VERDICT‐AMICO: Ultrafast fitting algorithm for non‐invasive prostate microstructure characterization

Elisenda Bonet-Carné, Edward W. Johnston, Alessandro Daducci, Joseph G. Jacobs, Alex Freeman, David Atkinson, David J. Hawkes, Shonit Punwani, Daniel C. Alexander, Eleftheria PanagiotakiNMR 2018

TL;DR

This paper introduces VERDICT-AMICO, a significantly faster algorithm for analyzing diffusion MRI data to characterize prostate cancer microstructure. By adapting the AMICO framework, VERDICT-AMICO achieves a speedup of over three orders of magnitude while maintaining accuracy and repeatability, making it a more practical tool for clinical diagnosis.

What Problem Does This Paper Address?

Prostate cancer (PCa) diagnosis and grading heavily rely on invasive biopsies. Multi-parametric MRI (mp-MRI) offers a non-invasive alternative, but advanced techniques like VERDICT (Vascular, Extracellular, and Restricted Diffusion for Cytometry in Tumours) require computationally intensive fitting procedures. This "non-linear fitting" is slow, preventing real-time analysis and potentially leading to suboptimal parameter estimates due to local minima. The paper aims to overcome this computational bottleneck by developing a faster, yet equally reliable, method for VERDICT analysis in prostate cancer.

Methods

The core innovation is the adaptation of the Accelerated Microstructure Imaging via Convex Optimization (AMICO) framework to the VERDICT model. AMICO reformulates the fitting problem as a linear system, allowing for efficient convex optimization. Instead of solving a complex non-linear equation, AMICO uses a pre-defined "dictionary" of possible signal responses and finds the best linear combination of these responses to match the observed MRI signal. This "linearized fitting" drastically reduces computation time. The authors also explored unfixed parameters, specifically the extracellular-extravascular (EES) diffusivity ($d_{EES}$), which was previously fixed in the original VERDICT model.

Datasets

The study utilized two types of data:

  • Synthetic Data: Generated to simulate diffusion MRI signals with controlled noise levels (Signal-to-Noise Ratio - SNR) and known ground-truth parameters. This allowed for a direct comparison of accuracy between the original VERDICT and VERDICT-AMICO.
  • Clinical Data: Diffusion MRI data from eight male patients with suspected or confirmed prostate cancer. This data was used to evaluate computational time, parameter precision in different tissue types, and scan-rescan repeatability.

Key Insights and Ideas

  • Speed is King (for clinical translation): The most striking insight is the dramatic reduction in computational time. A speedup of over three orders of magnitude (from seconds per voxel to milliseconds per voxel) is not just an incremental improvement; it's a paradigm shift that could enable real-time analysis and integration into routine clinical workflows.
  • Linearization Doesn't Sacrifice Accuracy (at realistic SNRs): While the original VERDICT might perform slightly better at infinite SNR (likely due to regularization artifacts in AMICO with perfect data), VERDICT-AMICO is more accurate at clinically relevant SNRs (e.g., SNR=20). This suggests that the trade-off for speed is minimal in practical scenarios.
  • Robustness and Repeatability: VERDICT-AMICO not only speeds up the process but also offers more precise parameter estimates and improved repeatability, especially for key parameters like intracellular ($f_{IC}$) and extracellular-extravascular ($f_{EES}$) volume fractions.
  • Unfixing Parameters for Better Biophysical Models: The ability to estimate previously fixed parameters, like $d_{EES}$, leads to more biophysically plausible results and potentially better characterization of tissue components, particularly the vasculature.

Key Results

  • Computational Time: VERDICT-AMICO reduced processing time by over three orders of magnitude, from 6.55 s/voxel to 1.78 ms/voxel.
  • Accuracy (Synthetic Data): At SNR=20, VERDICT-AMICO showed lower absolute errors for most parameters, particularly the objective function, compared to the original VERDICT.
  • Precision: VERDICT-AMICO estimated parameters more precisely, with lower standard deviations.
  • Repeatability: VERDICT-AMICO demonstrated high repeatability, with improved reproducibility coefficients (RPC) and coefficients of variation (CV) compared to the original method.
  • Parameter Maps: VERDICT-AMICO produced similar parametric maps to the original VERDICT, with high Pearson correlations ($r^2 > 0.7$), and the maps appeared less noisy.
  • Tumor Conspicuity: Qualitative assessment by radiologists indicated that tumor conspicuity was maintained with VERDICT-AMICO, even when estimating an additional parameter.

Limitations and Future Work

  • Infinite SNR Artifact: VERDICT-AMICO's performance degrades at infinite SNR, which the authors attribute to regularization artifacts in AMICO when dealing with perfect data. Future work could involve adapting the regularization term based on estimated SNR per region.
  • Noise Model Assumption: AMICO currently assumes Gaussian noise. Future versions will incorporate non-Gaussian noise models to better handle varying SNR levels.
  • Dictionary Dependence: The fitting results are somewhat dependent on the dictionary values. The authors used histological information to guide dictionary selection, but larger datasets are needed for further validation.
  • T2 Heterogeneity and Permeability: The current VERDICT model, and thus VERDICT-AMICO, does not account for large differences in T2 within the same voxel or for permeability between compartments, which could introduce bias. Future work will explore incorporating these effects.
  • Repeatability in Tumors: Parameter estimation in tumor regions was less repeatable than in normal tissue, likely due to tumor heterogeneity. Further studies with more diverse tumor types are needed.
  • Clinical Validation: While promising, further comprehensive studies involving clinicians are required to fully compare the clinical utility of VERDICT-AMICO against the original method, especially regarding tumor conspicuity when unfixed parameters are used.

The VERDICT-AMICO implementation will be made freely available online.

Summary updated

BibTeX
@inproceedings{bonetcarne2018verdictamico,
  author = {Elisenda Bonet-Carné and Edward W. Johnston and Alessandro Daducci and Joseph G. Jacobs and Alex Freeman and David Atkinson and David J. Hawkes and Shonit Punwani and Daniel C. Alexander and Eleftheria Panagiotaki},
  title = {{VERDICT‐AMICO: Ultrafast fitting algorithm for non‐invasive prostate microstructure characterization}},
  booktitle = {NMR},
  year = {2018},
  doi = {10.1002/nbm.4019},
}