Sarah Hooper
· 4 previous affiliations
- National Institutes of HealthSince 2020
- Research Scientist · Since 2023
- Researcher · 2020–2024
- Stanford University2017–2023
- Graduate Researcher · 2017–2023
- PhD student · 2017–2020
- Gates Foundation2018
- Intern · 2018
- Rice University2013–2017
- Undergraduate Researcher, Electrical Engineering · 2016–2017
- Undergraduate Researcher, Rice 360˚ Institute for Global Health · 2015–2017
- Undergrad student · 2013–2017
- Course Leader, “Our Place in the Future of Global Health” · 2016
- Intern · 2015
Research Overview
Sarah Hooper focuses on the intersection of machine learning and medicine, with a primary emphasis on developing deep learning methods for medical image analysis. Her research spans the entire imaging pipeline, including upstream acquisition, denoising, and synthesis, as well as downstream diagnostic tasks such as segmentation and classification. Currently a research scientist at the National Heart, Lung, and Blood Institute (NHLBI) within the National Institutes of Health (NIH), her work aims to improve the accessibility and reliability of healthcare technology by reducing hardware requirements through software and developing models that are robust to real-world clinical variability.
Research Trajectory
Hooper’s research trajectory is characterized by a shift from addressing label scarcity in medical imaging to investigating the fundamental robustness and physical grounding of deep learning models. During her early doctoral work at Stanford University, she focused on the challenges of deploying machine learning in resource-constrained environments. This included evaluating how convolutional neural networks (CNNs) perform when faced with the noise and artifacts typical of low-cost imaging hardware, a critical consideration for global health applications.
As her work progressed, she addressed the "bottleneck" of expert annotation in medical imaging. She developed frameworks for label-efficient learning, specifically fusing few-shot learning with weak supervision to train high-performing segmentation models with minimal ground-truth data. This period also saw an expansion into Eliminating Spurious Feature Reliance in Medical Imaging Models, where she investigated how models often rely on spurious features—such as hospital-specific artifacts—rather than biological markers. To counter this, she proposed reframing traditional classification tasks as segmentation tasks, arguing that forcing a model to identify specific pixels of interest improves both interpretability and generalizability.
In her recent work at the NIH, Hooper has moved toward physics-informed machine learning. This involves integrating the underlying physics of image acquisition—such as signal-to-noise ratio (SNR) units and g-factor maps in MRI—directly into the training process. By teaching models the mechanics of noise distribution, her recent research achieves better generalization across different scanner types and anatomical regions. Additionally, she has begun exploring the computational efficiency of transformers for high-resolution biomedical data, seeking to balance the need for long-context information with the practical constraints of clinical deployment.
Current Directions
Hooper’s current research at the NHLBI’s Office of AI Research focuses on expanding automated image processing applications in clinical settings. A major theme of this work is the integration of hardware-aware algorithms that can reduce the costs associated with manufacturing and maintaining medical imaging equipment. By using deep learning to compensate for lower-quality hardware or reduced acquisition times, her work seeks to make high-quality diagnostic tools more accessible globally.
She is also investigating the scalability of vision-language models for medical data. This involves developing methods to decompose complex, multi-part medical images and their corresponding textual reports into fine-grained representations. This direction aims to improve the performance of automated object detection and retrieval in large-scale clinical databases.
Representative Work
In Assessing Robustness to Noise: Low-Cost Head CT Triage, Hooper investigated the performance of triage models when applied to images from low-cost CT scanners. The study demonstrated that models trained on high-quality data from well-funded institutions often degrade when faced with the increased noise and artifacts of budget hardware. This work established a foundation for her subsequent focus on model robustness and the need for training protocols that account for hardware variability.
Addressing the high cost of expert labels, Hooper developed a framework in Cut out the annotator, keep the cutout: better segmentation with weak supervision. This research combined few-shot learning with weak supervision, using a contention-aware graphical model to aggregate outputs from multiple "weak" sources. The approach allowed for the training of segmentation networks that reached performance levels near those of fully supervised models while using significantly fewer labeled images.
Hooper also explored alternative sources of supervision in Observational Supervision for Medical Image Classification Using Gaze Data. As a primary contributor to this study, she helped demonstrate that gaze data—collected passively while a radiologist reviews a scan—contains rich information that can be used to train deep learning models. This method offers a way to scale training data without requiring clinicians to perform the additional, time-consuming task of manual labeling.
To address the tendency of models to learn "shortcuts," Hooper co-authored Reducing Reliance on Spurious Features in Medical Image Classification with Spatial Specificity. This work introduced methods to encourage models to focus on anatomically relevant regions rather than background artifacts. This theme was further developed in A case for reframing automated medical image classification as segmentation, where she argued that segmentation-based approaches are inherently more robust against shortcut learning because they require the model to localize the pathology, thereby providing a more reliable basis for clinical diagnosis.
Her recent work on image reconstruction is exemplified by SNRAware: Improved Deep Learning MRI Denoising with SNR Unit Training and G-factor Map Augmentation. In this paper, Hooper introduced a training framework that incorporates quantitative noise distribution data into the denoising process. By making the model "aware" of the underlying physics of MRI noise, the framework achieved superior denoising performance and demonstrated an ability to generalize to anatomical structures and pulse sequences not seen during training.
Profile updated
Loading new papers…
Other researchers whose papers cluster into the same research directions — a proxy for overlapping technical interests and shared intellectual neighborhoods.
See something wrong? Report a mistake