TL;DR
This paper introduces a novel, fast, and motion-resilient video-based method for accurately estimating the 3D positions of fNIRS and EEG probes on a participant's head. This approach overcomes the limitations of existing methods, making it particularly suitable for challenging populations like infants and patients who cannot remain still.
What Problem Does This Paper Address?
Accurately placing sensors (probes, electrodes, optodes) on the scalp is crucial for interpreting data from neuroimaging techniques like fNIRS and EEG. This "co-registration" step is notoriously difficult, especially for developmental (infants) and clinical populations who struggle to stay still for extended periods. Current methods, such as 3D digitizers, are time-consuming, require participants to be motionless, and can be cumbersome to use in various settings. This lack of a fast, reliable, and motion-resilient method hinders research and clinical applications, particularly in populations where head size and shape vary significantly.
Methods
The authors propose an innovative video-based approach that leverages computer vision and machine learning. The core of the method involves:
- Cap Preparation: The fNIRS cap is enhanced with distinct two-color patterns and six solid color stickers at specific locations to aid in tracking.
- Participant Preparation: Three additional stickers are placed on the participant's head at anatomical fiducial points (nasion, left and right preauricular).
- Video Capture: A short video (around 20 seconds) of the participant wearing the cap is recorded using readily available camera equipment. Crucially, participants can move freely during this capture.
- Frame Cropping: A Convolutional Neural Network (CNN) is used to automatically identify and crop out everything but the head and cap from each video frame. This step is vital for handling motion.
- 3D Surface Reconstruction: Computer vision techniques (Structure from Motion) are employed to reconstruct a 3D model of the head and cap from the cropped video frames.
- Fiducial and Probe Extraction: The positions of the fiducial stickers on the head and the cap markers are identified from the 3D model. These points are then used to interpolate the precise locations of all the probes.
- MNI Space Projection: The probe positions are projected into the standardized MNI (Montreal Neurological Institute) space for group analysis.
Datasets
The paper validates its method using data from adult participants and demonstrates feasibility with infant participants. Specific datasets for training the CNN are not explicitly detailed beyond the mention of using a segmentation neural network pre-trained on the CamVid dataset and fine-tuned on their own dataset.
Key Insights and Ideas
- Motion is Not the Enemy: Unlike traditional methods that demand stillness, this approach embraces motion, using it as a cue for 3D reconstruction and making it robust to head movements.
- Leveraging Everyday Tech: The method relies on widely available photographic equipment, making it accessible and cost-effective.
- Automated and Efficient: The entire process, from video capture to probe position estimation, is largely automated, significantly reducing the time and expertise required compared to manual methods.
- Infant Feasibility is a Game-Changer: The ability to accurately position probes on infants without lengthy, motion-sensitive procedures opens new avenues for developmental neuroscience research.
Key Results
- High Validity and Reliability: The video-based method demonstrated high validity and reliability, comparable to the established 3D digitizer method in adult participants.
- Improved Reliability: The video-based method showed better intra-method reliability (2.0 ± 0.5 mm) than the 3D digitizer (2.6 ± 0.6 mm).
- Smaller Errors: The overall error in probe position estimation was an order of magnitude smaller than the typical size of the channels themselves.
- Accurate Shift Detection: The method accurately captured shifts in cap positioning between sessions, with good agreement with the 3D digitizer. In cases of disagreement, the video-based method was often found to be more accurate.
- Successful Infant Application: The paper presents a proof of concept demonstrating the method's feasibility for estimating probe positions on infant participants, a task previously considered challenging.
Limitations and Future Work
- Fiducial Recovery Dependency: The method is dependent on recovering all sticker-marked fiducials. While missing information can often be recovered from video, it remains a limitation.
- Computation Time: While capture is quick, the registration results take a few minutes to compute, meaning the technician isn't immediately aware of the registration quality.
- Future Work:
- Developing a user interface for easier cap model insertion and manual correction of detected positions.
- Exploring automation where possible, balanced with human understanding where needed.
- Creating a single neural-network pipeline for real-time calibration results.
- Facilitating data combination from different labs to create a unified anatomical framework for fNIRS analysis.
Summary updated