Using pattern quality confirmation to control a metal-level DUV process with a top-down CD-SEM
Abstract
As critical-feature patterning processes increase in complexity and sensitivity, conventional critical dimension (CD) measurements may not afford the level of process control required for effective device production. By comparing recorded top-down scanning-electron-microscope (SEM) images to a predefined reference image, Pattern Quality Confirmation (pQC) enables a more detailed analysis of measurements captured by KLA-Tencor 8XXX series scanning-electron microscopes. An example of the utility of this additional information is discussed below for a metal interconnect level patterned with a conventional deep-ultraviolet (DUV) photolithography process. In particular, we demonstrate that for certain ranges of focus-exposure conditions, conventional post-develop CD measurements remain well within specification, however, when etched, the resulting metal-line CDs are significantly below the lower specification limit. The pQC image analysis results, however, predict the observed post-etch CD variations, and consequently offer sensitivity to yield-limiting focus drifts and excursions, enabling effective product-dispositioning (rework) decisions.
BibTeX
@inproceedings{liang2001using,
author = {Chien-Sung Liang and Hai-Qing Zhou and Mark A. Boehm and Ricky Jackson and Chih-Yu Wang and Michael D. Slessor},
title = {{Using pattern quality confirmation to control a metal-level DUV process with a top-down CD-SEM}},
booktitle = {Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE},
year = {2001},
doi = {10.1117/12.436727},
}Ask Althea to put this paper to the test.