BraTS 2019

32 papers · 83 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Also indexed as: brats-2019

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Medical Image Segmentation, split=val.

81.181.782.382.8202220232024Med-DANet: 82.72 (2022)FreMIM: 81.25 (2024)Med-DANet V2: 81.28 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 26 of 26 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024A4-Unet proposedDSC (Dice Similarity Coefficient)94.61%Brain Tumor Segmentation · split: val · cross-validationA4-Unet: Deformable Multi-Scale Attention Network for Brain Tumor Segmentation
Source quote
L309: BraTS 2019 │ 94.61 │ 99.85 │ 13.34
2024MBDRes-U-Net proposedDice_score — ET78.3%Brain Tumor Segmentation · split: val · region=ETMBDRes-U-Net: Multi-Scale Lightweight Brain Tumor Segmentation Network
Source quote
L302: 78.3
2024MBDRes-U-Net proposedDice_score — WT89.5%Brain Tumor Segmentation · split: val · region=WTMBDRes-U-Net: Multi-Scale Lightweight Brain Tumor Segmentation Network
Source quote
L303: 89.5
2024MBDRes-U-Net proposedDice_score — TC83.5%Brain Tumor Segmentation · split: val · region=TCMBDRes-U-Net: Multi-Scale Lightweight Brain Tumor Segmentation Network
Source quote
L304: 83.5
2023Med-Tuning proposedDice (TC)80.44%Volumetric Segmentation · split: val · peft · backbone=Swin-T · region=TC · pretraining=ImageNet-1K · architecture=Swin-UNetMed-Tuning: A New Parameter-Efficient Tuning Framework for Medical Volumetric Segmentation
Source quote
L795: \makecell[c]{80.44\\\textcolor{red}{(+1.28)}}
2023Med-DANet V2 proposedDice score (ET)80.08%Medical Image Segmentation · split: val · region=ETMed-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric Segmentation
Source quote
L194: \bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15
2023Med-DANet V2 proposedDice score (WT)90.27%Medical Image Segmentation · split: val · region=WTMed-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric Segmentation
Source quote
L194: \bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15
2023Med-DANet V2 proposedDice score (TC)81.28%Medical Image Segmentation · split: val · region=TCMed-DANet V2: A Flexible Dynamic Architecture for Efficient Medical Volumetric Segmentation
Source quote
L194: \bf{Ours} │ 80.08 │ 90.27 │ 81.28 │ 3.494 │ 5.871 │ 6.170 │ 19.36 │ 0.15
2023FreMIM proposedDice score (ET)79.74%Medical Image Segmentation · split: val · region=ETFreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image Segmentation
Source quote
L264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm.
2023FreMIM proposedDice score (WT)90.23%Medical Image Segmentation · split: val · region=WTFreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image Segmentation
Source quote
L264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm.
2023FreMIM proposedDice score (TC)81.25%Medical Image Segmentation · split: val · region=TCFreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image Segmentation
Source quote
L264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm.
2023FreMIM proposedHausdorff distance (95%) (TC)6.934mmMedical Image Segmentation · split: val · region=TCFreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image Segmentation
Source quote
L264: \paragraph{Evaluation on Brain Tumor Segmentation.} Comparative experiments are also conducted on the BraTS 2019 validation set. As shown in Table \ref{table_sota} (a), our FreMIM achieves superior performance than previous methods with the competitive Dice scores of 79.74%, 90.23%, and 81.25% on ET, WT, and TC respectively. In addition, it is notable that our method realizes a considerable decrease of Hausdorff distance on TC, reaching 6.934mm.
2022CGA U-Net proposedDice score, ET78.83%Brain Tumor Segmentation · split: valCategory Guided Attention Network for Brain Tumor Segmentation in MRI
Source quote
L219: To be fair, we compare with the 3D methods and conduct experiments under the same parameter configuration. From Table.~\ref{tab:comparison}, our proposed GCA U-Net achieves dice scores of 78.83%, 89.29%, 82.32% on ET, WT, TC, respectively. In particular, considerable gains (1.73% and 1.02%) have been achieved for the important ET and TC. Large improvements are also observed in terms of Hausdorff distance measure. Compared with Attention U-Net, our method shows great superiority in all metrics by supervising the attention map. Compared with nnU-Net, our method has a clear advantage on ET and slightly lower on TC and WT. However, the parameters and FLOPs of nnU-Net are 31.2M and 475.7G, respectively, while the corresponding values of our CGA U-Net are 4.77M and 151.12G. We obtain comparable results to nnU-Net with minimal computational complexity.
2022CGA U-Net proposedDice score, WT89.29%Brain Tumor Segmentation · split: valCategory Guided Attention Network for Brain Tumor Segmentation in MRI
Source quote
L219: To be fair, we compare with the 3D methods and conduct experiments under the same parameter configuration. From Table.~\ref{tab:comparison}, our proposed GCA U-Net achieves dice scores of 78.83%, 89.29%, 82.32% on ET, WT, TC, respectively. In particular, considerable gains (1.73% and 1.02%) have been achieved for the important ET and TC. Large improvements are also observed in terms of Hausdorff distance measure. Compared with Attention U-Net, our method shows great superiority in all metrics by supervising the attention map. Compared with nnU-Net, our method has a clear advantage on ET and slightly lower on TC and WT. However, the parameters and FLOPs of nnU-Net are 31.2M and 475.7G, respectively, while the corresponding values of our CGA U-Net are 4.77M and 151.12G. We obtain comparable results to nnU-Net with minimal computational complexity.
2022CGA U-Net proposedDice score, TC82.32%Brain Tumor Segmentation · split: valCategory Guided Attention Network for Brain Tumor Segmentation in MRI
Source quote
L219: To be fair, we compare with the 3D methods and conduct experiments under the same parameter configuration. From Table.~\ref{tab:comparison}, our proposed GCA U-Net achieves dice scores of 78.83%, 89.29%, 82.32% on ET, WT, TC, respectively. In particular, considerable gains (1.73% and 1.02%) have been achieved for the important ET and TC. Large improvements are also observed in terms of Hausdorff distance measure. Compared with Attention U-Net, our method shows great superiority in all metrics by supervising the attention map. Compared with nnU-Net, our method has a clear advantage on ET and slightly lower on TC and WT. However, the parameters and FLOPs of nnU-Net are 31.2M and 475.7G, respectively, while the corresponding values of our CGA U-Net are 4.77M and 151.12G. We obtain comparable results to nnU-Net with minimal computational complexity.
2022TransBTSV2 proposedDice (ET)80.24%Medical Image Segmentation · split: val · region=ETTransBTSV2: Towards Better and More Efficient Volumetric Segmentation of Medical Images
Source quote
L265: The quantitative results are presented in Table \ref{tab:comparison}. Our TransBTSV2 achieves the Dice scores of 80.24%, 90.42%, 84.87% and Hausdorff distance of 3.696mm, 5.432mm, 5.473mm on ET, WT, TC respectively, which are comparable or higher results than previous SOTA methods presented in Table \ref{tab:comparison}. In terms of the Hausdorff distance metric, a considerable improvement has been achieved for segmentation compared with previous SOTA methods. Additionally, it can be seen that TransBTSV2 obtains an absolute dominance over the Dice scores of ET and TC which is attribute to our redesigned Transformer block and the proposed DBM. Compared with 3D U-Net \cite{3dunet} that without Transformer as part of encoder, TransBTSV2 shows great superiority in both performance and efficiency with significant improvements. This clearly reveals the benefit of leveraging the redesigned Transformer block for modeling global relationships.
2022Med-DANet proposedDice Score (WT)90.65%Medical Image Segmentation · split: val · setting=Setting 2 (without sliding window)Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric Segmentation
Source quote
L273: Ours │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74
2022Med-DANet proposedDice Score (TC)82.72%Medical Image Segmentation · split: val · setting=Setting 2 (without sliding window)Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric Segmentation
Source quote
L273: Ours │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74
2022Med-DANet proposedFLOPs (Per Case)578.96 GMedical Image Segmentation · split: val · setting=Setting 2 (without sliding window)Med-DANet: Dynamic Architecture Network for Efficient Medical Volumetric Segmentation
Source quote
L273: Ours │ 77.73 │ 90.65 │ 82.72 │ 38,211.12 │ 578.96 │ 3.74 │ 3.74
2022TranSiam proposedaverage Dice similarity score89.26%Medical Image Segmentation · split: valTranSiam: Fusing Multimodal Visual Features Using Transformer for Medical Image Segmentation
Source quote
L224: Finally, we compare TranSiam with 3D classic methods for medical image segmentation on BraTS 2019 validation set, which include 3D U-Net \cite{2}, V-Net \cite{1}, KiU-Net \cite{3}, Attention U-Net \cite{4}, Li et al. \cite{5} and TransBTS \cite{wang2021transbts}. The experimental results are shown in Table \ref{tab:7}. Our TranSiam achieves an average Dice similarity score of 89.26% on the whole brain tumor segmentation task, which is higher than the results of the previously proposed classic 3D methods. The average HD95 of our TranSiam with 4.77 is also higher than other methods. Notably, our method does not use post-processing. Therefore, the experimental results of our method are all obtained by uploading the output of TranSiam directly to the online evaluation system.
2022TranSiam proposedaverage HD954.77Medical Image Segmentation · split: valTranSiam: Fusing Multimodal Visual Features Using Transformer for Medical Image Segmentation
Source quote
L224: Finally, we compare TranSiam with 3D classic methods for medical image segmentation on BraTS 2019 validation set, which include 3D U-Net \cite{2}, V-Net \cite{1}, KiU-Net \cite{3}, Attention U-Net \cite{4}, Li et al. \cite{5} and TransBTS \cite{wang2021transbts}. The experimental results are shown in Table \ref{tab:7}. Our TranSiam achieves an average Dice similarity score of 89.26% on the whole brain tumor segmentation task, which is higher than the results of the previously proposed classic 3D methods. The average HD95 of our TranSiam with 4.77 is also higher than other methods. Notably, our method does not use post-processing. Therefore, the experimental results of our method are all obtained by uploading the output of TranSiam directly to the online evaluation system.
2021Ours (post-hoc OS-time prediction model) proposedMSE105,746Survival Time Prediction · split: val · method=post-hoc · training-labels=OS-time onlyPost-hoc Overall Survival Time Prediction from Brain MRI
Source quote
L205: Ours │ 0.517 │ 105,746 │ 51,962 │ 181,311 │ 0.248
2021Ours (post-hoc OS-time prediction model) proposedAccuracy0.517Survival Classification · split: val · method=post-hoc · classes=3 · training-labels=OS-time onlyPost-hoc Overall Survival Time Prediction from Brain MRI
Source quote
L205: Ours │ 0.517 │ 105,746 │ 51,962 │ 181,311 │ 0.248
2020KiU-Net 3D proposedDice-ET0.7321Brain Tumor Segmentation · split: val · modality=3DKiU-Net: Overcomplete Convolutional Architectures for Biomedical Image and Volumetric Segmentation
Source quote
L184: KiU-Net 3D │ 0.7321 │ 0.8760 │ 0.7392 │ 6.3228 │ 8.9424 │ 9.8929
2019GBDT regression, Method 6 (handcrafted features + position-encoding segmentation features) proposed non-standard sliceAccuracy0.586Survival Prediction · split: val · subset=HGG patients with GTR · features=handcrafted + position-encoding segmentationDomain Knowledge Based Brain Tumor Segmentation and Overall Survival Prediction
Source quote
L137: method 6 │ {} │ {\surd} │ {\surd} │ 0.586 │ 104985.694 │ 86581.049 │ 117638.724 │ 0.218
2019GBDT regression, Method 7 (PECL-DenseNet deep features + handcrafted features + position-encoding segmentation features) proposed non-standard sliceAccuracy0.517Survival Prediction · split: val · subset=HGG patients with GTR · features=PECL-DenseNet deep + handcrafted + position-encoding segmentationDomain Knowledge Based Brain Tumor Segmentation and Overall Survival Prediction
Source quote
L140: method 7 │ {\surd} │ {\surd} │ {\surd} │ 0.517 │ 200169.575 │ 51368.509 │ 309567.261 │ 0.142