VUV-Sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO
A. Jamil, T. Ziegler, P. Hufschmidt, Gordon Li, L. Lupin-Jimenez, Thilo Michel, I. Ostrovskiy, F. Retière, Judith Schneider, M. Wagenpfeil, Amal Alamre, J. B. Albert, G. Anton, I. J. Arnquist, I. Badhrees, P. S. Barbeau, D. Beck, V. Belov, Trilochan Bhatta, F. Bourque, J. Brodsky, A. Brown, T. Brunner, A. Burenkov, G. F. Cao, Liqiang Cao, W. R. Cen, C. Chambers, Serge A. Charlebois, M. Chiu, B. T. Cleveland, Minor J. Coon, M. Côté, A. Craycraft, W. Cree, J. Dalmasson, T. Daniels, L. Darroch, S. J. Daugherty, J. Daughhetee, S. Delaquis, A. Der Mesrobian-Kabakian, R. DeVoe, J. Dilling, Ying Ding, M. J. Dolinski, A. Dragone, J. Echevers, L. Fabris, D. Fairbank, W. M. Fairbank, J. Farine, Soheyla Feyzbakhsh, Réjean Fontaine, D. Fudenberg, G. Gallina, G. Giacomini, R. Gornea, G. Gratta, E. V. Hansen, Devin K. Harris, M. Hasan, M. Heffner, J. Höβł, E. W. Hoppe, A. House, M. Hughes, Y. Ito, A. Iverson, C. E. Jessiman, M. J. Jewell, X. S. Jiang, A. Karelin, L. J. Kaufman, T. Koffas, S. Kravitz, R. Krücken, A. Kuchenkov, K.s. Kumar, Y. Lan, A. C. Larson, D. S. Leonard, S. Li, Z. Li, C. Licciardi, Y. H. Lin, Peng Lv, R. MacLellan, B. Mong, David C. Moore, K. Murray, J. Newby, Zhe Ning, O. Njoya, F. Nolet, O. Nusair, K. Odgers, A. Odian, M. Oriunno, J. L. OrrellIEEE Transactions on Nuclear Science2018 · DOI · arXiv
Future ton-scale liquefied noble gas detectors depend on efficient light detection in the vacuum ultraviolet (VUV) range. In the past years, silicon photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large-area avalanche photodiodes. The next-generation double-beta decay experiment, nEXO, with a 5-ton liquid xenon time projection chamber will use SiPMs for detecting the 175-nm xenon scintillation light, in order to achieve an energy resolution of $\sigma/Q_{\beta\beta} = 1\%$. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler (FBK) in two complementary setups. It includes measurements of the photon-detection efficiency (PDE) with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. We report improved PDE at 175 nm compared to previous generation devices that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.
Introduction: The Challenge of VUV Detection in nEXO
The nEXO experiment is designed to observe neutrinoless double beta decay ($0\nu\beta\beta$), a hypothetical process that would prove neutrinos are Majorana fermions and help explain the matter-antimatter asymmetry of the universe. To detect this incredibly rare signal, nEXO utilizes a massive Time Projection Chamber (TPC) filled with 5 tonnes of liquid xenon (LXe).
Conceptual design of the nEXO TPC showing the scale and internal light collection surfaces.
When particles interact with the xenon, they produce scintillation light at 175 nm. Distinguishing a $0\nu\beta\beta$ signal from background requires an extraordinary energy resolution of 1%. This necessitates covering approximately 4 square meters of the detector's internal surface with light sensors that are highly efficient at VUV wavelengths, radiopure, and capable of operating at 168 K. Silicon Photomultipliers (SiPMs) have emerged as the leading technology to meet these stringent requirements.
Experimental Methodology
Researchers characterized the "VUV-HD" generation of SiPMs produced by FBK, focusing on two doping profiles: Standard Field (STD) and Low Field (LF). The study utilized specific hardware batches, including three LF samples (LF E, LF S1, LF S2) and one STD sample (STD S), compared against a calibrated Hamamatsu R9875P PMT.
Two specialized experimental setups were used:
Stanford Setup: Focused on measuring absolute PDE in a vacuum chamber where a $^{252}$Cf source triggered xenon gas scintillation.
Erlangen Setup: A cryogenic setup (168 K) using gaseous nitrogen to characterize "nuisance" signals, including dark counts, afterpulsing, and optical crosstalk.
The team employed a multi-stage pulse-fitting algorithm to statistically separate these different noise sources based on their timing and amplitude, allowing for a precise characterization of the correlated avalanche fraction.
Results and Performance Analysis
The Low Field (LF) SiPMs emerged as the superior candidate for the nEXO experiment. These sensors achieved a PDE of 15–22% at 175 nm, significantly exceeding previous generations and meeting nEXO's baseline criteria.
Mean additional charge per primary avalanche (representing correlated noise) as a function of overvoltage for LF and STD SiPM samples.
As shown in the performance data, the LF variants offer a wider stable operating window with lower correlated noise compared to the STD version. At the target operating temperature of 168 K, the dark count rate was measured at $< 2 \text{ Hz/mm}^2$, well below the maximum allowance of $50 \text{ Hz/mm}^2$. Furthermore, the fraction of correlated avalanches remained below 20% within the useful operating voltage range. Simulations based on these results suggest that nEXO can achieve its target energy resolution of $\sigma/Q_{\beta\beta} \approx 1\%$.
Conclusion and Future Work
The validation of FBK's VUV-HD LF SiPMs marks a major step toward the realization of the nEXO experiment. While these results in vacuum and gas are promising, several hurdles remain. Future work must validate these sensors while submerged in liquid xenon, where refractive index mismatches may alter the effective PDE. Additionally, the collaboration must focus on scaling these sensors into 4 $m^2$ of tiled modules and integrating them with radiopure, cold front-end electronics.
Summary updated
Abstract
Future ton-scale liquefied noble gas detectors depend on efficient light detection in the vacuum ultraviolet (VUV) range. In the past years, silicon photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large-area avalanche photodiodes. The next-generation double-beta decay experiment, nEXO, with a 5-ton liquid xenon time projection chamber will use SiPMs for detecting the 175-nm xenon scintillation light, in order to achieve an energy resolution of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\boldsymbol {\sigma }/\boldsymbol {Q_{\beta \beta }} = 1$ </tex-math></inline-formula> %. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler, Trento, Italy, in two complementary setups. It includes measurements of the photon-detection efficiency (PDE) with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. We report improved PDE at 175 nm compared to previous generation devices that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.
BibTeX
@article{jamil2018vuv,
author = {A. Jamil and T. Ziegler and P. Hufschmidt and Gordon Li and L. Lupin-Jimenez and Thilo Michel and I. Ostrovskiy and F. Retière and Judith Schneider and M. Wagenpfeil and Amal Alamre and J. B. Albert and G. Anton and I. J. Arnquist and I. Badhrees and P. S. Barbeau and D. Beck and V. Belov and Trilochan Bhatta and F. Bourque and J. Brodsky and A. Brown and T. Brunner and A. Burenkov and G. F. Cao and Liqiang Cao and W. R. Cen and C. Chambers and Serge A. Charlebois and M. Chiu and B. T. Cleveland and Minor J. Coon and M. Côté and A. Craycraft and W. Cree and J. Dalmasson and T. Daniels and L. Darroch and S. J. Daugherty and J. Daughhetee and S. Delaquis and A. Der Mesrobian-Kabakian and R. DeVoe and J. Dilling and Ying Ding and M. J. Dolinski and A. Dragone and J. Echevers and L. Fabris and D. Fairbank and W. M. Fairbank and J. Farine and Soheyla Feyzbakhsh and Réjean Fontaine and D. Fudenberg and G. Gallina and G. Giacomini and R. Gornea and G. Gratta and E. V. Hansen and Devin K. Harris and M. Hasan and M. Heffner and J. Höβł and E. W. Hoppe and A. House and M. Hughes and Y. Ito and A. Iverson and C. E. Jessiman and M. J. Jewell and X. S. Jiang and A. Karelin and L. J. Kaufman and T. Koffas and S. Kravitz and R. Krücken and A. Kuchenkov and K.S. Kumar and Y. Lan and A. C. Larson and D. S. Leonard and S. Li and Z. Li and C. Licciardi and Y. H. Lin and Peng Lv and R. MacLellan and B. Mong and David C. Moore and K. Murray and J. Newby and Zhe Ning and O. Njoya and F. Nolet and O. Nusair and K. Odgers and A. Odian and M. Oriunno and J. L. Orrell},
title = {{VUV-Sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO}},
journal = {IEEE Transactions on Nuclear Science},
year = {2018},
doi = {10.1109/tns.2018.2875668},
}