Use of Electro-Magnetic Analysis to monitor activity of a digital circuit in a non-intrusive way
Abstract
In this paper we introduce a fully non intrusive test method which is based on the Differential Electro-Magnetic Analysis (EMA). Our objective is to demonstrate the capability of this new method to detect a modification in a circuit, like a fault voluntary injected would be. This detection is carried out by comparing a reference trace, called Reference Signature, with a differential trace representing the observed electro-magnetic activity, called Control Signature. The results show the efficiency of the proposed method. We will then introduce the possibility offered by EM measurement to be used to detect a degradation of physical parameters on Avionics equipments where no intrusion is allowed.
BibTeX
@misc{thomas2011use,
author = {Sebastien Thomas and David Faura and Guillaume Duc and Jean‐Luc Danger and Didier Regis and Marc Gatti},
title = {{Use of Electro-Magnetic Analysis to monitor activity of a digital circuit in a non-intrusive way}},
year = {2011},
doi = {10.1109/icsens.2011.6127116},
}Ask Althea to put this paper to the test.