NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Where Does Free-Text 3D Grounding Fail? An Error Analysis of Report-Sentence Segmentation in Chest CT

Abdullah Arif Sheikh, Kamalaker Dadi, Raju S. BapiarXiv 2026

TL;DR

Imagine asking an AI to read a single sentence from a radiology report—like "two 2 mm nodules in the left lower lobe"—and highlight those exact pixels in a 3D chest CT scan. Current leading models fail nearly half the time, and conventional wisdom assumed they struggle with matching text descriptions to the right anatomical locations. This paper flips that assumption on its head: the AI actually understands anatomy remarkably well, failing instead because it wildly over-estimates lesion boundaries and misses tiny abnormalities.

What Problem Does This Paper Address?

Radiology archives hold millions of 3D scans paired with rich, free-text reports, yet there are no coordinate links between the words and the voxels (3D pixels). Free-text 3D grounding aims to bridge this gap: feed a model a CT volume and one report sentence, and get back a 3D segmentation mask of the exact finding described. Unlike standard segmentation models that look for broad categories (e.g., "find all lung nodules"), grounding models must resolve size, count, texture, and precise anatomical location all at once.

Figure 1: Free-text 3D grounding. Each sentence of a chest CT report is a separate prompt, and the model must return a 3D mask of exactly the region that sentence describes. Colours link three sentences of one validation report to the radiologist’s reference masks and to VoxTell’s predictions (coronal projections, rings mark small findings). The same scan is analysed in Fig. 2(a)–(d′).

While recent benchmarks made it possible to score models on this task, nobody knew why or how the best models were failing. Prior work using two-stage pipelines (propose lesions first, match to text second) suggested that matching sentences to the right lesions was the main bottleneck. The authors set out to test if that holds true for end-to-end vision-language models by dissecting every single mistake made by the leading public model, VoxTell.

Methods

Rather than training a new model, the authors perform a forensic, finding-by-finding error analysis of the publicly released VoxTell v1.1 model (which pairs a 3D convolutional image encoder with a frozen Qwen3-4B text encoder). Their toolkit includes:

  • Crucial Coordinate Alignment: Fixing a subtle dataset quirk where reorienting CT headers without transforming the masks flips annotations by 180 degrees—accidentally placing dense lesions onto healthy, air-filled lung.
  • Error Taxonomy: Categorizing every prediction using the Dice coefficient (a 0-to-1 measure of spatial overlap; $\ge 0.1$ counts as a "hit"). Misses are sorted into empty (nothing predicted), swapped (predicted another sentence's lesion), wrong side (crossed the body midline), partial (overlaps, but Dice $< 0.1$), and elsewhere (missed completely on the right side).
  • Prompt Ablations & Rule-Based Post-Processing: Stripping location words from prompts to see if the model genuinely reads them, and testing whether hard-coded anatomical rules (e.g., filtering predictions using automated lung-lobe masks from TotalSegmentator) can clean up the model's output without retraining.

Datasets

The authors evaluate on the MICCAI 2026 release of ReXGroundingCT (derived from single-institution non-contrast chest CTs in CT-RATE), which pairs individual report sentences with radiologist-drawn 3D masks:

  • Validation Set: 200 scans containing 381 findings (spanning 1,415 individual lesion instances, ranging from tiny 17-voxel specks to massive 3-million-voxel regions).
  • Hidden Test Set: 300 scans with 582 findings, evaluated via the official challenge leaderboard. (Note: No training data was used by the authors, though VoxTell's pre-training across 158 public datasets rarely sampled the ReXGroundingCT training split).

Key Insights and Ideas

  • The model actually reads the map: Across 381 validation findings, VoxTell never once predicted a lesion on the wrong side of the chest when a side was named, and almost never swapped findings between sentences (only 5 times). When the authors deleted location words from the sentences, 33 wrong-side errors suddenly appeared and performance dropped to the level of basic category-label prompting.
  • Anatomical post-processing is a dead end: Because the model already internalizes spatial language, adding clever post-processing rules—like deleting voxels outside the named lung lobe or capping the number of predicted lesions to match the text—yields zero improvement (and sometimes hurts, because real lesions often spill across lobe boundaries).
  • The real culprits are "spillover" and "blindness": When VoxTell partially misses, it touches the right lesion but paints way outside the lines—producing masks with a median volume 5.3$\times$ too large. Meanwhile, small lesions frequently yield completely empty predictions, and diffuse, non-focal patterns (like emphysema) confuse the model because it tries to segment the entire diseased organ while radiologists only mark representative patches.
Figure 2: How VoxTell fails (green = radiologist, red = VoxTell, rings mark small findings). Panels (a)–(d′) show the scan of Fig. 1 and (e) another patient. (a) Hit, consolidation (Dice 0.70). (b) Partial miss, with ground-glass opacities over-segmented 6.4× (Dice 0.07). (c) Elsewhere miss for “tree-in-bud appearance”, which names no location. (d, d′) A 287-voxel nodule prompted in full (Dice 0.85) and without location words (Dice 0.07). (e) Empty prediction for “linear opacities in the medial segment of the right middle lobe”. Further examples of each error type, including swapped misses, are given in Appendix A; wrong-side misses do not occur.

Key Results

  • Overall Grounding: On the validation set, VoxTell grounds 53.5% of findings (mean Dice 0.225). When an individual predicted component actually matches a marked lesion, segmentation quality is decent (Dice 0.517), but it hallucinates many extra components (instance precision 0.131, recall 0.256).
  • Breakdown of the 177 Misses: 61 partial (mostly massive over-segmentation), 61 elsewhere (mostly picking a neighboring lung nodule on the correct side), 50 empty (concentrated in small $<1,000$-voxel findings, which have a 24.1% empty rate vs. 5.6% for large ones), 5 swapped, and 0 wrong side.
  • Focal vs. Non-Focal: Discrete, focal lesions are grounded 59.0% of the time, whereas diffuse, non-focal findings drop to 19.2% (with airway/emphysema lowest at 14.6%).
  • Prompt Ablation: Removing location words slashes the hit rate in half from 53.5% to 27.6% (Dice drops from 0.225 to 0.104).
  • Test Set Confirmation: On the 300-scan hidden test set, the exact same patterns hold: 48.5% hit rate, 0.210 case-level Dice, and stark gaps between focal (52.5%) and non-focal (20.5%) findings.

Limitations and Future Work

The study dissects a single general-purpose checkpoint (VoxTell v1.1); a proprietary variant fine-tuned specifically on ReXGroundingCT scores higher on the leaderboard and might exhibit a shifted error profile. Furthermore, the finding categories rely on keyword parsing, anatomical lobe rules depend on automated masks, and all scans originate from a single hospital. Future work should expand this diagnostic framework to multi-center datasets (including diverse populations) and focus engineering efforts where they actually matter: sharpening boundary/extent estimation, boosting small-lesion sensitivity, and rethinking how diffuse diseases are evaluated.

Summary updated

BibTeX
@misc{sheikh2026where,
  author = {Abdullah Arif Sheikh and Kamalaker Dadi and Raju S. Bapi},
  title = {{Where Does Free-Text 3D Grounding Fail? An Error Analysis of Report-Sentence Segmentation in Chest CT}},
  year = {2026},
  eprint = {2611.33958},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.33958},
}
Figure