Voltage Regulation in Polymer Electrolyte Fuel Cell Systems Using Gaussian Process Model Predictive Control

Xiufei Li, Miao Yang, Miao Zhang, Yuanxin Qi, Zhuowei Li, Senbin Yu, Yuantao Wang, Linpeng Shen, Xiang LiIROS 2024 · DOI

TL;DR

This paper introduces a novel Gaussian Process Model Predictive Control (GP-MPC) approach to stabilize the output voltage of Polymer Electrolyte Fuel Cells (PEFCs). By using Gaussian Processes to model PEFC dynamics, the GP-MPC can effectively regulate hydrogen and airflow rates while respecting safety constraints, offering a data-driven alternative to traditional physics-based MPC.

What Problem Does This Paper Address?

Polymer Electrolyte Fuel Cells (PEFCs) are a promising renewable energy technology, but their widespread adoption is hindered by challenges in ensuring reliable and stable operation. Specifically, maintaining a consistent output voltage under varying workloads is crucial for practical applications. Traditional Model Predictive Control (MPC) methods often rely on complex, physics-based models that require extensive system knowledge and can be computationally intensive. This paper addresses the need for a more data-driven, less information-intensive MPC approach that can effectively control PEFC voltage while adhering to critical safety constraints, such as hydrogen pressure limits.

Methods

The core of this work is the development of a Gaussian Process Model Predictive Control (GP-MPC) framework.

  • Gaussian Process (GP) Modeling: Two GPs are employed to model the PEFC's dynamic behavior: one for the output voltage (VFC) and another for the hydrogen pressure (PH₂). These GPs learn the relationship between system inputs (hydrogen flow rate QH₂, air flow rate Qair, and current I) and the predicted states (VFC and PH₂). This approach leverages data rather than relying solely on first principles.
  • Model Predictive Control (MPC): A standard MPC framework is used, but instead of a physics-based model, it utilizes the predictions from the trained Gaussian Processes.
  • Linearization for MPC: The non-linear GP models are linearized to obtain a discrete-time state-space model (Ad, Bd, Cd) suitable for the Quadratic Programming (QP) solver used in MPC.
  • Constraint Handling: The GP-MPC incorporates constraints on input change rates and hydrogen pressure. A novel aspect is the inclusion of a special inequality that uses the GP's prediction variance and the potential for hydrogen pressure change to compensate for model imperfections and ensure robust constraint satisfaction.

Datasets

The paper utilizes a dataset generated from a detailed physical fuel cell system model built in MATLAB Simulink, which serves as the "true system dynamics" for simulation.

  • Training Data: 1000 data points were collected using Latin Hypercube Sampling (LHS) for the inputs QH₂, Qair, and current I, with a time step of 0.5 seconds.
  • Testing Data: 300 test points were generated using a different set of LHS inputs to validate the trained GP models.

Key Insights and Ideas

  • Data-Driven Control for PEFCs: Gaussian Processes offer a viable data-driven alternative to complex physics-based models for PEFC control, reducing the need for deep system knowledge.
  • Robust Constraint Handling with Uncertainty: Incorporating GP prediction variance into constraint formulation allows the controller to act more cautiously and conservatively, leading to safer operation, especially when model uncertainties are present.
  • Reduced Information Requirement: The GP-MPC requires less information about the PEFC system (only VFC and PH₂) compared to traditional MPC, making it more practical and potentially more economical in real-world implementations.
  • Trade-off between Performance and Simplicity: While the GP-MPC exhibits slightly higher overshoot and slower response times compared to a physics-based MPC, its advantages in terms of reduced modeling effort and information requirements are significant.

Key Results

  • The GP-MPC successfully maintained the fuel cell voltage at the target 48 V under workload disturbances ranging from 110-120 A.
  • The safety constraint for hydrogen pressure (limited to 2.5 atm) was satisfied throughout all tested scenarios.
  • Compared to a physics-based MPC, the GP-MPC showed a 43% higher overshoot and a 25% slower response time.
  • The GP-MPC's input control actions (QH₂ and Qair) were observed to be more conservative than the physics-based MPC, particularly when increasing QH₂, due to the added constraint that accounts for prediction uncertainty.

Limitations and Future Work

  • Overshoot and Response Time: The GP-MPC exhibited a higher overshoot and slower response time compared to the physics-based MPC.
  • Conservative Control Actions: The conservative nature of the GP-MPC's control actions, while beneficial for safety, might lead to slightly less optimal performance in terms of speed.
  • Future Work: The paper suggests that the GP-MPC framework provides a satisfactory constraint handling result under model error and linearization error. Further tuning of the parameter 'a' in the constraint formulation is mentioned as a way to balance performance and safety requirements. The authors also highlight the potential for this data-driven approach to be more economical due to reduced sensor requirements.

Summary updated

BibTeX
@inproceedings{li2024voltage,
  author = {Xiufei Li and Miao Yang and Miao Zhang and Yuanxin Qi and Zhuowei Li and Senbin Yu and Yuantao Wang and Linpeng Shen and Xiang Li},
  title = {{Voltage Regulation in Polymer Electrolyte Fuel Cell Systems Using Gaussian Process Model Predictive Control}},
  booktitle = {IEEE/RSJ International Conference on Intelligent Robots and Systems},
  year = {2024},
  doi = {10.1109/iros58592.2024.10802243},
}
Figure