Using ZigBee low-power wireless standard for monitoring patients' signs

Olivera Kotevska, Elena Vlahu‐Gjorgievska, Sašo KoceskiGoce 2013

Abstract: This paper presents Wireless Body Area Network (WBAN) strengths and gives an understanding of what possibilities they have when using short range wireless communications protocols to facilitate versatility in the movements of health care patients. The comparison made between the wireless standards and technologies used in such systems using qualitative measures gives insight into potential opportunities for their usage. The paper investigates the feasibility of using the ZigBee protocol and findings are implemented on presented COHESY system model for continuous real time remote patients monitoring conditions.

Introduction

Pervasive healthcare aims to transition medical monitoring from clinical environments into the patient's daily life. However, creating a reliable Wireless Body Area Network (WBAN) presents a significant engineering challenge: balancing range for mobility, battery life for longevity, and throughput for vital signs, all within a small hardware footprint. Existing solutions often fail to meet all these criteria simultaneously; for instance, Bluetooth is limited by range, while RFID suffers from low data rates. This paper explores the feasibility of the ZigBee protocol as a solution to support a "ubiquitous" healthcare model where patients remain connected without being tethered to specific locations.

Protocol Analysis and Selection

A critical component of the research involved a comparative analysis of four major short-range wireless standards: RFID, Bluetooth, ZigBee, and ANT+. The evaluation focused on metrics such as range, frequency, battery life, and transmission rate to determine the most suitable candidate for continuous patient monitoring.

Comparison of short-range wireless standards across key performance metrics.

While ANT+ offers superior battery life and Bluetooth provides higher throughput, ZigBee was identified as the "sweet spot" due to its 100m range. This range is vital for the proposed system, as it allows patients to move freely within a large environment even if their mobile device is not physically on their person at all times. ZigBee provides a sufficient 250 kbit/s bandwidth for medical telemetry while maintaining a battery life of 4–6 months.

The COHESY System Architecture

The authors propose the COHESY (Collaborative Health Care System) model, a multi-tiered framework designed for real-time monitoring and peer support. The architecture is divided into several functional layers:

  1. Sensor Layer: Captures analog signals (e.g., heart rate, temperature) and converts them to digital data.
  2. Network Layer: Utilizes the ZigBee protocol to transmit data from body sensors to a mobile gateway.
  3. Mobile Application Layer: Acts as an edge processor. It includes an Aggregator for filtering and JSON formatting, and a Local Calculator for rule-based analysis to trigger immediate emergency alerts via SMS or voice calls.
  4. Information System Layer: Handles resource-intensive tasks, including long-term storage in PostgreSQL and collaborative filtering for social networking features.
High-level architecture of the COHESY system, illustrating the flow from sensors to information systems and social networks.

A unique feature of COHESY is the integration of a Social Network layer. By employing collaborative filtering, the system connects patients with similar diagnoses, allowing for peer-to-peer experience sharing and recommendations that complement professional medical advice.

Implementation and Security

To ensure data efficiency, the system uses JSON (JavaScript Object Notation) for data interchange, chosen for its compact footprint. Before formatting, data is filtered at the aggregator layer to minimize the payload, which directly reduces power consumption during transmission.

Security is addressed through a robust data flow mapping. The system implements 128-bit hash encryption and utilizes HTTPS for secure transmission to clinical centers, meeting essential privacy requirements for sensitive medical information.

Conclusion and Future Work

The research demonstrates that ZigBee is a highly viable protocol for WBANs, successfully balancing range and power efficiency. The COHESY architecture effectively offloads critical alerts to the "edge" (the mobile device) while utilizing the cloud for complex data mining.

Future developments will focus on more aggressive energy optimization algorithms to further extend sensor battery life. Additionally, the authors aim to refine the mobile application for broader platform compatibility and explore transitioning COHESY from a monitoring system to a control system capable of automated medical interventions.

Summary updated

Abstract

This paper presents Wireless Body Area Network (WBAN)strengths and gives an understanding of what possibilities they have when using short range wireless communications protocols to facilitate versatility in the movements of health care patients. The comparison made between the wireless standards and technologies used in such systems using qualitative measures gives insight into potential opportunities for their usage. The paper investigates the feasibility of using the ZigBee protocol and findings are implemented on presented COHESY system model for continuous real time remote patients monitoring conditions.
BibTeX
@inproceedings{kotevska2013using,
  author = {Olivera Kotevska and Elena Vlahu‐Gjorgievska and Sašo Koceski},
  title = {{Using ZigBee low-power wireless standard for monitoring patients' signs}},
  booktitle = {Goce},
  year = {2013},
}
Figure