furthermore, we validate the effectiveness of our method on small target segmentation by modifying BraTS dataset referred to as BraTS-Core, and provide comparisons with fully supervised methods to highlight the practical potential of our approach.}
2025WeakMedSAM (EfficientSAM) proposedDice77.25%Medical Image Segmentation · weakly-supervised · backbone=EfficientSAMWeakMedSAM: Weakly-Supervised Medical Image Segmentation via SAM With Sub-Class Exploration and Prompt Affinity Mining
Source quote
L68: By extensively evaluating on three benchmark datasets---BraTS 2019, AbdomenCT-1K and MSD Cardiac dataset---our method demonstrates promising results. Our method achieves 79.69%/77.25% in Dice and 5.57/10.35 voxels in ASSD utilizing SAMUS and EfficientSAM respectively, compared to newest WSS method with 74.61 in Dice and 11.91 voxels in ASSD on BraTS 2019 dataset. \blue{Furthermore, we validate the effectiveness of our method on small target segmentation by modifying BraTS dataset referred to as BraTS-Core, and provide comparisons with fully supervised methods to highlight the practical potential of our approach.}
2024LLM-SegNet proposedDice coefficient85.95%Medical Image Segmentation · split: test · semi-supervised · labeled-data=10%Leveraging Task-Specific Knowledge from LLM for Semi-Supervised 3D Medical Image Segmentation
Source quote
L240: Ours │ 85.95{\color{red}\textbf{{\uparrow}1.66}} │ 76.71{\color{red}\textbf{{\uparrow}1.97}} │ 7.62{\color{red}\textbf{{\downarrow}1.95}} │ 1.74{\color{red}\textbf{{\downarrow}0.19}}
2024LLM-SegNet proposedJaccard coefficient76.71%Medical Image Segmentation · split: test · semi-supervised · labeled-data=10%Leveraging Task-Specific Knowledge from LLM for Semi-Supervised 3D Medical Image Segmentation
Source quote
L240: Ours │ 85.95{\color{red}\textbf{{\uparrow}1.66}} │ 76.71{\color{red}\textbf{{\uparrow}1.97}} │ 7.62{\color{red}\textbf{{\downarrow}1.95}} │ 1.74{\color{red}\textbf{{\downarrow}0.19}}
2024LLM-SegNet proposedDice coefficient86.69%Medical Image Segmentation · split: test · semi-supervised · labeled-data=20%Leveraging Task-Specific Knowledge from LLM for Semi-Supervised 3D Medical Image Segmentation
Source quote
L252: Ours │ 86.69{\color{red}\textbf{{\uparrow}1.22}} │ 77.57{\color{red}\textbf{{\uparrow}1.25}} │ 6.83{\color{red}\textbf{{\downarrow}0.93}} │ 1.71{\color{red}\textbf{{\downarrow}0.29}}
2024LLM-SegNet proposedJaccard coefficient77.57%Medical Image Segmentation · split: test · semi-supervised · labeled-data=20%Leveraging Task-Specific Knowledge from LLM for Semi-Supervised 3D Medical Image Segmentation
Source quote
L252: Ours │ 86.69{\color{red}\textbf{{\uparrow}1.22}} │ 77.57{\color{red}\textbf{{\uparrow}1.25}} │ 6.83{\color{red}\textbf{{\downarrow}0.93}} │ 1.71{\color{red}\textbf{{\downarrow}0.29}}
2023Med-DANet V2 proposedDice score (ET)80.08%Medical Image Segmentation · split: val · region=ETMed-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric Segmentation
Source quote
L194: \bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15
2023Med-DANet V2 proposedDice score (WT)90.27%Medical Image Segmentation · split: val · region=WTMed-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric Segmentation
Source quote
L194: \bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15
2023Med-DANet V2 proposedDice score (TC)81.28%Medical Image Segmentation · split: val · region=TCMed-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric Segmentation
Source quote
L194: \bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15
2023FreMIM proposedDice score (ET)79.74%Medical Image Segmentation · split: val · region=ETFreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image Segmentation
Source quote
L264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm.
2023FreMIM proposedDice score (WT)90.23%Medical Image Segmentation · split: val · region=WTFreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image Segmentation
Source quote
L264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm.
2023FreMIM proposedDice score (TC)81.25%Medical Image Segmentation · split: val · region=TCFreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image Segmentation
Source quote
L264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm.
2023FreMIM proposedHausdorff distance (95%) (TC)6.934mmMedical Image Segmentation · split: val · region=TCFreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image Segmentation
Source quote
L264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm.
2022MISSU proposedWT Dice (whole tumor)89.98%Medical Image Segmentation · target=whole tumorMISSU: 3D Medical Image Segmentation via Self-Distilling TransUNet
Source quote
L284: MISSU(Ours) │ 89.98 │ 85.77 │ 80.14
2022MISSU proposedTC Dice (tumor core)85.77%Medical Image Segmentation · target=tumor coreMISSU: 3D Medical Image Segmentation via Self-Distilling TransUNet
Source quote
L284: MISSU(Ours) │ 89.98 │ 85.77 │ 80.14
2022MISSU proposedET Dice (enhanced tumor)80.14%Medical Image Segmentation · target=enhanced tumorMISSU: 3D Medical Image Segmentation via Self-Distilling TransUNet
Source quote
L284: MISSU(Ours) │ 89.98 │ 85.77 │ 80.14
2022TransBTSV2 proposedDice (ET)80.24%Medical Image Segmentation · split: val · region=ETTransBTSV2: Towards Better and More Efficient Volumetric Segmentation of Medical Images
Source quote
L265: The quantitative results are presented in Table \ref{tab:comparison}. Our TransBTSV2 achieves the Dice scores of 80.24%, 90.42%, 84.87% and Hausdorff distance of 3.696mm, 5.432mm, 5.473mm on ET, WT, TC respectively, which are comparable or higher results than previous SOTA methods presented in Table \ref{tab:comparison}. In terms of the Hausdorff distance metric, a considerable improvement has been achieved for segmentation compared with previous SOTA methods. Additionally, it can be seen that TransBTSV2 obtains an absolute dominance over the Dice scores of ET and TC which is attribute to our redesigned Transformer block and the proposed DBM. Compared with 3D U-Net \cite{3dunet} that without Transformer as part of encoder, TransBTSV2 shows great superiority in both performance and efficiency with significant improvements. This clearly reveals the benefit of leveraging the redesigned Transformer block for modeling global relationships.
2022Med-DANet proposedDice Score (WT)90.65%Medical Image Segmentation · split: val · setting=Setting 2 (without sliding window)Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric Segmentation
Source quote
L273: Ours │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74
2022Med-DANet proposedDice Score (TC)82.72%Medical Image Segmentation · split: val · setting=Setting 2 (without sliding window)Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric Segmentation
Source quote
L273: Ours │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74
2022Med-DANet proposedFLOPs (Per Case)578.96 GMedical Image Segmentation · split: val · setting=Setting 2 (without sliding window)Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric Segmentation
Source quote
L273: Ours │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74
2022TranSiam proposedaverage Dice similarity score89.26%Medical Image Segmentation · split: valTranSiam: Fusing Multimodal Visual Features Using Transformer for Medical Image Segmentation
Source quote
L224: Finally, we compare TranSiam with 3D classic methods for medical image segmentation on BraTS 2019 validation set, which include 3D U-Net \cite{2}, V-Net \cite{1}, KiU-Net \cite{3}, Attention U-Net \cite{4}, Li et al. \cite{5} and TransBTS \cite{wang2021transbts}. The experimental results are shown in Table \ref{tab:7}. Our TranSiam achieves an average Dice similarity score of 89.26% on the whole brain tumor segmentation task, which is higher than the results of the previously proposed classic 3D methods. The average HD95 of our TranSiam with 4.77 is also higher than other methods. Notably, our method does not use post-processing. Therefore, the experimental results of our method are all obtained by uploading the output of TranSiam directly to the online evaluation system.
2022TranSiam proposedaverage HD954.77Medical Image Segmentation · split: valTranSiam: Fusing Multimodal Visual Features Using Transformer for Medical Image Segmentation
Source quote
L224: Finally, we compare TranSiam with 3D classic methods for medical image segmentation on BraTS 2019 validation set, which include 3D U-Net \cite{2}, V-Net \cite{1}, KiU-Net \cite{3}, Attention U-Net \cite{4}, Li et al. \cite{5} and TransBTS \cite{wang2021transbts}. The experimental results are shown in Table \ref{tab:7}. Our TranSiam achieves an average Dice similarity score of 89.26% on the whole brain tumor segmentation task, which is higher than the results of the previously proposed classic 3D methods. The average HD95 of our TranSiam with 4.77 is also higher than other methods. Notably, our method does not use post-processing. Therefore, the experimental results of our method are all obtained by uploading the output of TranSiam directly to the online evaluation system.
2022Ours (geometry-aware semi-supervised method) proposedDice(%)83.54%Medical Image Segmentation · split: test · semi-supervised · labeled-data=10%Semi-supervised Medical Image Segmentation via Geometry-aware Consistency Training
Source quote
L429: 83.54
2021CPCL proposedDice83.36%Medical Image Segmentation · semi-supervised · modality=T2-FLAIR MRI · labeled-data=10%All-Around Real Label Supervision: Cyclic Prototype Consistency Learning for Semi-Supervised Medical Image Segmentation
Source quote
L169: CPCL │ 83.36 {(12.58)} │ 73.23 {(16.43)} │ 11.74 {(10.02)} │ 1.99 {(1.57)} \Xhline{1pt}
2021BiGL proposedDSC, Average69.63%Medical Image Segmentation · split: test · unsupervised-domain-adaptation · source-modality=T1 · target-modality=T2Cross-Modality Brain Tumor Segmentation via Bidirectional Global-to-Local Unsupervised Domain Adaptation
Source quote
L183: BiGL (Ours) │ 80.39±12.48 │ 74.76±22.21 │ 53.73±25.97 │ 69.63
2021BiGL proposedHD95, Average16.27 mmMedical Image Segmentation · split: test · unsupervised-domain-adaptation · source-modality=T1 · target-modality=T2Cross-Modality Brain Tumor Segmentation via Bidirectional Global-to-Local Unsupervised Domain Adaptation
Source quote
L203: BiGL (Ours) │ 13.19±13.74 │ 17.38±17.47 │ {18.23±19.23} │ 16.27