V03-01 AUTOMATED KIDNEY STONE SEGMENTATION DURING URETEROSCOPY USING COMPUTER VISION TECHNIQUES
Abstract
You have accessJournal of UrologyCME1 May 2022V03-01 AUTOMATED KIDNEY STONE SEGMENTATION DURING URETEROSCOPY USING COMPUTER VISION TECHNIQUES Chase Floyd, Zachary Stoebner, Daiwei Lu, Ipek Oguz, and Nicholas Kavoussi Chase FloydChase Floyd More articles by this author , Zachary StoebnerZachary Stoebner More articles by this author , Daiwei LuDaiwei Lu More articles by this author , Ipek OguzIpek Oguz More articles by this author , and Nicholas KavoussiNicholas Kavoussi More articles by this author View All Author Informationhttps://doi.org/10.1097/JU.0000000000002539.01AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: Ureteroscopy is one of the most common procedures performed for the surgical treatment of kidney stones. However, due to the small field of view, visualization can be obscured by blood and debris. Novel machine learning techniques can augment and improve endoscopic visualization. We sought to develop a computer vision method to automatically identify and segment stones during ureteroscopy. METHODS: Twenty separate videos of ureteroscopy using digital ureteroscopes (Karl Storz Flex Xc) were collected (mean duration ± SD, 22±13 seconds). Frames from each video were extracted at 20 frames per second (fps). The training data was manually annotated to identify the stone in each frame. Three established machine learning models, U-Net, U-Net++, and DenseNet, were trained using the annotated frames. We subjected each model to a hyperparameter tuning (i.e. number of epochs, batch size, and learning rate) to compare different iterations of each model for optimization. Eighty percent of the data was used to train the models with 10% for validation and 10% for testing. Outcomes included Dice similarity coefficient (DSC), accuracy (per pixel), and area under the receiver operating characteristic curve (ROC-AUC). RESULTS: We observed that the U-Net++ models performed the best with mean DSC, accuracy, and ROC-AUC of 0.92., 0.95, 0.97, respectively. This was followed by the U-Net models with DSC, accuracy, and ROC-AUC of 0.91, 0.96, and 0.97, respectively. DenseNet models showed comparably decreased performance (ROC-AUC of 0.91) with a DSC and accuracy of 0.73 and 0.87, respectively (Figure 1). Additionally, we implemented a system for the processing of real-time video feeds with overlayed model predictions. The models were able to annotate new videos at 30 fps and maintain accuracy. CONCLUSIONS: Computer vision models can be sufficiently trained to accurately segment stones during ureteroscopy. The success of the models annotating new videos at 30 frames per second demonstrates the feasibility of their application real-time in the operating room. Further model optimization, as well as the development of an automated, endoscopic navigational system, is ongoing. Source of Funding: None © 2022 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 207Issue Supplement 5May 2022Page: e201 Advertisement Copyright & Permissions© 2022 by American Urological Association Education and Research, Inc.MetricsAuthor Information Chase Floyd More articles by this author Zachary Stoebner More articles by this author Daiwei Lu More articles by this author Ipek Oguz More articles by this author Nicholas Kavoussi More articles by this author Expand All Advertisement PDF downloadLoading ...
BibTeX
@article{floyd2022v,
author = {C. Edward Floyd and Zachary A. Stoebner and Daiwei Lu and İpek Oğuz and Nicholas Kavoussi},
title = {{V03-01 AUTOMATED KIDNEY STONE SEGMENTATION DURING URETEROSCOPY USING COMPUTER VISION TECHNIQUES}},
journal = {The Journal of Urology},
year = {2022},
doi = {10.1097/ju.0000000000002539.01},
}Ask Althea to put this paper to the test.
Loading related content...