Use of Surface-Enhanced Raman Scattering (SERS) Probes to Detect Fatty Acid Receptor Activity in a Microfluidic Device

Han Zhang, Wei Zhang, Lifu Xiao, Yan Liu, Timothy A. Gilbertson, Anhong Zhou2019 · DOI

TL;DR

Researchers have developed a novel microfluidic device that integrates Surface-Enhanced Raman Scattering (SERS) probes to simultaneously monitor cellular responses and the activity of fatty acid receptors (GPR120) in real-time. This innovative approach offers a low-cost, high-throughput platform for studying cellular interactions with dietary components, paving the way for advancements in understanding metabolic diseases like obesity.

What Problem Does This Paper Address?

Obesity is a growing global health concern, with dietary fat intake playing a significant role. Understanding how our bodies recognize and respond to dietary fats is crucial for developing targeted interventions. Fatty acids are recognized by specific receptors on cell surfaces, such as GPR120, which are involved in taste and post-ingestive fat recognition. However, studying these interactions in living cells, especially in response to varying concentrations of fatty acids, has been challenging. Traditional methods often lack the sensitivity, throughput, or real-time monitoring capabilities needed to fully elucidate these complex cellular mechanisms. Furthermore, integrating sensitive analytical techniques like Raman spectroscopy with microfluidic devices presents a challenge due to the inherent background signals from common microfluidic materials like PDMS.

Methods

The core of this work is a custom-designed microfluidic device that combines two key components:

  • Concentration Gradient Generator (CGG): This part of the device is engineered to create and deliver five distinct concentrations of fatty acids (FA) simultaneously. This allows for the simultaneous stimulation of multiple cell populations with varying FA levels, avoiding the need for sequential treatments and reducing experimental variability.
  • Micro-well Array Cell Culture Chamber: This section houses the cells. To address the issue of cell detachment in microfluidic environments, a high-aspect-ratio well structure was designed and fabricated using 3D printing and PDMS molding. This design helps to anchor the cells more securely.

For detection, the researchers employed Surface-Enhanced Raman Spectroscopy (SERS). They developed a SERS probe by conjugating 4-mercaptobenzoic acid (MBA)-functionalized gold nanorods (AuNRs) with a GPR120 antibody. This probe serves two critical functions:

  1. SERS Reporter: MBA provides characteristic Raman peaks (at 1078 cm⁻¹ and 1581 cm⁻¹) that are distinct from the PDMS background when a specific spectral range is selected.
  2. Targeting: The GPR120 antibody specifically binds to the GPR120 receptor on the cell surface.

The device was fabricated using photolithography and PDMS soft lithography. Cell culture and induction of GPR120 expression were performed within the microfluidic device. Fatty acid treatment was followed by the introduction of the SERS probe. Raman spectra were then collected using a Renishaw inVia Raman spectrometer with a 785 nm near-IR laser. Raman mapping was also utilized to visualize the distribution of GPR120 receptors on individual cells.

Datasets

Not discussed in the paper. The study focuses on experimental measurements using cell cultures and synthesized SERS probes.

Key Insights and Ideas

  • Simultaneous Monitoring: The device enables the simultaneous detection of native cell Raman signals (indicating cell health and composition) and the SERS signal from the antibody-conjugated probe (indicating receptor-ligand interaction). This is a significant advancement over methods that can only monitor one aspect at a time.
  • Overcoming PDMS Background: By carefully selecting the spectral scanning range, the researchers effectively avoided interference from the PDMS substrate, a common challenge in microfluidic Raman spectroscopy. This makes PDMS a viable material for such integrated devices.
  • High-Aspect-Ratio Wells for Cell Adhesion: The 3D printed, high-aspect-ratio micro-wells proved effective in preventing cell detachment under shear flow, ensuring stable cell cultures within the microfluidic environment.
  • SERS Probe Specificity and Sensitivity: The MBA-AuNR-GPR120 antibody probe demonstrated both specificity for the target receptor and the sensitivity required for single-cell analysis.
  • Correlation of FA Concentration and Receptor Activity: The study clearly showed a positive correlation between the concentration of linoleic acid (a fatty acid) and the intensity of the SERS signal, indicating increased GPR120 receptor activity with higher FA levels.
  • Visualization of Receptor Distribution: Raman mapping allowed for the visualization of GPR120 receptor distribution on individual cells, revealing non-uniform expression patterns.

Key Results

  • The microfluidic device successfully delivered five different concentrations of fatty acids simultaneously.
  • The high-aspect-ratio micro-wells maintained cell attachment and viability for up to 48 hours.
  • The SERS probe exhibited distinct peaks at 1078 cm⁻¹ and 1581 cm⁻¹, which did not overlap with the PDMS background.
  • A positive correlation was observed between linoleic acid concentration and the SERS peak intensity at 1078 cm⁻¹ (R² = 0.931), indicating increased GPR120 receptor activity.
  • The study demonstrated the ability to simultaneously monitor native cell peaks (e.g., phenylalanine at 1002 cm⁻¹) and the SERS signal from the receptor-probe interaction.
  • Raman mapping revealed that MBA SERS probes bound to most cells, but their distribution was not uniform across the cell surface.

Limitations and Future Work

  • Cell-to-Cell Variation: The study noted significant relative standard deviations (RSD) in SERS signal intensity, suggesting cell-to-cell variability in response to fatty acids. This could be due to factors like varying receptor expression levels or cell resistance to treatment.
  • Mechanism Elucidation: While the study demonstrates the interaction and its correlation with FA concentration, the precise molecular mechanisms underlying the SERS peak changes require further investigation.
  • Two Apparent Populations: In the 60 µM linoleic acid group, two distinct populations of SERS signals were observed, which the authors suggest could be due to cell-to-cell variation or localized receptor activation. The exact cause remains unclear.
  • Future Work: The authors suggest that this platform can be extended for biochemical measurements using SERS in PDMS-based microfluidic devices. Further experiments are needed to fully elucidate the specific mechanisms of interaction and to explore the application of this technology to a wider range of cellular receptors and analytes. The potential for single-cell analysis using this integrated SERS-microfluidic system is highlighted as a promising avenue.

Summary updated

BibTeX
@misc{zhang2019use,
  author = {Han Zhang and Wei Zhang and Lifu Xiao and Yan Liu and Timothy A. Gilbertson and Anhong Zhou},
  title = {{Use of Surface-Enhanced Raman Scattering (SERS) Probes to Detect Fatty Acid Receptor Activity in a Microfluidic Device}},
  year = {2019},
  doi = {10.3390/s19071663},
}

Loading related content...

Figure