When Can You Trust Neural Critics? Auditing Mutual Information Estimates of Higher-Order Epistasis in Protein Language Models

Maryam Rahimimovassagh, Waldemar Karwowski, Niloofar YousefiarXiv 2026 · arXiv

TL;DR

Neural "critics" used to estimate mutual information (MI) in high-dimensional models are often too unstable to support complex biological claims. This paper introduces a rigorous diagnostic protocol, demonstrating that even when these estimators appear "stable," they often fail to recover known signals at the scale of modern protein language models (PLMs) without privileged information.

What Problem Does This Paper Address?

Researchers are increasingly using neural MI estimators to "probe" what protein language models like ESM-2 or ProtT5 actually know about biology—specifically epistasis (how the effect of one mutation depends on the presence of others). However, variational MI estimators are notoriously finicky; their variance can grow exponentially with the amount of information they are trying to measure.

The authors audit a prior study which claimed that PLMs selectively "lose" higher-order epistatic information as representations move through the model's layers. They ask a fundamental question: Are these biological findings real, or are they just artifacts of unstable math?

Methods

The authors developed a measurement framework called ORBIT-FMIB to audit the reliability of neural critics. Key components include:

  • Fixed-Subset Protocol: To prevent the neural critic from taking "shortcuts" (e.g., simply identifying which positions in a protein were mutated), they train separate critics on fixed positional subsets.
  • Walsh Decomposition: They use a Walsh transform to decompose protein fitness into discrete "orders" of interaction (1st order through 4th order).
  • Stability Auditing: They measure variability across three axes: critic seeds (initialization), independent runs (reproducibility), and pairing schemes (how "negative" examples are chosen during training).
  • Estimator Swapping: They compare the standard MINE (Mutual Information Neural Estimation) against alternatives like InfoNCE, SMILE, and Bounded-DV to see if the choice of algorithm fixes the instability.
  • Synthetic Calibration: They test these estimators on a "Gaussian channel"—a synthetic dataset where the true MI is mathematically known—matched to the exact dimensionality of real-world PLMs.
Figure 1: Measurement framework. Fixed positional subsets connect experimental fitness effects to frozen model representations via a shared Walsh transform, fit separately per layer and subset to produce a held-out dependence estimate Dℓ,S. Two distinct statistics are computed from the same Dℓ,S grid – peak-to-final retention and direct score contrast at a fixed layer – answering different questions rather than being sign-flipped versions of one statistic; both require synthetic calibration matched to the specific statistic and sample regime before any biological interpretation.

Datasets

  • GB1 Landscape: A massive experimental dataset of 149,361 variants of the IgG-binding domain of Protein G (GB1), specifically looking at four key mutation sites.
  • ORBIT-Synth: A newly introduced synthetic benchmark used to validate whether an estimator can recover a known ground-truth signal before it is applied to real biological data.

Key Insights and Ideas

  • The "Peak-to-Final" Trap: Previous studies often reported the ratio of the "peak" MI found in any layer to the MI in the final layer. The authors show this is statistically dangerous: picking the maximum of several noisy estimates naturally inflates the signal, leading to false positives.
  • Stability $\neq$ Accuracy: An estimator can be very "stable" (giving the same result across multiple seeds) while still being completely wrong. In high-dimensional tests (5,120-D), estimators were stable but failed to recover even 5% of the known synthetic signal.
  • The Search Problem vs. The Signal Problem: By using an "Oracle" critic—one given the true direction of the signal—the authors showed the signal is recoverable. This proves the failure of standard critics isn't because the information is missing, but because the "blind search" performed by the neural network fails at high dimensions.
  • Hardware Sensitivity: In a surprising "one-cell" check, the authors found that running the exact same code and seed on a V100 GPU vs. an H100 GPU yielded different results, highlighting the extreme sensitivity of these models to the execution environment.

Key Results

  • Replication Failure: A previous biological claim (that ESM-2 loses higher-order info) failed to replicate; the sign of the effect changed simply by using a different (but equally valid) way of pairing data during evaluation.
  • Dimensionality Ceiling: While some estimators (SMILE, Bounded-DV) stabilized the results for ESM-2 (2,560-D), all tested estimators failed the synthetic calibration at the higher dimensionalities of ESM-1v (5,120-D) and ProtT5 (4,096-D).
  • Oracle Performance: The Oracle critic recovered 93.3% to 98.7% of the analytic MI, whereas the "blind" estimators used in typical research recovered materially less than the required margin.
Figure 3: Order-resolved Walsh decomposition of a four-site GB1 cube. Each WT-anchored cube selects one alternative amino acid at each site and contains all 16 WT/alternative combinations. The 15 nonconstant components comprise four first-order, six second-order, four third-order, and one fourth-order positional subset. Filled circles indicate membership in the Walsh basis subset, not mutation states. Every coefficient uses all 16 vertices. In the diagram, c indexes cubes, b denotes a binary genotype, fc(b) denotes its fitness, and S denotes a positional subset. The fitness coefficient εc,S corresponds to EC,S in the main text. The same transform is applied coordinate-wise to the representations.

Limitations and Future Work

The study is currently restricted to a single biological landscape (GB1) and a specific set of four-site interactions. The authors note that while they've identified that blind search fails at high dimensions, they haven't yet characterized the exact mechanism of that failure.

They conclude that researchers should not report directional interaction-order claims unless they pass the full diagnostic protocol provided in this paper, including cross-run replication and synthetic calibration at the target dimensionality.

Summary updated

Abstract

Mutual information (MI) estimation is used to probe what neural representations encode, including in protein language models, but variational MI estimators have variance that scales at least exponentially in the true MI. We audit a prior neural-MI study of order-resolved epistasis in ESM-2 on the four-site GB1 landscape. Run-to-run differences show no systematic bias and a magnitude comparable to ordinary cross-seed retraining variability, and the evaluation-pairing scheme shifts scores substantially. At the original dimensionality, two of three alternative estimator families stabilize the estimate across seeds and one does not. In a synthetic calibration at the representation dimensionalities of two other protein language models (a Gaussian channel with known MI; no model representations), all three families recover materially less signal than required, despite correct signal ordering and stable seeds. A control critic given the true signal direction, which also reduces its input to one dimension, recovers 93.3% and 98.7% of the analytic MI at gain 1.5 (at 5,120 and 4,096 dimensions), so the signal is recoverable with privileged information, but the control does not identify why blind estimation fails. We package the checks into a reusable diagnostic protocol and conclude that even a stabilized estimator is not currently sufficient for order-resolved dependence claims made under blind search at this dimensionality and sample size.
BibTeX
@misc{rahimimovassagh2026when,
  author = {Maryam Rahimimovassagh and Waldemar Karwowski and Niloofar Yousefi},
  title = {{When Can You Trust Neural Critics? Auditing Mutual Information Estimates of Higher-Order Epistasis in Protein Language Models}},
  year = {2026},
  eprint = {2611.09046},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.09046},
}
Figure